Lifetime Limited Warranty
Strong™ Mounts have a Lifetime Limited Warranty. This warranty includes parts and labor repairs on all components
found to be defective in material or workmanship under normal conditions of use. This warranty shall not apply to prod-
ucts which have been abused, modied or disassembled. Products to be repaired under this warranty must be returned
to SnapAV or a designated service center with prior notication and an assigned return authorization number (RA).
For Technical Support call 1.866.838.5052
Lifetime
100823
SM-CEILING-T-M
SM-CEILING-DT-M
Strong™ Medium Ceiling Mount and Dual Ceiling Mount
for 22-40 in. Flat Panel TVs (Black)
d. Install Ceiling Plate Covers over ends of
Ceiling Plate (optional).
Step 3: Attach the Mount Head
a. Screw the Mount Head on to the end of the
Extension Pole and tighten Set Screw (Fig 3).
Step 4: Attach the Adapter Plate
to the Display
a. Attach the Adapter Plate to the display
using M4, M5, M6, or M8 screws. For
displays with a hole pattern in a pocket
or inputs behind Adapter Plate, spacers
go between Adapter Plate and display
(Fig 4).
Step 5: Attaching the Adapter Plate with
Display to Ceiling Mount Assembly
a. Attach mount head to end of extension pole
and tighten set screws.
b. Attach Adapter Plate and Display onto Wall
Arm Assembly, ensuring all 3 hooks slide into
holes of Mount Head (Fig 5).
c. Using a Philips Head Screwdriver, tighten
down Locking Screw located on Adapter
Plate into threaded hole in the Mount Head.
ADJUSTMENTS
Adjust Tilt
Tilt Adjustment
a. Loosen screws on side of mount head. (Only enough to allow
controlled adjustment)
b. Adjust Tilt forward or backward
c. Tighten screws on side of mount head to hold tilt.
Fig 4
Fig 5
Fig 3
SM-CEILING-DT-M SM-CEILING-T-M

WARNINGS
•Wehighlyrecommendthisproductbeinstalledbyaqualiedprofessional.
•Pleasedonotbegininstallationuntilyouhavethoroughlyreadand
understood these instructions.
•Thismountsupportsdisplaymountingfrom22”to40”,VESA75X75,100x100,
200x100 & 200x200, and supports a maximum load of 80 lbs (36.4 kg).
•Ensurethewallthatyouplantousewillsafelysupportfourtimesthe
combined weight of the mount and your chosen display.
•Undernocircumstancesshouldthisproductbemountedtometalstuds.
•Themanufacturerdoesnotacceptresponsibilityforincorrectinstallation.
SPECIFICATIONS
•MaximumLoad:80lbs.(36.4kg)
•DisplaySize:22”to40”
•Extension:3’
•Pan/SwivelRange:360°
•TiltRange:+0°/-20°
TOOLS REQUIRED
•PowerDrill
•3/16”(5mm)DrillBit
•5/16”(8mm)MasonryBit
•PhillipsHeadScrewDriver
•3/8”SocketHeadWrench
•7/16”SocketHeadWrench
INSTALLATION INSTRUCTIONS
Step 1: Use Ceiling Plate to Mark Mounting Hole Locations
a. The use of a stud nder is highly recommended.
Step 2: Mount the Ceiling Plate
For Mounting on a Wood Joist (Fig 1)
a.Pre-drilltwoholesintojoistusinga3/16”drillbit.
Besuretodrillintothecenterofthejoists.
b. Insert two Lag Screws into holes through
the Ceiling Plate and tighten down.
WARNING: Tighten screws so that the
Ceiling Plate is rmly attached, but
do not over tighten. Over tightening
can damage the screws, greatly
reducing their holding strength.
c. Thread in extension pipe and
tighten set screws provided.
d. Install Ceiling Plate Cover (optional).
For Mounting on a Concrete Ceiling (Fig 2)
a. Pre-drillfourholesintoconcreteusing5/16”Masonrybit.InsertHexSleeveanchors
(not supplied) and tap in with hammer (per instructions with wall anchor).
WARNING:WheninstallingCeilingPlateon cinder block, verify rst that you
haveaminimumof1-3/8”ofconcretethicknesstobeusedfortheConcrete
WallAnchors(notincluded).Donotdrillintomortarjoints!Besuretomount
inasolidpartoftheblock,generally1”minimumfromthesideofthe
block. Cinder block must meet ASTM C-90 specications. It is suggested
that a standard electric drill on slow setting
is used to drill the hole instead of a hammer
drill to avoid breaking out the back of the
hole when entering a void or cavity.
Concrete must be 2000 psi density
minimum. Lighter density concrete
may not hold concrete anchor.
Make sure that the supporting surface will
safely support the combined load of the
equipmentandallattachedhardware
and components.
b. Remove washer and nut from end of bolt from
all four bolts. Place Ceiling Plate over bolts so they
align with the four holes in Ceiling Plate.
c. Re-install washer and nut onto end of bolt and tighten down
usinga7/16”socketheadwrenchuntilsecure(perinstructions
with wall anchor). WARNING: Tighten nuts so that ceiling plate is rmly attached,
but do not over tighten. Over tightening can damage the bolts, greatly reducing their
holding strength.
HARDWARE KIT (T/DT)
M4 x 12mm Philips
Head Screw (x4/8)
M6 x 12mm Philips
Head Screw (x4/8)
M8 x 14mm Philips
Head Screw (x4/8)
Allen Wrench, 2.5mm,
Security/Non-Security (x2)
Allen Wrench, 4mm (x1)
M4 x 30mm Philips
Head Screw (x4/8)
M5 x 30mm Philips
Head Screw (x4/8)
M6 x 30mm Phillips
Head Screw (x4/8)
M5 x 12mm Philips
Head Screw (x4/8)
M6 x 20mm Philips
Head Screw (x4/8)
M6 (17.8 x 6.5 x 1.5mm)
Metal Washer (x4/8)
BOX CONTENTS (T/DT):
•CeilingPlate(1)
•CeilingPlateCover(1)
•MountHead(1)
•AdapterPlate(1/2)
•Hardwarekit(1)
•3’FixedExtensionPole(1)
Fig 1
Fig 2
#14 x 2.5” Lag Screw (x4)
M8 (20.5 x 8.5 x 2mm)
Metal Washer (x8/16)
M4/M5/M6 spacer:
12mm (x4)
M5 x 5mm Set Screw (x4) M5 x 5mm Set Screw,
Security (x4)
Concreteanchorsnotprovided.5/16”x2-1/2”RedHead®HexSleeveAnchors,#50113,
are recommended for concrete or cinder block installation.
CAUTION:
These ceiling mounts are
intended for use only with
the maximum weight of
80 lbs (36.4kg).
This manual suits for next models
1
Popular Rack & Stand manuals by other brands

MINOURA
MINOURA 971-3 instruction manual

CHIEF
CHIEF MSB-6134 installation instructions

Atdec
Atdec AWMS-2-BT75-FS installation guide

Humanscale
Humanscale Thin Client Holder installation instructions

NEC
NEC LCD8205 - MultiSync - 82" LCD Flat Panel... Specifications

HRS
HRS SXR Instructions for installation and use