Royal Vendors Vision Guide

Royal Vision Cooler
Operation, Service, and Parts Manual
Manufactured by
Royal Vendors, Inc.
426 Industrial Boulevard
Kearneysville, West Virginia 25430-2776 USA
Telephone +1 304 728 7056 • Toll Free in North America 1 800 931 9214 • Fax +1 304 725 4016 • www.royalvendors.com
R

Royal Vendors, Inc. • 426 Industrial Boulevard • Kearneysville WV 25430-2776 • USA
Customer Service: +1 304 728 7056 or Toll Free in North America 1 800 931 9214 • Fax +1 304 725 4016
E-mail: [email protected]
Website: www.royalvendors.com

TABLE OF CONTENTS
Safety Information ..................................................................................................................................................... 4
General Information and Setup..............................................................................................................................6
• Introduction ..........................................................................................................................................................6
• UnpackingtheCoolerandInstallingItOnLocation.................................................................................. 6
Start-Up ........................................................................................................................................................................8
• PreliminaryChecks.............................................................................................................................................8
• InitialStart-Up .....................................................................................................................................................9
RefrigerationSystemService................................................................................................................................10
• Components.........................................................................................................................................................10
• ServiceandTroubleshooting ..........................................................................................................................10
• RefrigerationSystemServiceandAnalysis ................................................................................................11
WiringDiagram.........................................................................................................................................................12
Maintenance ..............................................................................................................................................................13
RVC-027CabinetParts............................................................................................................................................14
RVC-012/RVC-010CabinetParts.........................................................................................................................16
RVC-027RefrigerationUnit...................................................................................................................................18
RVC-012/RVC-010RefrigerationUnit................................................................................................................20
RVC-027UpperLightingPanelAssembly ..........................................................................................................22
RVC-027DoorAssembly..........................................................................................................................................23
RVC-012/RVC-010DoorAssembly.......................................................................................................................24
WarrantyandCredit/ReturnPolicy ..................................................................................................................25

4 Royal Vision Cooler Operation, Service, and Parts Manual
SAFETY INFORMATION
ROYAL VENDORS’ COMMITMENT TO SAFETY
Royal Vendors is committed to safety with all of our
product designs. We are committed to notifying the
user of any possible danger involving the improper
handling or maintenance of our products. The
servicing of any electrical or mechanical device
involves potential dangers, both to those servicing
the equipment and to users of the equipment. These
dangers can occur because of improper maintenance
or usage. The purpose of this safety segment is to
alert anyone servicing Royal equipment of potentially
dangerous areas and to provide basic safety guidelines
for proper upkeep.
This service manual contains various warnings that
should be carefully read to minimize the risk of
personal injury. This manual also contains service
information to ensure that proper methods are
followed to avoid damaging the machine or making
it unsafe. It is also important to understand these
warnings provide general guidance only. Royal
could not possibly know, evaluate, or advise of all
the conceivable ways in which service might be done.
Consequently, Royal cannot predict all of the possible
dangerous results. These outlined safety precautions
are the basis for an effective safety program. Use
these safety measures, along with the service
bulletins, helpful hints, and product specication
sheets, when installing or servicing Royal equipment.
We recommend that persons servicing our equipment
maintain a similar commitment to safety. Only
personnel properly trained should have access to the
interior electrical and / or mechanical parts of the
machine. This will minimize the potential dangers
that are inherent in electrical and mechanical devices.
Royal has no control over the vender once it leaves
the premises. It is the owner or lessor’s responsibility
to maintain the vender in a safe condition. See
installation insert located in the new machine for
proper installation procedures, and refer to the service
manual for recommended maintenance procedures. If
you have any questions, please contact the Technical
Service Department at 1 800 931 9214 (outside North
America, dial +1 304 728 7056).
SAFETY REGULATIONS
• Read the safety segment before installation or
service.
• Test for proper grounding before installing the
machine to reduce the risk of electrical shock and
re.
• Disconnect the power cord from the wall outlet
before servicing the machine.
• Only fully-trained service technicians should
service the machine when it has power.
• Remove any product before moving a machine.
• Use appropriate equipment when moving a
machine.
• Always wear eye protection, and protect your
hands, face, and body when working near the
refrigeration system.
• Use only authorized replacement parts.
• Be aware of inherent dangers in rocking or tipping
a machine.
SECTION 1: ELECTRICAL HAZARDS GENERAL
ADVICE
Careless or improper handling of electrical circuits
can result in injury or death. Anyone installing,
repairing, loading, opening, or otherwise servicing a
machine should be aware of this precaution. Apply
all of the normal precautions when handling electrical
circuits, such as:
• Refrigeration servicing to be performed by
qualied personnel only.
• Unplug the vender before servicing.
• Replace electrical cords if there is any evidence of
fraying or other damage.
• Keep all protective covers and ground wires in
place.
• Plug equipment into outlets that are properly
grounded and polarized (where applicable), and
protected with fuses or circuit breakers of the
correct size.
• All electrical connections must be dry and free of
moisture before applying power.
WARNING:ALWAYSTESTTOVERIFY
PROPERGROUNDINGPRIORTO
INSTALLATIONINORDERTOREDUCETHE
RISKOFELECTRICALSHOCKANDFIRE.

Royal Vision Cooler Operation, Service, and Parts Manual 5
SECTION 2: ELECTRICAL HAZARDS
1. Servicingwithpoweroff.
For maximum safety, unplug the power cord
from the wall outlet before opening the machine’s
door. This will aid in avoiding electrical hazards.
Service personnel should remain aware of possible
hazards from hot components although electrical
power is off.
2. Servicingwithpoweron.
Some service situations may require access with
power on. Only fully-qualied service technicians
should perform power-on servicing. Particular
caution is required in servicing assemblies
that combine electrical power and mechanical
movement. Sudden movement (to escape
mechanical action) can result in contact with live
circuits and vice versa. It is therefore important
to maintain maximum clearances from both
moving parts and live circuits when servicing.
WARNINGS:
1. ONLYFULLY-TRAINEDSERVICE
PERSONNELSHOULDACCOMPLISH
SERVICINGWITHPOWERON.SUCH
SERVICEBYUNQUALIFIEDINDIVIDUALS
CANBEDANGEROUS.
2. LIGHTING CIRCUITS CAN BE HAZARDOUS.
ALWAYS DISCONNECT THE MACHINE FROM
THE WALL OUTLET BEFORE REPLACING
A BULB OR SERVICING THE MACHINE IN
THAT AREA.
NEVER USE A HOSE, PRESSURE WASHER, OR
ANY CLEANING METHOD THAT COULD
WET ELECTRICAL COMPONENTS. IF
WATER CONTAMINATION OF ELECTRICAL
COMPONENTS IS SUSPECTED, USE
QUALIFIED ELECTRICAL TESTING
EQUIPMENT AND TEST METHODS TO
ASSURE THAT THE MACHINE IS NOT A
HAZARD BEFORE APPLYING POWER FOR
ANY REASON.
This equipment is intended for the storage
and display of non-potentially hazardous
bottled or canned products only.

6 Royal Vision Cooler Operation, Service, and Parts Manual
GENERAL INFORMATION AND SETUP
INTRODUCTION
This manual contains installation, operation, and
service instructions for the Royal Vision Cooler (RVC),
by Royal Vendors, Inc. This manual also contains a
parts catalog and electrical schematic for the RVC.
UNPACKING THE COOLER AND
INSTALLING IT ON LOCATION
UNWRAP THE VENDER
Unwrap the unit and remove the padding. Examine
all packages for damage to packaging material.
Damage to external packaging may have resulted in
unit damage. Check packages for all accessories and
components, including legs, casters, and shelves. File
a claim immediately with the shipping company if the
shipment is damaged or incomplete.
PLACE THE UNIT ON LOCATION
Units are designed for indoor placement only. Provide
at least 4” (10 cm) of wall space behind the unit
cabinet and any adjacent wall or xture. Remove the
shipping skids by inserting a claw hammer, crowbar,
or similar device into the slot of each section to break
it apart. Tilt the unit slightly to remove the separated
pieces. Remove the cooler leveling legs, and place the
protective sleeve over the threads of the legs. Replace
the leveling legs with the protective sleeve in place,
and be sure the cooler is level (see following section).
The protective sleeves provide 3” (7.5 cm) clearance
under the vender for cleaning.
LEVEL THE UNIT
To provide adequate condensate drainage and proper
door alignment and operation of unit, the unit cabinet
must be level. The leveling legs are factory-installed.
Toremovetherefrigerationdeck:
Note: The refrigeration unit weighs in excess of 70 lbs
(32 kg). Use caution when lifting the unit.
1. Remove power from the vender.
2. Remove the three screws that secure the left
shroud.
3. Remove the three screws that secure the right
shroud.
4. Remove the condensor pan and clip.
5. Remove the two screws that secure the unit’s base
plate.
6. Turn the lift rods to the upright position.
7. Slide the unit approximately half-way out.
8. Unplug the unit from the main junction block.
9. Disconnect the leads to the refrigeration control,
and then pull them out of the wiring bushing.
10. Turn the lift rods all the way down.
11. Pull the unit completely out.
12. Installation of the new unit is the reverse of the
removal process. Ensure that the unit slides
within the cassette guides during installation.
Figure 1. To remove the refrigeration deck, rst pull the
lifting rods forward and turn in the direction shown.
ROYAL VISION COOLER STANDARD PARTS
Parts Factory Installed Field Installed
Unit Size
RVGVC 27
Quantity
Refrigeration Deck X 1
Shelves X 5
Shelf Clips X 20
Operation and Service Manual - - 1
Levelling Legs X 4
Lamps X 2
Leg Protective Sleeve X 4
NOTE: Parts shown are for standard units. Quantity of shelves and clips may vary based on factory-supplied options.

Royal Vision Cooler Operation, Service, and Parts Manual 7
Toleveltheunit:
The door is spring-loaded and will not function
properly without proper leveling of the cabinet. Using
an adjustable wrench, adjust the leveling legs so that
the unit sits approximately level to the oor and the
door closes properly. For best door operation, adjust
the leveling legs so that the cabinet has a 1/16” (2
mm) rake or slant from front to rear. Optional casters
are available to replace the leveling legs.
INSTALL THE SHELVES
Product shelves and a bag containing shelf support
clips are packed inside the unit. Refer to the table
below to verify the quantity of shelves and shelf
supporting clips.
Toinstalltheshelves:
1. Determine the proper location for the shelf clips.
Refer to the numbers on the pilaster to ensure
that all clips are properly located.
2. Insert the top tab of the shelf clip into the desired
hole of the pilaster. The retaining tab should be
facing upward, as shown in Figure 2.
3. Rotate the clip downward and insert the bottom
tab into the appropriate hole on the pilaster.
If necessary, squeeze the clip slightly during
installation.
4. Install all remaining clips as described above.
5. Install the shelves onto the clips so that the
product retention bars are facing upward. Be
careful not to dislodge the clips during shelf
installation.
6. Shelves must be placed so that the retaining tab
on the shelf clip captures the shelf, as shown in
Figure 3.
7. Before loading the shelf, ensure that the shelf is
resting on each of the four clips and that the clips
are installed as shown in Figures 2 and 3.
CONDENSATE DISPOSAL
The evaporator drain pan is located in the base of the
refrigeration deck. Airow in the deck compartment
hastens condensate evaporation so that external drain
plumbing is not required.
DANGER
Before servicing the unit, disconnect electrical
service. Failure to do so could result in electrical
shock or electrocution and could cause personal
injury or death!
WARNING
Do not overload the shelves. The unit is
designed to use all the shelves provided,
installed in equally-spaced conguration.
Failure to install shelves correctly could result in
personal injury or damage to the unit. If fewer
shelves or a different installation conguration
is desired, contact the manufacturer to ensure
that shelf overloading will not occur.
WARNING
Improper shelf clip installation may cause shelf and /
or product to fall, which could result in personal injury
or damage to the unit.
TOP TAB
FULLY INSERTED
INTO SLOT
BOTTOM TAB
FULLY SEATED IMPROPERLY INSTALLED
CLIP (UPSIDE DOWN)
RETAINING TAB
SHELF CLIP
TOP TAB
BOTTOM TAB
PROPERLY INSTALLED CLIP
a79-5
Figure 2. Shelf clip installation.
PRODUCT
RETENTION BAR
SHELF
RETAINED
BY TAB
PILASTER
a79-6
Figure 3. Proper installation of the shelf on the clip.

8 Royal Vision Cooler Operation, Service, and Parts Manual
START-UP
PRELIMINARY CHECKS
Bi-pinuorescentlampinstallation/
verication
Before applying power to the unit, verify that all
lamps have been properly installed and are fully
engaged in the lamp holders. The RVC 27 has two
lamps, one in the signboard and one inside the cooler.
To achieve proper lamp engagement, rotate the lamp
90 degrees from its insertion position until it snaps or
clicks into place.
On units without safety shields, visually verify proper
lamp installation by checking the identication mark
on the end of the bulb. If the bulb has been properly
installed, the mark will be centered between the
halves of the lamp holder. (Refer to Figure 4.)
On units with safety shields, the identication mark
cannot be seen. Verify manually that the lamp has
been rotated and locked into place. (Refer to Figure 5.)
CAUTION
Improperly installed lamps may cause damage
to the lighting circuit. Royal Vendors will not
be responsible for equipment or component
failures or other damages that arise from
improper lamp installation.
BI-PIN LAMP END IDENTIFICATION MARK
Properly installed lamp without shield. Verify
identification mark is positioned as shown.
Figure 4. Installation of lamp without safety shield.
PINS MAY NOT BE VISIBLE IN
ACTUAL INSTALLATION
Properly installed lamp with shield.
Requires manual verification that
lamp has been rotated and locked
into place.
Improperly installed lamp with
shield. Note that pins have not
achieved full 90° rotation.
a79-8
Figure 5. Installation of lamp with safety shield.

Royal Vision Cooler Operation, Service, and Parts Manual 9
ElectricalSupplyandConnections
Check to be sure that the electrical service to the unit
meets all local and national electrical codes. Unit
electrical data is shown on the unit data label, located
on the inside of the cabinet in the upper left-hand
corner. Review this label before initiating electrical
service. The voltage range of the power supply to the
unit should be 105 to 125 volts. Refer to the table
below for unit data.
NOTE: Other motors or heavy appliances should not
be used on the same circuit with the cooler.
INITIAL START-UP
PowerSupply
Connect the unit to the power supply. Check to verify
that the compressor, lamps, and fans are running.
IMPORTANT: Low line voltage is often the cause of
service complaints. Check to see that the line voltage is
within the specied range with the unit running.
TemperatureControl
The temperature control adjustment knob is located
in the front right of the refrigeration deck. The dial
is factory-set at position “5”, which should maintain
product at approximately 38° F (3.5° C). For colder
temperature, turn the adjustment knob clockwise.
Adjust the temperature in small increments until the
desired cabinet temperature is reached.
DANGER
Before servicing the unit, disconnect electrical
service. Failure to do so could result in electrical
shock or electrocution and could cause personal
injury or death!
CAUTION
If an extension cord is necessary, use only
the three-wire grounding type. The use of
ungrounded cords or an overloaded circuit voids
the compressor warranty.
CAUTION
Allow 24 hours between temperature control
adjustments. Excessive tampering with the
temperature control could lead to service
difculties.
TEMPERATURE ADJUSTMENT KNOB
Figure 6. Temperature control adjustment knob location.
UNIT DATA
UNIT RVC-027
Voltage AC
Nominal
Range
115
105-125
Frequency 60 Hz
Total Amps 8
Refrigerant Type
Charge Amount
R134a
6.5 oz. (0.18 kg)
Design Pressure
High Side (psig)
Low Side (psig)
300
156
Set at position “5”, product should
be maintained at a temperature of
about 38° F (3.5° C). Turn the knob
clockwise for colder temperature.
Thermostat set position

10 Royal Vision Cooler Operation, Service, and Parts Manual
REFRIGERATION SYSTEM SERVICE
COMPONENTS
The Royal Vendors Cooler refrigeration system
consists of a hermetically-sealed compressor and
nned evaporator and condenser coils.
Condenser
The condenser has nned coils which assist in
removing heat from the refrigerant. The condenser
requires periodic cleaning for maximum efciency.
CondenserFanMotor
The condenser fan motor assembly is mounted
between the condenser and the compressor. Air is
drawn through the condenser, over the body of the
compressor, and out the rear of the unit compartment.
The motor is wired to cycle with the compressor, but it
will continue to operate should the compressor cut out
on the overload. The motor is permanently lubricated;
therefore, oiling is not required or recommended.
Drier
The drier is installed in the system just before the
capillary tube. The drier traps minute particles of
foreign material and absorbs any moisture in the
system.
LiquidControlandHeatExchanger
Liquid refrigerant control to the evaporator of the
system is accomplished by the use of a capillary tube.
This capillary tube is soldered to the suction line to
form a heat exchanger, which subcools the liquid
refrigerant to maintain high efciency within the
system.
SERVICE AND TROUBLESHOOTING
RefrigerationDeckRemoval
Note: The refrigeration unit weighs in excess of 70 lbs
(32 kg). Use caution when lifting the unit.
1. Remove power from the vender.
2. Remove the three screws that secure the left
shroud.
3. Remove the three screws that secure the right
shroud.
4. Remove the condensor pan and clip.
5. Remove the two screws that secure the unit’s base
plate.
6. Turn the lift rods to the upright position.
7. Slide the unit approximately half-way out.
8. Unplug the unit from the main junction block.
9. Disconnect the leads to the refrigeration control,
and then pull them out of the wiring bushing.
10. Turn the lift rods all the way down.
11. Pull the unit completely out.
12. Installation of the new unit is the reverse of the
removal process. Ensure that the unit slides
within the cassette guides during installation.
DANGER
Before servicing the unit, disconnect electrical
service. Failure to do so could result in electrical
shock or electrocution and could cause personal
injury or death!

Royal Vision Cooler Operation, Service, and Parts Manual 11
REFRIGERATION SYSTEM SERVICE AND ANALYSIS
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Compressor will not start; does
not hum.
1. Line cord not plugged in.
2. Temperature control stuck in open
position.
3. Wiring improper or loose.
1. Plug in the cord.
2. Repair or replace temperature
control.
3. Check wiring against schematic.
Compressor will not start; hums
but trips on overload protector.
1. Low voltage to unit.
2. Start capacitor defective.
3. Improperly wired.
1. Determine reason and correct.
2. Replace the capacitor.
3. Check wiring against schematic.
Compressor starts but does not
switch off or start winding.
1. Low voltage to unit.
2. Run capacitor defective.
3. Compressor motor winding is
defective or shorted.
1. Determine reason and correct.
2. Replace the capacitor.
3. Determine cause, correct, and
replace compressor.
Compressor starts and runs,
but short-cycles on overload
protector.
1. Additional current passing through
overload protector.
2. Low voltage to unit.
3. Overload protector defective.
4. Run capacitor defective.
5. Excessive discharge pressure.
6. Compressor too hot.
1. Check wiring schematic. Check
for added fan motors, pumps, etc.,
connected to wrong side or protector.
2. Determine reason and correct.
3. Check current and replace
protector.
4. Replace the capacitor.
5. Check ventilation, restrictions
in cooling medium, restrictions in
refrigeration system.
6. Check airow across condenser.
Unit runs but short-cycles. 1. Overload protector.
2. Cold control.
3. Bad refrigeration unit.
1. Check wiring schematic for correct
wiring.
2. Change cold control setting.
3. Replace the refrigeration unit.
Unit operates too long or
continuously.
1. Dirty condenser.
2. Cold control contacts stuck or
frozen.
3. Evaporator fan not working.
4. Bad refrigeration unit.
1. Clean condenser.
2. Replace cold control.
3. Check evaporator fan wiring. If
correct, replace evaporator fan.
4. Replace refrigeration unit.
Cabinet temperature too high. 1. Cold control setting too high.
2. Inadequate cabinet air circulation.
3. Dirty evaporator.
4. Dirty condenser.
5. Inadequate air circulation at
refrigeration deck.
1. Reset cold control.
2. Check evaporator fan motor.
3. Clean evaporator.
4. Clean condenser.
5. Check condenser fan motor.
Cooler freezing beverages. Cold control set incorrectly. Reset cold control.
Unit is noisy. 1. Loose parts or mountings.
2. Tubing rattling.
3. Bent fan blade causing vibration.
4. Fan motor bearings worn.
1. Find and tighten.
2. Reform to be free of contact.
3. Replace blade.
4. Replace motor.

12 Royal Vision Cooler Operation, Service, and Parts Manual
WIRING DIAGRAM
LINE RETURN (SMOOTH) BLACK
GREEN
WHITE
MAINS
JUNCTION
BLOCK
EVAPORATOR
FAN
COMPRESSOR
FAN
COMPRESSOR
ELECTRONIC
TEMPERATURE
CONTROL
REFRIGERATION CASSETTE
GROUND
NEUTRAL
LINE
MAINS
POWER
IN
RED
BLACK
LIGHT
SWITCH
ON
OFF
BLACK
1 2 3 4 5 6
NEUTRAL (RIBBED)
LINE (RIBBED)
NEUTRAL (SMOOTH)
1
2
3
4
1
2
3
4NEUTRAL (SMOOTH) NEUTRAL (SMOOTH)
NEUTRAL (RIBBED)
LINE (SMOOTH)
LINE (RIBBED)
1
2
1
2
BLACK
WHITE BALLAST
LAMP
BLUE
BLUE
BLUE
RED
RED
RED
RED
1
2
BLACK
WHITE BALLAST BLUE
BLUE
RED
RED
RVC 27(SINGLE LAMP), 12 & 10
LIGHT
SWITCH
ON
OFF
LED
LED
V+
V-
V+
POWER
SUPPLY
N L V-V+
V-
LIGHT
SWITCH
ON
OFF
POWER
SUPPLY
N L V-V+
LED
V+V-
INPUT DC 24V
INPUT DC 24V
OPTIONAL 24VDC LED CONFIGURATIONS (1 & 2 LAMP)
LAMP ORIENTATION MAY VARY BY MODEL
LAMP
LAMP
At right: Units with serial numbers beginning
2013 and after.
1 2 3 4 5 6
REFRIGERATION CASSETTE
EVAP.
FAN
COND.
FAN
COMP.
ELECTRONIC
TEMP.
CONTROL
LINE
NEUTRAL
BLACK
MAIN
JUNCTION
BLOCK
MAINS
POWER
IN
WHITE
GREEN
LINE
GROUND
NEUTRAL
NEUTRAL
LINE
RED
BLACK
NEUTRAL
NEUTRAL
LINE
LIGHT
SWITCH
ON
OFF
1
2
1
2
BLACK
WHITE BALLAST
LAMP
LAMP
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
BLACK
RED
BLACK
RED
At left: Units with serial numbers beginning
2013 and before.

Royal Vision Cooler Operation, Service, and Parts Manual 13
MAINTENANCE
LAMP REPLACEMENT
Remove the lamps by rotating 90 degrees to align
the lamp pins with the holder slots. Refer to “Bi-pin
uorescent lamp installation / verication” on page 8
for further information on lamp removal.
CONDENSATE REMOVAL
The evaporator drain pan is located in the base of the
refrigeration deck. Airow in the deck compartment
hastens condensate evaporation so that external drain
plumbing is not required. In general, this renders the
condensate pan maintenance-free.
CONDENSER
The condenser should be inspected periodically for
accumulation of debris, which should be removed. A
vacuum cleaner or wire brush can be used to remove
debris. Be careful to not bend the condenser ns.
CABINET EXTERIOR
Cabinets should be cleaned with a solution of mild
soap and water or mild household cleaner. Do not use
caustic soap or abrasive cleaners, since these might
damage the cabinet nish. Do not use steel wool, or
rusting might occur.
INTERIOR SURFACE
The inside of the cabinet is coated with powder-coat
paint. To clean, use a mild soap and water solution or
mild household cleaner.
UNDERNEATH COOLER
Underneath the cooler can be cleaned by hand or by
using an appropriate cleaning tool up to 1 1/2” thick.
Use a mild soap and water solution or mild household
cleaner.

14 Royal Vision Cooler Operation, Service, and Parts Manual
RVC-027 CABINET PARTS
18
4
5
6
9
11
12
17
2
73
8
13
16 15
14
19
20
10
1
22
25
24
23

Royal Vision Cooler Operation, Service, and Parts Manual 15
RVC-027 CABINET PARTS
Item Description Part Number
1 Key Hole Pilaster Rear, 54” ...................................................................................................................... 810338
2 Front Refrigeration Cover, 027, Standard.................................................................................................370017
- Health Timer Cooler ............................................................................................................................... 370037
3 Key Hole Pilaster Front, 48” ..................................................................................................................... 810337
4 Refrigeration Panel Assembly Foamed .................................................................................................... 370232
5 Air Duct Back, 027.................................................................................................................................... 370000
6 Air Duct Cover Rear ................................................................................................................................. 370001
7 Leveling Leg, Extended ............................................................................................................................ 803117
8 Pilaster Clip .............................................................................................................................................. 810339
9 Lamp Bracket Panel Right........................................................................................................................ 370004
10 Open / Closed Bushing, 1/2” .................................................................................................................... 916120
11 Lamp Bracket Panel Cover Right ............................................................................................................. 370005
12 Lamp Switch Mounting Bracket ................................................................................................................370006
13 Switch, Black ............................................................................................................................................ 835027
14 Sems Screw, #8-32 x 3/8” ........................................................................................................................ 901011
15 Lampholder, Fluorescent Lighting ............................................................................................................ 842565
- LED Lighting........................................................................................................................................... 842578
16 Lamp, 48”, Fluorescent.......................................................................................................................... See Note
- LED ........................................................................................................................................................ 841041
17 Lamp Bracket Panel Left .......................................................................................................................... 370007
18 Lamp Bracket Panel Cover Left................................................................................................................ 370008
19 Screw, Pilaster Locator............................................................................................................................. 902048
20 Rivnut, 1/4”-20 .......................................................................................................................................... 908024
21 Thermometer (not shown) ........................................................................................................................ 812421
22 Fan Screen Cover .................................................................................................................................... 370010
23 Shelf, 30” x 30” ......................................................................................................................................... 811072
24 Shelf Filler.............................................................................................................................................. See Note
25 Leveling Leg Protective Sleeve ................................................................................................................ 915753
• Safety Sleeve Tube Protector, 48” Lamp.................................................................................................. 816168
• Main Wiring Harness ................................................................................................................................ 842707
• Switch, On-Off .......................................................................................................................................... 835027
• Harness, Line, to Switch and Ballast ........................................................................................................842695
• Wiring Cover, with Hole ............................................................................................................................370237
• Wiring Cover, without Hole .......................................................................................................................370240
NOTE: This part is not available as a purchase item from Royal Vendors.

16 Royal Vision Cooler Operation, Service, and Parts Manual
RVC-012 / RVC-010 CABINET PARTS
1
2
3
4
65
7
8
10
9
11
12
13
14
15 16
17
18

Royal Vision Cooler Operation, Service, and Parts Manual 17
RVC-012 / RVC-010 CABINET PARTS
Item Description Part Number
1 Thermometer ............................................................................................................................................ 812421
2 Shelf, 24” x 24” ......................................................................................................................................... 811076
3 Key Hole Pilaster, RVC-012 (42”)............................................................................................................. 810345
- RVC-010 (34”) ........................................................................................................................................ 810348
4 Fan Screen Cover .................................................................................................................................... 371309
5 Front Refrigeration Cover .........................................................................................................................371002
6 Leveling Leg, Extended ............................................................................................................................ 803117
7 Air Duct Back, RVC-012 ...........................................................................................................................371000
- RVC-010................................................................................................................................................. 372000
8 Ballast....................................................................................................................................................... 838050
9 Air Duct Bottom ........................................................................................................................................ 371001
10 Lamp Harness Channel, RVC-012 (62”) .................................................................................................. 371004
- RVC-010 (54”) ........................................................................................................................................ 372001
11 Fan Screen ............................................................................................................................................... 371307
12 Pilaster Clip .............................................................................................................................................. 810339
13 Lamp...................................................................................................................................................... See Note
14 Lampholder............................................................................................................................................... 842565
15 Switch, Black ............................................................................................................................................ 835027
16 Lamp Panel .............................................................................................................................................. 371003
17 Fan Screen Support ................................................................................................................................. 371313
18 Evaporator Air Block ................................................................................................................................. 371312
• Leveling Leg Protective Sleeve ................................................................................................................ 915753
• Main Wiring Harness ................................................................................................................................ 842063
NOTE: This part is not available as a purchase item from Royal Vendors.

18 Royal Vision Cooler Operation, Service, and Parts Manual
RVC-027 REFRIGERATION UNIT
29
28
26
30
27
31
32
17
11
12
10
2
16
23
3
22
24
15
7
17
6
41
40
35
36
37
21
1
38
18
20
39
42
9
8
4
14
10
5
25
33
13
19
34

Royal Vision Cooler Operation, Service, and Parts Manual 19
Item Description Part Number
• Refrigeration Assembly (includes items 1—36 below) ............................................................................. 370440
1 Refrigeration Base Plate........................................................................................................................... 370401
2 Compressor, 1/3+ HP ............................................................................................................................... 819042
3 Condensor Shroud ................................................................................................................................... 370419
4 Condensor, Upright................................................................................................................................... 820007
5 Condensor Top ......................................................................................................................................... 370426
6 Guide Plate............................................................................................................................................... 370416
7 Guide Plate Angle..................................................................................................................................... 370417
8 Refrigeration Control Mounting Bracket ................................................................................................... 370432
9 Refrigeration Control Cover...................................................................................................................... 370434
10 Bushing..................................................................................................................................................... 916071
11 Screw, #8 x 3/4”........................................................................................................................................ 902022
12 Expansion Nut, #8 .................................................................................................................................... 906054
13 Temperature Sensor Mounting Bracket .................................................................................................... 370433
14 Cold Control, Electronic............................................................................................................................ 822077
15 Condensor Fan Motor............................................................................................................................... 839010
16 Condensate Plan ...................................................................................................................................... 815368
17 Screw, #8-32 x 3/8”................................................................................................................................... 901011
18 Condensate Pan Clamp ........................................................................................................................... 370430
19 Cable Clamp............................................................................................................................................. 916014
20 Condensor Fan Blade............................................................................................................................... 810014
21 Cable Tie, 5”, Nylon, Black .......................................................................................................................916063
22 Grommet, Compressor ............................................................................................................................. 916015
23 Grommet Plug .......................................................................................................................................... 815017
24 Compression Clip ..................................................................................................................................... 914002
25 Sealer Gum, 3” x 1/2” x 1/16” ................................................................................................................... 829003
26 Evaporator Fan......................................................................................................................................... 839036
27 Evaporator Mounting Bracket, Bottom...................................................................................................... 370413
28 Evaporator ................................................................................................................................................ 820002
29 Evaporator Box Foamed Assembly .......................................................................................................... 370402
30 Evaporator Fan Mounting Plate................................................................................................................ 370412
31 Guide Angle Right..................................................................................................................................... 370414
32 Guide Angle Left ....................................................................................................................................... 370415
33 Gasket, Evaporator Box ........................................................................................................................... 815748
34 Gasket, Center Evaporator Box................................................................................................................ 815749
35 Condensor Bafe...................................................................................................................................... 370418
36 Rod Clamp................................................................................................................................................ 370422
37 Base Plate ................................................................................................................................................ 370205
38 Cassette Guide......................................................................................................................................... 370222
39 Refrigeration Box Lift Rod Left ................................................................................................................. 811073
40 Refrigeration Box Lift Rod Right ............................................................................................................... 811077
41 Lift Rod Bracket ........................................................................................................................................370420
42 Condensor Bafe Left............................................................................................................................... 370428
RVC-027 REFRIGERATION UNIT

20 Royal Vision Cooler Operation, Service, and Parts Manual
RVC-012 / RVC-010 REFRIGERATION UNIT
16
22
1
10
15
11
17
4
25
6
24
23
7
14
9
2
12
19
21
20
13
5
8
18
3
35
38
36
34
28
32
30
39
27
37
29
31
33
26
Table of contents