TimeTools T100 Manual

T100 NTP Network Time Server
19-0218
Hardware Installation Guide
Models Covered: T100
Document Number: T1 00-01
7 January 017
The latest version of this user guide can be obtained from www.TimeTools.co.uk.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page
Important Safety Information:
Important Safety Information - Read the safety instructions before using this product.
1. Please read the manuals and retain for future reference. Please follow all instructions and heed all warnings.
. Do not use this apparatus near water.
3. Clean only with dry cloth.
4. Install in accordance with the manufacturer’s instructions.
5. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers)
that produce heat.
6. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
7. Only use attachments as specified by the manufacturer.
8. The unit has no user serviceable parts inside. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such as power-supply cord or power adapter is
damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain
or moisture, does not operate normally, or has been dropped.
9. Use the power adapter to disconnect the apparatus from the AC mains. The power adapter shall remain easily
accessible.
10. To completely disconnect unit power from the AC mains, disconnect the unit’s power adapter from the mains
socket. To reconnect power, plug the unit’s power adapter into the mains socket following all safety instructions and
guidelines.
11. Never push objects of any kind into this product through cabinet apertures as they may touch dangerous voltage
points or short out parts that could result in fire or electric shock.
For PERMANENT Y CONNECTED EQUIPMENT, a readily accessible disconnect device shall be incorporated
external to the equipment.
For P UGGAB E EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily
accessible.
Use only the supplied power adapter with the T100 NTP time server.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 3
CAUTION:
Before installing and configuring any T-Series NTP server
appliance, please read the manuals and retain for future reference.
Please follow all instructions and heed all warnings.
Full product documentation can be found on the supplied CD or at
www.timetools.co.uk.
While reasonable efforts have been taken in the preparation of this document to ensure its accuracy, TimeTools Limited
assumes no liability resulting from any errors or omissions in this manual, or from the use of the information contained
herein.
All claims based on information publicly available at time of printing.
All product or service names mentioned in this document are trademarks of the companies with which they are
associated.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 4
Table of Contents
1 Introduction................................................................................................................................................. 5
2 Key Features............................................................................................................................................... 5
3 Scope of Supply.......................................................................................................................................... 6
3.1 Optional Extras......................................................................................................................................................... 6
4 Front Panel.................................................................................................................................................. 7
4.1.1Alarm Indicator................................................................................................................................................... 7
4. USB Port................................................................................................................................................................... 7
4.3 Power Socket .......................................................................................................................................................... 7
5 Rear Panel................................................................................................................................................... 8
5.1 Ethernet Port - Eth0.................................................................................................................................................. 8
5. Console.................................................................................................................................................................... 8
5.3 GPS Antenna Connection......................................................................................................................................... 8
6 Installation................................................................................................................................................... 9
6.1 Locating the T100..................................................................................................................................................... 9
6. Antenna Connection................................................................................................................................................. 9
6.3 Connecting Ethernet................................................................................................................................................. 9
6.4 Connecting RS 3 Serial Console Cable...............................................................................................................10
6.5 Applying Power ..................................................................................................................................................... 10
7 Configuration............................................................................................................................................ 11
8 Certification and Compliance.................................................................................................................. 12
8.1 RoHS Compliance Statement................................................................................................................................. 1
8. REACH Regulation (EC) No 1907/ 006.................................................................................................................1
8.3 Environmental Policy.............................................................................................................................................. 1
8.4 EC Declaration Of Conformity................................................................................................................................1
9 Warranty.................................................................................................................................................... 14
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 5
1 Introduction
Network Time Protocol (NTP) can be used to synchronize the time on network clients, across an IP network, to the
correct time of an NTP time server. TimeTools NTP Servers provide a stratum 1 NTP Time Server for ensuring the time is
correct across an entire network.
The Network Time Server acquires time from the GPS satellite constellation and distributes time across a network using
the TCP/IP Network Time Protocol (NTP).
2 Key Features
16-Channel, High Sensitivity GPS Timing Receiver.
Can operate with outdoor, indoor or window located antenna, saving on cabling costs.
Timing receiver synchronises to less than 15 nanoseconds (GPS Locked).
NTP accurate to less than 3 microsecond (3x10-6 seconds) UTC (GPS Locked).
Synchronize in excess of 100,000 clients.
10/100 Mbit auto-sensing, auto-MDIX Ethernet ports.
IPv4 and IPv6 Internet Protocol.
Extremely cost-effective.
Universal AC/DC mains power adapter for world-wide operation.
Made in UK, with 1 -month warranty and free lifetime support.
*1. Assuming standard 1 8 sec NTP polling frequency.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 6
3 Scope of Supply
TimeTools T100 shipment typically includes the following components:
T100 GPS NTP Server Appliance.
T-3040 Pole Mounting GPS Antenna .
MT4-GPS Antenna Mount.
TCX-010 10m (30 ft) RG58 Cable.
GE1 I07-P1J 7.5V DC Universal Power Supply.
RS 3 Serial Console Lead.
Quick Start Guide.
CD containing user-guide, installation guide and white-papers.
3.1 Optional Extras
TCX-010 10m RG58 Cable.
TCX-030 30m RG58 Cable.
TCX-050 50m LMR195 Equivalent Cable.
TCX-100 100m LMR400 Equivalent Cable.
Custom cable lengths available on request.
SPP-GPS Multi-strike maintenance-free surge suppressor
T-AD 00-8 GPS Amplifier – 0db
GPS over optical fibre systems.
GPS Splitters – to 3 way, compact or rack-mount.
Digital NTP Wall clocks.
Analog NTP Wall clocks.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 7
4 Front Panel
The T100 has the following front panel indicators/connectors: Alarm, USB, Power.
4.1.1 Alarm Indicator
A red / green bi-colour LED on the T100 front panel indicates status and fault conditions.
4.2 USB Port
A USB port is provided for convenient and easy installation of firmware updates. Standard USB flash memory devices
can be used for firmware updates.
4.3 Power Socket
A .5mm DC power jack accepts .5 or .1 mm diameter plugs. The supplied power adapter can be used to power the
device. Use only the power adapter supplied by TimeTools with the T100.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 8
5 Rear Panel
The rear of the T100 has the following connectors: Eth0, Antenna, Console.
5.1 Ethernet Port - Eth0
The T100 has a single RJ45 10/100 MBit auto-sensing, auto-MDIX Ethernet port labelled Eth0.
Link: 10/100 Mbit, auto-sensing, auto-MDIX
Connector: RJ45
Cable Type: CAT 5.0
Modes: Half/Full Auto-negotiation.
5.2 Console
The Console port is a 9-way D-type female RS 3 serial connection for device configuration using dumb terminal
emulator. Null modem cable supplied for connection to standard 9-way PC serial interface.
RS 3 Console port pin-outs:
Pin : RX
Pin 3: TX
Pin 5: GND
The appliance has a secondary serial port for optional serial time code output. It is combined into the same 9-way D-type
connector as the console port. A custom serial cable is required to utilise the secondary serial port.
Secondary RS 3 Serial Port pin-outs:
Pin 7: TXB
Pin 8 : RXB
5.3 GPS Antenna Connection
The GPS antenna connector is a 50 ohm TNC female connector. It accepts a coax cable to a 5V GPS antenna. Use only
the antenna and cable supplied by TimeTools with the T100.
Connector: TNC female, 50 ohm
Cable: Coax, 50 ohm
Antenna Output Voltage: 5VDC
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 9
6 Installation
6.1 ocating the T100
Locate the appliance safely in a rack, on a shelf, or in a cupboard. The device should not be supported by the attached
cables.
CAUTION:
Do not install the T100 appliance where the operating ambient
temperature may drop below 0°C (3 °F) or exceed 50°C (1 °F).
6.2 Antenna Connection
The T100 antenna connection is a TNC female RF connector. It is provided for connection of an active 5 volt GPS
antenna via a coax cable.
WARNING:
Any local installation regulations for outdoor or rooftop mounted
antennas in the country where the antenna is installed must be
observed.
Please refer to the GPS/GNSS Antenna Installation Guide (Document Number: T1 0 -01) for further information on
antenna installation.
6.3 Connecting Ethernet
The T100 has a single 10/100 Mbit BaseT RJ45 auto-sensing, auto-MDIX Ethernet port.
The auto MDI-X feature, automatically detects the required cable connection type and configures the connection
appropriately, removing the need for crossover cables for peer to peer connection.
Connect one end of a CAT-5 patch cable to the RJ-45 network interface on the rear of the T100. Connect the other end
to a port on your network switch.
Alternatively, the T100 can be connected directly to a host PC Ethernet network port using a CAT-5 patch cable
for configuration purposes.
IMPORTANT:
When first installing the T100 on your network, ensure that no other
device on your network conflicts with the default IP address of the
appliance.
Default IP Address (Eth0): 19 .168.3.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 10
6.4 Connecting RS232 Serial Console Cable
The T100 Console port is a RS 3 serial port on a standard 9-way D-type connector. The console serial port can be
used configure the device from a host PC.
Using the supplied null modem cable, connect the T100 console port to the RS 3 serial port on a PC.
A terminal emulation program, such as Hyper-Terminal or Putty, can then be used to configure the device.
Terminal settings:
Connect Using: Direct to COMx (where x is the serial port number)
Bits per second: 115 00
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Terminal Emulation: VT100 / ANSI
Please refer to the T-Series User Guide (Document Number T1300-01) for configuration information.
6.5 Applying Power
The T100 has a .5 mm power jack on the front panel of the appliance.
Apply power by connecting the supplied power adapter into the power jack at the rear of the NTP server and into an
appropriate AC power source.
CAUTION:
For PERMANENTLY CONNECTED EQUIPMENT, a readily
accessible disconnect device shall be incorporated external to the
equipment.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed
near the equipment and shall be easily accessible.
Power Adapter Specification:
Manufacturer: MEAN WELL Enterprises Co., Ltd.
Model: GE1 I07-P1J
Input Voltage Range: 90 ~ 64VAC
Input Frequency Range: 47 ~ 63Hz
Output Voltage: 7.5VDC 1.33A
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 11
7 Configuration
Before configuring the NTP server, you will need to acquire the following basic configuration information:
IP address,
Network mask,
Default Gateway,
Domain name servers
or confirm availability of a network DHCP server for dynamic networking configuration.
The T100 can be configured in any one of three ways:
•Over a network using a web browser on a PC connected to the same network segment.
•Using a web browser on a PC using a peer-to-peer (direct cable) network connection.
•Using a dumb terminal emulator on a PC using a RS 3 serial connection.
Please refer to the T-Series User Guide (Document Number T1300-01) for configuration information.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 1
8 Certification and Compliance
8.1 RoHS Compliance Statement
This document certifies that the products manufactured by TimeTools do not contain the substances listed in the table
below in the concentrations exceeding the Maximum Concentration Value (MCV).
Substance Maximum Concentration Value
Lead 0.1% by weight (1000 ppm)
Mercury 0.1% by weight (1000 ppm)
Cadmium 0.01% by weight (100 ppm)
Hexavalent Chromium 0.1% by weight (1000 ppm)
Polybrominated Biphenyls (PBB) 0.1% by weight (1000 ppm)
Polybrominated Diphenyl Ethers (PBDE) 0.1% by weight (1000 ppm)
Products containing the substances listed in the table above, in concentrations below the MCV, are understood to be in
compliance with Directive 011/65/EU of the European Parliament and of the Council of 8 June 011 on the restriction of
the use of certain hazardous substances in electrical and electronics equipment (RoHS Directives). The stated
components are deemed as compliant as accord to definitions given in the directives (refer to directives). This document
also certifies that the materials declaration as provided by TimeTools is accurate to the best of our knowledge.
8.2 REACH Regulation (EC) No 1907/2006
TimeTools hereby certifies that to the best of its knowledge, and based on our suppliers’ information, parts and products
produced by TimeTools do not contain any of the substances referenced in the current list of Substances of High
Concern (SVHCs are defined in Article 57 of Regulation (EC) No 1907/ 006.) in concentrations greater than 0.1% weight
by weight.
8.3 Environmental Policy
TimeTools is committed to minimising the risk of any environmental damage or pollution caused by the company . We
ensure compliance with EU Directive 00 /96/EC Waste Electrical and Electronic Equipment, more commonly known as
the “WEEE directive”.
The WEEE Directive aims to:
Reduce waste associated with electrical and electronic equipment.
Improve the environmental performance of companies involved in the life cycle of electrical and electronic equipment.
For further information on the WEEE Directive or if you would like to arrange the collection and disposal of an old,
unserviceable or redundant piece of equipment that was originally supplied by TimeTools, please contact TimeTools via
email at [email protected]
8.4 EC Declaration Of Conformity
Please see the EC Declaration Of Conformity for TimeTools T100 model below.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 13
EC Declaration Of Conformity
We: TimeTools Limited
Of: Unit 3 Wombourne Enterprise Park, Bridgnorth Road, Wombourne,
South Staffordshire. WV5 0AL. UK.
Declare that: TimeTools T100 NTP Server
In accordance with the following directives:
1999/5/EC R&TTE Directive.
011/65/EU Restriction of the use of certain hazardous .
substances.
93/68/EEC CE marking and its amendments.
has been designed and manufactured to the following standards:
Safety: EN 60950-1: 006+A : 013 Information Technology Equipment
Part 1: General Requirements.
EMC: ETSI EN 301 489-1: V1.9. ( 011-09) EMC standard for radio equipment and
services.
ETSI EN 301 489-3: V1.6.1 ( 013-08) Specific conditions for Broadband Data
Transmission System.
ETSI EN 300 440- : V1.4.1 ( 010-08) Radio Spectrum Efficiency
EN 61000-3- : 014 Mains Harmonics
EN 61000-3-3: 013 Voltage fluctuations and Flicker
RoHS: EN 50581: 01 Restriction of hazardous substances.
I hereby declare that the equipment named above has been tested and found to comply with the relevant
sections of the above referenced specifications. The unit complies with all essential requirements of the
directive.
Signed by:
Name: Andrew Shinton
Position: Managing Director
Place and Date: TimeTools Limited, 1 April 017
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 14
9 Warranty
TimeTools Limited warrants the T100 NTP Time Servers to be free from defects in material and workmanship during a
1 -month period.
TimeTools Limited warrants GPS/GNSS antennas , GPS amplifiers, antenna cables and any integral batteries to be free
from defects in material and workmanship during a 1 -month period.
The Warranty begins on the date the unit is shipped from TimeTools.
TimeTools’ liability under this Warranty is limited to repairing or replacing, at TimeTools’ option, the defective equipment
and providing upgrade version changes for firmware. In case of repair, the product must be returned to an authorized
TimeTools Solutions Service Centre.
This Warranty does not apply if repairs are required due to acts of nature beyond TimeTools’ control such as, but not
limited to, lightning strikes, power surges, misuse, damage, neglect, or if repairs/modifications have been made or
attempted by anyone other than personnel authorized by TimeTools.
Disclaimer
IN NO EVENT WILL TIMETOOLS LIMITED BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES FROM THE SALE OR USE OF THIS PRODUCT.
THIS DISCLAIMER APPLIES BOTH DURING AND AFTER THE TERM OF THE WARRANTY. TIMETOOLS LIMITED
DISCLAIMS LIABILITY FOR ANY IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A SPECIFIC PURPOSE.
Repair and Returns
To obtain service under this Warranty, contact TimeTools at the address below during the Warranty period to receive a
Return Material Authorization (RMA) number and shipping instructions. Then ship the product, transportation prepaid, for
inspection.
Ship to:
TimeTools Limited
Attn: RMA XXXXXXX
Unit 34, Wombourne Enterprise Park,
Bridgnorth Road, Wombourne,
South Staffordshire.
WV5 0AL
UK
One-way shipping is the Customer's responsibility. TimeTools will pay the charges to return ship the equipment.
However, if the returned product is not found to be defective, then the buyer will be liable for all shipping charges. If the
buyer is located outside of the UK, then they will be liable for any duties and taxes payable, if applicable.
TimeTools will not be responsible for dismounting and remounting of the NTP server, for unauthorized returns or for
returns that do not list the RMA number and quantity returned on a packing list attached in plain view on the outside of
the shipping container.
017 TimeTools Limited. All Rights Reserved.

T100 Hardware Installation Guide. Page 15
TimeTools Limited.
Unit 34, Wombourne Enterprise Park,
Bridgnorth Road, Wombourne,
South Staffordshire.
WV5 0AL. UK
Tel: +44 (0) 190 897400
Fax: +44 (0) 870 1 3 1844
Email: info@TimeTools.co.uk
Web: www.TimeTools.co.uk
017 TimeTools Limited. All Rights Reserved.
Other manuals for T100
1
Table of contents
Other TimeTools Server manuals