SIYI SYREBO SY-HRC12 User manual

SY-HRC12 User Manual
Soft Rehabilitation Glove
®
Innovative Rehabilitation Products & Services
For Clinicians & Patients
Version: V1.0
Issuance Date: 25/11/2022

封底背面

Contact Information
Important
1
Manufacturer:
Shanghai Siyi Intelligent Technology Co., Ltd.
Address: East Area Of Floor 5, No. 26, Lane 3399, Kangxin Road, Pudong New
Area, Shanghai, China, 201321
Tel: 0086 17317983724
Country of Origin: China
Website: www.syrebo.com
E-mail: [email protected]
Name: MedPath GmbH
Add: Mies-van-der-Rohe-Strasse
Tel: +49(0)89 189174474
Fax: +49(0)89 5485 8884
E-mail: info@medpath.pro
Descriptions on Environment of Use
This product is a common device that can run continuously (enclosed
device without the ability to prevent liquid from entering), and it cannot be
used in the presence of a mixture of flammable anesthetic gas and air or a
mixture of flammable anesthetic gas and oxygen or nitrous oxide. This
product may break down due to the interference of electromagnetic waves
from portable TV, radio transceiver, and electric toys, etc. Please keep it
away from these products.
Electromagnetic compatibility. This product should be kept away from the
objects that can generate strong electromagnetic waves or noise, such as
nuclear magnetic resonance equipment, microwave generator, and
radiation equipment (e.g. X-ray machine, CT machine, etc.); This product
should be kept away from high-frequency surgical instruments, such as
high-frequency electrotome, and mobile phone, etc.

Disclaimer
Contact Information
Important
12
Manufacturer:
Shanghai Siyi Intelligent Technology Co., Ltd.
Address: East Area Of Floor 5, No. 26, Lane 3399, Kangxin Road, Pudong New
Area, Shanghai, China, 201321
Tel: 0086 17317983724
Country of Origin: China
Website: www.syrebo.com
E-mail: [email protected]
Name: MedPath GmbH
Add: Mies-van-der-Rohe-Strasse
Tel: +49(0)89 189174474
Fax: +49(0)89 5485 8884
E-mail: info@medpath.pro
Intellectual Property
The intellectual property rights of this Manual and its corresponding
products are owned by Shanghai Siyi Intelligent Technology Co., Ltd.
is registered trademarks of Shanghai Siyi Intelligent Technology
Co., Ltd., and is owned solely by Shanghai Siyi Intelligent Technology Co.,
Ltd. This User Manual may not be copied, modified, translated or
distributed by any person or organization in any form without the written
consent of Shanghai Siyi Intelligent Technology Co., Ltd.
Descriptions on Environment of Use
This product is a common device that can run continuously (enclosed
device without the ability to prevent liquid from entering), and it cannot be
used in the presence of a mixture of flammable anesthetic gas and air or a
mixture of flammable anesthetic gas and oxygen or nitrous oxide. This
product may break down due to the interference of electromagnetic waves
from portable TV, radio transceiver, and electric toys, etc. Please keep it
away from these products.
Electromagnetic compatibility. This product should be kept away from the
objects that can generate strong electromagnetic waves or noise, such as
nuclear magnetic resonance equipment, microwave generator, and
radiation equipment (e.g. X-ray machine, CT machine, etc.); This product
should be kept away from high-frequency surgical instruments, such as
high-frequency electrotome, and mobile phone, etc.
All contents in this manual are written in strict accordance with relevant
national laws and regulations and the technical specifications of Shanghai
Siyi Intelligent Technology Co., Ltd., and have been strictly checked and
ensured to be correct. Shanghai Siyi Intelligent Technology Co., Ltd. is not
liable for any consequences caused by improper use. Shanghai Siyi
Intelligent Technology Co., Ltd. has the right to change the contents and
version number of this User Manual according to the changes of product
specification and the software upgrades without prior notice.The product
picture is only for reference, please make the object as the standard.
Notification
PLEASE READ THIS USER MANUAL BEFORE OPERATING THE GLOVE
Before using the Soft Rehabilitation Glove, please read this manual
carefully to have a clear understanding of its functions and operations.
Keep this manual handy so that it can be referred to whenever needed.
Follow the operating procedures and usage described in this guide.
Do not modify the device, replace any parts, use non specified parts, or
remove protection devices, as these actions could result in a hazardous
situation.

Safety instructions
Anyone other than professionals are not allowed to dismantle,
repair the device or replace the battery without authorization,
for it may cause fire, electric shock, explosions, or other dangers!
Caution
Caution
Caution
Caution
Caution
1. Please stop operation and unplug it immediately in case any
of the following conditions occurs:
1) Thunder and lightning occurs;
2) Unusual sound, smoke, or abnormal smell is found;
3) The device surface temperature is excessively high;
4) Ingress of water into the device occurs;
5) The users feel painful, tumid or has any other discomfort!
Don't recharge the device in case any of the following
conditions occurs:
1) The house is unattended or the user is out for an extended
period;
2) The user is resting at night;
3) The environment is relatively humid!
Do use the original adapter and USB cable. Any recharger other
than the original one may cause damages or malfunctions!
Don't use or recharge it at any location or environment such
as inflammable, explosive objects, bedding, sofa, or bedside to
avoid fire or other dangers!
The length of each operation should be lower than 20 minutes,
for excessive training is not in favor of your rehabilitation. The
interval between two operations should be longer than one hour.
Caution
Caution
Caution
Don't plug or unplug it with a wet hand, for it may cause
accidental electric shock or personal injuries!
Keep it away from anyone without behavior consciousness
or any infant!
Anyone with any hand sprain, trauma, unknown bone fracture,
serious osteoporosis, unprocessed fracture, or facture that
requires braking cannot use the product before the situation
is determined by any professional.
Notes
Before charging, please note that:
1) Inspect whether the socket/power strip has any potential
safety hazard;
2) Inspect whether the plug and cable protective layer are
damaged, and replace them promptly if necessary!
Notes
When using the product, don't place it on any platform or
desktop that is uneven, slant, or vibrating, or it may cause the
conditions as below:
1) The usage experience is inferior;
2) Noises are caused;
3) Any slide or drop may damage the product!
Notes
Notes
Don’t place it at any dusty location. If dust or dirt is found,
please promptly remove it and keep the surface, vent hole,
and ports clean to prevent them from lowering its service life.
Don’t use any corrosive liquid to clean the product!
34

Safety instructions
Anyone other than professionals are not allowed to dismantle,
repair the device or replace the battery without authorization,
for it may cause fire, electric shock, explosions, or other dangers!
Caution
Caution
Caution
Caution
Caution
1. Please stop operation and unplug it immediately in case any
of the following conditions occurs:
1) Thunder and lightning occurs;
2) Unusual sound, smoke, or abnormal smell is found;
3) The device surface temperature is excessively high;
4) Ingress of water into the device occurs;
5) The users feel painful, tumid or has any other discomfort!
Don't recharge the device in case any of the following
conditions occurs:
1) The house is unattended or the user is out for an extended
period;
2) The user is resting at night;
3) The environment is relatively humid!
Do use the original adapter and USB cable. Any recharger other
than the original one may cause damages or malfunctions!
Don't use or recharge it at any location or environment such
as inflammable, explosive objects, bedding, sofa, or bedside to
avoid fire or other dangers!
The length of each operation should be lower than 20 minutes,
for excessive training is not in favor of your rehabilitation. The
interval between two operations should be longer than one hour.
Caution
Caution
Caution
Don't plug or unplug it with a wet hand, for it may cause
accidental electric shock or personal injuries!
Keep it away from anyone without behavior consciousness
or any infant!
Anyone with any hand sprain, trauma, unknown bone fracture,
serious osteoporosis, unprocessed fracture, or facture that
requires braking cannot use the product before the situation
is determined by any professional.
Notes
Before charging, please note that:
1) Inspect whether the socket/power strip has any potential
safety hazard;
2) Inspect whether the plug and cable protective layer are
damaged, and replace them promptly if necessary!
Notes
When using the product, don't place it on any platform or
desktop that is uneven, slant, or vibrating, or it may cause the
conditions as below:
1) The usage experience is inferior;
2) Noises are caused;
3) Any slide or drop may damage the product!
Notes
Notes
Don’t place it at any dusty location. If dust or dirt is found,
please promptly remove it and keep the surface, vent hole,
and ports clean to prevent them from lowering its service life.
Don’t use any corrosive liquid to clean the product!
34

Before any training, ensure the proposed hand is not stiff. If the
hand is stiff, use manual methods, hot compress, or flexible
massage gloves to make the hand soft for the training.
Don't wash the gloves with water directly. Soft cloth can be
dipped in water or neutral detergent and fully wrung to wipe
the gloves. If necessary, a rag dipped with a small amount of
medicinal alcohol can be used for washing or disinfection. And
the gloves can be reused after they are fully dry.
If the product is operated continuously or for an extended
period, avoid using it in any humid area (e.g. the product is
directly placed on relatively humid ground). Place it any a dry,
ventilative area to prevent continuous high temperature from
damaging the key components and lowering its service life!
Please follow the requirements as below to guarantee proper
operation and avoid unnecessary troubles:
1) Don't plug the recharger into a socket for an extended
period to avoid damaging the recharger;
2) If the device is idle for an extended period, place it in a dry
location or a locker after it is charged. Charge it once or twice
monthly; the charging time is about 1.5 hours each time (2 grids);
the service life of the lithium battery will be compromised if it
is in zero battery level for an extended period;
3) Unplug the recharger promptly after being fully charged,
for excessive charging may lower the service life of the lithium
battery!
Notes
Notes
Notes
Notes
Symbols used in this User Manual
56
Symbol Description Symbol Description
Warning! Please refer to the
document attached!
Do not discard with
household waste
Follow the user manual
Upward
Protected from direct
sunlight
Serial number
Use by Type B applied part
Date of manufacture
CE Marking
Medical device
Electrical safety classⅡ
Authorized representative in
the E.U
Protected from radiation
Protected from rain
Frangible
Information about the
manufacturer of the device
General warning symbol

Before any training, ensure the proposed hand is not stiff. If the
hand is stiff, use manual methods, hot compress, or flexible
massage gloves to make the hand soft for the training.
Don't wash the gloves with water directly. Soft cloth can be
dipped in water or neutral detergent and fully wrung to wipe
the gloves. If necessary, a rag dipped with a small amount of
medicinal alcohol can be used for washing or disinfection. And
the gloves can be reused after they are fully dry.
If the product is operated continuously or for an extended
period, avoid using it in any humid area (e.g. the product is
directly placed on relatively humid ground). Place it any a dry,
ventilative area to prevent continuous high temperature from
damaging the key components and lowering its service life!
Please follow the requirements as below to guarantee proper
operation and avoid unnecessary troubles:
1) Don't plug the recharger into a socket for an extended
period to avoid damaging the recharger;
2) If the device is idle for an extended period, place it in a dry
location or a locker after it is charged. Charge it once or twice
monthly; the charging time is about 1.5 hours each time (2 grids);
the service life of the lithium battery will be compromised if it
is in zero battery level for an extended period;
3) Unplug the recharger promptly after being fully charged,
for excessive charging may lower the service life of the lithium
battery!
Notes
Notes
Notes
Notes
Symbols used in this User Manual
56
Symbol Description Symbol Description
Warning! Please refer to the
document attached!
Do not discard with
household waste
Follow the user manual
Upward
Protected from direct
sunlight
Serial number
Use by Type B applied part
Date of manufacture
CE Marking
Medical device
Electrical safety classⅡ
Authorized representative in
the E.U
Protected from radiation
Protected from rain
Frangible
Information about the
manufacturer of the device
General warning symbol

Combined with soft exoskeleton technology and neuroscience, Syrebo®
soft rehabilitation glove is powered by the flexible pneumatic bionic
muscles that help users to move and re-learn, so as to improve hand
mobility and accelerate the process of hand function rehabilitation from
three levels of nerves, brain and muscles.
Button area
Charging port
Data glove
Display area
Power port
1. Product introduction
Power glove
Please charge
before first use.
If poor signal
please charge.
Please charge at
least once a month.
Blue-Working
White-Charging
Green-Fully chargde
Smart Data Glove
78
Content
Contact Information ------------------------------------------------------------------------------------ 1
Important--------------------------------------------------------------------------------------------------- 1
Disclaimer -------------------------------------------------------------------------------------------------- 2
Notification------------------------------------------------------------------------------------------------- 2
Safety instructions---------------------------------------------------------------------------------------- 3
Symbols used in this User Manual-------------------------------------------------------------------- 6
1. Product introduction --------------------------------------------------------------------------------- 8
2. Panel description ------------------------------------------------------------------------------------- 9
2.1 Button instruction--------------------------------------------------------------------------------- 9
2.2 Icon instruction ---------------------------------------------------------------------------------- 10
3. Instructions for wearing gloves ------------------------------------------------------------------ 11
4. Function description-------------------------------------------------------------------------------- 12
4.1 Passive training ---------------------------------------------------------------------------------- 12
4.2 Pinching training -------------------------------------------------------------------------------- 13
4.3 Extend training ----------------------------------------------------------------------------------- 14
4.4 Fine motor training ----------------------------------------------------------------------------- 14
4.5 Functional training------------------------------------------------------------------------------ 15
4.6 Mirror training------------------------------------------------------------------------------------ 16
5. Ancillary functions ---------------------------------------------------------------------------------- 17
5.1 Mandatory rest----------------------------------------------------------------------------------- 17
5.2 Auto power-off ----------------------------------------------------------------------------------- 17
5.3 Parameter storage------------------------------------------------------------------------------- 17
6. Product specifications------------------------------------------------------------------------------ 18
7. Packing list -------------------------------------------------------------------------------------------- 18
8. Cleaning and maintenance------------------------------------------------------------------------ 19
9. Repair policy ------------------------------------------------------------------------------------------ 19
10. Disposal ---------------------------------------------------------------------------------------------- 20
11. Warranty---------------------------------------------------------------------------------------------- 20
12. Appendix A------------------------------------------------------------------------------------------- 21

Combined with soft exoskeleton technology and neuroscience, Syrebo®
soft rehabilitation glove is powered by the flexible pneumatic bionic
muscles that help users to move and re-learn, so as to improve hand
mobility and accelerate the process of hand function rehabilitation from
three levels of nerves, brain and muscles.
Button area
Charging port
Data glove
Display area
Power port
1. Product introduction
Power glove
Please charge
before first use.
If poor signal
please charge.
Please charge at
least once a month.
Blue-Working
White-Charging
Green-Fully chargde
Smart Data Glove
78
Content
Contact Information ------------------------------------------------------------------------------------ 1
Important--------------------------------------------------------------------------------------------------- 1
Disclaimer -------------------------------------------------------------------------------------------------- 2
Notification------------------------------------------------------------------------------------------------- 2
Safety instructions---------------------------------------------------------------------------------------- 3
Symbols used in this User Manual-------------------------------------------------------------------- 6
1. Product introduction --------------------------------------------------------------------------------- 8
2. Panel description ------------------------------------------------------------------------------------- 9
2.1 Button instruction--------------------------------------------------------------------------------- 9
2.2 Icon instruction ---------------------------------------------------------------------------------- 10
3. Instructions for wearing gloves ------------------------------------------------------------------ 11
4. Function description-------------------------------------------------------------------------------- 12
4.1 Passive training ---------------------------------------------------------------------------------- 12
4.2 Pinching training -------------------------------------------------------------------------------- 13
4.3 Extend training ----------------------------------------------------------------------------------- 14
4.4 Fine motor training ----------------------------------------------------------------------------- 14
4.5 Functional training------------------------------------------------------------------------------ 15
4.6 Mirror training------------------------------------------------------------------------------------ 16
5. Ancillary functions ---------------------------------------------------------------------------------- 17
5.1 Mandatory rest----------------------------------------------------------------------------------- 17
5.2 Auto power-off ----------------------------------------------------------------------------------- 17
5.3 Parameter storage------------------------------------------------------------------------------- 17
6. Product specifications------------------------------------------------------------------------------ 18
7. Packing list -------------------------------------------------------------------------------------------- 18
8. Cleaning and maintenance------------------------------------------------------------------------ 19
9. Repair policy ------------------------------------------------------------------------------------------ 19
10. Disposal ---------------------------------------------------------------------------------------------- 20
11. Warranty---------------------------------------------------------------------------------------------- 20
12. Appendix A------------------------------------------------------------------------------------------- 21

2. Panel description
2.1 Button instruction
F
A. Flex+: Adjusting flexion grade/power.
B. Power: Tap it to switch to power adjustment; when adjusting, the
indicators corresponding to bend status, bend parameters, power,
extend status, and extend parameter flicker.
C. On-Off/Start-Pause: Press for 2s to turn it on; tap to start/pause the
operation.
D.
Mode switch: Passive training, Fine motor training, Pinching training,
Functional training, Extend training, and Mirror training.
E. Extend+: Adjusting extend grade/power.
F. Finger button: The button can be chosen in passive mode only, and it's
invalid in other modes; At any time in passive mode, tap any of five finger
buttons to switch on or off the training for the corresponding finger.
A
B
C D E
Thumb Index Middle Ring Little
Passive
Pinch
Extend
Functional
Fine Motor
Mirror
Power
RestFlexion Extension
910
Thumb Index Middle Ring Little
Passive
Pinch
Extend
Functional
Fine Motor
Mirror
Power
RestFlexion Extension
A
C
E F HG
B
D
2.2 Icon instruction
A. Individual finger training indicator:
①In the passive mode, it indicates the individual finger training on/off
status; ②In other modes, it is on when the fingers are bending and off
when fingers are extending.
B. Battery indicator:
①It is on and off after the device is switched on and off; ②It flickers if the
battery level is low; ③During charging, it flickers; after battery level >95%,
it stays on for 5 minutes it stays on for 5 minutes and then automatically
lights out, and the machine is off and starts low-power mode; ④When the
battery level <5%, it cannot be turned on without charging.
C/D. Training mode:
The indicator is on after corresponding training mode is started.
E. Flexion grade/power:
It indicates current flexion grade/power. The last status is indicated by
default after it is switched on.
I

2. Panel description
2.1 Button instruction
F
A. Flex+: Adjusting flexion grade/power.
B. Power: Tap it to switch to power adjustment; when adjusting, the
indicators corresponding to bend status, bend parameters, power,
extend status, and extend parameter flicker.
C. On-Off/Start-Pause: Press for 2s to turn it on; tap to start/pause the
operation.
D.
Mode switch: Passive training, Fine motor training, Pinching training,
Functional training, Extend training, and Mirror training.
E. Extend+: Adjusting extend grade/power.
F. Finger button: The button can be chosen in passive mode only, and it's
invalid in other modes; At any time in passive mode, tap any of five finger
buttons to switch on or off the training for the corresponding finger.
A
B
C D E
Thumb Index Middle Ring Little
Passive
Pinch
Extend
Functional
Fine Motor
Mirror
Power
RestFlexion Extension
910
Thumb Index Middle Ring Little
Passive
Pinch
Extend
Functional
Fine Motor
Mirror
Power
RestFlexion Extension
A
C
E F HG
B
D
2.2 Icon instruction
A. Individual finger training indicator:
①In the passive mode, it indicates the individual finger training on/off
status; ②In other modes, it is on when the fingers are bending and off
when fingers are extending.
B. Battery indicator:
①It is on and off after the device is switched on and off; ②It flickers if the
battery level is low; ③During charging, it flickers; after battery level >95%,
it stays on for 5 minutes it stays on for 5 minutes and then automatically
lights out, and the machine is off and starts low-power mode; ④When the
battery level <5%, it cannot be turned on without charging.
C/D. Training mode:
The indicator is on after corresponding training mode is started.
E. Flexion grade/power:
It indicates current flexion grade/power. The last status is indicated by
default after it is switched on.
I

11 12
F. Rest:
It is on when the mandatory rest is triggered, and it is off after exiting (See
Auxiliary function ‒ Mandatory rest according to specific rules).
G. Power:
The indicator is on when power is being adjusted (Adjustable range:
Flexion: 01-09; Extension: 01-09).
H. Extension grade/power:
It indicates current extension grade/power, and the last status is
indicated by default after it is switched on.
I. Time indicator: It records the training duration.
(3)Tighten the Velcro strap from the end of the thumb on
the back through the thumb and index finger, to the palm
and finish wearing glove.
(1)Fingers are threaded
into the ends of the
gloves in turn.
(2)Pull the Velcro of
the glove to the wrist
and fasten it.
Tip:
All fingers should
reach the top of the
glove.
Tip:
Pull down the end of
the finger sleeve on
the palm side as far as
you can.
Tip:
Please wear it correctly and make sure that
there is no gap between the wrist and the
glove when making a fist.
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn on
the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the passive training mode.
When the passive mode icon indicator is on, press the "flex +/extend+"
button to adjust the dwell time of the action to suit the patient's own speed.
(Time adjustment range: flexion 0-15s, extension 0-15s.)
3. Press the power button to enter the power adjustment mode, and
the indicators of power and the corresponding value on the screen will
light up and flash synchronously. Press the flex +/extend + button to adjust
the power value that suits you. If no operation happens within 3 seconds,
the adjusted data is automatically saved, and exits the mode.
4. Keeping the affected hand in a "functional position" or "resting
position" is conducive to the recovery effect.
5. Press the "on-off/start-pause" button, the power glove can drive
the affected hand to do passive training.
6. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Functional position of hand Resting position of hand
Before using, ensure the battery is full charged (≥1 grid) or it is plugged.
Prolonged empty power will cause irreversible damage to the battery and
lose training records. Please recharge it promptly and maintain correct
using habits.
4.1 Passive training
30°
3. Instructions for wearing gloves
4. Function description

11 12
F. Rest:
It is on when the mandatory rest is triggered, and it is off after exiting (See
Auxiliary function ‒ Mandatory rest according to specific rules).
G. Power:
The indicator is on when power is being adjusted (Adjustable range:
Flexion: 01-09; Extension: 01-09).
H. Extension grade/power:
It indicates current extension grade/power, and the last status is
indicated by default after it is switched on.
I. Time indicator: It records the training duration.
(3)Tighten the Velcro strap from the end of the thumb on
the back through the thumb and index finger, to the palm
and finish wearing glove.
(1)Fingers are threaded
into the ends of the
gloves in turn.
(2)Pull the Velcro of
the glove to the wrist
and fasten it.
Tip:
All fingers should
reach the top of the
glove.
Tip:
Pull down the end of
the finger sleeve on
the palm side as far as
you can.
Tip:
Please wear it correctly and make sure that
there is no gap between the wrist and the
glove when making a fist.
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn on
the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the passive training mode.
When the passive mode icon indicator is on, press the "flex +/extend+"
button to adjust the dwell time of the action to suit the patient's own speed.
(Time adjustment range: flexion 0-15s, extension 0-15s.)
3. Press the power button to enter the power adjustment mode, and
the indicators of power and the corresponding value on the screen will
light up and flash synchronously. Press the flex +/extend + button to adjust
the power value that suits you. If no operation happens within 3 seconds,
the adjusted data is automatically saved, and exits the mode.
4. Keeping the affected hand in a "functional position" or "resting
position" is conducive to the recovery effect.
5. Press the "on-off/start-pause" button, the power glove can drive
the affected hand to do passive training.
6. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Functional position of hand Resting position of hand
Before using, ensure the battery is full charged (≥1 grid) or it is plugged.
Prolonged empty power will cause irreversible damage to the battery and
lose training records. Please recharge it promptly and maintain correct
using habits.
4.1 Passive training
30°
3. Instructions for wearing gloves
4. Function description

13 14
1. With the groove side up, insert the power glove plug parallelly to
the "power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the pinching training. When
pinching training indicator is on, press the "flex +/extend+" button to adjust
the dwell time of the action to suit the patient's own speed. (Time adjustment
range: flexion 01-06s, extension 01-06s.)
3. Press the "on-off/start-pause" button, the power glove can drive the
affected hand to do pinching training according the loop instructions of the
"action library①".
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library①: open the hand, pinch the thumb and index finger;
open the hand, pinch the thumb and the middle finger; open the hand,
pinch the thumb and the ring finger; open the hand, pinch the thumb and
the little finger.
2. The finger indicators are off by default in the pinching training mode,
and the corresponding finger indicators will be turned on sequentially as
the action library command changes.
Finger button mode
(can be adjusted by touching the corresponding finger button)
1. This adjustment is only possible in passive mode.
2. By default, all finger buttons are turned on, and the corresponding
finger indicator is on. When selecting finger to train, press the button to
turn off the corresponding Finger button, and press again to turn it on.
3. The trainings of five fingers cannot be all turned off; at least the
training of one finger must be turn on.
4.2 Pinching training
4.4 Fine motor training
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn on
the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the fine motor training.
When fine motor training indicator is on, press the "flex +/extend+" button to
adjust the dwell time of the action to suit the patient's own speed. (Time
adjustment range: flexion 01-06s, extension 01-06s.)
3. Press the "on-off/start-pause" button, the power glove can drive
the affected hand to do fine motor training according the loop instructions
of the "action library③".
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the extend training, the
extend training indicator is on. The duration is not adjustable in this mode
(default keep stretching the hand statically for 30s).
3. Press the "on-off/start-pause" button, the power glove can drive the
affected hand to do extend training according the loop instructions of the
"action library②".
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library②: open the hand, relax the hand.
2. The finger indicators are not displayed by default in the extend
training mode.
4.3 Extend training

13 14
1. With the groove side up, insert the power glove plug parallelly to
the "power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the pinching training. When
pinching training indicator is on, press the "flex +/extend+" button to adjust
the dwell time of the action to suit the patient's own speed. (Time adjustment
range: flexion 01-06s, extension 01-06s.)
3. Press the "on-off/start-pause" button, the power glove can drive the
affected hand to do pinching training according the loop instructions of the
"action library①".
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library①: open the hand, pinch the thumb and index finger;
open the hand, pinch the thumb and the middle finger; open the hand,
pinch the thumb and the ring finger; open the hand, pinch the thumb and
the little finger.
2. The finger indicators are off by default in the pinching training mode,
and the corresponding finger indicators will be turned on sequentially as
the action library command changes.
Finger button mode
(can be adjusted by touching the corresponding finger button)
1. This adjustment is only possible in passive mode.
2. By default, all finger buttons are turned on, and the corresponding
finger indicator is on. When selecting finger to train, press the button to
turn off the corresponding Finger button, and press again to turn it on.
3. The trainings of five fingers cannot be all turned off; at least the
training of one finger must be turn on.
4.2 Pinching training
4.4 Fine motor training
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn on
the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the fine motor training.
When fine motor training indicator is on, press the "flex +/extend+" button to
adjust the dwell time of the action to suit the patient's own speed. (Time
adjustment range: flexion 01-06s, extension 01-06s.)
3. Press the "on-off/start-pause" button, the power glove can drive
the affected hand to do fine motor training according the loop instructions
of the "action library③".
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the extend training, the
extend training indicator is on. The duration is not adjustable in this mode
(default keep stretching the hand statically for 30s).
3. Press the "on-off/start-pause" button, the power glove can drive the
affected hand to do extend training according the loop instructions of the
"action library②".
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library②: open the hand, relax the hand.
2. The finger indicators are not displayed by default in the extend
training mode.
4.3 Extend training

15 16
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library③: open the hand, bend the thumb, extend the thumb,
bend the index finger, extend the index finger, bend the middle finger,
extend the middle finger, bend the ring finger, extend the ring finger, bend
the little finger, extend the little finger, make a fist.
2. The finger indicators are not displayed by default in the fine motor
training mode, and the corresponding finger indicators are lit sequentially
as the action library command changes.
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the functional training.
When functional training indicator is on, press the "flex +/extend+" button
to adjust the dwell time of the action to suit the patient's own speed.
(Time adjustment range: flexion 01-06s, extension 01-06s.)
3. Press the "on-off/start-pause" button, the power glove can drive the
affected hand to do functional training according the loop instructions of
the "action library④".
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library④: open the hand, two fingers pinch, open the hand,
three fingers pinch, open the hand, four fingers pinch, open the hand,
make a fist.
4.5 Functional training
4. During training, the patient's active consciousness needs to focus
on the coordinated movement of the two hands, which helps to improve
the training effect.
5. When mastered, the affected hand can try to grasp small objects
under the grasp of the healthy hand to increase self-awareness and hand
tactile stimulation.
6. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the mirror training, the
mirror training indicator is on. The speed is not adjustable in this mode.
3. Press the "on-off/start-pause" button, the healthy hand makes a fist
and drives the affected hand to grasp something synchronously; the
healthy hand is stretched out and drives the affected hand to be stretched
synchronously. So that the healthy hand drives the affected to do training
synchronously and coordinately.
4.6 Mirror training
Healthy
hand
Hands clenched synchronously Hands open synchronously
Affected
hand
Healthy
hand
Affected
hand
2. The finger indicators are not displayed by default in the functional
training mode, and the corresponding finger indicators are lit sequentially
as the action library command changes.

15 16
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library③: open the hand, bend the thumb, extend the thumb,
bend the index finger, extend the index finger, bend the middle finger,
extend the middle finger, bend the ring finger, extend the ring finger, bend
the little finger, extend the little finger, make a fist.
2. The finger indicators are not displayed by default in the fine motor
training mode, and the corresponding finger indicators are lit sequentially
as the action library command changes.
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the functional training.
When functional training indicator is on, press the "flex +/extend+" button
to adjust the dwell time of the action to suit the patient's own speed.
(Time adjustment range: flexion 01-06s, extension 01-06s.)
3. Press the "on-off/start-pause" button, the power glove can drive the
affected hand to do functional training according the loop instructions of
the "action library④".
4. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
Tips:
1. Action library④: open the hand, two fingers pinch, open the hand,
three fingers pinch, open the hand, four fingers pinch, open the hand,
make a fist.
4.5 Functional training
4. During training, the patient's active consciousness needs to focus
on the coordinated movement of the two hands, which helps to improve
the training effect.
5. When mastered, the affected hand can try to grasp small objects
under the grasp of the healthy hand to increase self-awareness and hand
tactile stimulation.
6. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
1. With the groove side up, insert the power glove plug parallelly to the
"power port" of the host, press the "on-off" button for 2 seconds to turn
on the host, and wear the power glove on the affected hand.
2. Press the mode switch button and choose the mirror training, the
mirror training indicator is on. The speed is not adjustable in this mode.
3. Press the "on-off/start-pause" button, the healthy hand makes a fist
and drives the affected hand to grasp something synchronously; the
healthy hand is stretched out and drives the affected hand to be stretched
synchronously. So that the healthy hand drives the affected to do training
synchronously and coordinately.
4.6 Mirror training
Healthy
hand
Hands clenched synchronously Hands open synchronously
Affected
hand
Healthy
hand
Affected
hand
2. The finger indicators are not displayed by default in the functional
training mode, and the corresponding finger indicators are lit sequentially
as the action library command changes.

17 18
Soft rehabilitation glove
SY-HRC12
135×145×65mm
9V
1.5A
Product name
Model
Size
Rated charging voltage
Rated charging current
Special statement:
If the specifications, appearance, color, performance and accessories of the product
are changed, the actual product shall prevail without prior notice.
Quantity
1
Name
User manual
(including warranty card*1)
Host
Data glove
1
1
Quantity
1
Name
Power glove
Quality certificate
Adaptor
1
1
6. Product specifications
7. Packing list
1. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
2. The mandatory rest is triggered when the machine has been running
continuously for 40 minutes. Training is not possible in this mode, and the
countdown begins; When the countdown ends, the forced rest mode is
automatically exited
5.1 Mandatory rest
1. If there is no training and no operation within five minutes, it will be
power-off automatically shut down.
5.2 Auto power-off
1. The host automatically saves the current mode/ extension/ flexion/
finger button parameter values, and automatically restores them the next
time it is turned on.
2. If the last shutdown mode is an unpredictable abnormal state, it will
automatically switch to passive training mode when it is turned on again.
5.3 Parameter storage
Tip: The finger indicators are not displayed by default in the functional
training mode.
5. Ancillary functions

17 18
Soft rehabilitation glove
SY-HRC12
135×145×65mm
9V
1.5A
Product name
Model
Size
Rated charging voltage
Rated charging current
Special statement:
If the specifications, appearance, color, performance and accessories of the product
are changed, the actual product shall prevail without prior notice.
Quantity
1
Name
User manual
(including warranty card*1)
Host
Data glove
1
1
Quantity
1
Name
Power glove
Quality certificate
Adaptor
1
1
6. Product specifications
7. Packing list
1. After 20 minutes of training, the machine will automatically stop
training and the patient should take a rest. To avoid overtraining, please
rest for at least one hour before next training.
2. The mandatory rest is triggered when the machine has been running
continuously for 40 minutes. Training is not possible in this mode, and the
countdown begins; When the countdown ends, the forced rest mode is
automatically exited
5.1 Mandatory rest
1. If there is no training and no operation within five minutes, it will be
power-off automatically shut down.
5.2 Auto power-off
1. The host automatically saves the current mode/ extension/ flexion/
finger button parameter values, and automatically restores them the next
time it is turned on.
2. If the last shutdown mode is an unpredictable abnormal state, it will
automatically switch to passive training mode when it is turned on again.
5.3 Parameter storage
Tip: The finger indicators are not displayed by default in the functional
training mode.
5. Ancillary functions