TECNARE 44TDAP Series User manual

Keep these important operatin instructions.
Check www.tecnare.com for updates
Operation Manual
44TDAP Series
Digital Amplifier Processed


General Information
44TDAP Series Operation Manual
Ver.: 1.0_UK 12/2022
©EXEL ACOUSTICS SL; all right reserved
The information contained in this manual has been carefully
checked for accuracy, at the time of going to press, however
no guarantee is given with respect to the correctness.
Exel Acoustics SL accepts no responsibility for any errors or
inaccuracies that may appear in this manual or the products
and software described in it. Technical specications, dimen-
sions, weights and properties do not represent guaranteed
qualities. As manufacturers we reserve the right to make
alterations and modications within the framework of legal
provisions, as well as changes aimed at improving quality.
EXEL ACOUSTICS SL
CL Encinar, 282 – Pol. Ind. Monte Boyal
45950 Casarrubios del Monte (Toledo) Spain
Phone: (+34) 918 170 110 Fax:

4
Operation Manual
www.tecnare.com
IMPORTANT SAFE INSTRUCTIONS
Before using our product, be sure to carefully read the manual and safe Instructions. Keep this document with the device
all time.
1. Read these instructions
2. Keep these instructions.
3. Heed all warnings.
4. Follow all SAFETY INSTRUCTIONS as well DAN-
GER and OBLIGATION warnings.
5. Only use attachments / accessories specied by Exel
Acoustics SL.
6. Do not use this apparatus near water.
7. Clean only with dry cloth.
8. Do not block any ventilation openings. Install in ac-
cordance with Exel Acoustics’ instructions.
9. Do not install near any heat sources such as radia-
tors, heat registers, stoves or other apparatus (includ-
ing ampliers) that produces heat.
10. Do not defeat the safety purpose of the polarized or
grounding type plug. A polarized plug has two blades
with one wide than the other. A grounding type plug
has two blades and a third pin are provided for your
safety. If the provided plug does not t into your out-
let, consult an electrician for replacement of the ob-
solete outlet.
11. Protect the power cord from being walked on or
pinched, particularly at plugs, convenience recepta-
cles and the point where they exit from the appara-
tus.
12. Unplug this apparatus during lightning storms or
when unused for long periods of time.
13. Refer all servicing to qualied service personnel.
Service is required when the apparatus has been
damaged in any way, such as power-supply cord or
plug damaged, liquid has been spilled or objects have
fallen into the apparatus, this apparatus has been ex-
posed to rain or moisture, does not operate normally,
or has been dropped.
14. Use the mains plug to disconnect the device from
mains.
15. Do not expose this equipment to dripping or splash-
ing and ensure that no objects lled with liquids, such
as vases, are placed on the equipment.
16. The mains plug of the power supply cord shall remain
readily operable.
17. Do not connect the unit’s output to any other voltage
source, such as battery, main source, or power sup-
ply, regardless of whether the unit is turned on or o.
18. Do not remove the top (or bottom) cover. Removal
of the cover will expose hazardous voltages. There
are no user serviceable parts inside and removal may
void warranty.
19. If the equipment is used in a manner not specied by
the Exel Acoustics, the protection of the equipment
may be impaired.
CAUTION: To reduce the risk of re of electric
shock, do not expose this device to rain or mois-
ture.
CAUTION: Do not remove any covers, loosen any
xings or allow items to enter any aperture.
CAUTION: The rear of the product may get hot.
Avoid direct skin contact during operation and for
at least 5 minutes after power has been isolated.
CAUTION: The product must only be positioned at
oor level when operated in a horizontal position.

5
Operation Manual
www.tecnare.com
PRECAUCIÓN:Para reducir el riesgo de incendio
por desgarga eléctrica, no exponga este aparato a
la lluvia o a la humedad.
PRECAUCIÓN: No retire la cubierta, aoje torni-
llos o permita la entrada de elementos por ninguna
abertura.
PRECAUCIÓN: La parte trasera del equipo puede
calentarse. Evite el contacto directo con la piel du-
rante su funcionamiento y durante, al menos, 5 mi-
nutos después de que se haya apagado.
PRECAUCIÓN: El equipo solo debe colocarse en el
suelo cuando se opera en posición horizontal.
Antes de usar este producto, asegúrese de leer cuidadosamente el manual y las instrucciones de seguridad.
1. Lea estas instrucciones.
2. Conserve estas instrucciones.
3. Respete y siga todas las advertencias.
4. Siga todas las INSTRUCCIONES DE SEGURIDAD,
así como las advertencias de PELIGRO y OBLIGA-
CIÓN.
5. Utilice solo accesorios autorizados por Exel Acous-
tics SL.
6. No use este aparato cerca del agua.
7. Limpiar solo con un paño seco.
8. No bloquee las aberturas de ventilación e instalar de
acuerdo con las instrucciones de Exel Acoustics.
9. No instale el aparato cerca de fuentes de calor tales
como radiadores, calefactores estufas u otros apara-
tos que produzcan calor.
10. Esta unidad debe ser conectada mediante un cable
de alimentación de 3 hilos. Por razones de seguri-
dad, LA CONEXIÓN A TIERRA NO DEBE DESCO-
NECTARSE EN NINGUNA CIRCUNSTANCIA.
11. Proteja el cable de alimentación de ser pisado o
aplastado, especialmente los enchufes, receptáculos
y en el punto en el que salen del aparato.
12. Desconecte este aparato durante tormentas eléctri-
cas, terremotos o cuando no vaya a emplearse du-
rante largos periodos.
13. Confíe las reparaciones a personal cualicado. Se
equiere servicio cuando el aparato ha sido dañado
de alguna manera como por ejemplo si el cable de
alimentación o el enchufe está dañado, se ha derra-
mado líquido o han caido objetos dentro del aparato,
el aparato ha sido expuesto a lluvia o a la humedad,
no funciona con normalidad o se ha caído.
14. Desconecte completamente este aparato de la red
eléctrica desconectando el cable de alimentación.
15. No exponga este equipo a salpicaduras ni coloque
sobre él objetos que contengan líquidos, tales como
vasos o botellas. Equipo IP20.
16. El enchufe o la conexión a red debe ser facilmente
accesible.
17. No conecte la salida de la unidad a ninguna otra fuen-
te de voltaje, como batería o fuente de alimentación
independientemente de si la unidad está encendida
o apagada.
18. No retire la cubierta superior (o inferior). La retirada
de la cubierta lo expondrá a voltajes peligroso. No
hay piezas reparables por el usuario en el interior y
su extracción podría anular la garantía.
19. Si el equipo se utiliza de la forma no especicada por
Exel Acoustics, la protección del equipo puede verse
afectada.
IMPORTANTES INSTRUCCIONES DE SEGURIDAD

6
Operation Manual
www.tecnare.com
SYMBOL USED
AVERTISSEMENT DE SECURITE
Pour déconnecter l’appareil de l’alimentation principale de façon permanente, débranchez le connecteur du câble fourni à l’arrière
de l’appareil.
Ne retirez pas les couvercles, ne desserrez pas les xations et ne laissez aucune pièce s’introduire dans les ouvertures.
Ne placez pas d’objets contenant du liquide à proximité de l’appareil.
Ne remplacez le fusible de réseau principal que par un fusible du même type.
Le radiateur arrière de cet appareil devient chaud. Evitez tout contact direct avec la peau pendant le fonctionnement et au moins
5 minutes après la mise hors tension de l’appareil.
Warning
Caution
Notice
tip or pointer
This simbol indicate Risk of injury. It is essential to observe this warning. Non-compliance can lead to serious
injury or death.
Este símbolo indica Riesgo de lesiones. Es fundamental observar esta advertencia. Su incumplimiento puede
provocar lesiones graves o la muerte.
This simbol indicate Personal injuries. It is essential to observe this warning. Non-compliance can lead to minor
or slight injury.
Este símbolo indica Lesiones personales.Es fundamental observar esta advertencia. Su incumplimiento puede
provocar lesiones leves.
This simbol indicate Damage to the devices or environment. It is essential to observe this warning. Non-compli-
ance can lead to damage to property or equipment or environmental damage.
Este símbolo indica Daños a los dispositivos o al medio ambiente. Es fundamental observar esta advertencia.
Su incumplimiento puede provocar daños al equipo o daños al medio ambiente.
This simbol indicate information that contributes to better understanding.
Este símbolo indica Información que contribuye a una mejor comprensión del producto.

7
Operation Manual
www.tecnare.com
STANDARDS
FOR CUSTOMERS IN EUROPE
This product complies with both the LVD (electrical safety) 73/23/EEC and EMC (electromag-
netic compatibility) 89/336/EEC directives issues by the commission of the European com-
munity.
Compliance with these directives implies conformity with the following European standards:
EN60065 Product safety
EN55103-1 EMC emissions
EN55103-2 EMC immunity
This product is intended for the following electromagnetic environments: E1, E2; E3 & E4.
THIS PRODUCT MUST BE EARTHED. Use only a exible cable or cord with a green and yellow core which
must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the
installation. The cord must be a maximum of 2m long, have a 2.5mm2 CSA, a 300/500V rating and comply with
EN50525-2-11 / H05W-F.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be tted in to a 19” rack enclosu-
re and not operated unless so installed. The rack enclosure should be open at the front and back to allow free
ventilation and movement of air through the product.
FOR CUSTOMERS IN THE USA
This product has been tested for electrical safety and complies with UL60065 7th edition.
THIS PRODUCT MUST BE EARTHED. Use only a exible cable or cord with a green or green / yellow core which
must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the ins-
tallation. The cord must be a maximum of 6’ long, be 14AWG, have a rating SJ, SJT, SJE or 300/500V H05W-F
and be marked VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be tted in to a 19” rack enclosure
and not operated unless so installed. The rack enclosure should be open at the front and back to allow free ven-
tilation and movement of air through the product.
DECLARATION OF CONFORMITY WITH FCC RULES
We, EXELAcoustics SL, CL Encinar 282, Pol. Ind. Monte Boya, 45950 - Casarrubios del Monte (Toledo), España,
declare under our sole responsibility that this family of devices, complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
FEDERAL COMMUNICATIONS COMMISSION NOTICE
An example of this equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential and commercial installation.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfe-
rence to radio or television reception, which can be determined by turning the equipment o and on, the user is
encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

8
Operation Manual
www.tecnare.com
FCC Caution: Any changes or modications not expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
FOR CUSTOMERS IN THE CANADA
This product complies with CA /CSA C22.2 No.60065-03
Ce produit est conforme avec CA /CSA C22.2 No.60065-03
THIS PRODUCT MUST BE EARTHED. Use only a exible cable or cord with a green or green / yellow core which
must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the installa-
tion. The cord must be a maximum of 6’ long, be 14AWG, have a rating SJ, SJT, SJE or 300/500V H05W-F and be
marked VW-1.
CE PRODUIT DOIT ÊTRE MIS À LA TERRE. Utilisez uniquement un câble souple avec un noyau vert ou vert / jaune
qui doit être relié à la borne de terre de connecteur d’alimentation ou la borne de terre de l’installation. Le cordon
doit être un maximum de 6’ (2m) de long, 14 AWG (2.5mm2 CSA), être classé SJ, SJT, SJE ou 300/500V H05W-F
et être marquée VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be tted in to a 19” rack enclosure and
not operated unless so installed. The rack enclosure should be open at the front and back to allow free ventilation
and movement of air through the product.
CE PRODUIT EST CONÇU POUR UNE INSTALLATION PERMANENTE. Il doit être installé dans un boîtier rack
19-in. Le rack devrait être ouvert à l’avant et l’arrière pour permettre la ventilation et le mouvement d’air libre à travers
le produit .
DECLARATION OF CONFORMITY WITH CANADIAN ICES-003
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

9
Operation Manual
www.tecnare.com
EXEL ACOUSTICS SL
CL Encinar, 282. Polígono Industrial Monte Boyal. 45950 – Casarrubios del Monte (Toledo), España (Spain).
Declara que la serie de amplicadores 44TDAP y sus respectivas opciones, cumple con los objetivos de las Directivas:
Declare under our sole responsibility that the 44TDAP Series amplier products comply with relating Directives:
(1) Directiva de Baja Tensión - 2014/35/UE
(2) Directiva de Compatibilidad Electromagnética - 2014/30/UE
(3) Directiva RoHS - 2011/65/UE
(4) Directiva RAEE - 2012/19/UE
(1) Low Voltage Directive 2014/35/EU
(2) EMC 2014/130/EU
(3) RoHS Directive 2011/65/EU
(4) WEEE Directive 2012/19/EU
Y es conforme a las siguientes Normas Armonizadas Europeas:
In compliance with these Harmonized European Norms:
(1) EN60065 8th. Audio, video and similar electronic apparatus. Safety requirements.
(2) EN55032:2012. EMC emissions & immunity.
(3) EN55035-2017
DECLARACIÓN DE CONFORMIDAD
DECLARATION OF CONFORMITY

10
Table of Contents
www.tecnare.com 44TDAP Series Amplifier | rev.:1.0
44TDAP Series
Table of Contents
IMPORTANT SAFE INSTRUCTIONS ______________________________ 4
IMPORTANTES INSTRUCCIONES DE SEGURIDAD _________________ 5
SYMBOL USED_______________________________________________ 6
STANDARDS_________________________________________________ 7
DECLARACIÓN DE CONFORMIDAD _____________________________ 9
DECLARATION OF CONFORMITY _______________________________ 9
1. Welcome and unpacking ______________________________________ 11
1.1. Welcome to Tecnare_________________________________ 11
1.2. Unpacking ________________________________________ 11
1.3. The User Guide ____________________________________ 11
2. Installation Instructions _______________________________________ 12
2.1. Mechanical Installations ______________________________ 12
2.2. AC Power Connection _______________________________ 13
2.3. Audio Connections _________________________________ 13
2.4. Cooling___________________________________________ 15
3. Technologies and Key features _________________________________ 16
3.1. Introduction _______________________________________ 16
3.2. Main Features _____________________________________ 16
3.3. Preset Manager ____________________________________ 16
3.4. FIR Filtering _______________________________________ 16
4. Panel Interface User Guide ____________________________________ 17
4.1. Front Panel________________________________________ 17
4.2. The Rear Panel ____________________________________ 18
5. Quick Start_________________________________________________ 19
5.1. Loading a 2-way (Bi-amp) Preset_______________________ 19
6. Menu Map _________________________________________________ 20
6.1. Main Screen_______________________________________ 20
6.2. Menu ____________________________________________ 20
7. Processing Block Diagram ____________________________________ 22
8. Technical Specications ______________________________________ 23

11
Welcome
www.tecnare.com44TDAP Series Amplifier | rev.:1.0
44TDAP Series
1. Welcome and unpacking
1.1. Welcome to Tecnare
Thank you for choosing a Tecnare®44TDAP Series Digital Amplier Processed for your applica-
tion.
Please spare a little time to study the contents of this manual, so that you obtain the best possible
performance from this unit.
All Tecnare®products are carefully engineered for world-class performance and reliability.
If you would like further information about this or any other Tecnare®product, please contact us. We
look forward to helping you in the near future.
As part of a continuous evolution of techniques and standards, Exel Acoustics SL as manufacturer
of Tecnare® products reserve the right to change the specications of its products and the content of its docu-
ments without prior notice.
Updates and supplementary information are available on the Tecnare®website:
http://www.tecnare.com
Tecnare Technical Support is available at:
• (T): +34 918 170 110 - +34 918 171 001
Thank you again for placing your condence in Tecnare®products.
1.2. Unpacking
After unpacking the unit, please check carefully for damage. Every Tecnare product is tested and
inspected before leaving the factory and should arrive in perfect condition. If damage is found, please notify the
carrier concerned at once. You, the consignee, must instigate any claim. Please retain all packaging in case of
future re-shipment.
1.3. The User Guide
This user manual gives a progressively more detailed description of the functions of the Tecnare
44TDAP Series Digital Advanced Amplier. A detailed explanation of the front and rear panel controls, in con-
junction with Installation section, contains the basic information needed to safety install the amplier and place
it in service.
The nal section describes each individual function or feature with annotated images explaining its
use. Where appropriate, the graphical display is shown to further elaborate on the units operation.
To complete the manual a reference section is included, describing the technical performance and
Mechanical drawing of the device.

12
Installation
www.tecnare.com 44TDAP Series Amplifier | rev.:1.0
44TDAP Series
2. Installation Instructions
2.1. Mechanical Installations
The 44TDAP Series Amplier system is designed to be mounted in a standard 19” rack enclosure.
Where the amplier is used in a xed installation, as long as the bottom unit is supported and there
are no gaps between units, it is acceptable to use only the front panel 19” rack holes when tting it in a standard
rack enclosure. If the amplier is mounted in a mobile rack it is important that the rear is supported with a rear rack
mounting kit (part number TDK-TS). Damage caused by insucient support is not covered by the warranty.
To prevent damage to the front panel it is recommended that plastic cups or washers are tted under-
neath the rack mounting bolt heads.
It is possible to mount multiple 44TDAP Series ampliers without ventilation gaps between them, but
it is essential that an unobstructed ow of clean air is available from the front of the unit to the rear (cooling mode of
the 44TDA Ampliers, Also see “2.4. Cooling” on Page 15). It is important that neither the air intakes on the front of
the unit or the exhaust vents at the rear are covered. Steps must be taken to ensure that hot air does not continually
circulate through the amplier from the back of the rack to the front.
The amplier should never be exposed to rain or moisture during operation or storage. If the unit does
come into contact with moisture, disconnect the AC power cord immediately and leave it in a dry and warm location
to dry out.
44TDAP 5.0
Digital Amplifier Processed
ETHERNET
483mm
465mm
(376mm)
45mm

13
Installation
www.tecnare.com44TDAP Series Amplifier | rev.:1.0
44TDAP Series
Note that when any equipment is taken from a cold location into a hot humid one, condensation may
occur inside the device. Always allow time for the equipment to attain the same temperature as its surrounding envi-
ronment before connecting the AC power cord.
2.2. AC Power Connection
The amplier is tted with a 3 x 2.5mm² power cord and a 3-pin Shucko (CEE 7/7) power connector.
If the power plug mounted at the factory is not appropriate for your country, it can be removed and
the proper connector wired in its place as follows:
BLACK or BROWN LIVE
WHITE or BLUE NEUTRAL
GREEN or GREEN&YELLOW EARTH (GROUND)
The ampliers are designed to operate on 50/60 Hz AC power (±10%). The power supply sections
automatically congure themselves for either 115V or 230V nominal voltage at turn on. The ampliers will operate
over an extended range of supply voltages (please refer to the technical specications). The threshold of these rang-
es are: [115V range = 100-126Vrms]; [230V range = 207 - 253Vrms].
Note that whilst the amplier will operate correctly at voltages indicated, the specied output power
will only be achieved when operating with the stated nominal voltages.
2.3. Audio Connections
2.3.1. Input connections
For each input channel there is a female XLR-3 connector for analogue inputs. The 44TDA Series
can be fed with up to four balanced analogue audio signals.
The HOT, + or ‘in phase’ connection should be made to pin 2 of the XLR connector.
The COLD, - or ‘out of phase’ connection should be made to pin 3 of the XLR connector.
Pin 1 of the XLR connectors is internally connected to the chassis.
The shield of the input cable should always be connected Pin 1 of the XLR to ensure the EMC per-
formance and regulations are met.
Fig. 02: PIN out assignment 44TDAP Series Analogue Input/Link - Balanced connection
CAUTION: If you are not 100% condent of your competence to replace the mains plug,
engage qualied personnel to do the job
IMPORTANT: It is the responsibility of the user to ensure that dirt, liquids and vapour from
theatrical smoke and fog machines is not ingested by the amplier. Damage so caused is not
covered by the manufacturer’s warranty.

14
Connections
www.tecnare.com 44TDAP Series Amplifier | rev.:1.0
44TDAP Series
2.3.2. Using unbalanced connection
Please note that the use of unbalanced connections is not recommended, however, when connect-
ing the amplier to an unbalanced audio source, the signal conductor should be connected to XLR pin2. The ‘Cold’
conductor or cable screen should be connected to XLR pin 1 with a short connection made between pin 1 and pin3
as shown in Figure 03.
Fig. 03: Balanced to Unbalanced Analogue wiring and PIN out.
2.3.3. Amplier Output Connections
The 44TDAP ampliers are tter with one SpeakON™ NL4 connector per amplier channel. The
appropriate conductor terminations are shown below and on the rear panel of the unit.
Fig. 04 Amplier output connections - TDA Series
Additionally, the SpeakON™ NL4 connector for amplier channel 1 carries the output for amplier
channels 1 and 2. Similarly, the SpeakON™ NL4 connector for amplier channel 3 carries the output for amplier
channels 3 and 4. This can be useful for making a connection to two loudspeakers with one 4-core cable (i.e. Bi-amp).
Fig. 05 Amplier Output Bi-amp connexion (CH1) - TDA Series
In addition, the channel 1 or channel 3 connector can also be used if the pair of amplier channels is
being operated in bridged mode. It must be done, using the connection pin: 1+/2-
Fig. 06 Amplier Output Bridge connexion (CH1)
2+
1-
2-
1+
Speaker +
Speaker -
Bridge mode.
Pin No. NL4# CHA/C
1+ CH1 o/p +
2- CH2 o/p -

15
Connections
www.tecnare.com44TDAP Series Amplifier | rev.:1.0
44TDAP Series
2.3.4. Load Matching
Each output of the device can be optimised to drive either a low-impedance load (e.g. 2, 4 or 8
Ohms). The 44TDAP Series ampliers have adequate current capability to fully drive loads up to two ohms, however,
many high-performance “8-ohm” loudspeakers, especially multi-way systems with passive crossover network, have
impedances at some frequencies which are far lower than the average rating. An impedance minimum of 2 ohms or
less is not uncommon. For this reason, speaker impedance curves should be consulted before connecting speaker
in parallel.
The 44TDAP Series amps will do an outstanding job with any 8-ohm, full-range loudspeaker system,
and we expect equally outstanding performance when driving 4-ohm load. The 2-ohm load should be approached
with caution, as there is not further margin for impedance dips. The amp should not be damaged, but high-power
operation into reactive 2-ohm loads may result in overheating or excessive AC current consumption, causing shut-
downs. In addition, some power may be lost at those frequencies where the impedance dips below 2 ohms. For these
reason the operation with 2-ohm load should be tested thoroughly before putting into use.
2.4. Cooling
The 44TDAP Series devices use a force-air cooling system as follow: the cold air is sucked through
the ventilation hole of the front panel, and the heat is taken out from the rear panel. It allows high continuous power
levels without thermal problems.
2.4.1. Temperature Sensing and Protection
The 44TDAP is equipped with a sophisticated temperature sensing system which protects it from
any overheating which may occur as a result of inadequate ventilation. If the temperature exceeds 85 degrees, the
output voltage will be reduced, avoiding an excessive temperature rise. If the temperature continues to increase up
to 90 degrees, the power amplier will be shunted down. Once the temperature has fallen to a safe temperature, the
equipment will reboot automatically. After working for a while, if the cooling eect is not enough, please turn o the
equipment and remove the dust net cover to clean up the dust. If even doing this, the device still unable to recover
on its own, please contact our support team.
CAUTION: ever attempt to reverse the airow
Make sure an adequate air supply is provided in front of the 44TDAP, and that the
rear of the 44TDAP has sucient space to allow air to escape. If the 44TDAP is
rack-mounted, never operate the unit with any front or rear rack doors or covers
in position. It is recommended to keep the ambient temperature in the 0º~45ºC
(32º~113ºF). An increased temperature can have a signicant negative impact on
the expected lifetime on the components inside the 44TDAP.

16
Key Features
www.tecnare.com 44TDAP Series Amplifier | rev.:1.0
44TDAP Series
3. Technologies and Key features
3.1. Introduction
The 44TDAP DSP amplier systems integrate light-weight power supplies, high power sonically
transparent class-D ampliers, complete system monitoring and a fully featured ETHERNET network controlled 32
bit / 48kHz DSP processing platform,handled by the front panel dual Rj45 connectors, as standard.
44TDAP Series have been engineered for mid sized venues, rental and touring applications, adopt-
ing circuit architecture of multi-loop control technology, bearing-up constant resistance output and developed for
low-impedance and high-current, as a result we obtain a power amplier with a 90% eciency and an incomparable
stability.
All 44TDAP Series ampliers come with built-in active Power Factor Correction and soft switching
technology. It can ensures that a predominantly resistive load is presented to mains thus minimizing current distortion
and voltage/current displacement. This leads to improved performance of the amplier at high levels of output and
avoids mains-voltage collapses, typical of standard and switching power supplies. Another great advantage of this
technology is that its performance is, to a large extent, independent of mains voltage. The rated output power does
not vary with load/line conditions.
The advanced 48kHz DSP is fully integrated into the product and provides an amount of useful
features. Its powerful Limiter suite provides Peak and RMS limiting, as well as multi-band limiting for passive 2-way
enclosures. Many convenient features are provided as Gain, delay, EQ and a powerful FIR ltering with 512 taps,
bringing linear phase response to the Tecnare presets.
3.2. Main Features
• High eciency, energy-saving and emission-reduction
• Small size, light weight, 1U rack space
• Active Power Factor Correction (APFC)
• High reliability, meeting the requirements for high-quality audio system and engineering products
• Low noise of the power amplier and the mute fan
• 4-channels models
• Integrated 32bits, 48kHz DSP with FIR lters
• RMS & Peak limiter setting
• Multiband compressor
• Ethernet control
• 100-253c vac wide voltage adaptation range
• Amplier output DC protection
• Output overload/short-circuit protection
• High temperature power compression, over-temperature protection
• Undervoltage protection for power supply
3.3. Preset Manager
The 44TDAP Series amplier preset manager focusing to give a more speaker-based approach to
controlling, designing and recalling speaker congurations.
The Device Preset module, provides access to a full device preset of the device. The Speaker cong
module gives access to only one output channel block.
3.4. FIR Filtering
The advantages of FIR ltering include more arbitrary and ne control of a lter’s magnitude and
phase characteristics, independent control of magnitude, very long minimum-phase FIR based system EQ, horn
correction ltering, independent control of magnitude and phase, and mixed & maximum-phase characteristics.

17
Panel Interface
www.tecnare.com44TDAP Series Amplifier | rev.:1.0
44TDAP Series
44TDAP 5.0
Digital Amplifier Processed
ETHERNE T
4. Panel Interface User Guide
4.1. Front Panel
Fig. 7 Front panel
4.1.1. The Front Panel Layout
The front panel of the Device 44TDAP Series ampliers is a combination of button together with the
LCD display allows the user access to detailed information and control over the amplier’s status. This chapter illus-
trates all the functions and settings accessible via the amplier front panel.
All the setup and setting functions described in this chapter can be also accessed via computer with
PCC-NET software.
1. Ethernet Communication Port
The amplier may be controlled entirely from another controller, typically a Personal Computer, running
Tecnare PCC-NET software. Connection will normally be made to the controller via this Ethernet port
connector with shielded Cat-5e cables. This port is also used for updating the rmware in the unit. The
port is dual Rj45 built-in switch chip.
2. LCD Graphical Display
When the device is switched on, it will show on the default screen. It will have access to a ve setting
submenu. The screen contrast can be changed by pressing the encoder button to navigate to <Setting>
and using the encoder got to “Contrast” and using also the encoders to change the percentage; this can
also optimise the viewing angle.
3. Parameter Encoders
A velocity sensitive parameter encoder is used to adjust parameters shown on the display.
4. Power Switch
Applies mains power to the device.
5. Cooling vents
These opening force airow from front to back through the air lter.
3
1 2
5
5
4

18
Panel Interface
www.tecnare.com 44TDAP Series Amplifier | rev.:1.0
44TDAP Series
4.2. The Rear Panel
Fig.8 Rear panel
1. Audio Input Connectors
Analogue Audio Input Connectors- All audio connections are fully balanced and wired: pin-1 to ground
(as required by the AES48 standard), pin-2 hot & pin-3 cold.
2. Fans
Provides forced ventilation for front to back cooling.
3. Loudspeaker Connector CH1
The amplier SpeakON™ outputs. Connect the loudspeaker to the 1+ and 1- terminals. CH1 also car-
ries the (duplicated) loudspeaker output for channel 2 on terminals 2+ and 2-. Similarly, CH3 carries the
loudspeaker output for channel 4 on terminals 2+ and 2-. For Bridged mode, use terminals 1+ and 2- of
either CH1 or CH3.
4. Power Supply Input
Main input 100-240V operation. Not selectable. 3 x 2.5 mm² Power cord.
124
3
IMPORTANT: The device must be earthed to a suitable power earth; failure to do so may aect
performance and/or operation and will invalidate warranty and could be potentially hazardous.

19
Quick Start
www.tecnare.com44TDAP Series Amplifier | rev.:1.0
44TDAP Series
5. Quick Start
The 44TDAP Series amplier are not only powerful ampliers but, have a comprehensive processing ability,
allowing great systems as your design required. All you need to do is recall the appropriate Preset, connect your speakers and
source and away you go. This section shows you how to achieve the quickest, most straightforward set up using an 44TDAP5.0.
5.1. Loading a 2-way (Bi-amp) Preset
1. Connect the amplier. The 44TDAP requires mains connected to its main power and an input feed
signal, balanced analogue to the input XLRs. A 2-way loudspeaker run in bi-amp mode can be connect-
ed directly to output SpeakON® 1 and 3 as these also have channels 2 and 4 respectively connected
to pins 2± specically for bi-amp operations. See the chapters on mains, input and output connections
for more details.
2. Power up the amplier, once it has completed its power-up cycle the home screen will show.
3. Press one time the encoder button to access to preset menu.
4. Using the encoder control to scroll round to the required preset 2-way preset, e.g. Flat
5. Press one time again the encoder button and them the LCD will be displayed “Recall the data,
sure?”.
If you press “NO” you will come back to the preset menu. If you press “YES”, now the amplier will be
set with your desired preset.
Fig. 9 Home Screen
Fig. 10 Preset Screen
Fig. 11a & 11b Preset Screen
Fig. 12 Recall Screen

20
Menu Map
www.tecnare.com 44TDAP Series Amplifier | rev.:1.0
44TDAP Series
6. Using the encoder button, scroll round to the end of preset menu and press “back”.
6. Menu Map
Fig. 14 Menu Map
6.1. Main Screen
Main Screen Page can control the volume of all output channels of the power amplier. It will display
the output volume level, output clipping and output compression of each output channel. Also, it displays the device
operating temperature, network connection status and the current preset.
Press the rotary encoder to enter into the operation menu.
Fig. 15 Main Screen
6.2. Menu
6.2.1. Preset page
Fig. 16 Preset Screen
In the preset page, current is the currently loaded preset. The next lines show the available presets
contain into the device. A total of 16 preset can be stored. The device may contain a library of Factory Presets de-
signed to suit Tecnare loudspeakers.
Factory Presets may contain some parameters that are xed and hidden from view; the remainder
of the parameters are available for user manipulation. Typically crossover frequencies, output delay and some EQs
are hidden; those settings that are a function of the loudspeaker cabinet design and should not require adjustment
for dierent applications.
MAIN SCREEN
MENU
Preset Volume Settings Monitor Info
Digital Audio Power Amplifier
CHA: +0.0dB
CHB: +0.0dB
CHC: +0.0dB
CHC: +0.0dB
37,2ºC[ Flat ]
Preset
Back
Current: CLa21Plus
1. Flat
2. IBZA10
3. IBZA12
4. IBZA15
5. V10
Fig. 13 Preset Screen