7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg2
Weight Capacity
Warning Statements
The wall, floor or ceiling should be capable of supporting a weight of at least five (5)
times the monitor’s weight. If it cannot, the wall, floor or ceiling must be reinforced.
Proper installation procedure by qualified personnel as outlined in the installation
instructions must be adhered to Failure to do so could result in serious personal injury.
CAUTION! The entire installation instructions should be fully read and understood,
including all of the safety symbols and safety precautions before beginning installation.
The installation instructions should be read, understood and followed to prevent
personal injury or proper damage. Keep these installation instructions in an easily
accessible location for future reference.
CAUTION! The ceiling structure must be capable of supporting a maximum weight of
400 lbs. If not, the ceiling must be reinforced. Proper installation procedure by qualified
personnel as outlined in the installation instructions must be adhered to. Failure to do
so could result is serious personal injury.
CAUTION! Make sure to hold the plasma display, or projector, securely and remove it
from the mount to make the height adjustment prior to loosening the adjustment
screws. Do not remove the screws completely from the extension loosen all at once.
Loosen, remove, adjust then re-tighten the screws. Failure to do so could result in
injury and or damage to the plasma display or projector.
Indicates that the power plug is to be disconnected from the power outlet.
Safety precautions must be taken at all times.
Warning and caution in general
Maximum flat panel weight: 50lbs THE CEILING STRUCTURE MUST BE CAPABLE OF
HOLDING FIVE (5) TIMES THE WEIGHT OF THE
FLAT PANEL AND MOUNT. IF NOT, THEN THE
CEILING STRUCTURE MUST BE REINFORCED.

3
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg3
TABLE OF CONTENTS
1. WARNING .…….................................................................................................................
2. INSTALLATION TOOLS / PART LIST .…….......................................................................
3. FEATURES .……..................................................................................................................
4. CMA-01 INSTALLATION .……..........................................................................................
5. MOUNTING HARDWARE .……..........................................................................................
6. ATTACING THE FLAT PANEL TO THE CMA-01 .…….......................................................
7. TECHNICAL SPECIFICATION .……....................................................................................
8. LIMITED WARRANTY .……...............................................................................................
2
4
6
7
8
10
11
12

4
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg4
INSTALLATION TOOLS / PARTS
LIST
INSTALLATION TOOLS:
The following tools may be required depending upon your particular installation. They are not
included.
PARTS LIST:
Make sure your ORION Images product has the following hardware and components before
beginning installation. If there are parts missing and/or damaged, stop the installation and call
ORION Images at (714) 766-6300.

5
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg5
INSTALLATION TOOLS / PARTS
LIST
PARTS LIST
(
Continue
)
:

6
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg6
FEATURES
Extendable
The CMA-01 may be
attached to 1-½” standard
threaded pipe (NPT), or
one of ORION’s adjustable-
height ceiling adapters.
Please refer to the
installation instructions that
come with these adapters.
Cable Routing
Allows for easy routing of
power and signal cables.
Dynamic Viewing
360° of left or right swivel.
Radial Glide®
360° rotation and 15° of
adjustment in any direction.
VESA Compatible
Compatible with 75mm x
75mm, 100mm x 100mm,
200 mm x 100mm and
200mm x 200mm mounting
p
atterns.

7
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg7
CMA-01
Installation
Attachin
g
the CMA-01:
The desired ceiling attachment must be installed prior to performing the following steps.
zScrew the CMA-01 coupling adapter to the 1½” standard
threaded
p
i
p
e
The PRC-LA must be threaded four complete turns
before ti
g
htenin
g
down the set screw.
If you are having difficulty achieving four complete turns,
insert a screwdriver through the access hole and apply
pressure while turning the CMA-01 (see below).
zUse the M3 Allen wrench to tighten the M6 x 6mm set Use
the M3 Allen wrench to tighten the M6 x 6mm set screw
located on the side of the CMK-01 mount.
Proceed to the “Mounting Hardware”
M3 Allen Wrench
M6 x 6mm Set Screw

8
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg8
MOUNTING HARDWARE
1. Insert the Thread Depth Indicator into the thread inserts found on the bottom or
top of the flat panel.
2. Use a pencil to mark the depth of the thread insert on the Thread Depth Indicator,
as shown in Figure 1.
3. Insert the Thread Depth Indicator into the remaining thread inserts to compare and
verify their depth.
4. Locate the correct diameter screw for the thread insert.
5. Test each size of the screws provided.
If the screw you selected is longer than the mark on the Thread Depth Indicator, as shown in
Figure 2 and Figure 3, do not use this screw. The screw length must not bypass the mark.
The correct screws should thread easily into the mounting point and not pull out when
tension is applied.
Selectin
g
the Mountin
g
Hardware:

9
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg9
MOUNTING HARDWARE
Universal S
p
acin
g
Installation:
ORION Images’ Universal Spacers allow you to attach the mounting bracket to flat panels which
have recessed or uneven mounting points. Each Universal Spacer adds ¼˝to the distance
between the Adapter Plate and your flat panel.
The Universal Spacers must be stacked and
oriented as shown.
The Universal Spacers must only be installed
between the Adapter Plate and your flat panel.
The Universal Spacers will fit M4, M5, M6 and M8
screw sizes.
Universal S
p
acin
g
Installation:
1. Determine which mounting points will be
used.
2. Place your monitor face-down on a soft
and flat surface.
3. Secure the UFP-280 Adapter Plate to the
back of the monitor using the following
hardware:
zIf you are using the 200mm x 100mm mounting points,
you must use the M4 x 10mm Phillips flat head screws to
secure the UFP-280 Adapter Plate to the flat panel.
zIf you are using the 200mm x 200mm
mounting points...
...and you selected M4 screws from the “Selecting the Mounting
Hardware” section, you must also use M4 flat washers
....and you selected M5 screws from the “Selecting the Mounting
Hardware” section, you must also use M5 flat washers.
Proceed to the “Attaching the Flat Panel to the Mount”
section.

10
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg10
ATTACHING THE FLAT PANEL TO THE CMA-01
1. Insert two (2) M4 screws into the top two mounting points of your flat panel or UFP-280
Adapter Plate. Thread the M4 screws to one-half of their length into the flat panel or UFP-
280 Adapter Plate, but do not tighten the M4 screws at this time.
2. Insert the heads of the M4 screws through the keyhole slots.
3. Insert two (2) M4 screws, of the proper length for your installation, into the bottom
mounting points.
4. Tighten all M4 screws.
If you are using the UFP-280 Adapter Plate, use the B mounting points. Refer to the “Technical
Specifications” section for UFP-280 Adapter Plate mounting points.
Flat Panel without UFP-280 Adapter Plate Flat Panel with UFP-280 Adapter Plate
M4 x 10mm Screw M4 x 5mm Screw
CMA-01 Mount
Keyhole Slot
Thread Insert in Flat
Panel or Adapter
Plate
M4 Screw Partially Threaded Into
Flat Panel or Adapter Plate

11
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg11
TECHNICAL SPECIFICATIONS
All measurements are in inches [mm].
A. 75mm x 75mm VESA mounting points.
B. 100mm x 100mm VESAmounting points.
C. 200mm x 100mm mounting points. (M4 x 10mm
Phillips flat head screws only)
D. 200mm x 200mm mounting points. (If M4 screws are
used
,
M5 washers must be used as well
)

12
Installation and User’s Guide
htt
p
://www.orionima
g
es.com
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310 pg12
2Year Limited Warranty
Contact Orion Images
All Orion Images products carry a limited warranty from ship date against defects in materials
and workmanship. Orion Images is not liable for improper installation that results in damage to
mounts, adapters, display equipment or personal injury.
In the event of missing and/or damage equipment, or technical questions, the
following information can help in the completion of the installation.
Address: 7300 Bolsa Avenue, Westminster, CA 92683
Tel: 714-766-6300 / Fax: 714-766-6310
Email: [email protected]
Website: http://www.orionimages.com
Table of contents
Other Orion Rack & Stand manuals

Orion
Orion HDX110 User manual

Orion
Orion OIC WB-30 User manual

Orion
Orion EQ-13 User manual

Orion
Orion CMH-01 User manual

Orion
Orion ASTROVIEW 9822 User manual

Orion
Orion 5374 User manual

Orion
Orion CMH-01 User manual

Orion
Orion Sirius Pro AZ/EQ-G User manual

Orion
Orion 9829 User manual

Orion
Orion AZ-3 User manual