CONTENTS IMPORTANT SAFETY INSTRUCTIONS
Recommendation:
When istalling the operator, the PPA’s
specialist installer must comply with all the
instructions present on both this technical
manual and the user manual.
By using the user manual, the installer
must present all information, uses and
security items of the device to the end-user.
Prior to installing the operator, carefully
read and observe the instructions
contained herein.
- Prior to installing the operator, ensure
that the local grid power complies with
the technical data appearing on the gate’s
label;
- Do not connect the operator to the source
ofpoweruntiltheinstallation/maintenance
(or servicing) is over. Proceed the wiring of
the control unit with the control box power
switched OFF;
- After installing the operator, make sure
the gate system is placed far enough from
the sidewalk;
-The system’s power supply network
MUST include a disconnection device (not
supplied).
IMPORTANT SAFETY INSTRUCTIONS........................................................................................ 3
TECHNICAL FEATURES ................................................................................................................... 4
BASIC TOOLS NEEDED FOR INSTALLATION ............................................................................ 5
ELECTRICAL CONNECTIONS ........................................................................................................ 5
PRECAUTIONS WITH THE GATE BEFORE THE INSTALLATION............................................ 7
INSTALLING AND MOUNTING THE OPERATOR...................................................................... 7
TROUBLESHOOTING.....................................................................................................................14

4 5
TECHNICAL FEATURES
* The operator is available with ANALOG, DIGITAL or HYBRID limit switch systems. Check the model on its
carton or label.
** The maximum length is determined by the operator model, either Standard (1.5 m / ~5 ft) or Super (3
m / ~10 ft).
BASIC TOOLS NEEDED FOR
INSTALLATION
Tools needed:
ELECTRICAL CONNECTIONS
For the electrical set-up, the power grid must have the following features:
- 127 V / 220 V Power Supply;
- 5A Circuit Breakers in the Electrical Panel;
- 3/4”diameter conduits between the electrical panel and the disconnection device;
- 3/4”diameter conduits between the disconnection device and the outlet;
- 1/2”diameter conduits for (optional) external pushbuttons;
- 1/2”diameter conduits for photocells (required).
LINEMAN’S
PLIERS HACKSAW HEX NUT DRIVER SCREWDRIVER OPEN-END WRENCH
STEPLADDER
WELDING MACHINE HAMMER SPIRIT LEVEL TAPE MEASURE
TRY SQUARE ELECTRIC DRILL PENCIL ELECTRIC SANDER /
HAND GRINDER
PIVO HOME
CUSTOM PIVO HOME PIVO HOME
CUSTOM JETFLEX
PIVO HOME
JETFLEX
TYPE OF GATE
OPERATOR Swing Swing Swing Swing
MOTOR Single-phase Single-phase JetFlex JetFlex
POWER SUPPLY 127V/220V 127V/220V 127V/220V 127V/220V
RATED FREQUENCY 60 Hz 60 Hz 60 Hz 60 Hz
RATED POWER 320W/470W 370W/500W 300W/290W 350W/330W
MOTOR RPM 1740 1740 1740 5800
RATED CURRENT 2.7A/2.2A 3.1A/2.2A 3.4A/2.3A 3.6A/2.4A
REDUCTION RATIO 1:30 1:23 1:30 1:23
LINEAR SPEED 1.75meter/minute 2.3meters/minute 5.8meters/minute 7.6meters/minute
CYCLES / HOUR 20 30 30 40
PROTECTION RATING IPX4 IPX4 IPX4 IPX4
OPERATING
TEMPERATURE
-5°C/+50°C
(23°F/122°F)
-5°C/+50°C
(23°F/122°F)
-5°C/+50°C
(23°F/122°F)
-5°C/+50°C
(23°F/122°F)
INSULATION SYSTEM Class B, 130°C
(266°F)
Class B, 130°C
(266°F)
Class B, 130°C
(266°F)
Class B, 130°C
(266°F)
LIMIT SWITCH
SYSTEM Analog Analog Hybrid (Analog
and digital)
Hybrid (Analog
and digital)
MAX LEAF WEIGHT ~221lb (100Kg) ~276lb (125Kg) ~331lb (150Kg) ~386lb (175Kg)
MAX LEAF SIZE
HEIGHT = ~8.3 ft
(2.5m)
LENGTH* =
(According to each
gate operator
model)
HEIGHT = ~8.3 ft
(2.5m)
LENGTH* =
(According to each
gate operator
model)
HEIGHT = ~8.3 ft
(2.5m)
LENGTH* =
(According to each
gate operator
model)
HEIGHT = ~8.3 ft
(2.5m)
LENGTH* =
(According to each
gate operator
model)

6 7
- The cable used for the wiring must comply with the NBR NM 247-3
standards (Brazil);
- The mains cable (of an internal use product) must be a 3 x (Tri-
rated) 0.75 mm² / 500 V exible cable, according to the NBR NM
247-5 standards (Brazil);
- The mains cable (of an internal use product) must be a 3 x (Tri-
rated) 0.75 mm² / 500 V exible cable; according to the IEC 60245-
57 standards (Brazil).
The ground terminal MUST be
connected to the ground wire.
IMPORTANT
The operator must be powered through a Dierential Residual
(DR) Current device with a Nominal residual operating current not
exceeding 30 mA.
PRECAUTIONS WITH THE GATE BEFORE
THE INSTALLATION
Before proceeding with the product’s installation, some procedures must be taken:
- Check the movement (opening / closing) of the gate, before the installation;
- Check the eort required to open / close the gate. One must be able to perform it
smoothly on the entirety of its movement. In order to check such eort, move the
gate 80 cm (~2.63 ft) away from the hinge (spot where the operator exerts force to
move the gate);
- The gate must have a resistant and, as far as possible, non-deformable structure.
INSTALLING AND MOUNTING THE
OPERATOR
Before proceeding with the product’s installation, disconnect any
unnecessary cables as well as any devices or systems from the
mains power supply.
In order to install the product, follow the procedures below:
Swing operators are provided to be installed on either the right or the left side of
the gate. Therefore, in order to identify which side is it, follow the procedures:
- Observing the operator, according to the picture below, check the position of the
cable of the motor. If it is to the right, the operator is the right one. If it is to the left,
the operator is the left one.
LEFT RIGHT

8 9
In order to gure out which leaf of the gate is the left one and which is the right
one, place yourself inside the house, facing the gate. Thus, the leaf to your right is
the right one and the laf to your left is the left one.
In order to mount the operator, carefully follow the instructions below:
Step 1: The gate must close inwards. Provide an iron base (150 mm x 150 mm x
1/4”). It will be the fastening base.
Step 2: Fasten, either on the wall or on the gate column, the fastening base, about
85 to 100 mm (3.4 to 4 in) away from the gate hinge, and at the desired height to
mount the operator, according to the picture below.
Step 3: Weld the fastening base according to the instructions / pictures below.
INSTALLATION FOR OPERATORS WITHOUT MECHANICAL DELAY
INSTALLATION FOR OPERATORS WITH MECHANICAL DELAY
MEASUREMENTS FOR THE INSTALLATION OF THE BASE
Swing gate (maer)
Control board and limit
switch
Swing gate (maer)
Control board and
limit switch
Swing gate (maer)
Control board and
limit switch
Swing gate (slave)
Swing gate (slave)
Swing gate (slave)
FIRST OPTION FOR DELAY
SECOND OPTION FOR DELAY
NOTE: Minimum installation measurements (in millimeters)
NOTE: Minimum installation measurements (in millimeters)
LEFT LEAF
FASTENING
BASE
COLUMN
HINGE GATE LEAF
RIGHT LEAF
INSIDE THE
HOUSE

10 11
Step 4: Connect the gear motor to the actuator, according to the instructions /
pictures below.
Step 5: Fit the gear motor to the fastening base, tighten the M10 x 45 screw and x
it by means of a M10 hex nut (provided), according to the picture below.
FASTENING BASE
M10 X 45 SCREW
M10 NUT
COLUMN
SPIRIT LEVEL

12 13
Step 6: Then, t the fastening base to the tip of the piston, and fasten it by means
of a M10 x 45 mm screw, as well as a M10 hex nut (provided), according to the
picture below.
Step 7: With the gate closed, fully extend the piston rod and weld the fastening
base to the gate leaf.
Step 8: Adjust the stoppers and place the open / close limit switch reeds on the
rail, so that they activate once the gate leaf complete its movement. Fasten the
limit switch reeds by means of the‘3 x 6’ screws (xed on the reeds) and connect it
to the control board.
Before running the operator, one must screw the operator housing
by means of the 4 provided 3.5 x 16 mm screws).
CONTROL UNIT:
Check on the product’s lable (as seen
on the picture to the right) which is
the proper control board for this op-
erator. That done, refer to the control
board manual available to download
on www.ppa.com.br and perform all
connections and settings accordingly.
Lote:
Código:
Modelo:
Redução:
Tecnologia:
Voltagem:
Central:
Tamanho:
Montagem:
Carenagem:
Engrenagem:
M10 X 45 SCREW
PISTON ROD
FASTENING BASE
M10 NUT
LEFT LEAF RIGHT LEAF
GATE MOVEMENT
DIRECTION (INWARDS)
STOPPER
STOPPER
LIMIT SWITCH
REEDS

14
TROUBLESHOOTING
The table below contains useful information on some PROBLEMS — SYMPTOMS,
PROBABLE CAUSES AND POSSIBLE SOLUTIONS which might aect your operator.
Before intervening on the system (maintenance, cleaning), always disconnect the
product from the mains power supply.
SYMPTOMS PROBABLE CAUSE(S) ACTION(S)
Manouver fails to
start
A) No power supply
B) Open / Blown fuse
C) Gate jammed
D) Defective limit switch
A) Ensure that the power cable is
correctly inserted in the power
outlet.
B) Substitute the fuse for another
one with the same specications
C) Ensure there are no obstruction
on the gate travel
D) Substitute the (analog and/or
digital) limit switch system
Motor won't run A) Reversed wiring
B) Gate or operator jammed
A) Check the wiring
B) Change to manual mode and
check it separately
Control board
does not accept a
command
A) Blown fuse
B) No power supply
C) Defective remote control / Low
battery
D) Remote control range
A) Substitute the fuse for another
B) Ensure that the power cable is
correctly inserted in the power
outlet
C) Check and substitute the battery
D) Check the position of the
receiver's antenna and, if necessary,
try adjusting it, if you think the
signals to be weak
Motor only runs in
one direction
A) Reversed wiring
B) Reversed limit switch system
C) Defective control board
A) Check the motor wiring
B) Reverse the limit switch
connector (analog and/or digital)
C) Substitute the control board
Table of contents
Popular Engine manuals by other brands

Perkins
Perkins 2506J-E15TA Operation and maintenance manual

Saito
Saito FA-30S Golden Knight instruction manual

Lenze
Lenze g500-S Mounting and switch-on instructions

Assun
Assun AM-CL2657GAE Series product manual

Volkswagen Marine
Volkswagen Marine SDI Series operating manual

Vanguard
Vanguard 25E300 Operator's manual

Oriental motor
Oriental motor BLH Series operating manual

Ebmpapst
Ebmpapst M3G084 Disassembly instructions

Oriental motor
Oriental motor BLE23AR*S Series user manual

Oriental motor
Oriental motor PK Series operating manual

Oriental motor
Oriental motor World K Series operating manual

Oriental motor
Oriental motor K Ⅱ Series operating manual