SpaDealers JSD?12L User manual

OWNER’SMANUAL
AUTOMATICINSTANTGASWATERHEATER
OPERATINGINSTRUCTIONS
Whenoperatingthegaswaterheateralwaysmakesurethatthereisgoodventilation.Duringoperationthe
gaswaterheaterwillproducecarbonmonoxidewhichisharmfulifinhaledinlargequantities.Itis
thereforeimportantthatallusersstrictlyobservetheproperinstallationinstructionsanduseasprescribed
inthismanual..Unlessotherwiseauthorized,refittingofthisproductbyotherthanauthorizedand
qualifiedpersonnelwillrenderthewarrantyvoidandweshallholdourselvesfreefromanyliabilitiesin
caseofaccidents.
IMPORTANTINFORMATION
Readallinstructionsbeforeusingtheheater
Protecttheheaterfromrainandwind,evenfrom
waterthatcanflowovertheedge,usefor
instance,SpaDealersprotectivebox
Asgas,propane(LPG)with30mbarpressure
reducerand2kg/hofgasflowisused
Naturalgas(methane)20mbaroperating
pressurecanalsobeused
Placethesuppliedrubbersealbetweenthebrass
connectorandgasinletonthestove
Checkthattherearenogasleaksbeforethe
stoveisused
Atfreezingtemperaturesthestoveshouldbe
disconnectedandstoredinawarmplaceto
preventfreezingdamage
Alsoremembertoemptytheconnectionhoses
Readinformationaboutinsulationandhowit
makesuseinwintereasier
Observeseparateinformationonhowthegas
pressureaffectsthefunction
Ifyouhaveanyquestions,contactusat

CONTENTS
FEATURES.............................................................................................................................................................2
INSTALLATIONREGULATIONS....................................................................................................................................4
INSTALLATION........................................................................................................................................................5
LOADINGTHEBATTERY...................................................................................................................................5
INSTALLATIONOFGASPIPE......................................................................................................................................5
INSTALLATIONOFHOTANDCOLDWATERPIPE...........................................................................................................6
USERINSTRUCTIONS...............................................................................................................................................6
THEGASPIPEMAYBECOMECRACKEDANDLEAKGASDUETOLONGTIMEUSE.INSPECTITREGULARLY...................................7
INCASEOFGASLEAKAGE,NEVERMAKEAFIREORTOUCHANYELECTRICSWITCHES,NOTMAKETELEPHONECALLINTHE
ROOM,OPENALLDOORSANDWINDOWS...............................................................................................................7
PREVENTFIRE........................................................................................................................................................8
PREVENTOXYGENDEPLETIONANDINCOMPLETEBURNING...................................................................................8
PREVENTBURNSONEYES................................................................................................................................8
OTHERIMPORTANTCAUTIONS.........................................................................................................................8
REPLACETHEBATTERIES..................................................................................................................................9
HOWTOREPLACETHEBATTERIES:SEEPARAGRAPH“LOADINGTHEBATTERY”FORDETAIL..........................................9
ABNORMALHANDLE.......................................................................................................................................9
MAINTENANCE&SERVICES..............................................................................................................................9
TROUBLE&TROUBLESHOOTING.............................................................................................................................10
OW121201HIT2188
Gaswaterheater
AppliancetypeB11BS
ModelJSD‐12L
TypeofgasI3P:G31–30mbar,3000Pa
2E:G20–20mbar,2000Pa
Applicablewaterpressure0.25Bar‐10Bar,0.025–10
MPa
Hotwatersupplycapacity12L/min△t=25℃
Minimumoutput8KW
Nominalheatinput24KW
VoltageDC3V
DestinationFinland
Caution:
Readthetechnicalinstructionsbefore
installingtheappliance
Readtheuser’sinstructionsbeforelighting
theappliance
Thisapplianceshallonlybeinstalled
outsideorinaroomseparatedfrom
inhabitedrooms,incorporatingappropriate
ventilation
Thisappliancemayonlybeinstalledina
roomiftheroommeetstheappropriate
ventilationrequirement

FEATURES
1Watercontrolled,fullyautomaticandeasytooperate.Openthewatervalve,startpumpto
startignition.Thehotwaterwillcomeoutimmediately.
2Closethewatervalve,stoppump.Thehotwaterstopsandtheflamegoesoutimmediately.
3Abilitytostartatverylowwaterpressure,applicableformanyplaces.
4Iftheflamegoesoutunexpectedlyduringuse,thegassupplywillshutoffautomaticallyto
protectagainstgasleakage.
5Ifthewaterpressureistoohigh,thewaterwillcomeoutfromthesecurityvalvetorelease
pressure,ensuringsafetyfortheapplianceandtheuser.
6Equippedwithaprotectionunittopreventover‐heatinginthewatertankand“dry‐burn”.
7Intheeventofpressurefluctuationsinthewatersupply,thewaterheaterwillmaintaina
relativelyconstantoutletwaterflow.
(Thisinstructionisforthefunctionsoftheexternalhousingonly,anddoesnotrepresenttheexternalshape
ofothermodels.)
13
11
10
12
9
8
7
6
5
1
2
3
1
4
(Fig.1)
1. Airinput
2. Warningstitch
3. Technicallabel
4. Smokedischargejoint
5. Gasflow
6. Burners
7. Waterflow
8. Batterybox
9. Waterinlet(cold)
10. Wateroutlet(hot)
11. Ignitionswitch
12. Safetyvalve
13. Gasinlet
Outer structure

INSTALLATIONREGULATIONS
1. Itisforbiddentoinstallthiswaterheaterinaclosedroom.
Itmustbeinstalledinawell‐ventilatedarealargerthan
7.5㎡.Becausethewaterheaterrequiresalargerquantity
ofoxygenwhenworking,theareashouldhaveaminimum
air‐inductionopeningof0.06㎡(20x30cm).
2. Donotinstallthewaterheaterinalocationwithstrong
wind(unlessitisprotectedfromthewind);otherwise,the
flamemaygooutorcauseincompleteburning.
3. Itisforbiddentoinstalltheheateroutsideifit’snot
protectedfromwindandrain,becausewindandrainmayputouttheflame;Moreover,the
appliancemightgetfrozenanddamagedinacoldwinterseason.
4. Awatersupplywithaminimum0.02Mpawaterpressureisrequiredontheinstallationsiteto
ensurethenormaloperationofthewaterheater.
5. Werecommendacoldwatervalvebeinstalledclosetothewaterheaterformaintenance
convenience.SeeFig4.
6. Keepaminimumspacefromthewallorceilingontheinstallationsite.Keepclearofstove,
combustibleanddangerousobjects.SeeFig3.
13
15
14 16
(Fig.4)
7. Ifit’spossible,installthewaterheaterattheproperheightforeasyinspectionofburning,about
1.5m.
8. Makesureapropergaspipeareinstalledandmakesurethatthepiperemainsairtightandtheinlet
gaspressureis30mbar,2h/kgfornormaloperationoftheappliance.Ifusingapipedgassupply,
askthegassupplierorthegasadministrationauthorityforpipeconnecting.
9. See“OTHERIMPORTANTCAUTIONS”forotherregulations.
(Fig.3)
4
13 15 14
17
13.Gasinlet
14.Waterinlet(cold)
15.Wateroutlet(warm)
16.Watervalve
17.Airhole

INSTALLATION(PERMANENTWALLMOUNT)
Hangingandinstallingthewaterheater(forreferenceonly)
Marktheholesonthewall,thepositionissubjecttotheactualmodelofyourwaterheater,drill4holesof
8mm,putintheplasticdowelsifneeded.
1. Hangthewaterheater,tightenthescrews.
L
OADINGTHE
B
ATTERY
Thebatteryboxislocatedunderthewaterheater.Loadthebatteriesinthefollowingorder:SeeFig.1
1Openthecoverofthebatterybox.
2Loadtwo1.5Vbatteries(Dsize)intothebatterybox,makesureoftheproperpolarity.
Improperpolaritywillaffecttheperformanceofthewaterheater.
3Closethecoveronthebatterybox.
INSTALLATIONOFGASPIPE
HosemustbedesignedforLPGgasandamaximumof1.2mlongand10
mminternaldiameter.Oraccordingtoothernationalstandard.
Attachmentofthehosemustbesecuredwithahoseclampatbothends.
Usetheincludedcouplingwithgasketsothatthegasketsitsagainstthe
gasinletontheheater.Ifusingapipedgassupply,askthegassupplierto
connectthepipe.
Usepressurereducer30mbar,2kg/h(notincluded)
E
XAMPLE
:

INSTALLATIONOFHOTANDCOLDWATERPIPE
Usehosesthatcanwithstandpressuretoconnectincomingandoutgoingwaterconnection.Notethatthe
outgoingpipealsomustwithstandtemperaturesupto70°C
USERINSTRUCTIONS
BEFORESTARTIGNITION
Pleasechecktomakesurethatthegastypeisinaccordancewiththeonestipulatedonthenameplate(see
page2).Beforeigniting,openthecoldwatervalve.Openthemastergasswitchandcheckthatthereisno
leakage(seefurtherinstructionsonpage7).
STARTIGNITION,WATERCOMESOUT
Startignition:Openthecoldwatervalve,(orstartthepump)theburnerstartstoignitewithacontinuous
“pa”sound,whichstopafterburningstarts;hotwatercomesoutimmediatelyNote:Whenusingthis
applianceforthefirsttime,orafteralongperiodbetweenuses,repeatignitionisneededtodischargeany
existingairinthegaspipe.Usetheknob“Gas”,“Water”and“Power”toadjustthewatertemperature.
With“Gas”and“Power”settotheMaxpositiongivesthemaximumpower.Theknob"Water"adjustthe
waterflowsothattheMaxpositiongivesgreaterwaterflowandthuslowertemperatureoutfromthe
heaterandviceversa.
Foratemporarystopduringuse,closethehotwatervalveorstopthepump.Theburnerwillstopburning
automatically.Openthevalveorstartthepumpforhotwateragain.
Note:Becausethewaterwillgetveryhotduringatemporarystop,waitforafewsecondsbeforecoming
intocontactwiththewater
STOPPINGTHEHEATER(WATERSTOPSCOMINGOUT)
Tostopthewaterheaterafteruse,closethehotwatervalveorstopthepump,theflameoftheburnerwill
gooutautomatically,andthewaterheaterstopsworking.
Closethecoldwatervalveorpump.Closethemastergasvalve.

THEGASPIPEMAYBECOMECRACKEDANDLEAKGASDUETOLONGTIMEUSE.INSPECTIT
REGULARLY.
(Fig.6)
Checktheconnectionsofthegaspiperegularlywithsoapywater(Fig.6)tomakesurethereisnogas
leakage.Incaseofgasleakage,nevermakefireortouchanyelectric‐switchesfortheventilationfan,etc.
Donotconnectordisconnectanypowerplugs;otherwise,aflameorsparkcouldignitethegas,causinga
fireorexplosion.Closethemastergasvalve,openallthedoorsandwindowstoexhaustthegasoutsidethe
house.Stopusingthewaterheaterandcontactaservicedepartmentorthegassupplier.
INCASEOFGASLEAKAGE,NEVERMAKEAFIREORTOUCHANYELECTRICSWITCHES,NOTMAKE
TELEPHONECALLINTHEROOM,OPENALLDOORSANDWINDOWS
Regularlycheckthepipetomakesureofgoodairtightness.Ifcracked,replacethepipeatonce.Under
normalconditions,thegaspipeneedstobecheckedonceayear.
Ifthegaspipeiscracked,stopusingitandreplaceit.ForusersofPropane:iftheflameofthewater
heaterisinconsistent,itmaybeduetoamalfunctionofthegaspressurereducer,Stopusingthe
pressurereducerandreplaceit,orgetitrepairedandinstalledbyaprofessionaltechnician.
Forusersofpipedgasornaturalgas:iftheflameisabnormal,itisduetoanunstablegaspressure.
Stopusingthewaterheatertemporarily.
Continuedusewilldamagethewaterheaterandpossiblycauseanaccident.

PREVENTFIRE
Itisabsolutelyforbiddentoleavetheburningwaterheaterunattended.Thewaterheatermustbestopped
beforegoingtobedorgoingout.
Itisforbiddentoputcombustibleorexplosiveobjectsclosetothewaterheater.Neverputatowelor
clothesontheexhaustvent.Agasleakagefromthegaspipecaneasilycausesafire.
19
13 1
18
4
20
(Fig.7)
PREVENTOXYGENDEPLETIONANDINCOMPLETEBURNING
•Becausealargequantityofoxygenisusedduringburning,theinstallationsiteforthewater
heatermustbewell.Duringoperation,thewaterheaterwillgiveofffumes;therefore,a
chimneymustbeinstalledtothewaterheatertoextractthefumesoutsidethehouseandkeep
freshairinthehouse,toensurecompleteburning.
•Wheninusewithnaturalgas:incaseoflowgaspressure,itishighlypossiblethata“flame‐
retrace”willbecreated.Thiscancauseacarbonbuild‐upintheburner.Shouldthisoccur,the
blueflamebecomesyellowandthelevelofcarbonmonoxidenotablyrises.Insuchacase,stop
usingtheheaterandcontactthegassupplier.
PREVENTBURNSONEYES
•Uponignition,neverlookattheflamewitheyesclosetotheinspectionhole.Keepyoureyesa
minimumof300mmfromtheinspectionhole.Wait10‐20secondsbeforerepeatingignition.
OTHERIMPORTANTCAUTIONS
•PREVENTBURNSFROMHOTTEMPERATURES:ifthereisaneedtousehotwatershortlyafterthehot
watervalveisclosed,donotcomeintocontactwiththefirst‐hotwatercoming,asitcould
causeburnsduetoatemporaryhightemperature.
1. Airintake
4.Smokedischargejoint
13.Gasinlet
18.Ventilationhatch
19.Hotwater
20.Airextraction

•PREVENTTHEHEATERFROMFREEZING:Inverycoldareas(withtemperaturesbelow0),please
removethedrainingstopperafterusetoreleaseaccesswater.It’salsorecommendedto
disconnecttheheaterandmoveittoastorageplacewithoutriskforfreezing.
•Somepartsofthewaterheatermaybecomeloosedueduringtransportation.Incaseof
damagestotheexternalhousingafteropeningthepackage,getarepairmantocheckbefore
use.
REPLACETHEBATTERIES.
•Replacethebatteriesifyouseethefollowingsituationsuponignitionorasthewatercomes
out.
•Longerintervalofsoundsof“Pa,Pa”duringignition(approx.2soundsasecond)
•Theflamegoesoutshortlyafterignition.
HOWTOREPLACETHEBATTERIES:SEEPARAGRAPH“LOADINGTHEBATTERY”FORDETAIL
•Pleaseusemoistureproofbatterieswithasealedmetalshell.Undernormalconditions,the
batteriesneedreplacingonceayear.
ABNORMALHANDLE
•Incaseofabnormalburning(flame‐retraceseparatedflame,yellowflameordarksmokeetc.)
unexpectedsmell,noiseoremergency(earthquakeorfire),remaincalmtoclosethewater
heatertostopburning,closethegasvalveafterwardsandcontacttheservicedepartmentor
thegassupplier.
MAINTENANCE&SERVICES
•Thewaterheaterneedscleaningperiodically(generallyonceeveryhalfyear)toensureits
normalperformance.Checktheflamefrequently,incaseofayellowflamewithdarksmoke,
informtheservicedepartmentforcleaning.Tocleantheexternalhousing,pleasegentlymopit
withawetclothfollowedwithadrycloth.Ifthewaterheaterremainsunusedforalongtime,
coverthetoptopreventdust.Neverusechemicaldetergentsforcleaning;otherwise,the
externalhousingwouldbecomefadedandloseitsgloss.Allabnormalitiesmustonlybe
handledbyqualifiedpersonnel.
•Note:Theroominstalledwiththewaterheatermusthaveafixedopenair‐inductionopening.
Closedwindowsareineffective.

TROUBLE&TROUBLESHOOTING
Troubles
Causes
Flamegoesoutduringuse
Openwatervalve,noflame
Explosion‐likeburningupon
igniting
Yellowflamewithdarksmoke
Abnormalflamewith
unexpectedsmell
Abnormalnoisefromburning
Nohotwateralthoughsetfor
largeflame
Nohotwaterwhensetforlow
temperature
Flamegoesoutwhensetfor
low
Remainsburningafter
cold/hotwatervalveisclosed
Troubleshooting
Themastergas
valveremains
closed,orgas
usedup
••
Openthemastergas
valveorreplace
thegasbottle
Malfunctionof
pressure
adjuster
••• ••
Openthemastergas
valveorreplace
thegasbottle
Remainingairin
thegaspipe• Repeatoperatingto
open/closehot
watervalveuntil
burning.(note:
remembertokeepan
intervalof
minimum5seconds
between)every
openandclose),geta
repairmanto
repairthepressure
adjuster.
Abnormal
inletgas
pressure
High
••••
Low
•• •
•
Coldwatervalve
remains
closed
•
Fullyopenthewaterinlet
valve
Blockinthefilter
net•• •Cleanthefilternet
Frozen Getunfrozenbeforeuse
Lowcoldwater
pressure•• •Checkthewaterpressure
Incorrectwayto
adjustwater
temperature
••
Adjusttemperatureknob
andwater
knob
Lackoffreshair
supply• ••
Improveairventilationto
supply
enoughfreshair
Actionofsecurity
device••
Restartwaterheater,ifit
failstoworksenditto
theservicedepartment
forrepair
Powerless
batteries•• Replacethebattery
Blockinthe
burner•••••
Contacttheservice
department
Blockinthe
heatingcoil ••• •
Malfunctionof
thethermalpin••• •
Malfunctionof
thewatercontrol
unit
•
•
Malfunctionof
theon/offswitch• •
Table of contents
Other SpaDealers Water Heater manuals
Popular Water Heater manuals by other brands

Noritz
Noritz proTough NR98SV installation manual

EHC
EHC NEPTUNE NINDSL90L Installation & maintenance instructions

AquaStar
AquaStar 125B LP Installation and operating instructions

Energie
Energie ECO-NOMIC Technical manual

gledhill
gledhill PLATINUM D120 instruction manual

Rinnai
Rinnai HOTFLO EHFA Series installation manual

Morco
Morco F-11E Installation and user manual

clage
clage CDX 7-U Operating instructions for the user

Ariston
Ariston LGO30L manual

Bradford White
Bradford White EVERHOT IGI-180R Series Installation and operating instruction manual

Kenmore
Kenmore 153.313340 owner's manual

Bradford White
Bradford White EFR-1-60T1206EN Installation & operating manual