Sensica Sensilight PRO User manual

1
English
Table of Contents
RPL™ (Reactive Pulsed Light) Technology-How does it work? 2
Intended Use 3
Who should NOT use the device? 4
CONTRAINDICATIONS 4
WARNINGS 5
CAUTIONS 6
Possible Adverse Eects 7
Device Description 8
User interface description 9
User Instructions 12
Preliminary Test 12
Getting Started 13
Step 1: Prepare your skin 13
Step 2: Device operation 13
Cleaning & Storage 19
Troubleshooting 19
Customer Service 20
Device specification parameters 21
Labeling 22

2
English
RPL™ (Reactive
Pulsed Light)
Technology - How
does it work?
RPL™ (Reactive Pulsed Light)
is an advanced technology
which uses clinically proven
IPL (Intense Pulsed Light)
technology in conjunction with
a skin tone and skin contact
sensor. The light emitted from
the device penetrates the
skin and is then absorbed by
the melanin pigment in the
hair shaft. The heat produced
by this light goes into the
follicle and generates a local
thermal eect, also known as
selective photothermolysis.
The thermal eect disables
the hair follicle which causes
a reduction in hair growth
while leaving the surrounding
skin unaected and cool.
Long-term hair reduction–
Hair growth cycle
Two factors play an
important role in optimal
long-term hair reduction:
• Hair growth cycle. Hair
growth involves three
phases: Anagen, Catagen,
and Telogen. Anagen is the
growth phase, while Catagen
and Telogen are the resting
phases. Permanent hair
reduction can only occur
in the Anagen phase, the
phase of growth. Since hair
growth is not synchronized, it
is recommended to complete
the full treatment protocol
to ensure every hair will
be exposed to treatment
during its Anagen phase.
• Skin tones (according to the
Fitzpatrick scale). Darker
skin contains more melanin,
which competes with the
targeted hair for energy
absorption. When more
energy is absorbed into
the skin, there is a greater
risk of adverse eects.
Phase 1 - Anagen
(growth phase)
Phase 2 - Catagen
(regression phase)
Phase 3 - Telogen
(shedding phase)

3
English
Please make sure to
carefully read this
user guide before
you start using the
device. The user guide
can also be found at
www.sensica.com
Intended Use
This is a home-use device
intended for the removal
of unwanted hair on the
entire body (e.g., legs, arms,
underarms, bikini line, back,
shoulders, chest and stomach)
and on permitted facial
areas (i.e., above upper lip,
cheek, jaw, chin and neck).
It is considered a medical
device without medical
use and does not have
clinical benefit.
Note: This device is especially
designed for your own personal
treatment and is intended for a
single user and home use only.
The device is intended for
use on skin tone types I to V
according to the Fitzpatrick
skin chart below (coloured
chart available on the
cover). Do not use on dark
skin such as type VI. The use
of IPL devices on naturally
dark skin is forbidden.
Skin
Tones
Hair
Colour
This device works best on
dark hair or hair that contains
more melanin. Brown and
light brown hair will respond,
but typically will require more
treatment sessions. Red hair
may show some response
while white, grey or blond hair
will show a limited response.
Nevertheless, some users have
noted hair reduction after
multiple treatment sessions.
Note: Hair removal by lasers or
Intense Pulsed Light can cause
increased hair growth in some
individuals. Based upon current
data, the highest risk groups
for this response are females of
Mediterranean, Middle Eastern,
and South Asian heritage,
treated on the face and neck.

4
English
Who should NOT
use the device?
Carefully read the information
below before you begin a
treatment with the device. If
you still have any doubts or
are unsure that the device
is safe for your use, please
consult with your physician.
CONTRAINDICATIONS
Do NOT use the device if you:
• Have an active implant
such as a pacemaker,
insulin pump or similar
devices, since it may
cause interference.
• Are pregnant, have a chance
of being pregnant or are
nursing since the device was
not tested on pregnant or
nursing women and may
stimulate pigmentation.
• Have skin cancer, areas
at risk of malignancy,
or if you have received
chemotherapy/radiation
therapy within the past 3
months since the safety
of such usage has not
been established and the
immune system can be
compromised, which can
lead to serious injury.
• Suer from epilepsy, as
using the device could
trigger a seizure.
• Have damaged or broken
skin, or a history of Herpes
or Psoriasis outbreak in
the treatment area since
such usage can result in
serious side eects.
• Suer from keloid scar
formation (growth of extra
scar tissue where the skin
has healed after an injury)
in the treatment area since
such usage has not been
established and may result
in serious skin complications.
• Have been taking
Tetracycline antibiotics or
medication with the following
active ingredients within
the last two weeks: Retinoid
acid, Retina-A, Vitamin
A (such as Accutane), as
they are considered to be
photo-sensitizing drugs and
may result in skin injury.
• Are photosensitive or
have other diseases
related to light sensitivity,
as device usage under
these conditions may
lead to serious injury.

5
English
• Suer from severe or
decompensated metabolic
conditions, such as diabetes,
since it may cause a
greater risk of delayed
healing and infection in
case of an adverse eect.
• Have had a skin peel or other
skin resurfacing procedures
within the last 8 weeks in
the treatment area as,
under these circumstances,
device usage may result in
stimulation of pigmentation.
Note: If you have undergone
any other aesthetic
procedures or have any
uncertainty regarding
potential side eects,
consult with your physician
before using the device.
WARNINGS
Do NOT use the device:
• On naturally dark skin
(coloured chart available
on the cover).
• If you have dark brown or
black spots such as: around
the nipples, freckles, birth
marks, moles, or blisters on
the area to be treated.
• On mucous membranes
such as: nostrils, lips of the
mouth, eyelids, ears, genital
area and the anus, as it
may lead to serious injury.
• Over piercings or any metal
items such as earrings or
jewelry on the area to be
treated, as it may cause
burns. Over areas with
tattoos or permanent
make-up, cover tattoos
or permanent make-up
with a white plaster before
treatment. Do not use the
device directly over the
tattoo or permanent make-
up, even when covered.
• On tanned skin or after sun
exposure as this can cause
serious burns or skin injury.
Avoid more than 15 minutes
of sun exposure for 4 weeks
before your treatment and
for at least 2 weeks post
treatment. If during this
period your treated skin
area is exposed to sunlight,
make sure to apply SPF
30 or higher sunscreens.
Additionally:
• Never look directly at the
light coming from the
applicator and lamp, as
it may cause eye injury.
• Never use flammable liquids
such as alcohol (including

6
English
perfumes, sanitizers, or other
applications containing
alcohol) or acetone on
the skin one hour before
using the device as it may
cause burning of the skin.
• Do not treat the same area
of skin more than once
per treatment, as it may
cause adverse eects.
CAUTIONS
• KEEP OUT OF REACH
OF CHILDREN.
• This device is not intended
for use by individuals with
reduced physical, sensory
or mental capabilities.
• Do not place, store or
use this device near
bathtubs, showers, basins
or other vessels containing
water, as it may lead to
severe electrocution.
• Do not open or repair
the device, as it may
expose you to dangerous
electrical components
which may cause serious
bodily damage.
• Do not leave the device
unattended while plugged
into the electricity, as it is
a risk of electrocution.
• Do not use the device if
any part of the device or
its accessories are: not
working properly, appear
damaged, broken, loose,
missing or wet (take extra
care since UV and IR are
emitted from this device), or
if you see or smell smoke.
• Before using this device,
make sure it is clean, dry and
intact. Cleaning instructions
are detailed under the
Cleaning & Storage section.

7
English
Severity of
Adverse Eect
Frequency of
Adverse Eect Adverse Eects
Mild Common
Skin Irritation
Skin Redness
Skin Sensitivity
Moderate Rare
Skin Burns
Scarring
Pigment Changes
Excessive Redness
and Swelling
Severe Extremely Rare Infection
Bruising
Any serious incident that has occurred in relation to the device
should be reported to us (via customer service) and to the competent
authority of the Member State in which you are a resident.
Possible Adverse Eects
When using this device according to the Instructions for Use,
adverse eects are rare. However, every aesthetic procedure
may cause some degree of adverse eects (as listed in the
table below). In case adverse eects appear, stop using
the device, and consult with your physician if necessary.
Mild adverse eects should be spontaneously relieved within
a few hours.

8
English
Device Description
1. Flashing light (internal lamp)
2. Treatment window
3. Trigger button
4. Energy level display
5. Battery status indicator
6. Energy level selection
buttons
7. Energy recommendation
button
8. ON/OFF button
9. Status Indicator
10. Skin tone and skin
contact sensor
11. Charging socket
12. Large treatment window
(0.7 sq. in/ 4.5 cm2)
13. Precise treatment window
(0.3 sq. in/ 2 cm2)
14. Power adapter
1
10
9
2
3
4
5
67
8
11
14
12
13

9
English
User interface description
1. ON/OFF button – Pressing
the button will turn the
device ON at energy
level 1. The device will
switch to standby mode
when left unattended for
5 minutes or by pressing
the ON/OFF button for 3
consecutive seconds.
2. Energy recommendation
button – A press on the
button will allow you to
detect the recommended
energy level for your
treatment, according to
your skin tone in the tested
area. When pressing the
skin tone detection button,
it will light up green and
all energy level display
indicators will flicker. Hold
the device on the desired
treatment area and press
the trigger button to
measure your skin tone (no
flash will be released). The
recommended energy level
according to your skin tone
at the treatment area will
be automatically set, as
indicated by the energy
level display. Failure to
determine suitable energy
level due to lack of contact
or not allowed skin tone
(too dark), is indicated by
a momentary red light on
the status indicator. Note
that the recommended
energy level is set only
through this procedure
and it does not occur
automatically. To test the
skin tone in each treatment
area, place the device on
that area and press the
energy recommendation
button. Performing a
preliminary test in the
desired treatment area is
still needed and selection
of energy level should be
according to your own
comfort, as determined
by the preliminary test.
3. Energy level selection
buttons – The + (increase
energy level) and –
(decrease energy level)
buttons, allow you to
choose between 6 dierent
levels. Select the energy
level according to what you
found most comfortable
in the preliminary test.
You can use the energy
recommendation button
to assist in choosing the
optimal energy level for
you for each desired
treatment area.

10
English
• Each press of the (+) or
(-) buttons will increase
or decrease the energy
by one level. When you
reach the maximum
energy level, pressing the
(+) button again won’t
change the energy level
any further. Similarly, when
you reach the minimal
energy level, pressing the
(–) button won’t decrease
the energy level further.
• The 1-6 energy level
display indicators will
light up green according
to the selected energy
level (e.g. at energy level
1, one green light will be
lit, at energy level 2, two
green lights will be lit).
4. Battery status indicator -
The indicator, marked as
, shows the charge
status of the battery:
• Red – Battery is being
charged. Note: If in
addition to this red light,
energy level “1” is green,
the device is turned on.
• Green - Battery is fully
charged, and the device
is connected to the
external power supply.
• Slow blinking red light–
Low battery level (about
30% of full charge).
• Fast blinking red light–
Very low battery level
(about 10% of full charge).
Note: The green or blinking red
battery status indicators will
appear only while the device is
turned on.
5. Treatment windows – For
the most comfortable
treatment, select the
appropriate treatment
window for the body
area you want to treat
and simply snap on the
treatment window.
• Large treatment window
(the optical filter is fixed
on the device) – Use
the large treatment
window for fast and easy
hair removal on large
body areas, such as
legs, back and arms.
• Precise treatment window
(additional snap-on
window) – Snap on the
precise treatment window
for treatment of small and
delicate areas, such as
the face (area below the
cheek line) and bikini line.

11
English
6. Status indicator
Status
Indicator Status Description
No light OFF Device is inactive
Steady
green light ON Flash is ready to
be delivered
Momentary
orange light Flash blocked
The device is not in full
contact with the skin – no
flash will be delivered
Momentary
red light Flash blocked
A non-allowed skin tone
has been detected – no
flash will be delivered
(coloured chart available
in section 02 on the cover)
Blinking
orange light
Energy
recommendation
Device ready for skin
tone measurement - no
flash will be delivered
during this time
Steady
red light Device blocked
The device is blocked
due to either an internal
malfunction or improper
attachment of treatment
window to the device

12
English
User Instructions
The device is suitable for use
on: legs, arms, underarms
bikini line, back, shoulders,
chest, stomach, and permitted
facial areas (above upper lip,
cheek, jaw, chin and neck).
What to expect
During your treatment, it
is normal to experience:
• A flash of light with each
press on the trigger
button– the emitted light
will not harm your eyes.
• A pop noise with each
flash of light.
• A mild, stinging sensation.
Preliminary Test
The preliminary test is
intended to determine your
skin's reaction to treatment
with the device and help you
set the optimal energy level
for each treatment area.
Perform a preliminary test
on a hidden patch of skin
for the area you intend
to treat 48 hours prior to
the first full treatment.
Due to varying levels of
sensitivity, body areas may
require dierent energy levels;
this will be determined by
separate preliminary tests.
Note: Do not treat full areas
with energy levels that you
have not tested before!
Do not treat the tested
area for at least 48 hours
after the preliminary test
has been carried out.
1. Prepare your skin as
described below in "Step
1: Prepare your skin".
Instructions for operating
the device can be
found below in “Step 2:
Device operation”.
2. Select the lowest energy
level and deliver a flash.
3. You can increase the
energy level as long as
it feels comfortable. You
may continue to do this up
to the maximum energy
level unless you begin to
experience discomfort.
4. If you do not feel
comfortable or see adverse
eects such as severe
redness or blistering stop
the test immediately.

13
English
5. Wait 48 hours and
examine the tested area:
• If the skin in the test
area seems normal
(there is no reaction or
just a mild redness), you
can proceed with a full
treatment on the highest
comfortable energy
level that you tested.
Note: You may use the Energy
Recommendation button
to automatically detect
the recommended energy
level for each treatment
area. Please note this is a
recommendation based on
your skin tone and you are
recommended to test that this
energy is comfortable for you.
Getting Started
Step 1: Prepare your skin
1. Remove all jewelry.
2. Make sure the hair in the
treatment area is shaved
or trimmed (between
treatments you can
shave, but don't wax or
pluck hair), and that the
skin is free of any residue
from: powders, creams,
makeup, antiperspirants
or deodorants.
3. Never use flammable
liquids such as alcohol
(including perfumes,
sanitizers, or other
applications containing
alcohol) or acetone on the
skin for one hour before
using the device, as it may
cause burning of the skin.
Important: Do not use any
cream or gel while using the
device since it may prevent
normal operation.
Remember: The device is
equipped with a built-in
skin-tone sensor, allowing the
device to work only on suitable
skin tones. This unique safety
feature will prevent a flash from
occurring on specific areas
where your skin is too dark
or too tanned, even if your
general skin type is lighter.
Step 2: Device operation
Note: A preliminary test
should be conducted before
proceeding with a full
treatment. See “Preliminary
Test” section above. Make sure
the device is clean, dry and
intact. You can use the device
while it is being charged.
However, this may limit the
number of pulses since battery
charging is slower than battery
consumption during use.

14
English
1. Charge your device
as necessary:
• Before your first use
and when the battery is
empty, fully charge the
battery (full charging
of the battery takes
up to 2.5 hours).
• Whenever battery level is
low, as indicated by the
blinking red light of the
battery status indicator.
• Fully charge the
appliance at least
once every 6 months,
even if you have not
used it in that time.
• To charge your device,
insert the plug of the
power cord into the
electrical outlet and
the other end into the
device. When the battery
is fully charged, the
charging light lights up
green continuously.
• After charging, remove
the power adapter
from the wall socket
and disconnect it
from your device.
Notes about charging:
• Some warming of the
device and power adapter
during charging is normal.
• Charging should be done
in a room temperature or
cool environment, never
above 40°C. The device
is equipped with battery-
overheat protection and
will not charge if the room
temperature exceeds 40°C.
• Never cover the appliance
and the adapter during
charging.
2. Turn the device on. When
the device is turned on it
will be automatically set to
the lowest energy level and
the energy level display
will show one green light.
You may use the energy
recommendation button at
the start of each treatment
or manually change
energy levels by pressing
the energy level selection
buttons (increase energy
level button (+) or decrease
energy level button (-).
You may decrease or
increase the energy level
according to your comfort
level, as determined by
the preliminary test.

15
English
3. Select the desired
treatment window and
simply snap it onto the
device by aligning the
plastic pins of the selected
window to the device
sockets and pressing
into place. To remove
the treatment window,
grab both sides on the
elevated dots and firmly
pull until it is removed.
4. Place the treatment
window on the desired
treatment area, ensuring
full contact with the skin.
As a safety precaution
the device is equipped
with a safety sensor that
will not trigger a flash if:
• The device is not
properly applied to the
skin. In this case, the
status indicator will turn
"momentarily" orange.
• Your skin tone is too dark/
tanned. In this case, the
status indicator will turn
“momentarily” red.
• The treatment
window is not properly
attached. In this case,
the status indicator
will turn “steady” red.
5. Apply the treatment
window firmly against your
skin and press the trigger
button to release a flash.
Following each flash, move
the device to the next spot.
After each flash, the device
will take 1-3 seconds to be
ready for the next one.
6. You may choose from 2
operational modes, the
‘Pulse mode’ or the
‘Glide mode’:
• Pulse mode: Press the
trigger button once to
release a single flash.
Continue to the next
spot and press the
trigger button again
to release another
flash. Repeat this until
treatment is complete.
• Glide mode: Begin
treatment in Pulse mode.
After three consecutive
flashes without releasing
the trigger button, the
device will automatically
enter the Glide mode. This
mode will release flashes
continuously, with a 1-3
second pause between
each one, so there is
no need to hold the
trigger button. The Glide
mode will automatically

16
English
deactivate when the
device is not in proper
contact with the skin or if
the skin tone is too dark.
7. After the treatment, turn
o the device by pressing
the “ON/OFF” button;
the status indicator will
turn orange while the
device shuts down.
8. Perform treatment
sessions according to
the “Recommended
Treatment” section.
Important note: Try not to
overlap pulses - repeated
pulses on the same spot may
cause burns.
Recommended Treatment:
Body hair:
Hair removal treatments
1–4 will be two weeks apart.
Hair removal treatments
5-8 will be four weeks apart.
Facial hair:
Hair removal treatments
1–5 will be two weeks apart.
Hair removal treatments
6-8 will be four weeks apart. To
maintain the results following
completion of the treatment
protocol, we recommend
performing a treatment once
a month, or as required.
What to expect:
Dierent individuals and
dierent treatment areas
may not react equally
to RPL technology.
You should begin to notice
a reduction in hair growth
by the 6th treatment. Once
the treatment protocol of
12 treatments is complete,
you should see further hair
growth reduction. Any hairs
that remain should be finer
and lighter in colour. In
order to maintain results,
we recommend using
the device once a month
per treatment area.
Important: Facial treatments
should be performed at the
medium or low energy level.
Don’t forget to select the
proper treatment window
(either the built-in large
treatment window or the
additional precise treatment
window), according to
the size of the treatment
area and your comfort.

17
English
Notes:
• It is recommended to use
the highest energy setting
that you found comfortable
during the preliminary test.
• Lighter hair colors may
require more treatments
in order to see results.
• The hair will continue to grow
for up to two weeks after
a hair reduction session.
However, as you progress
through the full treatment
protocol, hair will naturally
and gradually fall out. The
time until initial results can
be noticed varies between
users and depends on
factors such as: age, hair
color and skin tone.
• The number of sessions
required for achieving
long term results diers for
every treatment area and
between dierent users.
• This device is suitable for
men. However, male body
hair, especially on the
chest, will require more
treatment sessions.
• Maintenance will be
needed from time to time
if growth is still visible.
Facial treatment
The facial skin is a sensitive
area that requires special
care and caution. Make sure
you follow all instructions and
safety precautions carefully in
order to avoid adverse eects.
It is recommended you first
do a body treatment and get
to know the device before
performing facial treatments.
This device can be used
to treat all facial areas
below the cheek line, such
as: above upper lip, cheek,
jaw, chin and neck.
Never use the
device around or
near your eyes.

18
English
Warnings!
• When using this device to
treat facial areas, do not use
energy levels exceeding the
medium level, since it may
cause severe skin damage.
• Do not use the device on the
face above the cheek line or
around the eyes, eyebrows
and eyelashes as this could
cause serious eye damage.
• Avoid the nostrils and
lip, as these areas are
more sensitive.
• The skin on the lower third
of the neck is more sensitive.
Take extra care to avoid
overlapping treatment areas.
Note: Facial hair may be
hormonal and as such, it can
take more sessions to achieve
a permanent hair reduction.
For male users: Take care
while treating the beard
area; the density of hair
means a large amount of
melanin which absorbs the
heat during treatment.

19
English
Post-treatment care
• After treatment, you may
use a calming lotion.
• Avoid using peeling and
bleaching creams or
similar products for at
least 24 hours, as this
irritates the treated skin.
• Avoid direct sun exposure
for at least 2 weeks post
treatment. If exposing
recently treated skin to
sunlight during this time
period, apply sunscreen
of SPF 30 or higher.
Cleaning & Storage
1. Make sure to turn o
the device before
cleaning and storage.
2. It is recommended that
the treatment window
area be cleaned after
every session by using
a dry and clean cloth.
3. Fully charge the device
every 6 months, even if
you have not used it in
that time.
4. If there is dirt or debris on
the treatment window,
clean the treatment
window. If you can't get
the device clean, contact
our Customer Service.
Troubleshooting
If the device does not turn on:
• Make sure that the device
is charged (as indicated
by the green light at the
battery status indicator).
If the device does not
trigger a pulse:
• Verify there is full contact
between the device and
your skin. The trigger button
will activate a pulse only
when the device is in full
contact with the skin.
• Verify that the treatment
window is properly attached
to your device (the device
will not be operable if the
treatment window is not
attached or not properly
attached to the device).
• Verify that the area you are
trying to treat is not too
small, curved or bony. The
entire treatment window
should touch the treatment
area. Pulling the skin flat
can help to achieve this.

20
English
• If the skin tone identified by
the skin tone and contact
sensor is too dark, the flash
activation will be blocked,
and the status indicator will
turn “momentarily” red.
In case of general error:
• Reset the device by
unplugging the power cord
from the electrical outlet on
the wall, wait 10 seconds
and then reconnect it.
Then try turning on the
device after resetting.
• In case of dirt or debris on
the treatment window, you
should clean the treatment
window according to the
cleaning section. If you can't
get the area clean, contact
our customer service.
• In case of a pulse delay after
repositioning the device on a
dierent treatment area, you
should consider performing
the treatment in a cooler
environment. The device
may pulse at a slower rate
in a warm environment.
If the problem is not
solved, please contact
our customer service.
Device specification
parameters
Manufactured by:
ELG trade Ltd.
Emitted light spectrum:
Large treatment window:
(yellow optical filter)
475nm to 1,200nm max.
Precise treatment window:
(red optical filter)
550nm to 1,200nm max.
Pulse duration:
5 ± 2 [ms]
Emitted energy flux:
5 [J/cm2]
Selectable energy levels:
6
Treatment area:
Large treatment window:
4.5 cm2
Precise treatment window:
2 cm2
Customer Service
For more information about
the device, if your device is
broken, stopped working, or
if you need more assistance,
please contact us:
+44 0800-923-4833
supportUK@sensica.com