Sunlover SL8SA User manual

SL8SA- INSTRUCTIONS
Page 1 of 4
CONTROLLER MOUNTING:
The controller enclosure must be f rmly attached to a nearby sol d f xture by e ther the two mount ng lugs or d rect
attachment though the controller. If mount ng through the controller ensure the power cord s d sconnected from the
ma ns supply then remove the enclosure front cover by turn ng the four corner locks so each arrow po nts to the ‘O’
marked on the front cover. Insert two mount ng screws d agonally through the oval holes n the enclosure, ref t front
cover and turn the four corner locks to the ‘I’ pos t on.
The power cable s 1.8m long and should be plugged d rectly nto a general power outlet, not nto an extens on lead.
CIRCULATING PUMP:
The solar c rculat ng pump plugs nto the r ght hand 240Vac socket marked as SOLAR PUMP. The left hand 240Vac
socket marked as AUXILIARY suppl es 240Vac at all t mes. The max mum comb ned current s 10 AMPS 2400W.
TEMPERATURE SENSORS:
The solar pool sensor must be f tted nto the suct on l ne of the solar boost pump, preferably n a pos t on out of d rect
sunl ght. The aux pool sensor must be f tted nto the suct on l ne before the pool pump (f ltrat on pump). It s
recommended that a 14.5mm hole be dr lled n the PVC p pe, th s can be carr ed out us ng a Dontek PD01 gr nd ng dr ll
or a small p lot hole can be dr lled and a 14.0mm dr ll-b t used sp nn ng n a counter clockw se d rect on to m n m ze the
chance of shatter ng p pe. Insert the grommet nto the p pe and gently push n the black sensor barb. The green solar
pool sensor plug s to be f tted to the plug socket marked POOL. The aux pool sensor plugs nto the socket marked
RELAY1 (Black to NO, Wh te str pe to C).
Roof sensor must be f tted nto a small p ece of rubber collector mater al away from the ma n collector but on the same
aspect. Keep n m nd that t s of the utmost mportance to keep the roof sensor cable as short as poss ble as th s w ll
ass st n the longev ty of the sensor and controller n the event of electr cal storm act v ty and power surges. Sensor
cables must not be run parallel to power cables and run lengths should be less than 50m. Cable t es should be used to
fasten the sensor cable to the cold water nlet p pe mak ng sure that the t es are approx mately 10mm from PVC
f tt ngs. Cable t es should be t ghtened only f rm, over t ghten ng can cause breaks n the outer PVC f not careful. If the
cable s to be run under ground a condu t must be used to protect the w re and there s to be no cable jo ns w th n,
condu t ends must be sealed to prevent water ngress. Any excess cable should be removed and re-fitted ensuring that
the wire ends are tinned with solder. The sensor plug s to be f tted to the r ght hand socket marked ROOF.
FLOW SWITCH:
The flow sw tch must be f tted after the pool/spa valve nto the pool return l ne, the arrow on the flow sw tch nd cates
the d rect on of water flow. The green plug w ll go nto the FLOW socket on the controller.
HEATER INTERLOCK:
The heater nterlock cable connects n-ser es to the ex st ng nternal flow or pressure sw tch ns de the heater,
connect on var es depend ng on model, contact heater manufacturer for deta ls, max mum sw tch ng capab l ty of the
controller s 5 AMP at 32VAC MAX! If the heater exceeds th s then the 240V sw tch ng opt on s to be f tted.
The green plug on the heater nterlock cable connects to the socket marked RELAY2 (NO/C).
OPTION - IHP:
An opt onal IHP connects to the DATA socket of the controller; ensure to match the colours to avo d damage. Do not
run near 240Vac w r ng.
DESCRIPTION:
The Solar s for heat ng the pool only and w ll operate as a standalone system. If water flow s detected by the flow
sw tch then the aux pool temperature sensor s used; and f there s no solar ga n the aux heater w ll be enabled f
w th n the selected t meframe of heat demand and only f the pool temperature s below the aux l m t sett ng.
If there s solar ga n ava lable then the heater w ll run n conjunct on w th the solar but w ll turn off when the roof
temperature exceeds 15°C above the solar temperature l m t sett ng. When the flow sw tch detects that water flow has
stopped go ng nto the pool then the heater s enabled to heat the spa to the h gher temperature l m t as set at the aux
heater.
SOFTWARE SETTINGS:
To enter the SETTINGS MENU push e ther the Up or Down buttons and the follow ng w ll be d splayed;
SETTINGS MENU
1) MANUAL MODE
Use Up or Down buttons to scroll to the opt on you w sh to change. Press the Enter button to select the currently
d splayed menu tem.
All menu tems are shown below;
SETTINGS MENU
1) MANUAL MODE
2) TEMPERATURES
3) AUX. HEATER
4) MODE
5) SYSTEM SETUP
6) SAVE & EXIT

SL8SA- INSTRUCTIONS
Page 2 of 4
1) MANUAL MODE
MANUAL PUMP MODE
UP=ON DOWN=OFF
MANUAL MODE allows you to manually set the solar pump to ‘on’ by press ng the Up button or ‘off’ by press ng the
Down button. In manual mode the heater s sw tched off.
Press ng Enter w ll return you to the SETTINGS MENU. You can also keep press ng Enter to toggle the pump from ‘on’
to ‘off’ and v ce versa.
MANUAL MODE w ll t meout, after 24 hours the un t w ll return to automat c operat on.
2) TEMPERATURE
TEMPERATURE
SOL LIMIT XX.X
When you enter the TEMPERATURE menu you may change the des red temperature of the pool for solar heat ng.
Change the des red temperature l m t by press ng the Up or Down buttons, f no change s requ red s mply push Enter.
Heat ng w ll stop and sample wa t ng beg ns once the des red temperature l m t s reached.
Note that solar heat ng can only occur f solar ga n s ava lable. (SOLAR GAIN = YES)
If the AUX. HEATER s set to ON then the follow ng w ll also be d splayed;
TEMPERATURE
AUX LIMIT XX.X
You may change the des red temperature of the pool for aux l ary heat ng ( n pool mode).
Change the des red temperature l m t by press ng the Up or Down buttons, f no change s requ red s mply push Enter.
Heat ng w ll stop once the des red temperature l m t s reached.
For max mum eff c ency t s adv sable that the solar l m t (SOL LIMIT) be set sl ghtly h gher than the aux l ary l m t.
**Factory default for AUX LIMIT s 27°C and SOL LIMIT s 30°C.
3) AUX. HEATER
AUX. HEATER
ON/OFF
When you enter the AUX. HEATER menu you w ll need to select ON or OFF, the selected opt on w ll be flash ng, you can
use Up/Down to change the selected opt on, Enter to accept. Th s controls when the Aux Heater s allowed to operate.
If OFF s selected you w ll return to the menu, If ON s selected you w ll be prompted for START and END t me, mod fy
values by us ng the Up/Down buttons, use Enter to accept the values.
HEAT DEMAND TIME HEAT DEMAND TIME
START TIME X:XX END TIME X:XX
If a 24 hour run t me s requ red then set the start and end t me to the same value. (e.g. Start 12:00, End 12:00)
Note 1: when SOLAR GAIN =HIGH s shown then the heater w ll stop as pr or ty s g ven to low cost solar heat ng.
Note 2: H gh solar ga n s def ned as 15°C above the SOL LIMIT sett ng.
**Factory default for HEAT DEMAND s ON (06:00 to 22:00)
4) MODE
MODE
SUMMER MODE/WINTER MODE/TROPICAL MODE
You can use Up/Down to change the selected opt on, Enter to accept.
SUMMER MODE s the normal operat on of heat ng the sw mm ng pool.
TROPICAL MODE s selected f you w sh to cool the sw mm ng pool, the solar pump w ll run f the roof temperature s
colder than the pool unt l solar temperature l m t s ach eved; note that th s s most l kely to occur at n ght.
WINTER MODE, when selected you w ll be prompted to select the start month and end month of w nter ( nclus ve, also
note that the start Month must be of lower value then the end Month.), th s ass sts n the systems off-season
ma ntenance and save energy as solar ga n may be ava lable but sw mm ng temperature cannot be ach eved. Every day
a 3 m nute flush of the solar matt ng occurs between 10:00 and 16:00 prov d ng the roof temperature s equal or
greater than the pool, but f that cond t on does not occur a solar system flush w ll be forced to occur at 16:00.
**Factory default for MODE s SUMMER

SL8SA- INSTRUCTIONS
Page 3 of 4
5) SYSTEM SETUP
Four opt ons are ava lable under system setup;
SET SYSTEM CLOCK / FACTORY SETTINGS / SOLAR PARAMETERS / EXIT.
EXIT - w ll return you to 5) SYSTEM SETUP w th no changes.
SET SYSTEM CLOCK – allows you to adjust calendar and t me of day.
FACTORY SETTINGS – restores all the sett ngs to the factory default state.
SOLAR PARAMETERS – for sett ng the solar start and end t mes.
Solar parameters;
SOLAR START TIME SOLAR END TIME
HOUR (24H) XX HOUR (24H) XX
The start t me s the t me of day ‘hour’ that the solar pump s allowed to start. The solar end t me s the t me of day
‘hour’ at wh ch the pump w ll stop.
**Default t me the solar pump s allowed to operate s from 08:00 to 19:00.
Adjust values by press ng the Up/Down buttons, to accept the sett ng press the Enter button.
) SAVE & EXIT
When th s menu s selected, push Enter to save ALL sett ngs, the un t w ll return to normal operat on automat cally.
Note: If any of the menu tems are left unattended for 3-4 m ns the menu w ll t me out and automat cally save all
sett ngs and return to operat on.
The ENTER/MANUAL button
FOR MANUAL MODE
PRESS ENTER NOW
Press ng the Enter button once w ll d splay the above message for ~3 seconds, s mply wa t and the un t w ll return to
normal operat on. (th s can also be used to bypass the 3 m nute m n mum run t me).
If you Enter s pressed for a second t me w th n a 3 second per od, the d splay w ll nd cate you have entered Manual
mode, operat on s the same as manual mode n the menu w th the only d fference be ng the t meout value s 4 Hours.
NOTES.
1. If a sensor fault s detected the V7 w ll d splay wh ch sensor and what the fault s.
2. Should power be nterrupted for any reason, the V7 w ll resume normal operat on when power s restored, all
nformat on w ll have been kept.
3. Temperature sensors used w th th s un t are D g tal and are accurate to 0.5 Deg. C, no cal brat on s requ red.
4. The sensor cable w th the th n trace s the pos t ve and s usually f tted to the r ght hand s de of the green plug,
ncorrect polar ty w ll be d splayed.
5. The heater nterlock sw tch ng s used the max mum load s 5A at 32Vac max.

SL8SA- INSTRUCTIONS
Page 4 of 4
WARRANTY
This product is covered by a limited 3 year warranty against component failure or
faulty workmanship from the date of installation.
A faulty unit should be returned in the first instance to the dealer from which the unit
was purchased.
Damage to the unit due to misuse, power surges, lightning strikes or installation that is
not in accordance with the manufacturer’s instruction may void the warranty.
Warranty does not cover travel costs to or from installation site. nit must be returned
to manufacturer for repairs.
If the power cord is damaged, do not use the controller; return the unit to the supplier
for repair.
Customer Record. (To be retained by the customer);
Dealer/Installer Name ___________________________
Serial Number ___________________________
Date Installed ___________________________
For service assistance phone S NLOVER HEATING
VIC 03 9887 2131
NSW 02 9838 0000
QLD 07 5597 7360
Factory 6
62 Parkhurst Drive, 7-9 Activity Crescent,
Knoxfield 3153 Molendinar 4214
Victoria Australia Queensland Australia
nit 2
20-22 Foundry Road,
Seven Hills 2147
NSW Australia
www.sunloverheating.com.au
Table of contents
Popular Enclosure manuals by other brands

Memphis
Memphis POLARIS RANGER quick start guide

StarTech.com
StarTech.com S251BU31C3CB quick start guide

AMX
AMX Rough-In Box CB-TP17 installation guide

LifeSafety Power
LifeSafety Power Flexpower RBE installation manual

Thermaltake
Thermaltake Vi-ON ST0008U user manual

Lian-Li
Lian-Li O11 DYNAMIC XL installation guide