43
65
DA NGER OF
EL ECTRI CAL
SH OCK
WARNING
!
WELL VENTILATED PLACE
Please make more than 10cm space between
cooler and wall. If there are no space, cooling
capacity can drop down.
If installation in a damp location is
unavoidable, also install an electrical
leakage circuit breaker. If no electrical
leakage circuit breaker is installed,
electrical shock could result.
PR OHIBI TED DIS CONNE CT
PO WER COR D
PL UG FROM
WALL OUTLET
Never climb onto the unit. The top glass
door could break and cause material
damage or injury.
Disconnect the power cord plug from the
wall outlet before moving the unit and
make sure that the power cord is not
damaged during transport. A damaged
power cord could result in electrical shock
and/or fire.
Grasp the handle when closing the door.
Holding at other positions could result in
pinched fingers and injury.
Do not push hand against or apply
excessive force to glass surfaces as the
glass could break and cause injury.
When disconnecting the power cord plug
from the wall outlet, hold at the plug main
body close to the outlet. Pulling the cord
could cause wire breakage, possible
resulting in overheating and fire.
Make sure that the unit does not tip over
or fall when it is moved. A falling unit
could cause serious injury.
Do not throw items onto the shelves and
do not place items totaling more than 50kg
on each shelf. The shelf could fall down,
possibly cause injury.
Be sure attach and secure shelves
correctly. An improperly attached shelf
could fall down and cause injury.
DO N'T PINCH
FI NGERS
PR OHIBI TED
DO N’T TOUCH
HOW TO USE
BEFORE USE
WAIT 5 MINUTES OR MORE BEFORE RE-STARTING
TEMPERATURE ADJUSTMENT
DRAIN TRAY
EFFICIENT USE
Remove shipping package, tape, etc and leave doors open ventilation for a while.
The unit is cleaned before shipment. However, clean the compartment interior once after delivery
Please insert power supply plug into the wall outlet, single-phale to cat voltage.
Allow the unit to operate for about 1 hour to cool the compartment before placing items in the cooler
Restarting the unit immediately after it has been turned off may cause fuses to blow and activate the
circuit-breaker, the compressor may be overloaded, and/or other damage may occur
The temperature controller is well set at the factory.Do not change the settings of the temperature
controller without the professional instructions.
Defrosting is performed automatically and drain water is collected in the drain tray.
If there is the plastic water tray, please collect the defrosting water with it and pull over the water tray
periodically.
Please follow the below instruction, you could save energy.
To prevent cold air from escaping, open and close the door quickly and keep the door opened for as short
a time as possible.
Please install the unit in the place which is well-ventilated.
PLACING ITEMS IN THE EQUIPMENT
Pay attention to the following points:
Do not put the items beyond the loading line.
Please do not display goods on the bottom. Please put goods on the shelf.
CLEANING
To prevent any electrical shock hazards , always disconnect the power cord plug from the wall outlet
before cleaning.
WARNING
!
EXTERIOR AND COMPARTMENT
Wipe with a soft, dry cloth. If very soiled, wipe with a cloth that has been moistened with a detergent.
Then wipe with a cloth that has been dipped in water.
WARNING: Do not splash water directly onto the equipment and do not wash with water. Short-circuit and
electrical shock could result.
WARNING
!
Clean the cooler regularly to keep it clean at times.
Never use polishing powder, soap powder,
benzene,Oil or hot water as these will damage the
painting and Plastic components
CHECKS
To ensure the safety, perform the following checks after cleaning.
Is the power cord plug firmly inserted into a dedicated wall outlet? Confirm that the plug is not
abnormally hot.
Check the power cord for cracks and damage. Should the slightest irregularity be observed, contact the
dealer from whom you purchased this unit or our customer’s service.
In case the unit shows operating problems,
check the following prior to calling the authorized service company:
SYMPTOMS
The unit is not
operating
POSSIBLE CAUSE SOLUTION
Not reaching
desired
temperature
Abnormal noises
Water on the floor
Faulty electrical contact
Poor electrical power
Thermostat setting "0"
Unit is exposed to direct sun light
Thermostat is not properly adjusted
Clogger condenser
Blocked grills
Door not properly closed
Products poorly distributed
or excess product load
For Models with electronic
temperature controller,indicates E0 or E1
The unit is not properly level
Friction with other objects
Drain hose is outside of the drain pan
Verify electrical connections
Check the power connection and electrical outlet
Change the thermostat setting to a higher number
Relocate the unit to a shaded area
Adjust the thermostat setting to a higher number
Review Maintenance instrutions listed in the manual
Clean the grills of any debris collected
Check the leveling of the unit and door seal
Redistribute the product load according
Start instrutions
Unplug the unit from the outlet.If the error
continues,contact an authorized service
technician
Level the unit following the Installation instructions
Move the unit and avoid contact with other objects
Lovate the hose in the drain pan
WARRANTY & SERVICE
Warranty is valid for one year from the date of purchase.
The warranty covers defective parts and workmanship.The
following items are not covered under warranty:
1.Loss of products.
2.Damages caused by transportation.
3.Damages caused by modifications made by
unauthorized individuals.
4.Fluorescent lights, glass parts or plastic components.
5.Worn out plugs or defective electrical components.
6.Maintenance of the unit.
Warranty is valid showing the purchase receipt.
We offer a professional service network which offers the
necessary technical support for your unit.
If there is no plastic water tray, the defrosting water is evaporated automatically.