Technovision 421VS User manual

Technovision Interactive
421VS
Operating Guide
Revision 2017-11
TECHNOVISION INTERACTIVE INC
www.technovision.com
Page 2Technovision 421VS Operating Guide
Technovision 421VS Operating Guide Page 3
Table of Contents
421VS SYSTEM OVERVIEW.....................................................................4
TTL CONTROL (2 AND 4 LINE MODE)..................................................4
2-LINE TTL CONTROL..............................................................................5
4-LINE CONTROL (DRY CONTACT CLOSURE)..................................5
RS232 CONTROL (9600,8,N,1)....................................................................6
DETERMINING THE SWITCHER ADDRESS:......................................................6
TECHNICAL SPECIFICATIONS..............................................................7
FUNCTION SWITCH SETTINGS ON MAIN BOARD (DS1).................7
421VS POWER REQUIREMENTS: ..........................................................7
CSYNC OUTPUT:......................................................................................7
CONTROL PORT CONFIGURATION (DB9 MALE): ...............................7
AVAILABLE OPTIONS...............................................................................7
Page 4Technovision 421VS Operating Guide
421VS SYSTEM OVERVIEW
The Technovision PC-2 is a 4 to 1 vertical interval (audio follow video)
switcher capable of being controlled various ways, using the external
CONTROL connector on the back:
The different modes of control are:
•2-line TTL control (DEFAULT)
•4-line TTL (dry contact closure) control
•RS232 control
CAUTION
Please make sure the power supply to the 421VS is unplugged before
attaching cables. Static discharge into the 421VS through any of its
connectors may damage the switcher.
**NOTE**
VIDEO INPUT#1 MUST BE CONNECTED –THIS INPUT IS USED
TO GENERATE THE VERTICAL SYNCH PULSE.
TTL CONTROL MODES: (2 and 4 line mode)
•The default setting for the switcher is 2-line TTL controls (DIP switch
positions 1 and 2 OFF).
•INPUT CONTROL lines are pulled high internally by the switcher. To
select an input you will have to pull the appropriate input control lines on
the CONTROL connector to ground. The default video input at power-up
is 1 (all INPUT CONTROL lines high).
•In 2-line mode, the control lines must be kept low or the input will switch
back to 1.
•In 4-line mode the control line can be pulled low momentarily.
•Pin 1 is input control line 1. (Used in 2 and 4-line mode).
•Pin 6 is input control line 2. (Used in 2 and 4-line mode).
•Pin 2 is input control line 3. (Used in 4-line mode only).
•Pin 7 is input control line 4. (Used in 4-line mode only).
•Pin 5 is the ground.
Technovision 421VS Operating Guide Page 5
CONTROL MODE: 2-line TTL Control
DIP-switch position 1 and 2 must be OFF. Control lines MUST be kept low
to select the video input.
INPUT # PIN 1 on CONTROL PIN 6 on CONTROL
1HIGH (OPEN) HIGH (OPEN)
2Pulled LOW to Ground HIGH (OPEN)
3HIGH (OPEN) Pulled LOW to Ground
4Pulled LOW to Ground Pulled LOW to Ground
Example: To select INPUT #2 you must contact pin 1 to ground (pin 5).
Releasing it would return the INPUT to #1.
CONTROL MODE: 4-line TTL Control (dry contact closure)
DIP-Switch position 1 must be OFF and position 2 must be ON. Input
control lines can be pulled low (dry contact closure with pin 5) momentarily
to select the input.
INPUT # PIN 1 PIN 6 PIN 2 PIN 7
1PULLED
LOW HIGH
(OPEN) HIGH
(OPEN) HIGH
(OPEN)
2HIGH
(OPEN) PULLED
LOW HIGH
(OPEN) HIGH
(OPEN)
3HIGH
(OPEN) HIGH
(OPEN) PULLED
LOW HIGH
(OPEN)
4HIGH
(OPEN) HIGH
(OPEN) HIGH
(OPEN) PULLED
LOW
Example: To select INPUT2 you can momentarily contact pin 6 to ground
(pin 5).
Page 6Technovision 421VS Operating Guide
CONTROL MODE: RS232 Control (9600, 8, N, 1)
•You will have to remove the lid on the 421VS and move Function switch
position 1 to the ON position for RS232 control.
•The protocol is 9600 baud, no parity, 8 bits, 1 stop.
•The switcher receives data on pin 3 and transmits on pin 8 of the DB9
male connector on the back of the switcher. Data ground is pin 5.
•On start-up the switcher will transmit "Technovision 421VS".
•A single byte is sent to the switcher to select the input signal. This byte is
echoed back by the switcher upon receipt of the command.
The protocol of the single byte command to the switcher is as follows:
•Bits 7 to 4 are always ∅∅11 (30H)
•Bits 3 and 2 are the switcher address (0 to 3). Default is ∅∅
•Bits 1 and 0 are the input select value (I). Value of ∅=input 1, 1=input 2,
2=input 3 and the value of 3=input 4.
Example for a switcher with the address of ∅∅ (DEFAULT):
Input # RS232 character to transmit to the switcher (address 0)
130H (30H+address∅∅ + ∅), ASCII "∅" , decimal 48
232H (30H+address∅∅ + 1), ASCII "1" , decimal 49
332H (30H+address∅∅ + 2), ASCII "2" , decimal 50
433H (30H+address∅∅ + 2), ASCII "3" , decimal 51
Determining the switcher address:
Address Value to add
00
14
28
312
Example: To select INPUT#3 on the 421VS with the address of 0 (default),
you would transmit (30H+0+3) -the character “3” to the 421VS.
Example: To select INPUT#3 on the 421VS with the address of 1, you would
transmit (30H+4+3) -the character “7” to the 421VS.
Technovision 421VS Operating Guide Page 7
TECHNICAL SPECIFICATIONS
FUNCTION SWITCH SETTINGS ON MAIN BOARD (DS1)
SWITCH
POSITION #
Function
ON OFF
(Default)
1Control Mode RS232 TTL
24 / 2 line select 4-line 2-line TTL
3Value of bit 1 of
switcher address Switcher Address
bit 1 = 1 Address
bit 1 = 0
4Value of bit 0 of
switcher address Switcher Address
bit 0 = 1 Address
bit 0 = 0
421VS POWER REQUIREMENTS:
16 VDC, 200ma, 2.1 mm connector, and center positive.
CSYNC OUTPUT:
An RCA connector provides the composite sync signal. This signal along with
the vertical switch timing is derived from the video signal on INPUT 1.
CONTROL PORT CONFIGURATION (DB9 male):
Pin# Description Pin# Description
1Input control line 1 6Input control line 2
2Input control line 3 7Input control line 4
3RS232 Receive data RX
(INPUT) 8RS232 Transmit data TX
(OUTPUT)
4Secondary RX 9Secondary TX
5GROUND
AVAILABLE OPTIONS
Part # Description
421RACK 19" EIA RACK MOUNT KIT
Page 8Technovision 421VS Operating Guide

Popular Switch manuals by other brands

Califone 1117 user manual

Califone

Califone 1117 user manual

ADDER ADDERView Secure AVS-4224 quick start

ADDER

ADDER ADDERView Secure AVS-4224 quick start

Targus ACH76US quick start guide

Targus

Targus ACH76US quick start guide

Sonoff BASICR3 Operating	 instruction

Sonoff

Sonoff BASICR3 Operating instruction

Comm IPC-6+ user guide

Comm

Comm IPC-6+ user guide

D-Link xStack DGS-3620 Series reference guide

D-Link

D-Link xStack DGS-3620 Series reference guide

Manhattan 561532 instructions

Manhattan

Manhattan 561532 instructions

Orro Multiway installation guide

Orro

Orro Multiway installation guide

Allied Telesis x900-48FE Hardware reference

Allied Telesis

Allied Telesis x900-48FE Hardware reference

Gefen Digital Audio Switcher user manual

Gefen

Gefen Digital Audio Switcher user manual

Accom ASWR8150 Technical manual

Accom

Accom ASWR8150 Technical manual

HP AF618A specification

HP

HP AF618A specification

Graco 558938 instructions

Graco

Graco 558938 instructions

INSTEON Starter Kit quick start guide

INSTEON

INSTEON Starter Kit quick start guide

Tech Universe 7 Port USB Hub user manual

Tech Universe

Tech Universe 7 Port USB Hub user manual

LevelOne FGS-2800 Quick installation guide

LevelOne

LevelOne FGS-2800 Quick installation guide

Lindy 42340 user manual

Lindy

Lindy 42340 user manual

IBM Brocade FCoE Installation and user guide

IBM

IBM Brocade FCoE Installation and user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.