Multilink Optima S User manual

DocumentNo.020-349-10InstallGuide
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/13/2020 Document No. 020-349-10 Install Guide
Page 1
Scan
QR for
website.
Contact Us |
North America
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: engsupport@gomultilink.com
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: engsupport@gomultilink.com
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: lasupport@gomultilink.com
Europe, Middle East & Africa Latin & South America
© Multilink Inc. 2020 •All Rights Reserved www.gomultilink.com
Optima S Enclosure
General 3
1. Introduction 3
1.1 Product Description
1.2 Optima S Dimensional Drawing
2. Preparations 4
2.1 Installation Outline
2.2 Optima S Checklist
2.3 Recommended Tools and Equipment
3. General Warnings 5
3.1 Laser Light Warning
3.2 Laser Light Magnication Warning
3.3 Loose Fiber Warning
3.4 Sharp Edge Warning
3.5 Safety Glasses Warning
3.6 Electrical Shock Warning
3.7 Fiber Damage Warning
4. Installation 6
Entry Cable Preparations 6
4.1 Entry Cable Prep
4.2 Cable Jacket Removal
4.3 Cut & Trim CSM
4.4 Armored Cable
4.5 Grounding Kit *sold separately
4.6 Connecting the Grounding Braid
4.7 Drill Ground Lug Hole
4.8 Insert Ground Lug
4.9 Secured Grounding
Table of Contents
Table of Contents Continues on Page 2

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Contact Us |
North America
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Europe, Middle East & Africa Latin & South America
Page 2
DocumentNo.020-349-20InstallGuide
Table of Contents (Cont.)
Optima S Base Installation 8
4.10 Install CSM Clamp
4.11 Fiber Management Clips
4.12 Proper Grommet Seal
4.13 Install CSM & Cable Grommet
4.14 Secure Cable to Base
4.15 Fiber Routing & Attach Tie-Wraps
4.16 Buer Tube Branching
4.17 Attach Tie-Wraps
Splicing Buer Tube to Pigtail 10
4.18 Splice Input Fiber to Pigtail
4.19 Splice Tray Routing
4.20 Attach Splice Tray
4.21 Attach Splice Tray Cover
4.22 Pigtail & Branch Buer Tube Routing
Optima S Hinged Shell Installation 11
4.23 Fiber Management & Tie-Wraps
4.24 Pigtail Fiber Routing
4.25 Fiber Management
4.26 Bulkhead Adapter(s) & Connector(s)
4.27 Sealing the Gap
4.28 Closing the Fiber Closure
4.29 Apply Sealant to the Perimeter
4.30 Start to Connect Cover to Base
4.31 Tighten Bolts to S-Base
Optima S Distribution Installation 14
4.32 Install Optidrop(s)
4.33 Install Optidrop Fiber Connector
4.34 Apply Sealant Directly to Gel
4.35 Latch Cover to Optima Shell
5. Accessory List 15

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Contact Us |
North America
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Europe, Middle East & Africa Latin & South America
Page 3
DocumentNo.020-349-20InstallGuide
This installation guide provides instructions for preparation, installation and application of
Multilink’s Optima closure. This product provides a solution for in-line access to the ber optic trunk
line and quick connection to subscribers single drop cable or to low count drop, feeder or lateral
cable to be connected to single drop cable at another location. This guide is for installers who are
familiar with ber optic cable systems and their applications.
1.1 Product Description
Multilink’s Optima S closure allows a FTTX provider to access the ber optic trunk line (that is
deployed from the central oce, headend, or remote hub) and branch connections o to individual
subscribers (such as home, apartment, or individual business). Connections can also be branched
o to low count drop cables to feed another terminal point. Contact Multilink at (440) 366-6966 for
assistance for FTTX network planning and FTTX deployment products.
1.2 Optima S Di-
mensional Drawing
General
1. Introduction
Parameter Specication
Splice Capacity Up to 48 (2 QTY
splice trays)
Patch Capacity 12 SC / 24 LC
Cable Diameter Up to 0.68”
Connector Types
SC/APC
SC/UPC
LC/APC
LC/UPC
Cable Types Armored
Unarmored
15.015
2.472
14.840
2.100
7.580
7.941
7.312
2.022
6.156
8.000
15.012
3.981
6.124
3.062
4.000
8.000
4.589
3.500
8.281
7.944
1.750
.450 .500
2.489
2.100
1.729
m
NO SHARP EDGES OR
BURRS ALLOWED
DRAWN BY:
MATERIAL:
FINISH:
.XX=
.03
.XXX=
.010
020-349-00-REF
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
ultilink
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
SCALE:
SIZE
CAD FILE:
DWG. NO.
B
SHEET:
1
OF
1
REV.
OPTIMA-S STANDARD
TERM SPLICE ENCL
W/O GROMMETS
REV.
DESCRIPTION OF CHANGE
DATE
ECN #
1:3.5
020-349-00-REF
FRACTIONS: DECIMALS: ANGLES:
1/32
1
ALL FLATS TO BE
.005
DO NOT SCALE DRAWING
11/21/17
020-349-00-REF
L.P.K.
L.P.K.
02
N/A
SEE B.O.M.
INITIAL RELEASE
N/A
01
11/21/17
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY
NOT BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
15.015
2.472
14.840
2.100
7.580
7.941
7.312
2.022
6.156
8.000
15.012
3.981
6.124
3.062
4.000
8.000
4.589
3.500
8.281
7.944
1.750
.450 .500
2.489
2.100
1.729
m
NO SHARP EDGES OR
BURRS ALLOWED
DRAWN BY:
MATERIAL:
FINISH:
.XX=
.03
.XXX=
.010
020-349-00-REF
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
ultilink
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
SCALE:
SIZE
CAD FILE:
DWG. NO.
B
SHEET:
1
OF
1
REV.
OPTIMA-S STANDARD
TERM SPLICE ENCL
W/O GROMMETS
REV.
DESCRIPTION OF CHANGE
DATE
ECN #
1:3.5
020-349-00-REF
FRACTIONS: DECIMALS: ANGLES:
1/32
1
ALL FLATS TO BE
.005
DO NOT SCALE DRAWING
11/21/17
020-349-00-REF
L.P.K.
L.P.K.
02
N/A
SEE B.O.M.
INITIAL RELEASE
N/A
01
11/21/17
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY
NOT BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
15.015
2.472
14.840
2.100
7.580
7.941
7.312
2.022
6.156
8.000
15.012
3.981
6.124
3.062
4.000
8.000
4.589
3.500
8.281
7.944
1.750
.450 .500
2.489
2.100
1.729
m
NO SHARP EDGES OR
BURRS ALLOWED
DRAWN BY:
MATERIAL:
FINISH:
.XX=
.03
.XXX=
.010
020-349-00-REF
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
ultilink
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
SCALE:
SIZE
CAD FILE:
DWG. NO.
B
SHEET:
1
OF
1
REV.
OPTIMA-S STANDARD
TERM SPLICE ENCL
W/O GROMMETS
REV.
DESCRIPTION OF CHANGE
DATE
ECN #
1:3.5
020-349-00-REF
FRACTIONS: DECIMALS: ANGLES:
1/32
1
ALL FLATS TO BE
.005
DO NOT SCALE DRAWING
11/21/17
020-349-00-REF
L.P.K.
L.P.K.
02
N/A
SEE B.O.M.
INITIAL RELEASE
N/A
01
11/21/17
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY
NOT BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
15.015
2.472
14.840
2.100
7.580
7.941
7.312
2.022
6.156
8.000
15.012
3.981
6.124
3.062
4.000
8.000
4.589
3.500
8.281
7.944
1.750
.450 .500
2.489
2.100
1.729
m
NO SHARP EDGES OR
BURRS ALLOWED
DRAWN BY:
MATERIAL:
FINISH:
.XX=
.03
.XXX=
.010
020-349-00-REF
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
ultilink
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
SCALE:
SIZE
CAD FILE:
DWG. NO.
B
SHEET:
1
OF
1
REV.
OPTIMA-S STANDARD
TERM SPLICE ENCL
W/O GROMMETS
REV.
DESCRIPTION OF CHANGE
DATE
ECN #
1:3.5
020-349-00-REF
FRACTIONS: DECIMALS: ANGLES:
1/32
1
ALL FLATS TO BE
.005
DO NOT SCALE DRAWING
11/21/17
020-349-00-REF
L.P.K.
L.P.K.
02
N/A
SEE B.O.M.
INITIAL RELEASE
N/A
01
11/21/17
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY
NOT BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
15.015
2.472
14.840
2.100
7.580
7.941
7.312
2.022
6.156
8.000
15.012
3.981
6.124
3.062
4.000
8.000
4.589
3.500
8.281
7.944
1.750
.450 .500
2.489
2.100
1.729
m
NO SHARP EDGES OR
BURRS ALLOWED
DRAWN BY:
MATERIAL:
FINISH:
.XX=
.03
.XXX=
.010
020-349-00-REF
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
ultilink
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
SCALE:
SIZE
CAD FILE:
DWG. NO.
B
SHEET:
1
OF
1
REV.
OPTIMA-S STANDARD
TERM SPLICE ENCL
W/O GROMMETS
REV.
DESCRIPTION OF CHANGE
DATE
ECN #
1:3.5
020-349-00-REF
FRACTIONS: DECIMALS: ANGLES:
1/32
1
ALL FLATS TO BE
.005
DO NOT SCALE DRAWING
11/21/17
020-349-00-REF
L.P.K.
L.P.K.
02
N/A
SEE B.O.M.
INITIAL RELEASE
N/A
01
11/21/17
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY
NOT BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Contact Us |
North America
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: [email protected]
Europe, Middle East & Africa Latin & South America
Page 4
DocumentNo.020-349-20InstallGuide
2. Preparations
2.1 Installation Outline
The general procedure of the Optima S installation includes:
• Removal of cable jacketing and excess CSM (Central Strength Member)
• Ring cut, ber separation, CSM tie down, and routing ber
• Securing ber in place to the Optima S closure
• Conguring grommets for cable entry and exit drop
• Splicing and ber termination
2.2 Optima S Checklist
Each kit includes the following items:
• 1x Optima S Assembly (A)
• 1x Splice Tray Kit (B)
• 1x Hardware Kit (C)
• Safety Glasses
• Cut-Resistant Gloves
• Torque Screw Driver (inch pounds)
• Phillips Screw Driver
• Scissors / Razor Knife
• Tape Measure
• Side Cutters/Diagonal Cutters
• Fiber Strippers
• Colored Marker(s)
• Ring Cut Tool
• Mastic Tape
2.3 Recommended Tools and Equipment
The Following list includes tools and equipment that you may need for a successful
installation (these tools ARE NOT INCLUDED with the product or accessories):
2.400
60mm
BEND RADIUS GAUGE
DO NOT EXCEED THE BEND
RADIUS MENTIONED TO
AVOID DAMAGING FIBER
SCALE 1:1
ultilink
NO SHARP EDGES OR
BURRS ALLOWED
SCALE:
SIZE
CAD FILE:
DWG. NO.
A
SHEET
OF
REV.
DRAWN BY:
FRACTIONS DECIMALS ANGLES
1/32
MATERIAL:
FINISH:
DO NOT SCALE DRAWING
Description
Bend Radius Gauge
1:1
11
DESCRIPTION OF CHANGE
REV
DATE
ECN#
.XX=
.03
.XXX=
.010
1
ALL FLATS TO BE
.005
Bend Radius Gauge
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY NOT
BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
m
00/00/15
Bend Radius Gauge
JM
01
XX GA. / 0.000 XXXXX
N/A
JM
00/00/15
01
N/A
INITIAL RELEASE
AB
C

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 5
DocumentNo.020-349-20InstallGuide
3. General Warnings
3.1 Laser Light Warning
Never look directly into the end of a ber that may be carrying laser light. Laser light
can be invisible and may be harmful to your eyes. Viewing it directly may not cause pain;
therefore it will not cause blinking or the iris of the eye to close involuntarily as it does when
viewing bright light. Consequently, serious damage to the retina of the eye is possible. Should
accidental exposure of laser light be suspected, arrange an eye exam immediately.
3.2 Laser Light Magnication Warning
Do not use magniers in the presence of laser radiation. Diused laser light can cause
serious eye damage if focused with optical instruments.
3.3 Loose Fiber Warning
Cleaved or broken glass bers are very sharp and can pierce the skin easily. Keep your
work area clear of removed ber. Do not allow pieces of ber to stick to your clothing or fall
into the work area where they can cause injury later. Use tweezers to pick up broken/cut
pieces of ber and place on a piece of tape that has been set aside for this purpose.
3.4 Sharp Edge Warning
The wearing of cut-resistant safety gloves to protect your hands from sharp cutting
tools and the metal armoring of armored cable is strongly recommended. Use extreme care
when working with severed armor. There may be sharp edges where the armor is damaged.
Always cover the exposed/cut armor end with a wrap of black electrical tape. To minimize the
chance of injury from sharp-blade tools, always cut away from yourself and others. Dispose of
used blades and armor scrap properly.
3.5 Safety Glasses Warning
Use safety glasses while working is highly recommended to provide eye protection
from accidental injury when handling chemicals, cables or working with ber. Pieces of glass
ber are very sharp and have potential to damage the eye.
3.6 Electrical Shock Warning
Do not install telecommunications equipment or work with telephone wiring during
a lightning storm. Telephone lines can carry high voltages from lightning causing electrical
shock resulting in severe injury or death.
3.7 Fiber Damage Warning
Fiber Optic cable is highly sensitive to excessive pulling, bending and crushing. Take
care when bending the cables. Be sure not to pull too hard on the bers. Do not crush the
cable or allow it to kink. Doing any of these things may cause damage to the ber and require
it to be replaced.

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 6
DocumentNo.020-349-20InstallGuide
4. Installation
Entry Cable Preparations
4.2 Cable Jacket Removal
Find the rip cord in the cable and pull to
help separate the jacket from the cable. Remove
the outer jacket and trim away all the protective
layers leaving the Central Strength Member (CSM)
and buer tubes exposed across the length of the
ring cut.
BUFFER TUBES
CSM
4.1 Entry Cable Prep
Measure 72” inches of cable and mark two spots on each end. Using the appropriate tool,
make a ring cut at both locations. Carefully make a horizontal cut from one circle cut to the other.
During the cutting process, be sure not to damage the buer tubes inside the cable.
90.000 -100.000"
(SHEATH OPENING)
BUFFER TUBES
CABLE SHEATH
(OSP CABLE)
RING-CUT LINE FOR SHEATHING
CABLE SHEATH
(OSP CABLE)
RING-CUT LINE FOR SHEATHING
ultilink
NO SHARP EDGES OR
BURRS ALLOWED
SCALE:
SIZE
CAD FILE:
DWG. NO.
A
SHEET
OF
REV.
DRAWN BY:
FRACTIONS DECIMALS ANGLES
1/32
MATERIAL:
FINISH:
DO NOT SCALE DRAWING
RING CUT VIEW
RING CUT VIEW
1:2.5
11
DESCRIPTION OF CHANGE
REV
DATE
ECN#
.XX=
.03
.XXX=
.010
1
ALL FLATS TO BE
.005
RING CUT VIEW
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY NOT
BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
m
04/27/15
RING CUT VIEW
CN
01
SEE B.O.M.
N/A
CN
04/27/15
01
N/A
INITIAL RELEASE
Figure 4.1A
4.3 Cut & Trim CSM
Measure 2” inches from each side of the ring cut locations with the exposed buer tubes
and make a mark on each side of the CSM (Figure 4.3A). Cut and trim the CSM discarding the 66”
inch section (Figure 4.3B). If using armored cable continue to 4.4, else continue to 4.8.
100.000
(SHEATH OPENING)
2.000 2.000
(AFTER STRENGTH MEMBER TRIMMING)
CENTRAL STRENGTH MEMBER
96.000"
(TRIM THIS SECTION
AND DISCARD)
2.000 2.000
BUFFER TUBES
(REMOVED FOR CLARITY)
CABLE SHEATH
(OSP CABLE)
CABLE SHEATH
(OSP CABLE)
CENTRAL STRENGTH MEMBER
ultilink
NO SHARP EDGES OR
BURRS ALLOWED
SCALE:
SIZE
CAD FILE:
DWG. NO.
A
SHEET
OF
REV.
DRAWN BY:
FRACTIONS DECIMALS ANGLES
1/32
MATERIAL:
FINISH:
DO NOT SCALE DRAWING
CENTRAL STRENGTH VIEW
CENTRAL STRENGTH VIEW
1:2.5
11
DESCRIPTION OF CHANGE
REV
DATE
ECN#
.XX=
.03
.XXX=
.010
1
ALL FLATS TO BE
.005
CENTRAL STRENGTH
VIEW
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY NOT
BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
m
04/27/15
CENTRAL STRENGTH VIEW
CN
01
SEE B.O.M.
N/A
CN
04/27/15
01
N/A
INITIAL RELEASE
100.000
(SHEATH OPENING)
2.000 2.000
(AFTER STRENGTH MEMBER TRIMMING)
CENTRAL STRENGTH MEMBER
96.000"
(TRIM THIS SECTION
AND DISCARD)
2.000 2.000
BUFFER TUBES
(REMOVED FOR CLARITY)
CABLE SHEATH
(OSP CABLE)
CABLE SHEATH
(OSP CABLE)
CENTRAL STRENGTH MEMBER
ultilink
NO SHARP EDGES OR
BURRS ALLOWED
SCALE:
SIZE
CAD FILE:
DWG. NO.
A
SHEET
OF
REV.
DRAWN BY:
FRACTIONS DECIMALS ANGLES
1/32
MATERIAL:
FINISH:
DO NOT SCALE DRAWING
CENTRAL STRENGTH VIEW
CENTRAL STRENGTH VIEW
1:2.5
11
DESCRIPTION OF CHANGE
REV
DATE
ECN#
.XX=
.03
.XXX=
.010
1
ALL FLATS TO BE
.005
CENTRAL STRENGTH
VIEW
BY
MFG
ENG
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DATE:
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN ARE CONFIDENTIAL
& PROPRIETARY TO MULTILINK AND MAY NOT
BE COPIED OR DISCLOSED TO OTHERS
WITHOUT A WRITTEN CONSENT FROM
MULTILINK. THE INFORMATION IS TO BE
PROMPTLY RETURNED TO MULTILINK UPON
REQUEST.
DATE:
DATE:
DATE:
CHECKED:
MFG ENG:
QUALITY
ENG:
m
04/27/15
CENTRAL STRENGTH VIEW
CN
01
SEE B.O.M.
N/A
CN
04/27/15
01
N/A
INITIAL RELEASE
Figure 4.3A
Figure 4.3B
Note: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the cable specication
sheet for the cable you are installing. Do not bend the cable more sharply than the minimum recommended bend
radius. Do not apply more pulling force to the cable than specied. Do not crush the cable or allow it to kink. Doing
so may cause damage that can alter the transmission characteristics of the cable; the cable may have to be replaced.

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 7
DocumentNo.020-349-20InstallGuide
Installation (Cont.)
4.5 Grounding Kit *sold separately
Allow at least 1”of the cable’s armor to
remain from the jacketing. Slowly peel back
the armor using pliers to separate the seam to
allow the wedge* (from the grounding kit, *sold
separately) to t between the buer tubes and
armor. Repeat on opposite side of ring cut.
4.4 Armored Cable
Allow at least 1”of the cable’s armor to
remain from the jacketing. Slowly peel back
the armor using pliers to separate the seam to
allow the wedge* (from the grounding kit, *sold
separately) to t between the buer tubes and
armor. Repeat on opposite side of ring cut.
CABLE ARMOR
SEAM
4.6 Connecting the Grounding Braid
Attach the grounding braid by using the
bolt as a guide. Insert the bolt through the eyelet
and using one of the supplied nuts tighten to
secure the grounding braid to the armored entry
cable. Repeat on opposite side of ring cut.
4.7 Drill Ground Lug Hole
Drill a 0.25” hole into the center of the
Optima S base indicated by the cutout on the
bottom as shown.

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 8
DocumentNo.020-349-20InstallGuide
Installation (Cont.)
4.9 Secured Grounding
Attach the grounding braid by using the
ground lug as a guide. Use the appropriate eyelet
to allow both sides of the ring cut to be mounted
in the following step. Then attach the additional
washer and nut to the ground lug to secure the
braid in place.
4.8 Insert Ground Lug
Insert the supplied ground lug with the
terminal lug on the outside of the Optima S
compressing the rubber seated gasket to the
outside of the enclosure to ensure a water tight
seal. With the long threaded end on the inside of
the enclosure, attach the ground lug to the base by
using the supplied washer and nut(s).
4.10 Install CSM Clamp
Attach the CSM clamp to the base of the
Optima S using the supplied hardware. Be sure to
install both clamps on the opposite entry ports of
the base to accommodate the ring cut. DO NOT
tighten the CSM clamp all the way down but just
loose enough to slide the CSM under the clamp.
4.11 Fiber Management Clips
Insert the included ber management
clips into the slots of the Optima S base in the
orientation shown. Ensure each clip is fully pushed
in to prevent it from falling out in later steps. Insert
2 additional ber management clips into the top
section to secure the ber pigtails into the back of
the bulkhead connectors.
Optima S Base Installation

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 9
DocumentNo.020-349-20InstallGuide
4.12 Proper Grommet Seal
Make sure each ber jacketing/entry
grommet is the appropriate size of the cable
and/or mastic tape applied to accommodate the
diameter being used. Remove the white protective
cover on the mastic tape prior to applying to
the ber and securing in the grommet. Any drop
grommets not being used MUST have a supplied
pin inserted to ensure a water-tight seal.
4.15 Fiber Routing & Attach Tie-Wraps
Route the ring cut exposed buer tubes
around the inside perimeter of the Optima S
base. Place the slack under the ber management
clips to hold in place temporary. Then using
the supplied tie-wraps insert into each ber
management clip on the lower side of the base
and tighten down enough to hold in place but not
directly damage the ber.
4.13 Install CSM & Cable Grommet
Place the ber jacketing into the
appropriate sized non-captive grommet. If
necessary build up the diameter to t within the
grommet using mastic tape. Prior to installation,
use sealant to lubricate the ber jacketing or
mastic tape as well as the outer edge of the
grommet for a proper seal. Adjust the CSM under
the CSM clamp so that the jacket is barely exposed
and the 2” of CSM doesn’t stick too far out of the
clamp as shown. Once positioned tighten the
screw of the CSM clamp to secure into place.
4.14 Secure Cable to Base
Once your ber is secured via the CSM
clamp, utilize the supplied tie wraps to secure the
ber/s to the non-captive entry ange. Tighten
the tie wrap to a “snug” position being sure to not
overtighten to bend or ex the ber out of the
grommet. Doing so will involve a water leakage to
occur.
Installation (Cont.)

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 10
DocumentNo.020-349-20InstallGuide
4.16 Buer Tube Branching
Determine the number of buer tubes
that will need to be branched o to be spliced.
Cut these select buer tubes on the exit side (full
length of the ring cut) and separate these from
the remainder buer tubes that will pass through.
Utilize lower ber management clips to secure
your “Feed Through Fiber” and upper clips to
secure your spliced bers.
4.19 Splice Tray Routing
Place the completed splice tray within
the Optima S base. Route the branched o buer
tube(s) accordingly along with how the pigtail
slack will be routed.
4.17 Attach Tie-Wraps
Using the supplied tie-wraps insert into
each ber management clip on the upper side of
the base to hold the branched o buer tubes.
4.18 Splice Input Fiber to Pigtail
Following your splicers manual, splice the
appropriate number of bers from the branched
o buer tube to that of the provided or separately
purchased pigtail. (Multilink is NOT responsible for
any damages or drastic light loss if splicing is not
performed by a trained technician following the
necessary instructions.)
Installation (Cont.)
Splicing Buer Tube to Pigtail

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 11
DocumentNo.020-349-20InstallGuide
4.20 Attach Splice Tray
With the splice tray cover still removed,
using the supplied screws secure the splice tray to
the appropriate holes located in the Optima S base.
4.21 Attach Splice Tray Cover
Before nalizing the splicing section of the
4.23 Fiber Management & Tie-Wraps
Insert the included ber management clips
into the slots of the Optima S hinged shell in the
orientation shown. Ensure each clip is fully pushed
in to prevent it from falling out in later steps. Then
using the supplied tie-wraps insert into each ber
management clip on the shell to hold the ber
pigtail.
Optima S attach the splice tray cover on the hinges
of the splice tray base. The cover ensures that the
ber is secured from the internal buer tubes from
damaging the ber itself or causing any service
disruption.
4.22 Pigtail & Branch Buer Tube Routing
Once everything has been successfully
spliced and secured into place make sure the
pigtail bers (spiral wrap shown) and the branched
o buer tube are routed following the buer
tubes below it. Using the inserted tie-wraps on
each ber management clip on the upper side of
the base tighten down enough to hold in place but
not directly damage the ber.
Installation (Cont.)
Optima S Hinged Shell Installation

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 12
DocumentNo.020-349-20InstallGuide
4.24 Pigtail Fiber Routing
Route the remaining slack of the ber
pigtail around the inside perimeter of the Optima
S hinged shell. Place the slack under the ber
management clips to hold in place temporary.
4.27 Sealing the Gap
Insert any additional grommets that are
being used for the installation in the two open
available locations. Prior to isntallation, use sealant
to lubricate the outer edge of the grommet
for a proper seal. In this case, we will use blank
grommets to seal up the opening. Ensure the
grommets are inserted into the base in the correct
orientation following the gasket over mold pattern.
4.25 Fiber Management
Using the supplied tie-wraps inserted into
each ber management clip on the Optima S shell
tighten down enough to hold in place but not
directly damage the ber.
4.26 Bulkhead Adapter(s) & Connector(s)
Remove the adapter cover and plug-in the
pigtail connectors following the universal ber
color chart. DO NOT remove all the adapter covers
at once. (Multilink is not responsible for any ber loss
that may occur if this is performed improperly.)
Installation (Cont.)
Ungrooved EdgeGrooved Edge

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 13
DocumentNo.020-349-20InstallGuide
4.28 Closing the Fiber Closure
Once everything has been completed on
the splice side of the Optima S then you are ready
close the closure rmly. Ensure the ber pigtail is
held in place so that the buer tubes do not get
pinched in closing.
4.29 Apply Sealant to the Perimeter
Before completely shutting the closure
ush, apply the supplied sealant to the gasket
perimeter of the Optima S base. This will ensure a
proper seal from various elements from entering.
4.30 Screw Down Bolts to Connect
Cover to Base
Once the sealant has been applied then
close the Optima S starting with the center bolt on
the right side of the closure. DO NOT tighten the
bolt all the way down but just enough to ensure
the two halfs start the necessary compression.
Installation (Cont.)
5 4 6
8
7
9
2 1 3

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 14
DocumentNo.020-349-20InstallGuide
4.32 Install Optidrop Fiber Connector
Remove the adapter cover from the
bulkhead. Then remove the dust cap from the
connector and insert into the adapter following
the standard ber color chart. An audible click
conrms that the drop is secured. DO NOT remove
all the adapters cover at once. Multilink is not
responsible for any ber loss that may occur if this
is performed improperly. Repeat for the number
of appropriate customer drops, if some drops are
inactive then the connections need to be inserted
into the supplied foam parking lot.
4.33
4.34 Latch Cover to Optima Shell
Once the sealant has been applied to the
gel then close the Optima S cover using the plastic
latch located on the side of the closure. When
closing the door ensure that the Optidrops follow
the grooves of the cover and the latch clicks into
place to allow for the necessary compression.
Secure each ber drop to strain relief bracket using
the supplied zip ties to prevent the ber from
moving and creating an opening in the gel.
Installation (Cont.)
4.31 Install Optidrop(s)
Open the door on the front of the Optima S
and place each Optidrop in each available groove
(up to 8). Secure each OptiDrop into the gel front
wall then slide them into the respective groove
clips. Secure each drop to the strain relief bracket
using the supplied zip ties to prevent the ber
from moving and creating an opening in the gel.
Optima S Distribution Installation
4.33 Apply Sealant to Door Gasket
Before completely shutting the closure
ush, apply one of the supplied sealant packets to
the gasket perimeter of the Optima S drop section
door. This will ensure a proper seal that prevents
various elements from entering.

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 15
DocumentNo.020-349-20InstallGuide
4.35 Hang the Optima
Now that the Optima has been latched,
proceed to hang it horizontallys with the latch on
the top left of the unit and the strain relief brackets
jutting out on the left.
Installation (Cont.)

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 16
DocumentNo.020-349-20InstallGuide
5. Accessory List
Multilink’s Optima S supports various options of grommets accommodating vast cable
diameters, additional accessories some of which are included with the Optima S, and patch &
splice options including installable kits and pigtails.
Mounting Kits
Products Description Stock ID
Standard Tap Bracket Kit 072-391-21
Aerial Tap Bracket Kit 072-579-10
Surface Mounting Kit 072-365-10
Accessory Rail Mounting Kit 072-584-10
Grommets
Products Description Stock ID
Plug Grommet 642-065-10
Round Cable Grommet
.48” Diameter 642-091-10
Round Cable Grommet
.58” Diameter 642-064-10
(4) Flat Cable Grommet 642-089-10
(4) Round Cable Grommet
3mm 642-089-20
Flat Cable Pin 10-7726
Round Cable Pin
3mm 649-261-10

Visit gomultilink.com for new product releases!
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Page 17
DocumentNo.020-349-20InstallGuide
Accessory List (Cont.)
Splice Tray
Products Description Stock ID
12-SSTP 072-394-10
1124-SSTP 072-059-20
Drop Cable
Products Description Stock ID
OptiDrop™ Custom
Flat Drop Cable Protector 649-274-10
Connectivity
Products Description Stock ID
SC/APC Duplex Adapter 10-5378
LC Quad UPC Adapter 065-239-10
NPT Fittings
Products Description Stock ID
1/2” NPT Fitting 072-567-10
Ground Lug
Products Description Stock ID
Grounding Lug 072-121-10

DocumentNo.020-349-20InstallGuide
INSTALLATION
Copyright © 2020 Multilink Inc. All rights reserved • Specifications subject to change without notice • Rev. 3/5/2020 •
Contact Us |
North America
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: engsupport@gomultilink.com
Tel: +1 440 366 6966
Fax: +1 440 366 6802
Email: engsupport@gomultilink.com
Tel: +1 440 366 6966
Mobile: +1 440 366 6802
Email: lasupport@gomultilink.com
Europe, Middle East & Africa Latin & South America
Multilink, Inc
580 Ternes Ln
Elyria, OH 44035
Tel: (440) 366-6966
Fax: (440) 366-6802
facebook.com/GoMultilink1 twitter.com/GoMultilink youtube.com/GoMultilink
Scan
QR for
website.
Surelight® Field Installable Kits
Products Description Stock ID
900µm Connector Kit 072-395-10
IP Connector Kit 072-395-50
OptiDrop™ Field Installable 072-560-10
Accessory List (Cont.)
This manual suits for next models
1
Table of contents
Other Multilink Enclosure manuals
Popular Enclosure manuals by other brands

Diablotek
Diablotek LEGEND user manual

STIEBEL ELTRON
STIEBEL ELTRON WPM-RBS Operating and installation

Antec
Antec Quiet Computing Mini Skeleton-90 user manual

HighPoint
HighPoint SSD6540M user guide

D-Link
D-Link DSM-G600 - MediaLounge Wireless G Network Storage Enclosure NAS... install guide

Kramer
Kramer MODULAR TBUS-1Axl user manual

Siemens
Siemens TH 180 AP installation instructions

Rockford Fosgate
Rockford Fosgate PUNCH PS-8 Operation manual

NAPCO
NAPCO GEM-PXCV installation instructions

TRENDnet
TRENDnet TV-H510 - datasheet

Tyco Electronics
Tyco Electronics FOSC 450 B6 installation instructions

CommScope
CommScope CHD Series quick start