Technovision 421VS User manual

Technovision Interactive
421VS
Operating Guide
Revision 2017-11
TECHNOVISION INTERACTIVE INC
www.technovision.com
Page 2Technovision 421VS Operating Guide

Technovision 421VS Operating Guide Page 3
Table of Contents
421VS SYSTEM OVERVIEW.....................................................................4
TTL CONTROL (2 AND 4 LINE MODE)..................................................4
2-LINE TTL CONTROL..............................................................................5
4-LINE CONTROL (DRY CONTACT CLOSURE)..................................5
RS232 CONTROL (9600,8,N,1)....................................................................6
DETERMINING THE SWITCHER ADDRESS:......................................................6
TECHNICAL SPECIFICATIONS..............................................................7
FUNCTION SWITCH SETTINGS ON MAIN BOARD (DS1).................7
421VS POWER REQUIREMENTS: ..........................................................7
CSYNC OUTPUT:......................................................................................7
CONTROL PORT CONFIGURATION (DB9 MALE): ...............................7
AVAILABLE OPTIONS...............................................................................7
Page 4Technovision 421VS Operating Guide
421VS SYSTEM OVERVIEW
The Technovision PC-2 is a 4 to 1 vertical interval (audio follow video)
switcher capable of being controlled various ways, using the external
CONTROL connector on the back:
The different modes of control are:
•2-line TTL control (DEFAULT)
•4-line TTL (dry contact closure) control
•RS232 control
CAUTION
Please make sure the power supply to the 421VS is unplugged before
attaching cables. Static discharge into the 421VS through any of its
connectors may damage the switcher.
**NOTE**
VIDEO INPUT#1 MUST BE CONNECTED –THIS INPUT IS USED
TO GENERATE THE VERTICAL SYNCH PULSE.
TTL CONTROL MODES: (2 and 4 line mode)
•The default setting for the switcher is 2-line TTL controls (DIP switch
positions 1 and 2 OFF).
•INPUT CONTROL lines are pulled high internally by the switcher. To
select an input you will have to pull the appropriate input control lines on
the CONTROL connector to ground. The default video input at power-up
is 1 (all INPUT CONTROL lines high).
•In 2-line mode, the control lines must be kept low or the input will switch
back to 1.
•In 4-line mode the control line can be pulled low momentarily.
•Pin 1 is input control line 1. (Used in 2 and 4-line mode).
•Pin 6 is input control line 2. (Used in 2 and 4-line mode).
•Pin 2 is input control line 3. (Used in 4-line mode only).
•Pin 7 is input control line 4. (Used in 4-line mode only).
•Pin 5 is the ground.

Technovision 421VS Operating Guide Page 5
CONTROL MODE: 2-line TTL Control
DIP-switch position 1 and 2 must be OFF. Control lines MUST be kept low
to select the video input.
INPUT # PIN 1 on CONTROL PIN 6 on CONTROL
1HIGH (OPEN) HIGH (OPEN)
2Pulled LOW to Ground HIGH (OPEN)
3HIGH (OPEN) Pulled LOW to Ground
4Pulled LOW to Ground Pulled LOW to Ground
Example: To select INPUT #2 you must contact pin 1 to ground (pin 5).
Releasing it would return the INPUT to #1.
CONTROL MODE: 4-line TTL Control (dry contact closure)
DIP-Switch position 1 must be OFF and position 2 must be ON. Input
control lines can be pulled low (dry contact closure with pin 5) momentarily
to select the input.
INPUT # PIN 1 PIN 6 PIN 2 PIN 7
1PULLED
LOW HIGH
(OPEN) HIGH
(OPEN) HIGH
(OPEN)
2HIGH
(OPEN) PULLED
LOW HIGH
(OPEN) HIGH
(OPEN)
3HIGH
(OPEN) HIGH
(OPEN) PULLED
LOW HIGH
(OPEN)
4HIGH
(OPEN) HIGH
(OPEN) HIGH
(OPEN) PULLED
LOW
Example: To select INPUT2 you can momentarily contact pin 6 to ground
(pin 5).
Page 6Technovision 421VS Operating Guide
CONTROL MODE: RS232 Control (9600, 8, N, 1)
•You will have to remove the lid on the 421VS and move Function switch
position 1 to the ON position for RS232 control.
•The protocol is 9600 baud, no parity, 8 bits, 1 stop.
•The switcher receives data on pin 3 and transmits on pin 8 of the DB9
male connector on the back of the switcher. Data ground is pin 5.
•On start-up the switcher will transmit "Technovision 421VS".
•A single byte is sent to the switcher to select the input signal. This byte is
echoed back by the switcher upon receipt of the command.
The protocol of the single byte command to the switcher is as follows:
•Bits 7 to 4 are always ∅∅11 (30H)
•Bits 3 and 2 are the switcher address (0 to 3). Default is ∅∅
•Bits 1 and 0 are the input select value (I). Value of ∅=input 1, 1=input 2,
2=input 3 and the value of 3=input 4.
Example for a switcher with the address of ∅∅ (DEFAULT):
Input # RS232 character to transmit to the switcher (address 0)
130H (30H+address∅∅ + ∅), ASCII "∅" , decimal 48
232H (30H+address∅∅ + 1), ASCII "1" , decimal 49
332H (30H+address∅∅ + 2), ASCII "2" , decimal 50
433H (30H+address∅∅ + 2), ASCII "3" , decimal 51
Determining the switcher address:
Address Value to add
00
14
28
312
Example: To select INPUT#3 on the 421VS with the address of 0 (default),
you would transmit (30H+0+3) -the character “3” to the 421VS.
Example: To select INPUT#3 on the 421VS with the address of 1, you would
transmit (30H+4+3) -the character “7” to the 421VS.

Technovision 421VS Operating Guide Page 7
TECHNICAL SPECIFICATIONS
FUNCTION SWITCH SETTINGS ON MAIN BOARD (DS1)
SWITCH
POSITION #
Function
ON OFF
(Default)
1Control Mode RS232 TTL
24 / 2 line select 4-line 2-line TTL
3Value of bit 1 of
switcher address Switcher Address
bit 1 = 1 Address
bit 1 = 0
4Value of bit 0 of
switcher address Switcher Address
bit 0 = 1 Address
bit 0 = 0
421VS POWER REQUIREMENTS:
16 VDC, 200ma, 2.1 mm connector, and center positive.
CSYNC OUTPUT:
An RCA connector provides the composite sync signal. This signal along with
the vertical switch timing is derived from the video signal on INPUT 1.
CONTROL PORT CONFIGURATION (DB9 male):
Pin# Description Pin# Description
1Input control line 1 6Input control line 2
2Input control line 3 7Input control line 4
3RS232 Receive data RX
(INPUT) 8RS232 Transmit data TX
(OUTPUT)
4Secondary RX 9Secondary TX
5GROUND
AVAILABLE OPTIONS
Part # Description
421RACK 19" EIA RACK MOUNT KIT
Page 8Technovision 421VS Operating Guide
Popular Switch manuals by other brands

Kramer
Kramer VIA CONNECT PRO user manual

ATEN
ATEN VS-0404 quick start guide

SALZ
SALZ 2016GT Quick installation guide

Alcatel-Lucent
Alcatel-Lucent OmniSwitch 6850-48 Brochure & specs

Icy Box
Icy Box IB-HUB1410-C3 Quick installation guide

Smart Cabling & Transmission
Smart Cabling & Transmission TPP016VPD user manual