Select in the main menu, and press the to enter the optical power meter function.
The triangular arrow indicates the current position where the cable needs to be inserted,
and the data can be updated in real time. Press return backto the main menu.
5、PoE test
Select the in the main menu, and press the to enter the POE function test. The
triangular arrow indicates the current position where the cable needs to be inserted.
Press the to return back to the main menu.
OK
If plug and unplug the cable connected to the switch, the data will be updated automatically.
(1) It will display: Non-standard/IEEE 802.3af/IEEE 802.3at, when test PoE standard.
(2) It will display: end connection method/middle jumper method/powered by 8 cores, when
judging the jumper method.
(3) It will display positive and negative and voltage of the PoE switch, when judging the
polarity.
POE
1
2
3
453.7 V DC
553.7 V DC
6
7
8
152.5 V DC
252.5 V DC
300.0 V DC
4
5
600.0 V DC
7
8
IEEE802.3af
1
2
3
452.0 V DC
552.0 V DC
6
700.0 V DC
800.0 V DC
IEEE802.3af
53.7 V DC
53.7 V DC
00.0VDC
00.0VDC
00.0VDC
00.0VDC
4-Pairs
POE POE
IEEE802.3af
4-Pairs
EndspanMidspan
EndspanMidspan
6、QC testing for crystal head
Select the in the main menu, and press the to enter the crimping test function. The
triangular arrow indicates the current position where the cable needs to be inserted, and press
the to return back to the main menu.
OK
Plug and unplug the cable testing, the result will be updated automatically. √ indicates that
the channel is normal, and X indicates that the channel is abnormal.
QCTest
1
2
3
4
5
6
7
8
X
X
X
X
X
X
X
X
Error
1
2
3
4
5
6
7
8
Correct
1
2
3
4
5
6
7
8
X
X
QCTest QCTest
Error
7、Optical power meter
OK
The optical power meter can test the optical power and the attenuation value of the light.
The white triangular arrow indicates the current selection item. From top to bottom, the top
means the unit can be switched and the bottom means the wavelength can be switched.
(1) Unit switching: can switch as dBm, dB, or mw, uw, nw
(2) Wavelength switching: Enter the option, Click OK then you can switch the wavelength
to 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm.
(3) REF Switch
REF is used to test the attenuation value of light, insert the port of the unattenuated end
under this option, long press to save the current unattenuated optical power and display
the value in the blue display area on the first line of the user area, then plug the interface
of the attenuation end into the test end, and click the OK button in this mode to switch the
user area. The blue display area on the first row displays the attenuation value or the normal
optical power data.
PoE testing : identify which pins are providing power and detect how much voltage, identify
which the type of PSE ( at/af standard )
-07- -08-