Satel SP-4006 Series User manual

®
OPTICAL-ACOUSTIC
OUTDOOR SIREN
SP-4006
sp4006_en_06/09
The SP-4006 optic l- coustic outdoor siren is designed for intruder l rm systems. It comes
in two versions: SP-4006 nd SP-4006 BL, which differ by the color of optic l sign ling (red
in the SP-4006, blue in the SP-4006 BL). As the light source in the siren, two sets of LEDs
re used. The sound sign l is gener ted by me ns of piezoelectric tr nsducer. Design of
the siren housing, s well s the inner cover m de from g lv nized met l sheet, ensure
high degree of t mper protection ( g inst opening nd/or pull-off from the mounting surf ce).
Electronic circuit is m de in SMD technology nd impregn ted g inst dverse effect of
we ther conditions, thus ensuring high reli bility of the equipment. The outer housing of the
siren is m de of PC LEXAN high-imp ct polyc rbon te, so it fe tures very high mech nic l
strength nd gu r ntees esthetic look of the equipment even fter m ny ye rs of service.
1. Installation
Fig. 1. Housing of the SP-4006 outdoor siren.
Expl n tions for Figure 1:
1 - cover ret ining screws.
2 - c ble entry hole.
3 - t mper element of the housing (should be screwed to the mounting surf ce; do not
pply excessive force, so s not to bre k the n rrowings).
4 - mounting holes.
The SP-4006 outdoor siren should be mounted on fl t surf ce, t pl ce which is s h rd
to ccess s possible, so s to minimize the risk of t mpering. The device must be tt ched
to the surf ce by me ns of screws nd exp nsion plugs. In order to t ke off the cover,

2 SP-4006 SATEL
remove the two locking screws nd lift it by n ngle of pprox. 60°. Be p rticul rly c reful
when dismounting nd remounting the inner sheet met l cover.
Note: Make sure there is a suitable distance (minimum 2.5 cm) between the upper edge of
the siren housing and the ceiling or another element which restricts the mounting
position from the above. Otherwise, replacement of the cover may be impossible.
After inst ll tion of the outdoor siren mounting holes s well s the c ble inlet should be
se led with silicone compound.
2. Description of siren operation
The SP-4006 outdoor siren c n interf ce with ny l rm sign l source. The sign ling is
triggered by volt ge ch nge t the control input. The STA input controls coustic sign ling,
while the STO input - optic l sign ling. How the sign ling is to be triggered is set by me ns of
the PLA nd J7 jumpers nd the PLO nd J6 jumpers.
The siren h s been designed so th t t the moment of power-up it is in ctive, irrespective on
how the STA, STO inputs re set. Sign ling c n only be triggered fter 20 seconds
in the st ble in ctive st te (const nt presence of supply volt ge from the control p nel nd
input sign ls ccording to the jumper setting). On e ch power-up / power-off, the time is
counted from the beginning. This function m kes it possible to void n ccident l triggering
of the siren during inst ll tion of the system.
The test mode en bles the sign ling to be triggered without the necess ry 20-second w it.
For this purpose, remove the O+A jumper before power-up, turn the power supply on nd
repl ce the jumper within 5 seconds.
The TMP nd R termin ls re used to connect the device to the t mper circuit of the security
system, while the SENS nd TMP termin ls re provided for connecting the inner t mper
cont ct of the housing (see Fig. 2 nd 3).
The t mper circuit of the outdoor siren will be open on removing the outer housing or
det ching the siren from the w ll. For the t mper cont ct to function correctly during pull-off,
the t mper element (see Fig. 1) must be screwed down to the mounting surf ce.
The siren is suit ble for oper tion with built-in 6 V b ttery, but it c n lso work without it.
A T3,15 A fuse is included in the b ttery circuit.
Notes:
• he battery to be connected to the siren must be fully charged.
• he current consumed by the siren to charge the battery depends on the battery degree
of discharge.
• he battery charging system, as used in the siren, is intended for recharging a partially
discharged battery, not for charging a fully discharged one.
Extern l power supply of the siren is to be connected to the +12V nd GND termin ls.
Volt ge loss t these termin ls (with the siren b ttery connected) will gener te the t mper
l rm, dur tion of which depends on how the TM0, TM1 jumpers re set. The type of
sign ling is to be set by using the O+A jumper. Supply volt ge restor tion will stop
the t mper sign ling. H ving inst lled the siren, check this function for oper tion l c p bility
by disconnecting nd reconnecting the supply volt ge.
Note: he M0 and M1 jumpers are used for setting the maximum active time of acoustic
signaling. After expiry of this time, the siren will go silent, irrespective of the value
programmed in the control panel. he signaling can only be triggered again after the
signal controlling the S A input is disabled.

SATEL SP-4006 3
The SP-4006 BL siren h s the two indic tor LEDs situ ted on the opposite ends of housing
sides, which re blinking ltern tely 1 s / 1 s when supply volt ge is v il ble t the +12V
input. This function c nnot be dis bled.
The SP-4006 BL siren h s n indic tor LED situ ted in the middle of the lower edge of
enclosure. The LED is blinking when supply volt ge is present t the +12V input. Remov l of
the jumper design ted s LED will dis ble the LED function.
3. Connection
There re two types of l rm outputs which re used in l rm control systems: common
ground outputs nd common supply outputs. The siren c n be ctiv ted by ny type of
output, provided th t suit ble connections re m de.
Note: he converter supplying the acoustic siren system generates a very high voltage
which can cause electric shock when touched. Hence, all connections may only be
made when the battery is disconnected and the +12 V wire is to be connected last.
INTEGRA 32
STO
TMP SENS. TMPTMP
STA
SP-4006
GND
+12V
R
Fig. 2. W y of connecting the SP-4006 siren to the l rm control p nel without resistor in
the siren t mper circuit. The OUT2 high-current output is progr mmed s the supply one.
The OUT3 nd OUT4 low-current outputs control the sign ling (OUT3 will trigger the coustic
sign ling, nd OUT4 – optic l). The Z1 one is programmed as tamper, NC type.

4 SP-4006 SATEL
INTEGRA 32
STO
TMP SENS. TMPTMP
STA
SP-4006
GND
+12V
R
R
Fig. 3. W y of connecting the SP-4006 siren to the l rm control p nel with resistor in the
siren t mper circuit. The OUT2 high-current output is progr mmed s the supply one. The
OUT3 nd OUT4 low-current outputs control the sign ling (OUT3 will trigger the coustic
sign ling, nd OUT4 – optic l). The Z1 one is programmed as tamper, EOL type.
4. Jumper settings
Inst lled on the electronics bo rd re 10 p irs of pins for configur tion of the siren oper tion.
The settings re to be selected by shorting or opening the suit ble p ir of pins. Description of
the possible settings is shown in the t ble below.
The SP-4006 siren h s n ddition l LED jumper.
Note: For effective signaling, the triggering inputs must be properly polarized. Settings of
the PLA and PLO jumpers is closely connected with those of the J6 and J7 jumpers
(if used).

SATEL SP-4006 5
SELECTION OF ACOUSTIC SIGNAL TYPE
ML0
ML1
Two-tone sign l, step
modul ted
Steplessly modul ted
sign l
Steplessly modul ted
sign l
Steplessly modul ted
sign l
LIMITATION OF ACOUSTIC ALARM DURATION TO:
TM0
TM1
Approx. 1 minute
Approx. 5 minutes
Approx. 10 minutes
Approx. 15 minutes
SIGNALING MODE AFTER POWER SUPPLY LOSS
O+A
Acoustic nd visu l l rm
Acoustic l rm only
STA INPUT POLARIZATION ( coustic)
PLA
and
J7
Acoustic l rm will be triggered when
+12 V volt ge is pplied to STA termin l
PLA
and
J7
Acoustic l rm will be triggered when 0 V
volt ge is pplied to STA termin l
STO INPUT POLARITZATION (visu l)
PLO
and
J6
Visu l l rm will be triggered when +12 V
volt ge is pplied to STO termin l
PLO
and
J6
Visu l l rm will be triggered when 0 V
volt ge is pplied to STO termin l
Design tion
of pins st tus:
– pins open
– pins shorted

6 SP-4006 SATEL
5. Specification
Power supply ..................................................................................................... 12 V DC ±20%
Current consumption, st nd-by ........................................................................................40 mA
Current consumption, m ximum:
optic l sign ling ........................................................................................ 250 mA
coustic sign ling ...................................................................................... 190 mA
optic l nd coustic sign ling ................................................................... 400 mA
Built-in b ttery ............................................................................................................ 6V/1.3 Ah
Built-in b ttery protection ...................................................................................... fuse T 3.15 A
Sound pressure ...................................................................................................... up to 120 dB
Working temper ture r nge ................................................................................... -35…+55 °C
Housing dimensions ........................................................................................ 148x254x64 mm
Weight ............................................................................................................................ 1.14 kg
L test EC decl r tion of conformity nd product pprov l certific tes c n be
downlo ded from our web site www.satel.pl


SATEL sp. z o.o.
ul. Schubert 79
80-172 Gd ńsk
POLAND
tel. + 48 58 320 94 00
info@s tel.pl
www.s tel.pl