manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. position
  6. •
  7. Enclosure
  8. •
  9. position BRX-VDSL2-8 User manual

position BRX-VDSL2-8 User manual

BRX-VDSL2-8
8-pair Sealed Enclosure
Quick Start Guide
WWW.POSITRONACCESS.COM
5101 Buchan Street, Suite 220, Montreal, QC H4P 2R9 Canada
USA Toll-free: 1-888-258-4669 Tel: +1 514-345-2220
[email protected]
© Positron Access Solutions
Document 180-0172-001 R03
BRX-VDSL2-8 (8 pairs)
Summary Diagram of Typical Installation
DSLAM BRX-VDSL2-8
2-4 kft / 0.6-1.27 km from DSLAM (for 24 AWG / 0.51 mm equivalent gauge copper)
L1
Distance from DSLAM
L2
Distance to furthest CPE
Connecting the BRX-VDSL2-8
8 pairs from
the CO
8 pairs to the
subscriber (CPE)
Shielded gel-lled
24 AWG / 0.51mm cable
IMPORTANT NOTE: The BRX-VDSL2-8 unit is powered from the Sealing Current found on a standard POTS pair.
The BRX-VDSL2-8 will not work on a dry pair (line with no sealing current). Each pair of the BRX-VDSL2-8 is powered
independently with each pair requiring the presence of the sealing DC Voltage for proper operation.
You can also use the BRX Power Injector when deploying the BRX-VDSL2-8 on dry pairs (no POTS service).
Grounding
Lug
Step 1: Select the location where the BRX-VDSL2-8 will be
inserted using the BRX-VDSL2 Calculator for the longest loop
that requires amplication.
Step 2: Connect the grounding lug of the unit to a proper ground
(usually available near the splice point).
Step 3: Insert a BRX-BYPASS-TEST module in slot 1 and ensure
that both switches are in BYPASS mode.
Step 4: Connect the rst two (2) pairs to be amplied to the
rst two (2) pairs of the BRX-VDSL2-8. Make sure to match the
DSLAM pair color to the CPE pair color.
Step 5: Test for continuity between the DSLAM pair and CPE
pair at the splice point. If a pair is powered with a -48Vdc sealing
current, the corresponding LED on the BRX-BYPASS-TEST
module will be ON. If either circuit is not powered, a continuity
test will conrm that the pair is spliced properly (no open, short
or ground fault) but you will need to verify the DSLAM is able to
provide the current. If operating on a dry pair, you should use a
BRX Power Injector.
Step 6: Replace the BRX-BYPASS-TEST module with a
BRX-VDSL2-M module.
Step 7: The DSLAM and CPE will now retrain the circuit and bring
up the ADSL2+ / ADSL link with the amplied bandwidth. Note
that the performance may be limited (or capped) by a setting in
the DSLAM and/or BRAS conguration.
Step 8: Repeat steps 3 to 7 for the other three (3) slots of the
BRX-VDSL2-8 enclosure.
Document 180-0172-001 R03
Slot
#
Channel
#
Line
#
Cable Pair
Colors
11 1 White / Blue
2 2 White / Orange
21 3 White / Green
2 4 White / Brown
31 5 Red / Blue
2 6 Red / Orange
41 7 Red / Green
2 8 Red / Brown
Mounting ange on both
ends of the sealed unit
Pairs 1-8
Diagnostic LEDs

Popular Enclosure manuals by other brands

Thermaltake Versa H34 user manual

Thermaltake

Thermaltake Versa H34 user manual

NZXT GUARDIAN 921 user manual

NZXT

NZXT GUARDIAN 921 user manual

COUGAR UNIFACE S user manual

COUGAR

COUGAR UNIFACE S user manual

Pulsar ZRS2761GD installation guide

Pulsar

Pulsar ZRS2761GD installation guide

L-Acoustics L-CASE II owner's manual

L-Acoustics

L-Acoustics L-CASE II owner's manual

Premier Mounts Gearbox GB-AVSTOR5 installation instructions

Premier Mounts

Premier Mounts Gearbox GB-AVSTOR5 installation instructions

NZXT H700i quick start guide

NZXT

NZXT H700i quick start guide

Phanteks ECLIPSE PH-EC500ATG_BK installation guide

Phanteks

Phanteks ECLIPSE PH-EC500ATG_BK installation guide

Winter ONE V12 user guide

Winter

Winter ONE V12 user guide

2E GAMING CLARUS Operation guide

2E

2E GAMING CLARUS Operation guide

StarTech.com RK1219WALHM instruction manual

StarTech.com

StarTech.com RK1219WALHM instruction manual

Premio DSS316S-UN quick guide

Premio

Premio DSS316S-UN quick guide

Syba SY-ENC35028 user manual

Syba

Syba SY-ENC35028 user manual

KOLINK SATELLITE user manual

KOLINK

KOLINK SATELLITE user manual

AZZA Xander user manual

AZZA

AZZA Xander user manual

Hubbell Killark B7NFD Series INSTALLATION, OPERATION & MAINTENANCE DATA SHEET

Hubbell

Hubbell Killark B7NFD Series INSTALLATION, OPERATION & MAINTENANCE DATA SHEET

Stahl 8118 Series operating instructions

Stahl

Stahl 8118 Series operating instructions

Manhattan 130172 Quick install guide

Manhattan

Manhattan 130172 Quick install guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.