Picture Adjustment:
If will now be necessary to obtain atest pattern iri order to make further adjuftments. SEE STEPS 2to 13, as previously
described.
Check of Horizontal Oscillator Alignment:
Turn the horizontal hold control to the extreoie counter-clockwise position. The picture should remain in synchronization. Turn
channel selector switch OFF and immediately back ON again. Normally, the picture will now be out of synchronization. Turn the
control clockwise. The picture will slowly begin to synchronize, and will in one moment pull into synchronization. This should occur
when the control is approximately 90 degrees from the extreme counter-clockwise position. It should now remain in synchronization
for approximately 90 degrees additional clockwise rotation of the control. At the extreme clockwise position, the picture should again
pull out of synchronization and should show from 3'/2 to 4I/2 bars sloping downward to the right.
If the receiver passes this test and the picture is normal and stable, the horizontal oscillator is properly adjusted. Skip the
"alignment of horizontal oscillator" and proceed with "focus" adjustment.
Alignment of Horizontal Oscillator:
If in the above test, the receiver fails to hold synchronization with the hold control at the extreme counter-clockwise position or
fails to hold synchronization for at least 60 degrees of clockwise rotation of the control from the point of "pull in" it will be necessary
to make the following adjustments:
Horizontal Frequency Adjustment:
Turn horizontal hold control to the extreme clockwise position. Tune in atelevision station and adjust the "horizontal fre-
quency" trimmer (rear of chassis] until the picture is out of synchronization and shows 3^2 *° ^Vl ^°'^ sloping downward to the right.
If the trimmer has insufficient range, set the trimmer to mid position (one turn from tight) and adjust the horizontal oscillator coil L14
(consult circuit diagram] until this condition is obtained.
Horizontal Locking Range Adjustment:
Set the horizontal hold control to the extreme counter-clockwise position. Switch channel selector OFF channel and back.
Slowly turn the horizontal hold control clockwise and note the least number of diagonal bars obtained just before the picture
pulls into synchronization. If more than 4'/2 bars are present just before the picture pulls into synchronization, adjust the "horizontal
lock" trimmer (rear of chassis] slightly clockwise. If less than 3I/2 bars are present, adjust the trimmer slightly counter-clockwise. Turn
the contrast control counter-clockwise and switch channel selector OFF channel and back again. Recheck the number of bars at the
"pull in" point. Repeat this procedure until 3I/2 to 4'/2 bars are present.
Repeat the adjustments of the horizontal frequency adjustment and horizontal locking range adjustment until the conditions
specified above are fulfilled. When the horizontal hold operates as outlined in "Check of Horizontal Oscillator Alignment" the oscillator
is properly adjusted.
Height and Vertical Linearity Adjustments:
Adjust the height control on the rear of chassis until the picture fills the mask vertically. Adjust vertical linearity (rear of
chassis] until the test pattern is symmetrical from top to bottom.
Adjustment of one control will require readjustment of the other. Then adjust vertical centering control to align the picture
with the mask.
Width, Drive and Horizontal Linearity:
Turn the width control (accessible through ahole in the upper right hand corner on the rear wall of the high voltage com-
partment] to the maximum clockwise position. Adjust the trimmer "horizontal drive" (rear of chassis] to give the best degree of
brightness and linearity. Adjust the horizontal linearity control (rear of chassis] for best linearity of the right half of the picture. Readjust
the width control until the picture just fills the mask and adjust horizontal centering again (rear of chassis] to align the picture with
the mask.
Focus:
Adjust the focus control [rear of chassis] for maximum definition of the vertical wedge and the test pattern.
CHECK TO SEE THAT YOKE AND FOCUS COIL THUMB SCREWS ARE TIGHT. CHECK THAT ALL TUBES ARE
FIRMLY IN THEIR SOCKETS AND REPLACE CHASSIS IN ITS CABINET.
OLYMPIC RADIO &TELEVISION INC.
OLYMPIC BUILDING
34-01 —38th AVENUE
LONG ISLAND CITY (1), N. Y.
Or'iAi^^l Ouj\^ar's\ /^btH^"^**^ ^A«we UkcjOT^ Sc/ujHa Oincvmg^ A^J