INS_SEF-U_0111
Preventive maintenance
Do not try to repair your furnace yourself. Call a qualified technician. However, before calling a technician, check the following points.
1) Make sure fuses or circuit breakers are activated.
3) Adjust the temperature set point of the thermostat above the ambient temperature. If heating does not start, cut off the power supply and call a techni-
cian.
N.B. When calling a technician for maintenance or to order a replacement part, specify the model of your furnace as well as its serial number.
Air filter
Excessive dust or dirt accumulation can block the airflow, forcing the unit to work harder to maintain the desired temperature. Therefore, it uses more energy and
increases heating costs.
Since the air filter supplied is disposable, you should replace it two to four times a year, according to the model used and the installation area. Dirtier areas can
require more than four filter changes.
To replace a dirty filter, open the access door to the filter, remove the old filter and insert the new one inside the rack. Make sure the new filter has the same techni-
cal specifications and size as the previous one.
N.B. Never operate the unit without a filter in place.
Every time a filter is changed, you should check the following points.
- Excessive accumulation of dirt or dust on furnace components.
- Damaged components or surfaces.
- Presence of water inside or outside the furnace.
If you encounter any of these problems, do not operate the furnace. Call a qualified technician.
Blower
The blower motor is sealed and permanently lubricated, so it is not necessary to lubricate it.
Even if you change the filter frequently, the blower’s blades and motors will become dust laden after a few months. The entire blower assembly should be inspect-
ed annually. If needed, vacuum out the dust. If you cannot clean the blower without removing it from the furnace, this service must be performed by a qualified
technician.
TROUBLESHOOTING
If you encounter a problem, check the following table before calling a technician. Should modification or servicing be required, make sure the technician uses only
factory authorized parts, accessories, or kits for this furnace.
PROBLEM DEFECTIVE PART OR PART TO CHECK
The unit does not work - Defective thermostat or wrong thermostat setting or location
- Open circuit breaker or fuse
The unit runs continuously - Blower control switch is on the continuous position
The on/off cycles of the motor are too short or too long - The heat anticipator is incorrectly set or is burned out (if applicable)
Overheating - Defective thermostat or wrong thermostat setting or location
- Defective motor
The thermostat must be set at a much higher or lower temperature than the
desired ambient temperature -The thermostat is not levelled, needs calibration or is installed in an improper loca-
tion
The desired room temperature cannot be reached - The thermal protections opens the circuit because of duct obstructions or dirty
filters
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer
service (see the “Limited warranty” section to obtain the phone numbers).
REPLACEMENT COMPONENT LIST
#REF. #PART DESCRIPTION
1 ELF-SEF0521 ELEMENT ASSEMBLY 5 kW
1 ELF-SEF0421 ELEMENT ASSEMBLY 4 kW
1 ELF-SEF0321 ELEMENT ASSEMBLY 3.5 kW
1 ELF-SEF0221 ELEMENT ASSEMBLY 2 x 2.5 kW
2 BLO-004 SQUIRREL CAGE & BLOWER 10-8 FOR 10 TO 23 KW.
2 BLO-005 SQUIRREL CAGE & BLOWER 12-11 FOR 27 & 30 KW.
3 MO-037 MOTOR 1HP, 208/240V, 1075 RPM, 3 ADD. SPEEDS INCLUDED.
3 MO-036-1 MOTOR 1/3HP, 208/240V, 1075 RPM, 4 AD. SPEEDS INCLUDED
4 PROT-010 THERMAL PROTECTION L-160-40 - 10 kW TO 23 kW
4 PROT-019 THERMAL PROTECTION L-140-40 - 27 kW & 30 kW
5 SWI-004 SPDT SWITCH WITHOUT MARKINGS 16 A, 250 V, 3/4 HP, 250 V, T85
6 PL-001 GREEN PILOT LIGHT 28 V, 04 A
6 PL-002 GREEN PILOT LIGHT 250 V, 1/3 W
7 TRF200050D TRANSFO 240-208/24/50VA (SEC.10.5 &13)
8 REL-004 RELAY 24 V, FORM X, 18 A RES.
8 REL-005 RELAY 240 V, FORM X, 18 A RES.
8 REL-003 RELAY 24 V, FORM C, 20 A NO, 10 A NC
9 SEQ-005 DOUBLE SEQUENCER 24 V, H1-20 C40-90, H30-90 C1-30
9 SEQ-003 SINGLE SEQUENCER 24 V, H30-90 C1-30
9 SEQ.-007 DOUBLE SEQUENCER 24 V, H40-100 C1-30, H25-60 C25-45
10 CAP-002 CAPACITOR 20 UF POUR 1 HP À 240 V WITH SUPPORT
10 CAP-010 CAPACITOR 6 UF POUR 1/3 HP À 240 V WITH SUPPORT