M-TI RAPIDDOC PRO KIOSK User manual

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
1
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
OVERVIEW
185-00528 Through-Hole Mounting Accessory (Sold separately)
Materials in Box
Mounting
Plate
Use only power supply with output ratings 24VDC
max., 2.7A max., of PS2 or LPS
Alcohol Wipes (10)
(4) Mounting Screws,
6 X 5/8”,100º
Flt Hd Phl, Zinc
(5) Screws
M3x8mm Long,
Flat-Head-Phil
Threaded
Pipe
Adhesive
Pad
PSA with paper
release liner this
surface only.
Nut
(2) Security Screws,
Metric, M4 X 10mm
Round Hd, Torx, W/Lock Washer
Red Handle Tool
Authorization Card
If lost or
stolen, contact
customer
service for
replacement.
The socket-outlet (power adaptor) shall
be installed near the EQUIPMENT and
shall be easily accessible.
Access Card (5)
RapidDoc®Kiosk
C.A. Cover
(Minimal Cables)
C.A. Cover
(No Cables)
Cable Access
(C.A.)
“If the Kiosk is not mounted to a
counter or table it may fall,” causing
damage to the Kiosk or a person.
USB cables may be disconnected as
it moves around a surface. See page
9 for mounting instructions.
The applied nameplate is located at
the bottom of the product.
Equipment is only suitable for
mounting at heights < 2 meters.
See page 9 for mounting
instructions.
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
2
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
1
1
2
2
2
CABLE ACCESS COVER
REMOVING THE LID
Tuck the RFID cable into the void in the base and
place the lid on the kiosk base.
Slide the lid into place and press down on the lid.
REPLACING THE LID
Lift up the front of the lid (above the ArmorActive logo). Slide the lid back, using care when removing the lid as
not to damage the RFID cable.
Lift up the front of the lid (above the ArmorActive logo). Slide the lid back, using care when removing the lid as
not to damage the RFID cable.
With the lid off of the kiosk base, place the Cable
Access Cover into the opening from the inside.
Press until it clicks into place.
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
3
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
3 4
BASEPLATE MOUNTING
1 2
Using the mounting screws, place the mounting plate in
the desired location. See Page 9 for a Mounting Plate
drill template.
Lock the kiosk into place by rotating it counter
clockwise on the plate.
Place the kiosk by lining up the opening on the bottom of
the kiosk with the teeth on the mounting plate.
Secure the kiosk to the mounting plate using the two
security screws and the Red Handle Tool.
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
4
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
1
2
2
CABLE ROUTING
1.
1.
2.
2.
1. Through Hole Cable Routing
2. Table Top Cable Routing
3. Six USB Ports (Pro version only)
4. Ethernet (Pro version only)
5. Power
3.
5.
4.
VHB MOUNTING
Clean the surface you are mounting on with the Alcohol
wipes included in the box. Peel the film on the VHB on the
bottom of the kiosk.
Place in desired location and firmly press down for full
adhesive contact. Allow 24 hours for full VHB adhesion.
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
5
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
3
2
4
Make sure the RapidDoc® RFID Module is powered and
ready.
Place the RFID Authorization Card on the RFID Module
until the LED flashes.
If no Access Card is detected, the Base will return to
normal condition waiting for registered Access Card to
unlock the Base. The Base can register a maximum of
20 Access cards. The process will need to be repeated
for each card. If a 21st card is registered, the first regis-
tered card will be deregistered.
Place a RFID Access card on the RFID Module until
LED flashing stops and returns to solid green.
IF AUTHORIZATION CARD IS LOST OR STOLEN,
CONTACT CUSTOMER SERVICE FOR REPLACEMENT.
ACCESS CARD REGISTRATION
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

6
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
1
2
2
REMOVING THE ENCLOSURE (OR TABLET) MANUALLY
REMOVING THE ENCLOSURE (OR TABLET) VIA RFID
Insert the Red Handle Tool into the security screw hole
at the side of the RapidDoc®base-disk under the tablet.
Turn the Red Handle Tool clockwise until resistance is
felt (about halfway) and hold. NOTE: Do not grab the
tablet until after you twist the Red Handle Tool.
While holding the Red Handle Tool, remove the tablet
using one hand on the bottom left or right hand corner.
Place the RFID Access Card until the base clicks. NOTE:
Do not grab the tablet until after you hear the click.
Remove the tablet using one hand on the bottom left or
right hand corner.
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
7
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
Visual Reference System Status Condition
Solid Green LED Tablet docked
Solid Red LED Tablet removed
click
Flashing Green with audible click Tablet ready for removal
Flashing Yellow-Green and Red Ready to register an Access card
Flashing Red
Multiple undock attempts
If an Access Card is swiped more than 10
times within 2 minutes, the LED will flash Red
and not allow undock attempts for 2 minutes.
LED STATUS INDICATORS
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
8
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
3
5
2
4
6
The base can register a maximum of 20 Access cards.
Example:
NOTE: The above grid is a conceptual visual representation of
the Electronic Register.
Example:
Example:
If a card is lost or stolen:
Then re-register the remaining cards plus the new one
ordered through Customer Service. Example:
If a 21st card is registered, the first registered card will
be deregistered.
Example:
Example:
Take any of the remaining access cards and register it 20
consecutive times:
ACCESS005
ACCESS004
ACCESS003
ACCESS002
ACCESS001
ACCESS005
ACCESS004
ACCESS003
ACCESS002
ACCESS001
ACCESS006
ACCESS005
ACCESS004
ACCESS002
ACCESS001
ACCESS006
ACCESS005
ACCESS004
ACCESS003
ACCESS002
ACCESS001
ACCESS001
ACCESS001
ACCESS001
ACCESS001
IF AUTHORIZATION CARD IS LOST OR STOLEN,
CONTACT CUSTOMER SERVICE FOR REPLACEMENT.
Access Card Registration
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
9
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
Print this document at 100% (or ‘Actual Size’) to assist in placing the RapidDoc®Mounting Plate.
3.9376 in
3.9376 in
Drill Hole
FRONT
MOUNTING PLATE TEMPLATE
3” hole for Optional
Through-Hole
Mounting Accessory
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
10
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
1
3
5
2
4
6
THROUGH-HOLE MOUNTING
3”
Secure the kiosk to the mounting plate using the two
security screws and the Red Handle Tool.
Place the kiosk by lining up the opening on the bottom of
the kiosk with the teeth on the mounting plate. Lock the
kiosk into place by rotating it counter clockwise on the
plate.
NOTE: The Through-Hole Mounting Accessory is sold
separately. Peel the film on the included adhesive pad
and adhere it to the underside of the mounting plate.
Place the assembly into a pre-drilled hole 3” wide.
Attach the threaded pipe to the mounting plate with the
5 included screws.
Secure into place by twisting the nut over the threaded
pipe.
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676

RAPIDDOC®PRO KIOSK INSTALLATION GUIDE
11
MTI P/N 063-00180 rev E ©2021 MTI All Rights Reservedwww.MTIGS.com | T:801.653.3807
Federal Communication Commission interference statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures: -Reorient or relocate the receiving
antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into
an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an
experienced radio/TV technician for help.
FCC Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received, including interference that may cause undesired
operation
RF Exposure Warning
The equipment complies with RF exposure limits set forth for an uncontrolled environment. The
antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
You are cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void your authority to operate the equipment.
Technical Data:
Operating Temperature 0 - 40 °C
Si le kiosque n’est pas monté sur un comptoir ou une table, il peut tomber, causant des dommages au
kiosque ou à une personne. De plus, les câbles USB peuvent être déconnectés lorsqu’ils se déplacent
sur une surface. Voir la page 3 des instructions de montage.
L’équipement convient uniquement pour un montage à des hauteurs <2 mètres.
La plaque signalétique appliquée est située au bas du produit.
Utilisez uniquement une alimentation 185-00282 avec des puissances de sortie 24VDC max., 2,7 A
max, PS2 ou LPS
La prise de courant (adaptateur secteur) doit être installée près de l’ÉQUIPEMENT et doit être
facilement accessible.
FCC Statement
-CONTROLLED DOCUMENT- 063-00180 E-0 Status: Approved ECO-112676
ECO-112676
Table of contents
Other M-TI Rack & Stand manuals