manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pegler
  6. •
  7. Kitchen & Bath Fixture
  8. •
  9. Pegler PERFORMA Danum 5150 Maintenance manual

Pegler PERFORMA Danum 5150 Maintenance manual

This manual suits for next models

4

Popular Kitchen & Bath Fixture manuals by other brands

VIGO Matte Stone VG04001 manual

VIGO

VIGO Matte Stone VG04001 manual

Hans Grohe Zenio Metro 31811000 manual

Hans Grohe

Hans Grohe Zenio Metro 31811000 manual

Kohler Contra 26448T-4 installation instructions

Kohler

Kohler Contra 26448T-4 installation instructions

Hans Grohe Croma Select S 180 Showerpipe EcoSmart... Instructions for use and assembly instructions

Hans Grohe

Hans Grohe Croma Select S 180 Showerpipe EcoSmart... Instructions for use and assembly instructions

Wickes MONO SINK MIXER instruction manual

Wickes

Wickes MONO SINK MIXER instruction manual

Grohe ALLURE manual

Grohe

Grohe ALLURE manual

Oliveri Munich MU7063C installation instructions

Oliveri

Oliveri Munich MU7063C installation instructions

Graff PHASE E-6659-LM45W Instructions for assembly and use

Graff

Graff PHASE E-6659-LM45W Instructions for assembly and use

Lefroy Brooks ZU X1-2030 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks ZU X1-2030 Installation, operating, & maintenance instructions

Moen Show House TS514 Series installation guide

Moen

Moen Show House TS514 Series installation guide

Spectrum Brands Pfister F-WK1-1 manual

Spectrum Brands

Spectrum Brands Pfister F-WK1-1 manual

Moen Chateau 4904 instruction sheet

Moen

Moen Chateau 4904 instruction sheet

Kalia KONTOUR BF1288 Installation instructions / warranty

Kalia

Kalia KONTOUR BF1288 Installation instructions / warranty

Hans Grohe Axor Starck 10133 Series Installation instructions / warranty

Hans Grohe

Hans Grohe Axor Starck 10133 Series Installation instructions / warranty

DOCOL 016115 Series installation guide

DOCOL

DOCOL 016115 Series installation guide

Perrin & Rowe Mimas 4841 Installation & user guide

Perrin & Rowe

Perrin & Rowe Mimas 4841 Installation & user guide

Rohl Perrin & Rowe Georgian Bathroom U.3712LS Installation & user guide

Rohl

Rohl Perrin & Rowe Georgian Bathroom U.3712LS Installation & user guide

baliv KI-5070 manual

baliv

baliv KI-5070 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Your Guide to the installation,
care and maintenance of
PERFORMA
Danum and
Danum DCD
Pegler Limited, St. Catherine’s Avenue, Doncaster. DN4 8DF
Telephone: 01302 560560 Fax: 01302 367661
Deck Sink Mixers
1. Remove backnuts from tails and fit tails through taps holes of bath ensuring base
rubber is trapped between bath and fitting. Tighten backnuts.
2. Ensure pipework is thoroughly flushed to remove debris before connecting to water
supplies.
Sink Pillar Taps
1. Remove backnut from tail
2. Fit tap through ware ensuring ‘O’ ring or anti rotational washer is positioned
between flange base and ware. Tighten backnut. It may be necessary to install a poly
washer (not supplies) between ware and backnut.
3. Ensure pipework is thoroughly flushed to remove debris before connecting to water
supplies.
CARE AND MAINTENANCE
To maintain the surface finishes, simply wipe occasionally with a mild detergent on soft
damp cloth Dry using soft cloth, never use abrasive cleaners or chemical household
cleaners, avoid contact with concentrated bleach. Traun products are manufactured to
the highest standards and should require little or no maintenance. In the unlikely event
of any spare part requirements, please contact your nearest stockist or the Pegler Sales
Office,
St. Catherine’s Avenue, Doncaster, DN4 8DF, telephone; 01302 560560
DANUM KITCHEN SINK MIXERS
5150 kitchen pillar taps
5525 mono sink mixers
5526 mono sink mixers + DCD
5521 deck sink mixers + DCD
5522 deck sink mixer + DCD
5150
5521 5522
5526 5525
WATER REGULATION REQUIREMENTS
It is important to ensure that the water supplies to your taps and mixers are connected
in accordance with the water
regulations (WRAS) requirements and good plumbing practice.
It is Pegler’s recommendation and good plumbing practice that the supplies of hot and
cold water to the bath mixer
should be at equal (balanced) pressures in order to provide a consistent flow. Supplies
should be from a common
source, either mains or tank fed. If supplies are not equal pressures then non return
valves should be fitted.
OPERATING PRESSURES
0.1 bar to 1.0 bar - inlet supply pressures do not have to be balanced as this is a
dualflow fitting. At higher pressure it may be necessary to reduce excessive flow rates
and splashing by the fitting of a pressure reducing valve in the supply line or stop /
servicing valves directly before the mixer tap. These stop valves also facilitate ease of
maintenance should it be necessary
Pre-installation Checks:
1. Ensure that there is sufficient space to install the product without it hampering its
operation. Ensure that when fitting the basin / bath product that the product will not
foul on the overflow. When fitting in a corner position make sure there is sufficient
clearance for the use of the handles.
2. Ensure that the outlet will protrude sufficiently into the basin / bath and will clear any
obstructions.
3. When installing the product the hot inlet should be on the left hand side and the
cold on the right hand side when viewed from the front.
INSTALLATION
Monobloc Sink Mixers
1. Screw inlet flexible tails into body and tighten up ensuring ‘O’ ring seal is firmly in
place and leak proof, securing stud to be loosely tightened.
2. Locate seal under flange (or base of monobloc).
3. Place fittings through hole in ware. Place washer over inlet tails and position on
underside of ware. Place clamping plate on threaded stud/s ensuring that stud is
positioned in the slot in the clamping plate and that the inlet tails are positioned in the
cut out. Place fixing nut onto threaded stud and tighten firmly onto base of ware /
worktop.
4. Ensure pipework is thoroughly flushed to remove debris before connecting to water
supplies.
5150
a = 50
b =1/2”
c = 99
d = 99
e = 148
5525
a = 190
b =150
5521
a = 178
b =1/2”
c = 138
d = 190
5522
a = 168
b =1/2”
c = 130
d = 168
5526
a = 168
b =147
AA