SDI Box Camera Quick Guide
00P5SH061ZXSEA3
The quick guide is for quick installing and connecting the SDI Box Camera. For details, please refer to the camera’s
User Manual.
System Configuration
Connector Definition
Single Board Dual Board
DIP Switch Setting
The table below shows the definition of each DIP Switch on the Camera’s Rear Plate.
Setting
Pin Definition ON OFF
1TV System NTSC PAL
2Resolution 720P 1080P
3Frame Rate 50/60 25/30
4Reserved - -
5Reserved - -
6BNC ON OFF
Please kindly notice that while BNC is on, there will be no signal from SDI output
Item Definition Remark
APWR Power connection indication (green light)
BAUTO IRIS Connector Auto Iris Lens connector
CRESET Reset
DSDI OUTPUT SDI signal output
E↑/ ↓/ ←/ →/ ENTER OSD control key
Single Board DC12V Power connector
+AC 24V: AC_IN 1 DC 12V: DC12V
AC 24V: GND DC 12V: GND
FDual Board DC12V/AC24V
-AC 24V: AC_IN 2 DC 12V: DC12V
GVIDEO BNC output
HDIP Switch TV system/ Resolution/ Frame Rate Setup/BNC
1 ALARM_GND 5 T-
2 ALARM_IN+ 6 T+
3 ALARM_OUT- 7 R-
IAlarm I/O
4 ALARM_OUT+ 8 R+
www.ness.com.au
RECOMMENDED SETTINGS
Turn OFF switches 1-6
for correct operation.
INSTALLERS PLEASE NOTE:
Dipswitch 6 must be OFF to enable SDI output