2
TF 200.02.0026_eng
Table of Contents
1. SYMBOLS USED IN THIS MANUAL ..................................................................................................... 3
2. GENERAL SAFETY................................................................................................................................ 3
2.1 PRODUCT UNIT LABEL................................................................................................................................. 5
3. GENERAL REQUIREMENTS................................................................................................................. 6
3.1 PRODUCT INFORMATION.............................................................................................................................. 6
3.2 INTENDED USE............................................................................................................................................ 6
3.3 INTENDED OPERATOR ................................................................................................................................. 6
3.4 ESSENTIAL PERFORMANCE.......................................................................................................................... 7
3.5 NON-CLINICAL FUNCTIONS........................................................................................................................... 7
3.6 CLINICAL FUNCTIONS .................................................................................................................................. 7
3.7 PRODUCT DIMENSIONS................................................................................................................................ 7
3.8 OPERATION................................................................................................................................................ 9
4. MOUNTING INSTRUCTION ................................................................................................................. 10
4.1 INSTALLATION INTERFACES................................................................................................................... 10
4.2 CONNECTION ADAPTERS...................................................................................................................... 12
4.3 LIST OF COMPONENTS.......................................................................................................................... 13
4.4 INSTALLATION OF PRODUCT.................................................................................................................. 16
4.5 CABLE DIAGRAM .................................................................................................................................. 24
5. FUNCTIONALITY TESTING................................................................................................................. 25
6. SAFETY IN USE ................................................................................................................................... 25
7. CLEANING............................................................................................................................................ 26
8. TROUBLESHOOTING.......................................................................................................................... 26
9. MAINTENANCE.................................................................................................................................... 27
9.1 SERVICE SCHEDULE............................................................................................................................. 28
10. SPARE PARTS..................................................................................................................................... 29
11. ENVIRONMENTAL PROTECTION ...................................................................................................... 29
12. ELECTROMAGNETIC COMPATIBILITY............................................................................................. 30
12.1 SUITABLE ENVIRONMENTS................................................................................................................ 30
12.2 ADJACENT AND STACKED USE........................................................................................................... 30
12.3 CABLES........................................................................................................................................... 30
12.4 RF PORTABLE EQUIPMENT................................................................................................................ 30
13. COMPLAINTS....................................................................................................................................... 30
It is important to read this manual prior to mounting and use

3
TF 200.02.0026_eng
1. Symbols used in this manual
Warning Symbol
Indication of potentially hazardous situation. If not avoided, it can result in serious injury or
death.
Caution Symbol
Indication of potentially hazardous situation which may result in minor or moderate injury.
It may also be used to alert against unsafe practices.
Notification Symbol
This symbol is used to notify correct use and handling of the product.
2. General safety
This manual must be read and understood before use.
Always keep this manual in close proximity of the product.
The use, installation and service of this product must be in
compliance with this manual to avoid accidents and serious
personal injury.
Never use or handle this product in other ways specified in
this manual as it can result in personal safety hazards and/or
cause damage to the product.
Persons installing and/or using this product either as operator
or user should have the necessary safety information and
access to this manual.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
designated persons in order to avoid a hazard.

4
TF 200.02.0026_eng
Do not perform repairs, disassembly or assembly operations,
add-ons, re-adjustments or modification of the product
beyond what is described in this manual. These must be
carried out by Ropox or Ropox authorized personnel. Do not
perform service while in use.
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not use the product if it has defects or have become
damaged before being repaired or replaced.
If the control box makes unusual noise or smells, switch off
the mains voltage immediately.
Take care that the cables are not damaged.
Unplug the mains cable on mobile equipment before it is
moved.
The products must only be used in an environment that
corresponds to their IP protection.
The information in this manual is based on correct installation
in accordance with installation instructions for this product.
Ropox cannot be held liable if the product is used in any way
that differs from stated in this manual and/or installation
instruction.
Ropox reserve the right to amend this manual and reference
documents without prior notice.

5
TF 200.02.0026_eng
2.1 Product Unit label
This product is UKCA-marked in accordance with:
UK SI 2002 No. 618 - The Medical Devices Regulations 2002, and its amendments
UK SI 2008 No. 1597 - The Supply of Machinery (Safety) Regulations 2008, and its
amendments
This product is CE-marked in accordance with:
European Medical Device Regulation (EU)2017/745
Council Directive 2006/42/EC on machinery
Council Directive 2011/65/EU, RoHS
Manufacturer name and address
Date of production
Stock number
Serial number
Operating interval of electrically operated equipment. The use of electrical height
adjustable equipment can run at maximum 2 minutes, followed by an 18-minute
break.
Type BF applied part. The product complies with IEC 60601-1 requirements to
provide protection against electric shock.
Consult manual for important safety related information, warnings and safety
precautions.
Class II, double isolated electrical components.
Do not dispose as unsorted municipal waste. Product must be returned to a
designated recycling station.
Operating and storing temperatures may not exceed 5-40C°
Consult manual before use

6
TF 200.02.0026_eng
3. General requirements
3.1 Product information
Manufacturer
Product models
Part number
Model
Configuration
40-14770
40-14771
40-14772
40-14773
StandardLine
StandardLine
StandardLine
StandardLine
Unit without washbasin
Standard washbasin
Support washbasin
Hospital washbasin
Expected service life
5 years
MDR Class
2017/745
Class I
Applied part
classification
60601-1
Type BF applied part
MEE Class
60601-1
Class II
Height adjustment
40-14770
40-14771
40-14772
40-14773
30cm range
70 –100cm
68.5 –98.5cm
70 –100cm
Maximum user weight
according to DS/EN
17966:2016
200kg / 440lb
Power supply
230V ~50Hz
I in
Max 2.5A
Intermittence
2min use / 18min pause
IP rating
IPX6
Ambient temperature
range
-10 °C to +50 °C Transport and storage
+5 °C to +40 °C Operation
Relative humidity
20% to 80% - non-condensing
Intended environments
This product is to be used only in:
Professional Healthcare Environment
Homecare Environment
The device is not intended for use in special environments as defined by IEC
60601-1-2
Materials in contact
with patient
Washbasin
Frame
Mixer tap
Synthetic/marble composite
Welded steel tube St. 37, aluminum
Chrome
Accessories
40-14777
40-14776
Hand control
Plumbing kit
3.2 Intended use
The StandardLine washbasin is especially suitable for private homes and institutions. The height is adjusted
electrically. There are three types of washbasins to choose from so you can be sure to get the model that fit
the users best. These include a standard wash basin, one that provides support through integrated handles,
or one that’s larger in size, intended for hospital use.
3.3 Intended operator
Reading and understanding this manual will be sufficient training for an intended operator. Children under
the age of 16 or patient are not considered intended operator.

7
TF 200.02.0026_eng
3.4 Essential performance
The product does not have essential performance, as the patient and user do not experience any risk in case
of loss of product function/performance.
3.5 Non-clinical functions
Height adjusting offers better ergonomics to the user.
3.6 Clinical functions
The product does not have any clinical functions.
3.7 Product dimensions
40-14770
(30cm range)
40-14771
(Height adjustment 700-1000mm)

8
TF 200.02.0026_eng
40-14772
(Height adjustment 685-985mm)
40-14773
(Height adjustment 700-1000mm)
NB! All dimensions are in mm

9
TF 200.02.0026_eng
3.8 Operation
Standard control
The washbasin height is adjusted by means of the fixed Ropox control button
mounted in the top of the lifting unit.
The washbasin is raised/lowered by pressing the up/down symbol on the
control.
The washbasin stops moving as soon as the button is released.
Ropox hand control with cable (accessories)
As an alternative, you can use a hand control with cable. The washbasin is
operated in the same way. As soon as the button is released, the washbasin
will stop moving.
Warning!
The product should always be able to travel the full range of actuation without colliding
with objects. Failing to do so will compromise the product stability and introduce risk of
squeezing body parts.
Special care should be taken in ensuring that no children or adults are sited under the
product as severe injury from entrapment may occur.

10
TF 200.02.0026_eng
4. Mounting instruction
4.1 Installation interfaces
Construction
The wall must be made of a material suited for screw
mounting and approved for damp rooms. The hatched
area is the minimum area for reinforcement of the wall.
Tested in accordance DS/ISO 17966:2016 with the
following max. user weights:
40-14772: 200kg (440 lbs)
40-14773: 200kg (440 lbs)
40-14770: 200kg (440 lbs) (with porcelain wash basin)
Max. tensile load of upper screws
50kg/screw (110 lbs)
The washbasin is supplied with a set of screws and
rawlplugs suitable for mounting on a concrete wall. The
fitter should always consider the material, condition and
strength of the wall and use screws and rawlplugs
suitable for the specific wall type.
Plumbing
The drain is Ø32 (1 ¼”) and ends in an
Ø32x88.5° drain elbow.
The water supply ends in 2 (two) 90°
shut-off valves with ½” outside thread
pointing upwards (not included). The
maximum protrusion of the shut-off
valves and drain connection should be
max 90mm (3 ½”) to allow for the
covers.
The optimum location and orientation is
as shown in green.
It is important that all hoses for water
connection and drain are flexible to
allow the frame to move freely within
the height-adjustment range of 700-
1000mm (27 1/2” – 39 2/5”) (including
washbasin).
For purchase of adapters for connection
to various standard installations, see
”Connection Adapters –Other
Washbasins”.
Power
Recommended location of socket in wall for optimum and hidden wiring is shown in red. If a different location
is required, the cable from the control unit is 3200mm (126”).

11
TF 200.02.0026_eng
Water and drain placed in floor
If it is not possible to have the water supply and drain be placed in the wall, it is recommended to place it
within the hatched green area in the floor. The drain is Ø32.
Water and drain placed outside the lifting unit
If the water supply and the drain is placed outs-ide the lifting unit, it is recommended to make a cut-out in the
inner and outer covers, to allow water and drain to be brought inside the frame. If the height is adjusted
correctly in relation to the adjustment screws, see page 17, the height of the cut-out in the outer cover
mustn’t be greater than 27mm. The total height of the cut-out should not exceed 50mm.
The piping outside the lifting unit must be fixed, and should be brought inside the frame, as shown. Now,
connect the flexible pipes and hoses to the fixed piping. The fixed piping can be brought inside the frame
from both sides, but it is recommended to complete the installation in the right side.
50m
m
<=27m
m

12
TF 200.02.0026_eng
4.2 Connection adapters
The components illustrated below are available depending on the type of installation in the building.
Water connection adapters
Hoses from washbasin
Adapter
Installation in
room (not included)
No adapter needed
1/2"
Thread
1/2" -> 3/8"
Item no. 97001670
3/8"
Thread
1/2" -> 15mm
Item no. 97001666
15mm
Pipe
Water hose extensions
Hose from washbasin
Coupling piece
Extra hose
1/2" -> 1/2"
Item no. 97001662
1/2" x 1/2", 0.5m, steel
Item no. 97001123
1/2" x 1/2", 1m, plastic
Item no. 97001120
Drain adapters
Drain from washbasin
Adapter
Installation in
room (not included)
No adapter needed
Ø32
Ø32 -> Ø40
Item no. 97001660
Ø40
Ø32 -> Ø50
Item no. 97001661
Ø50
Drain extensions
Drain hose from washbasin
Coupler
Extra drain hose
Ø32-Ø32
Item no. 97001662
Ø32 Flex hose, 32-75cm
Item no. 97001172
Ø32 Flex hose, 40-110cm
Item no. 97001161
1/2”
Ø32
Ø32

13
TF 200.02.0026_eng
4.3 List of components
StandardLine lifting unit with washbasin
40*14770-036
Actuator bracket
1x
30-67636
Incl.
30*65550-013
96000167
Flexi legs without spindle
Adjustment screw
Ferrule
2x
40*14770-017
Alu profile 622mm
1x
40*14770-028
Bracket for washbasin
1x
40*14770-026
Alu top plate
1x
40*14770-024
Outside cover
1x
40*14770-025
Inside cover
1x

14
TF 200.02.0026_eng
97000488
Actuator
1x
97001691
CA30 controlbox
1x
97000427
Network cable for controlbox
1x
97001713
Bracket for controlbox
1x
97000476
Retaining ring
1x
40*14770-044
Incl.
95091437
97001800
40*43043-133
96000165
Mounting parts for control
Taptite screw M3x10
Control
Control cover
Strips black 3,5/140mm
1x
2x
1x
1x
2x
40*14770-041
Incl.
95011035
95180510
96000170
Mounting parts electrical
INSEX screw M10x35
Lock nut M10
Strips black 4,8/290mm
1x
2x
2x
2x
40*14770-043
Incl.
40*14770-022
30*65500-003
30*65550-005
95010814
95170508
95011025
95170510
96000810
Mounting parts frame
Top bracket
Flat steel nut actuator mounting
Flat steel nut leg section
INSEX screw M8x14
Chamfered washer M8
INSEX screw M10x25
Chamfered washer M10
Sleeve for hole Ø9
1x
1x
2x
2x
6x
6x
4x
4x
2x
40*14708-099
Incl.
95041250
95170512
96000170
97001467
Mounting parts washbasin
Bolt M12x50
Chamfered washer M12
Strips black 4,8/290mm
Mounting parts for bolt mounted wash
basin
1x
2x
4x
2x
1x
30*65550-013
96000167
Adjustment screw
Ferrule
1x
1x
97001706
Oras Saga 3910F
1x

15
TF 200.02.0026_eng
40-14776
Incl.
97001601
97001120
97001161
97001035
97001012
96000170
97001605
95091070
30*65500-008
95010612
40*14852-104
Plumbing kit for StandardLine
Prevex siphon
Connection hose - ½”x ½” 1m
Flex drain Ø32/32 pipe
32x88,5° white PP Wafix elbow HT
Nipple ½” to 3/8”
Strips black 4,8/290mm
Prevex 100mm extension
Plate screw Ø4,8x70 cross recess A2
Plate nut M6
INSEX screw M6x12
Bracket for siphon
1x
1x
2x
1x
2x
2x
2x
1x
1x
2x
2x
1x
40-15621
(For 40-14771)
Incl.
Insolation
foam pad
Standard Washbasin
1x
1x
97001582
(For 40-14772)
60cm Straight Support Washbasin
1x
40-15622
(For 40-14773)
Incl.
Insolation
foam pad
Hospital Washbasin
1x
1x

16
TF 200.02.0026_eng
4.4 Installation of product
Prior to assembly check that all parts have been provided according to the list of components. See list of
components.
Caution!
Mounting must always be carried out by qualified personnel
Warning!
Before use always make sure that mains cable and hand control cable will be able to
travel freely without the risk of squeezing or disconnecting the product as result of the
movement.
Caution!
When connected to the mains the product must be placed in a manner according to
power outlets so that the operator will be able to disconnect the product during use in
case of an emergency.
StandardLine comes partly pre-assembled.

17
TF 200.02.0026_eng
Unscrew the adjustment screws 68mm below the bracket.
Place the lifting unit on the wall and mark holes for screws. Drill holes and use the enclosed rawlplugs.
68mm

18
TF 200.02.0026_eng
Fix the unit to the wall.
If the wall is uneven, or the unit needs be moved from the wall due to skirting boards, use the spacers.

19
TF 200.02.0026_eng
Place 2x M6 nuts into the profile and fix the bracket for the siphon with 2x M6x12.
Push the siphon into the bracket and fasten the connecting pipe with strips through the two holes.

20
TF 200.02.0026_eng
Assemble drain hoses, water, and power as shown on the picture.
Alternatively, the water and drain are mounted in the floor.
This manual suits for next models
3
Table of contents
Other Ropox Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

Hans Grohe
Hans Grohe Locarno Thermostatic Trim with Volume Control and Diverter 04820 0... Installation/User Instructions/Warranty

METHVEN
METHVEN AIO BASIN MIXER installation guide

baliv
baliv KI-1080 manual

Hans Grohe
Hans Grohe AXOR Citterio 39835 Series Instructions for use/assembly instructions

DuschMaster
DuschMaster Rain II D 9636 manual

BELLOSTA
BELLOSTA Ludo 7300/1/P Installation instruction