Munters FH1709 User manual

1© Munters Corporation, December 2022 QM1249r0
Instruction Manual
Pipe Hanging Kit for CX74
Models: FH1709
Aerotech
Pipe
Hanging Kit
for CX Series
Circulation Fan
74” Fan
Pipe Hanging Kit
CX74 Fan with Pipe Hanging Kit

© Munters Corporation, December 2022
2QM1249r0
Pipe Hanging Kit for CX74
Instructions for Use and Maintenance
Thank You:
Thank you for purchasing a Munters FH1709 Hanging Kit. Munters equipment is designed to be the highest
performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide
many years of service.
Please Note:
To achieve maximum performance and ensure long life from your Munters product it is essential that it be installed
and maintained properly. Please read all instructions carefully before beginning installation.
Warranty:
For Warranty claims information see the “Warranty Claims and Return Policy” form QM1021 available from the
Conditions and Limitations:
• Products and Systems involved in a warranty claim under the “Warranty Claims and Return Policy” shall have
been properly installed, maintained and operated under competent supervision, according to the instructions
provided by Munters Corporation.
• Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation
or maintenance shall not be considered a defect under the Warranty.

3 Munters Corporation, December 2022 QM1249r0
Index
Chapters Page
1. Unpacking the Equipment 4
1.1 Parts List 4
1.2 Fan Dimensions 5
2. Installation Instructions 6
2.1 Assembly 6

© Munters Corporation, December 2022
4QM1249r0
1.1 Parts List
Unpacking the Equipment 1.
[A]
[B]
[C]
[D]
Each FH1707 includes:
2 – Pipe Hanger Bracket, CX74, CTD-STL, BLK
2 – Pipe Clamp Bracket, CX74, CTD-STL, BLK
1 – Hardware Package as follows:
HP1199 – FH1709 Pipe Hanging Kit
ID Qty. Cat. No. Description
[A] 8 KS1180 ⅜”-16 x 1.5” Flange Hex Bolt, ZP
[B] 24 KW3036 ⅜” Flat Washer, USS, ZP
[C] 16 KN1709 ⅜”-16 Nylock Nut, ZP
[D] 8 KS1077 ⅜”-16 x 2.5” Hex Bolt, ZP
Before beginning installation, check the overall condition of the equipment. Remove packing materials, and
examine all components for signs of shipping damage. Any shipping damage is the customer’s responsibility and
should be reported immediately to your freight carrier.

5© Munters Corporation, December 2022 QM1249r0
1.2 Dimensions
Unpacking the EquipmentChapter 1
FRONT VIEWSIDE VIEW
27”
17½”
101⅜”

© Munters Corporation, December 2022
6QM1249r0
Installation Instructions 2.
2.1 Assembly
Bolt [A]
Figure 1
Step 1
With the CX74 fan turned sideways, so the main struts are horizontal, attach a Pipe Hanger Bracket to the
brackets on each end of the fan using (4) Bolts [A], Washers [B] and Nylock Nuts [C] for each Bracket.
See Figure 1.
Washer [B]
The Pipe Hanging Kit for the CX74 is designed to mount to a NPS 3” pipe, which would be provided by the
customer or installer. The installed pipe must be capable of holding the weight of the 300 lb. fan.
Nut [C]

7 Munters Corporation, December 2022 QM1249r0
Installation InstructionsChapter 2
Step 2
Secure fan with Pipe Hanger Brackets to pipe using (2) Pipe Clamps and (8) Bolts [D], (16) Washers [B]
and (8) Nylock Nuts [C].
See Figure 2.
Figure 2
Bolt [D]
Nut [C]
Pipe Clamp
Washer [B]

© Munters Corporation, December 2022
8QM1249r0
Installation InstructionsChapter 2
Step 3
If it is desired to angle the fan down, loosen the Pipe Clamp bolts and rotate the fan to the desired angle and
then retighten the Pipe Clamp bolts.
See Figure 3.
Figure 3
10 - 15°

9 Munters Corporation, December 2022 QM1249r0
This page left blank intentionally

© Munters Corporation, December 2022
10 QM1249r0
Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66.
Munters Corporation 2691 Ena Drive Lansing, MI 48917 U.S.A. Phone +1 800-227-2376, Fax +1 517-676-7078
www.munters.us
Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada/US Munters
Corporation Lansing, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S,
Phone +45 9862 3311, India Munters India, Phone +91 20 3052 2520, Indonesia Munters, Phone +62 818 739 235, Italy Munters Italy S.p.A., Chiusavecchia,
Phone +39 0183 52 11, Japan Munters K.K., Phone +81 3 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone
+52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries
Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +34 91 640 09 02, Sweden Munters AB, Phone +46 8 626 63 00, Thailand
Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endüstri Sistemleri A.Ş, Phone +90 322 231 1338, USA Munters Corporation Lansing, MI Phone
+1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 3825 6838, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +39 0183 52 11
Pipe Hanging Kit for CX74 Fan is developed and produced by Munters Corporation, Lansing, Michigan U.S.A. 1-800-227-2376
Table of contents