Sampo SC-29FAS User manual

SAMPO
SERVICE MANUAL
SC-29FAS
1、Caution………………………………………………………………………2
2、Specification…………………………………………………………………6
3、Alignment Procedure ………………………………………………………9
4、Block Diagram …………… ………… ……………………………… 21
5、Schematic Diagram …… ……………………… ………………………22
6、IC Brief Introduction ………… …… …… ……… ……………………27
7、PCB Layout ……………………… ……… ……………………………29
8、Explode View Diagram ………………… ………………………………31
9、BOM list………………………………………………………………………32
This manual is the latest at the time of printing, and does not
include the modification which may be made after the printing, by
the constant improvement of product

WARNING: TOREDUCE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
The lighting flash with arrowhead symbol, with an equilateral triangle is intended to
alert the user to the presence of uninsulated voltage within the products
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
the person.
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
CAUTION:
Use of controls, adjustments or procedures other than those specified herein may result in
hazardous radiation exposure.
CAUTION
RISKRISK OFOF ELECTRIELECTRICC
SHOCKSHOCK DODO NOTNOT OPEN.OPEN.
2
dangerous
1、

3
FOR YOUR PERSONAL SAFETY
1. When the power cord or plug is damaged or frayed, unplug this television set from the wall outlet and refer servicing to
qualified service personnel.
2. Do not overload wall outlets and extension cords as this can result in fire or electric shock.
3. Do not allow anything to rest on or roll over the power cord, and do not place the TV where power cord is subject to
traffic or abuse. This may result in a shock or fire hazard.
4. Do not attempt to service this television set yourself as opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified service personnel.
5. Never push objects of any kind into this television set through cabinet slots as they may touch dangerous voltage
points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the television set.
6. If the television set has been dropped or the cabinet has been damaged, unplug this television set from the wall outlet
and refer servicing to qualified service personnel.
7. If liquid has been spilled into the television set, unplug this television set from the wall outlet and refer servicing to
qualified service personnel.
8. Do not subject your television set to impact of any kind. Be particularly careful not to damage the picture tube surface.
9. Unplug this television set from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a
damp cloth for cleaning.
10.1. Do not place this television set on an unstable cart, stand, or table. The television set may fall, causing serious injury
to a child or an adult, and serious damage to the appliance.Use only with a cart or stand recommended by the
manufacturer, or sold with the television set. Wall or shelf mounting should follow the manufacturer s instructions, and
should use a mounting kit approved by the manufacturer.
10.2. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces
may cause the appliance and cart combination to overturn.
CAUTION:
Read all of these instructions. Save these instructions for later use.Follow all Warnings and
Instructions marked on the audio equipment.
1. Read Instructions- All the safety and operating instructions should be read before the product is operated.
2. Retain Instructions- The safety and operating instructions should be retained for future reference.
3. Heed Warnings- All warnings on the product and in the operating instructions should be adhered to.
4. Follow Instructions- All operating and use instructions should be followed.
IMPORTANT SAFETY INSTRUCTIONS

4
PROTECTION AND LOCATION OF YOUR SET
11. Do not use this television set near water ... for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a
wet basement, or near a swimming pool, etc.
Never expose the set to rain or water.If the set has been exposed to rain or water, unplug the set from the wall
outlet and refer servicing to qualified service personnel.
12. Choose a place where light (artificial or sunlight) does not shine directly on the screen.
13. Avoid dusty places, since piling up of dust inside TV chassis may cause failure of the set when high humidity persists.
14. The set has slots, or openings in the cabinet for ventilation purposes, to provide reliable operation of the receiver, to
protect it from overheating. These openings must not be blocked or covered.
Never cover the slots or openings with cloth or other material.
Never block the bottom ventilation slots of the set by placing it on a bed, sofa, rug, etc.
Never place the set near or over a radiator or heat register.
Never place the set in enclosure, unless proper ventilation is provided.
PROTECTION AND LOCATION OF YOUR SET
15.1. If an outside antenna is connected to the television set, be sure the antenna system is grounded so as to provide some
protection against voltage surges and built up static charges, Section 810 of the National Electrical Code, NFPA No.
70-1975, provides information with respect to proper grounding of the mast and supporting structure, grounding of the
lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge unit, connection
to grounding electrode, and requirements for the grounding electrode.
15.2. Note to CATV system installer : (Only for the television set with CATV reception)
This reminder is provided to call the CATV system attention to Article 820-40 of the NEC that provides
guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding
system of the building, as close to the point of cable entry as practical.
16. An outside antenna system should not be located in the vicinity of overhead power lines or other electric lights or power
circuits, or where it can fall into such power lines or circuits.When installing an outside antenna system, extreme care
should be taken to keep from touching such power lines or circuits as contact with them might be fatal.
17. For added protection for this television set during a lightning storm, or when it is left unattended and unused for long
periods of time, unplug it from the wall outlet and disconnect the antenna. This will prevent damage due to lightning
and power-line surges.
ANTENNA
LEAD- IN WIRE
ANTENNA DISCHARGE
UNIT (NEC SECTION
810-20)
GROUNDING
CONDUCTORS
(NEC SECTION 810-21)
GROUND CLAMPS
POWER SERVICE GROUNDING
ELECTRODE SYSTEM
(NEC ART 250. PART H)
ELECTRIC SERVICE
EQUIPMENT
GROUND CLAMP
NEC-NATIONAL ELECTRICAL CODE
EXAMPLE OF ANTENNA GROUNDING AS PER
NATIONAL ELECTRICAL CODE
EXAMPLE OF ANTENNA GROUNDING AS PER NATIONAL ELECTRICAL CODE INSTRUCTIONS
a built-in
installer s

OPERATION OF YOUR SET
18.
This television set should be operated only from the type of power source indicated on the marking label.
If you are not
sure of the type of power supply at your home, consult your television dealer or local power company. For television
sets designed to operate from battery power, refer to the operating instructions.
19. If the television set does not operate normally by following the operating instructions, unplug this television set from the
wall outlet and refer servicing to qualified service personnel. Adjust only those controls that are covered in the operating
instructions as improper adjustment of other controls may result in damage and will often require extensive work by a
qualified technician to restore the television set to normal operation.
20. When going on a holiday : If your television set is to remain unused for a period of time, for instance, when you go on
a holiday, turn the television set and unplug the television set from the wall outlet.
IF THE SET DOES NOT OPERATE PROPERLY
21. If you are unable to restore normal operation by following the detailed procedure in your operating instructions,
do not attempt any further adjustment. Unplug the set and call your dealer or service technician.
22. Whenever the television set is damaged or fails, or a distinct change in performance indicates a need for
service, unplug the set and have it checked by a professional service technician.
23. It is normal for some TV sets to make occasional snapping or popping sounds, particularly when being
turned on or off.If the snapping or popping is continuous or frequent, unplug the set and consult your
dealer or service technician.
FOR SERVICE AND MODIFICATION
24. Do not use attachments not recommended by the television set manufacturer as they may cause hazards.
25.When replacement parts are required, be sure the service technician has used replacement parts specified
by the manufacturer that have the same characteristics as the original part. Unauthorized substitutions
may result in fire, electric shock, or other hazards.
26. Upon completion of any service or repairs to the television set, ask the service technician to perform
routine safety checks to determine that the television is in safe operating condition.
5
off

2、Specification
Model
Item
Master Data
-Version V2.0
-Customer ID
-Destination SA
-Brand
-BOM NO. 03-BE12SQ-SM0
-Chassis M60
-Tuning [Channels Amt.]
-Tuning [Indication]
-Frequency Bands Full-Cable
-IF Frequency 45.75MHz
-TV Systems (Color+ Sound) NTSC M
-AV Systems NTSC M / PAL M N
Picture-Processing
-SCAN Standard
-Wide Screen Switching
-Comb filter
-Picture Enhancement X
LTI / CTI
Black Stretch included
Dynamic Skin included
Others blue strech
-Picture Control [General]
Brightness X
Sharpness X
Contrast X
Tint X
Color X
-Picture Control [Special]
Smart Pictures * modes 4:3,16:9
VM
Color Temperature X
Others
-Picture Noise Reduction X
Picture – Display
-CRT Type
Normal Flat
Pure Flat X (Slim)
Super Flat
-Deflection system
1Fh X
2Fh
-Tube Technology
Iron X
AK
Black Matrix X
Others
-CRT Deflection ( * Deg.) 090 degr
-CRT Magnetic Field
-Screen Type 4:3
-Screen Size / Vis. Size 29"
Sound
-Audio Power Consumption 2x6w
-Surround Sound
-Nicam
-America Stereo (MTS,BTSC,MPS) X
-America SAP X
-Korea Stereo
-Thai Bilingual
-Super Woofer DVB
-AVL X
-Sound Control [General]
Volume X
Mute X
-Sound Control [Special]
Treble X(substitute for Equalizer)
Bass X(substitute for Equalizer)
29E12
Chassis:M60 Version:3.0 Page4
6

Model
Item 29E12
Balance X
Equalizer X(substitute for T&B)
Smart Sound * modes X
Others Loudness
-Speakers Quantity 2
User Interface
-Menu Language English, Spanish, French,Portuguese
-Features [General]
AT
Biological Lock
Calendar X
Clock X
Channel Swap X
Channel Adjustment
Channel Naming X
Child Lock X
Preset Lock X
Max volume X
Panel Lock X
AV Lock X
Favorite Channel X
Game X
Hotel Mode X
High Sensitive
Notebook X
On/Off Timer X
Preset X
Recall X
Rotation
Auto Sleep X
Programe prearrange X
Parent Guide X(inlucding child lock&V-chip)
Channel Skip X
Others
-Features [Special]
V-chip / CCD X
Teletext *Pages
FM Radio
Others
Tuning Features
-Auto Channel Program
-Auto/Manual Tuning X
-Auto/Manual Store X
-Fine Tuning X
-Factory Mode X
-Service Mode
Cabinet
-Cabinet Name 29E12
-Front Cabinet Color 前壳颜色:银色-A6819
-Middle Cabinet Color 无
-Rear Cabinet Color 默认
-Local Controls Front
Mains Switch
CH+ CH- VOL+ VOL-
TV/AV
Menu
Auto Search
-Local Controls Top
CH+ CH- VOL+ VOL-
TV/AV
Menu
Auto Search
-Indicator
RC Received LED
Standby LED
Remote Controller
-Type F
-Batteries
Chassis:M60 Version:3.0 Page5
7

Model
Item 29E12
Connectors Rear
-SCART Full w/o Y/C
-SCART Full with Y/C
-SCART Single (CVBS)
-Component In (YPbPr) Cinch for 50Hz X
-In Y/C+Cinch(CVBS+ Stereo)
-In Y/C+Cinch (CVBS+ Mono)
-In Cinch(CVBS+ Stereo) X
-In Cinch (CVBS+ Mono)
-Out Cinch(CVBS+ Stereo) X
-Out Cinch(CVBS+ Mono)
-Super Woofer
-Digital Audio Out
-Loudspeakers
-Control Busses
-Feature Slot
-ITV Smart Port
- Antenna in
75 Ohms (F Type) X
Connectors Front/Side SIDE
-In Y/C+Cinch(CVBS+ Stereo) X
-In Y/C+Cinch (CVBS+ Mono)
-In Cinch(CVBS+ Stereo)
-In Cinch (CVBS+ Mono)
-Out Headphone
Mini-Jack 3.5mm
Final Equipment 全套美工资料(采用EM市场新VI包装)
-Packing –Methods
2 Color Printing
Carton Color
-Documents and Manuals
Instruction Book
Screen Sticker
Plastic Bag
Warranty Card
Guarantee Doc.
Warning Label
Approbation Label
Others
-Languages DFU English
-Indication on BACKOVER
Made-in in family sheet
FCC/Elect Shock Caution Label
CE/Elect Shock Caution Label
Warning Label
Others
Approbation CB
Miscellaneous
-Mains Voltage 100 V-240V
-Mains Frequency 50/60Hz
-Type Mains Cord SA
-Power Consumption TV in ON
-Power Consumption TV in Standby 10W
Chassis:M60 Version:3.0 Page6
8

3、Alignment Procedure
Table of Content
1.GENERAL...................................................................................................................................... 10
1.1 COMMON INFORMATION................................................................................................................... 10
1.2 HOW TO ENTER&EXIT FACTORYMODE(SERVICE MENU, SERVICEMODE).............................. 10
1.3AFEW SPECIAL MODES..................................................................................................................... 10
2. ALIGNMENT PROCEDURES:........................................................................................................ 11
2.1 B+ VOLTAGEADJUSTMENT................................................................................................................ 11
2.2 CRYSTAL OSCILLATOR FREQUENCYADJUSTMENT.......................................................................
2.3 RFAGCADJUSTMENT........................................................................................................................
2.4 SCREEN & FOCUS VOLTAGEADJUSTMENT....................................................................................
2.5 WHITE BALANCEADJUSTMENT (NORMAL) .....................................................................................
2.6ADJUSTMENT OF SUB-BRIGHTNESS................................................................................................
2.7 PICTURE GEOMETRICADJUSTMENT............................................................................................... 12
2.8 EHT/HEW RATIO TEST:(TEST WITH PC PROGRAM).............................................................. 13
2.9 X RAYS OVER VOLTAGE PROTECTING CIRCUIT TEST................................................................. 13
2.10 PS LINE POLARITIES TEST............................................................................................................ 14
2.11 PS POWER TEST............................................................................................................................. 14
2.12 HIGH VOLTAGEAND IB VALUE LIMITTEST( RANDOM TEST ).................................................... 14
2.13 HEATER VOLTAGE TEST ( RANDOM TEST )................................................................................... 15
2.14 MAIN FUNCTION TEST(EG, NICAM, BTSC, TELTEXTAND ETC.)................................................. 15
3. EEPROM DATAAND ADDRESS ................................................................................................. 15
4. WHITE BALANCEADDRESS ................................................................................................... 15
5. CDRH DOCUMENT ( IFAVAILABLE) ........................................................................................ 20
6. REMARK........................................................................................................ .......................20
11
11
11
11
12
9

1. GENERAL
1.1 Common Information
Use isolating transformerwith low internal resistance.
Mains voltage is 100-240 VAC, unless otherwise stated.
All voltages and waveformsmentioned are with respect to Ground. Do not use heat-sink as Ground
1.2 How to enter&exit factory Mode (Service menu, service mode)
1.2.1 Certain alignment procedures need to enter Factory Mode (Service Menu). There are two ways to
access factory mode:
One is :A. Press and hold the VOLUME DOWN key tightly on the unit until minimum level
B. Don’t release the VOLUME DOWN key on the unit
C. Then press the CAPS key in 3 times on the RC
The other is:
Press “Service “ Key on the factoryRC. (Please noted the “D-mode” key is the invalid
shortcut key if “bit-0” of“mode 1” is at “1”.)
1.2.2 Exit from Service Mode by “TV/AV” or “SERVICE” Key on the RC
1.2.3 All system data in Factory Mode of “Key 8 & Key 9” are not adjustable when servicing, otherwise,
the set will work abnormally.
1.2.4 It is suggested to disable the Service key before the set leavethe factory.
Navigation:
-Press “Pro+” “Pro -” key to select option;
-Press “Vol+ ” “Vol-” key to adjust or select option.
-Press “0-9” “Notebook” “Favorite” “Display” “Sleep” “Game” on the RC as the
shortcut key to access factory menu.;All change in factory data will be saved in
EEPROM automatically
-Press “BUS OFF” key on factory RC to cut off the I2C control from the CPU to other
ICs. This is only valid during automatic adjustment of white balance.
1.3 Afew special modes
1.3.1 Aging Mode is used before set alignment. It would operate in factory mode;
1.3.2 Vertical Stop mode is used to confirm the screen voltage. Press “Mute” key in factory mode and
repress “ mute” key to exit.
1.3.3 White balance alignment mode
1.3.4 Factory-out Initialization In factory mode,
Press RECALL button to initialize the FACTORY-OUTstatus.
Press VOLUME UP button to start InitializationVolume: 30, PG password:0000, Favorite channel:
ch1/ch2/ch3, channel lock: disable, Picture mode: Dynamic, Color temp: normal,
calendar:01-08-2004
1.3.5 EEPROM INITIALZATION: In D-MODE, press “-/--” to initialize EEPROM.
NOTICE: Before to be released, any M68 chassis must be initialized to the FACTORY-OUT status.
10

Don’t try to initialize EEPROM,unless software can’t work normally.
2. Alignment procedures:
2.1 B+ voltage adjustment
2.1.1 Needn’t adjust B+ voltage on the line.
All relevant connectors andmodules must be connected and inserted.
Mains voltage is at 230VAC, 50Hz or 110VAC, 60Hz.
Apply Color Bar Testing Pattern to RF in put.
Adjust VR800 in STANDARD mode
Note: ☆We recommend this B+ voltage, but each factory PE must adjust many parameters to match the
new tube, and the exact B+ voltage must according to that.
2.1.1 Needn’t adjust B+ voltage on the line.
2.2 Crystal oscillator frequency adjustment
2.2.1 Crystal oscillator frequency adjustment with NICAM
a.Apply PAL BG NICAM signal with good reception quality.
b. Enter factory mode, press“game” key , then press“V+” key to adjust “DCXOAuto”, until it
displays “OKEY”.
2.2.2 Crystal oscillator frequency adjustment without NICAM
a. Input PAL color bar signal.
b.Auto adjustment: Enter factory mode,press “game” key , then press “V+” key to adjust
“DCXOAuto”, until it displays“OKEY”.
Manual adjustment :On factory mode, press “0” to adjust “DCXO CAP” until DISC steady at 128.
2.3 RF AGC adjustment
2.3.1 Input 58dB grey scalesignal.
2.3.2 Press key “4” to enter RFAGC adjustment.
2.3.3 Press “OK”or “EXIT” key to auto adjust RF AGC, also can adjust “RF AGC” by “”volume -/+” key
until the letter change from “INACTIVE” to ”ACTIVE”.
* The others use default value.
2.4 Screen & Focus voltage adjustment
2.4.1 Screen voltage adjustment
a. Press “MUTE” key on the remote control and the screen will become a horizontal line,
here vertical stop vibration. Then adjust the “screen” VR on the flyback until the horizontal
line can just be seen (minimum visible intensity).
2.4.2 Focus voltage adjustment
a. Input cross hatch pattern signal.
b. Adjust the “focus” VR on the flyback until the screen becomes clear.
2.5 Whitebalanceadjustment(NORMAL)
CRT type
(Part Number) B+ Voltage
A68ELW021×001 140±0.3V
A68ELW021×003 140±0.3V
11

2.5.1 Choose Black and White pattern signal (PAL).
2.5.2 On factory mode, press “1” key enter white balance adjustment.
2.5.3 Measure the dark side of the picture with a color analyzer adjust RED and GRN until the data on the
analyzer match standard data.(x=274+8, y=280+8).
2.5.4 Measure the bright side of the picture. Then adjust WPR, WPG and WPB until the data on the
analyzer match standard data.(x=274+8, y=280+8).
2.5.5 Repeat step 1 and 2 until you get right color on both dark and brightside of the screen.
Remark :
1. When adjusting, RED、GRN are used to adjust black balance and WPR、
WPB、WPG are used to adjust white balance .
2. On product line, the itemwhich can be auto adjusted by auto test
equipment , its data according to auto adjust value.
3. White balance address please meet the fourth part at page 10.
2.6 Adjustment of Sub-brightness
2.6.1 Input grey scale + color bar signal.
2.6.2 Press key “6” to enter sub-brightness adjustment.
2.6.3 At standard state, adjust “BRTC” , until the secondarygrey just be seen.
* Do not change value “BRTS”.
2.7 Picturegeometricadjustment
2.7.1 Vertical geometric adjustment
a. Input a PALcross hatch pattern signal .
b. Press key “2” to enter Vertical geometric adjustment .
c. Use remote control to adjust one by one , watch the figure, until the center or the corner
grid has a same size .
d. When adjust vertical position, make the center of verticalintermediately.
e. In “5VSL”, the second halfmay blanking , adjust the first half at display range.
Remark:
1 5VSC , 31 is fixed, don’tadjust .
2 5VPOS for vertical position.
3 5VAM for vertical amplitude.
4 5VSLforverticalslope.
5 5VLfor vertical linearity.
6 5SCLfor vertical S-correction.
7 5WBR for end of blanking time on 4:3 mode (16:9 tube).
8 5WBF for start of blanking time on 4:3 mode (16:9 tube).
9 5BSWBR for right sideblack width of blue screen .
10 5BSWBF for left sideblack width of blue screen.
* 5WBF/5WBR only use on matching 16:9 tube, at 4:3 picture mode, adjust blanking
time of R and F. First press “ZOOM” key switch to 4:3 mode, then adjust 5WBF and 5WBR
respective to make the overscan meet the requirements.
*Adjustment is disabled when match 4:3 tube.
* 5BSWBR and 5BSWBF needn’t adjustment.
*Apply NTSC signal to adjust these registers for NTSC geometric
12

2.7.2 Horizontal geometry adjustment
a. Input a PAL cross hatch pattern with black and whitebackground signal.
b. Press key “3” enter Horizontal geometric adjustment.
c. Use remote control to adjust one by one , watch the figure, until the center and the vertical
line at left and right side of thepicture become straight.
Remark:
1. Adjust 5HSH for horizontal position, data should make H center mediacy .
2. 5PAR for parallelogram adjustment.
3. 5BOW for bow adjustment.
4. Adjust 5EWW for horizontal width.
5. 5EWP for pincushion correction.
6. 5UCR for upper cornercorrection.
7. 5LCR for low corner correction.
8. 5EWT for trapezium correction.
* Apply NTSC signal to adjust these registers for NTSC geometric
2.8 EHT/HEW ratio test:(test with PC program)
Equipment requirements :High Voltage Meter (Range: 0 - 40kV)、High voltage test
stick (1000:1)、Adjustable DC power supply、Dummy deflexion coil(as same inductance as
CRT which use to product).
Test method :
a. Mount the EHT cap onto the fixture and connect the EHT meter. Plug in
the dummy deflection coil. Connect the DC meter across C417.
b. Switch on the chassis and measure the ratio of EHT/HEW at Ib= 0
( brightness、contrast are minimum).
Here, the HEW is the DC voltage across C417.
EHT voltage V, HEW voltage V1.
c. Apply PC program, V/V1 need satisfy request below :
2.9 X rays over voltage protecting circuit test
Test method :
When TV ON with color bar signal, add more than 27V DV to C417, machine
could enter into protection mode, otherwise please inspect X rays over voltage
protecting circuit .
EHT/HEW (V/V1)
29276SQ 44-29RFLS-OR3A
A68QDL082X012(B)
13

2.10 PSlinepolaritiestest
This test only the machines which will sell to NAFTAshould be done.
Test method :
Connect as drawing below :
DX 2.2k
Power Supply jack M
TO F801
Plug the card power connector plugs to Power Supply jack M, and use multimeter pen touch
F801 random pin, then LED DXshould luminescence and clew with sound, otherwise it is
unqualified.
2.10 PS power test
Equipment requirements : Wattmeter
Test method :
a. Input more than 60dB color bar signal, audio 1K Hz, 100% modulation.
b. Brightness and contrast are maximum, adjust the volume to make the audio output power
at 0.5W.
c. Connect the wattmeter to test power consumption of Power Supply.
d. Switch the set to standbymode, and then measure the power consumption of Power
Supply again.
It should satisfy request below :
2.12 High voltage and Ib value limit test( random test )
Equipment requirements :Multimeter, High Voltage stick
Beam Current Meter
Input signal type :A 60dB white pattern signal.
Test method :
a. Connect the EHT-meter across the anode and aquadag of the CRT.
b. Connect a beam current meterbetween the anode of picture tube and EHT-cable of FBT.
Type Power Standby power
25” ?W 10W
29” ?W 10W
34” ?W 10W
DC Power Supply
9V
- +
Sound clew equipment
14

c. Measure the EHT-voltage at zero beam current (Ibeam = 0µA).
d. Subsequently, measure the EHT-voltage at respective Ibeam(s) .
It should satisfy request below :
2.13 Heater voltage test ( random test )
Equipment requirements : True RMS Voltmeter
Input signal type :Philips test card ( from 1 mV rms(60dBuV)to 50 mV rms )
Test method :
a. Connect the true RMS voltmeter between the heater and grand.
b. Adjust the brightness and contrast to maximum .
c. Then, test the heater voltage . It may be Vrms
2.14 Main function test (eg, NICAM, BTSC, TELTEXT and etc.)
NICAM test standard please reference
BTSC test standard please reference
TELTEXT test standard please reference Q/WP1259-2003.
CCD、V-CHIP test standard please reference EIA-744-A
3. EEPROM Data andAddress
Items marked with *are adjustable, the othersare not.
KEY1 KEY2
Model
No. RED*GRN*WPR*WPB*WPG*5VPOS*5VAM*5VSL*5VL*5VSC
29276SQ 32 26 35 23 33 32 21 33 30 31
S29E12K 32 32 32 32 32 32 21 33 30 31
S29M62K 30 28 37 37 30 32 19 28 30 31
KEY2
Model
No. 5SCL*5WBF*5WBR*5BSWBF*5BSWBR*6VPOS*6VAM*6VSL*6VL*6VSC
29276SQ 31 11 15 9 8 37 25 32 32 31
S29E12K 31 11 15 9 8 37 25 32 32 31
S29M62K 44 11 15 8 5 35 25 32 32 31
Beam current EHT-voltage (KV)
Ib = 50µA
Ib=50µA&1200µA
15

KEY2 KEY3
Model
No. 6SCL*6WBF*6WBR*6BSWBF*6BSWBR*5HSH*5PAR*5BOW*5EWW*5EWP*
29276SQ 32 12 9 15 15 30 22 39 24 37
S29E12K 32 12 9 15 15 30 22 39 24 37
S29M62K 32 12 9 15 15 17 47 28 36 28
16

KEY3
Model
No. 5UCR*5LCR*5EWT*6HSH*6PAR*6BOW*6EWW*6WEP*6UCR*6LCR*6EWT*
29276SQ 40 44 18 40 26 39 26 41 42 44 11
S29E12K 40 44 18 40 26 39 26 41 42 44 11
S29M62K 40 48 24 40 26 39 26 41 42 44 11
KEY4
Model
No. RF
AGC*CPEK
PAL CFPEK
PAL CFPEK
NTS CFPEK
YUV IFPL BBTC PG
R/G/B VG2BRI*HDOL
29276SQ 20 32 3.5M 3.1M 4.0M 32 32 64 20 4
S29E12K 28 32 3.5M 3.1M 4.0M 32 32 64 20 4
S29M62K 22 32 3.5M 3.1M 4.0M 32 32 64 20 0
KEY5
Model
No. CNTX CNTN BRTX BRTN COLX COLN TNTX TNTN
29276SQ 53 2 11 5 63 0 20 12
S29E12K 63 2 11 7 63 0 20 12
S29M62K 54 2 50 5 58 4 20 12
KEY6
Model
No. CNTC BRTC*COLC TNTC COLP COLS BRTS
29276SQ 25 32 28 30 0 28 0
S29E12K 30 25 28 30 0 28 0
S29M62K 30 25 28 30 0 28 0
17

KEY 7
Model No. SHPTV4 SHPX SHPN OSD
BRI CC
BRI 5CCD
H
5C
CD
V 5OSDH 5OSDV 5MENUV
MENUH
29276SQ 31 31 31 15 8 8 35 15 42 18 7
S29E12K 31 31 31 15 8 8 35 15 42 18 7
S29M62K 31 31 31 15 8 8 35 15 42 18 7
KEY 7
Model
No. 6CCDH 6CCDV 6OSDH 6OSDV 6MENUV MENUH
29276SQ - - - - - -
S29E12K 8 35 15 42 18 7
S29M62K 8 35 15 42 18 7
KEY8
Model
No. OPT1*OPT2*OPT3*OPT4*OPT5*OPT6*OPT7*OPT8*OPT9*OPT10*
29276SQ 0A 80 33 0 27 0B 58 0 04 00
S29E12K 0A A0 13 0 27 04 51 0 04 00
S29M62K 0A A0 13 0 27 04 58 0 04 00
KEY9
Model No. MODE1*MODE2*MODE3*MODE4*MODE5*MODE6*MODE7*MODE8*MODE9*MODE10*
29276SQ 29 97 50 AD 1F 8E 10 22 C2 10
S29E12K 3B C8 04 AC 4F 8E F0 2B C9 0
S29M62K 36 C8 04 AC 4F 88 30 2B C9 0
18

KEY DISPLAY KEY0
VOL VOL VOL VOL YDFE DEC MONO NIC SAP ADC DCXO NICLP
PSCALE
Model No.
1 25 50 100 PAL LVL LVL LVL LVL LVL CAPV*INV*
29276SQ 27 121 135 148 15 0 0 0 0 0 54 Not
inverted
0.375
S29E12K 27 122 143 163 15 0 0 0 0 0 54 Not
inverted 0.375
S29M62K 27 122 135 159 15 0 0 0 0 0 54
KEY0 KEY NOTEBOOK
BASS TREBLE 300Hz
Model
No. PLIM PCENTER*LOUNDESS M S T M S T M S T
29276SQ 96 212 6 86 30 40 85 30 70 11 4 5
S29E12K 96 12 6 85 30 40 85 30 70 11 4 5
S29M62K
KEY NOTEBOOK KEY FAVORITE
500Hz 1K Hz 5K Hz 8K Hz Warm*Cool*
Model
No. M S T M S T M S T M S T R G B R G B
29276SQ 9 7 6 6 6 7 9 7 9 11 4 11 4 0 6 6 0 4
S29E12K 9 7 6 6 6 7 9 7 9 11 4 11 4 0 6 6 0 4
S29M62K 9 7 6 6 6 7 9 7 9 11 4 11 4 0 6 6 0 4
KEY SLEEP
SET DATA DATA DATA SPE SPE SENSI SENSI
Model
No. SET
P1*P2*VL*VH*UF*POSI DATA ON OFF
29276SQ 128M 362M 01H 02H 08H 06H 05H 00H 00H
S29E12K 128M 362M 01H 02H 08H 06H 05H 00H 00H
S29M62K 128M 362M 01H 02H 08H 06H 05H 00H 00H
19

4. White balance address
R G B R AMP G AMP B AMP R CUT G CUT B CUT Remark
Offset DATA 142 143 150 146 161 ***** Factual setup
IC write(LsB)
SubAdd 32 33 34 23 24 *****
Start Bit 6 6 6 6 6 *****
St0p Bit 0 0 0 0 0 *****
E2PROM
SubAdd(LsB) 122 123 124 119 120 ***** TV standard color TEM
Reference B BJ SanAi(SWB-301)
SlaveAddress(write)
16 Bit EEPROM PageAddr
IC 138 E2PROM 160
5. CDRH Document ( If available)
6. REMARK
The items, marked in Grey, which are invalidfor this chassis.
7 Important notice
Below IC must be burned software:
(1) IC001 (13-00M24C-XXP): must be burned EDID before surface mount;
(2) IC200 (13-P120XXXX):must be burned software online. And the burning port is P003
20
Table of contents
Other Sampo TV manuals