TRONTEQ ROQSTAR User manual

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 1 of 16
Installation Guide
Industrial Ethernet Switch with PoE
ROQSTAR
Artikel Nr. 006-130-106
130-106.44 11/2017 ENG
130-106.44 112017 ENG

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 2 of 16
© 2017 TRONTEQ Electronic
All rights are reserved. The contents of this manual are protected by copyright. Their use is allowed as part of use of TRONTEQ
products. Any other use which goes beyond in particular copying, reproduction, translation requires written consent of
TRONTEQ Electronic.
TRONTEQ Electronic reserves the right to modify the contents of this manual.
In addition, we refer to the conditions of use specified in the license agreement.
The latest version of this manual is available online at www.tronteq.de.

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 3 of 16
Content
1. Safety Instructions......................................................................................................................... 4
1.1. Information about this operation instructions............................................................................ 4
1.2. Warning information system ..................................................................................................... 4
1.3. Qualified Personnel................................................................................................................... 5
1.4. Intended use ............................................................................................................................. 5
1.5. Liability Limitation...................................................................................................................... 5
1.6. Disposal .................................................................................................................................... 5
2. Device Description......................................................................................................................... 6
2.1. General ..................................................................................................................................... 6
2.2. Interfaces .................................................................................................................................. 6
3. Installation ...................................................................................................................................... 7
3.1. Mounting ................................................................................................................................... 7
3.2. Anschluss Power Port............................................................................................................... 8
3.3. Connection of Ethernet ports .................................................................................................... 8
4. First start-up ................................................................................................................................... 8
4.1. Default settings ......................................................................................................................... 8
5. PoE operation................................................................................................................................. 8
5.1. General ..................................................................................................................................... 8
5.2. Power budgeting....................................................................................................................... 8
6. LED Display .................................................................................................................................... 9
6.1. System status LED.................................................................................................................... 9
6.2. Ethernet port LED ..................................................................................................................... 9
6.3. PoE status LED......................................................................................................................... 9
7. Technical data .............................................................................................................................. 10
7.1. Electrical.................................................................................................................................. 10
7.2. Mechanical.............................................................................................................................. 11
7.3. Environment............................................................................................................................ 11
7.4. Standards and approvals........................................................................................................ 11
8. Wiring diagrams ........................................................................................................................... 12
8.1. Power cable ............................................................................................................................ 12
8.2. Ethernet M12 to RJ45 cable .................................................................................................. 12
8.3. Ethernet M12 to M12 cable.................................................................................................... 12
9. Order numbers ............................................................................................................................. 13
9.1. ROQSTAR Ethernet Switches ................................................................................................ 13
9.2. Accessories............................................................................................................................. 13
10. Contact.......................................................................................................................................... 14
10.1. Sales support....................................................................................................................... 14
10.2. Technical support................................................................................................................ 14
10.3. Specific product variants ..................................................................................................... 14

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 4 of 16
1. Safety Instructions
1.1. Information about this operation instructions
This operating instruction describes the application of the ROQSTAR Switches. It allows the safe and
efficient handling of the device. The operating instruction is a part of the device and must be available
for the users at any time.
Before the beginning of any work the user has to read carefully and understand these instructions.
The foundation for safe working is the compliance with all specified safety and handling instructions in
this operating instruction. In addition, the local accident prevention regulations and general safety
regulations apply for the handling with electrical energy and communications equipment.
The schemes and illustrations of this instruction are provided for basic understanding and may differ
from the actual design.
1.2. Warning information system
This manual contains notices you have to observe in order to ensure your personal safety, as well as
to prevent damage to property. The notices referring to your personal safety are highlighted in the
manual by a safety alert symbol, notices referring only to property damage have no safety alert
symbol. These notices shown below are graded according to the degree of danger.
DANGER!
Indicates that death or severe personal injury will result if proper
precautions are not taken.
WARNING!
Indicates a potentially dangerous situation that may result in death or
serious injury if it is not avoided.
ATTENTION!
Indicates a potentially dangerous situation due to hot surfaces, which may
result in minor or light injuries if it is not avoided.
CAUTION!
Indicates that minor personal injury can result if proper precautions are not
taken.
Hint for useful tips and recommendations for efficient and trouble-free
operation.

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 5 of 16
1.3. Qualified Personnel
The user must ensure that only qualified personnel will work with the device. The product/system
described in this documentation may be operated only by personnel qualified for the specific task in
accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying
risks and avoiding potential hazards when working with these products/systems.
1.4. Intended use
Proper transport, storage, installation, assembly, commissioning, operation and maintenance are
required to ensure that TRONTEQ products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be
observed.
1.5. Liability Limitation
All information and instructions in this operating instruction has been compiled in accordance with
current standards and regulations, state of the art as well as the knowledge and experience of the
applications in the field. In the following cases the manufacturer is not liable for damages:
►Disregard of the operating instructions in this manual.
►Improper use.
►Employment of non-qualified personnel.
►Unauthorized technical modification or reconstruction.
►Use of other connectors as delivered.
The general terms and conditions are valid as well as the delivery terms of the manufacturer and the
legal regulations which were taken when the contract was concluded.
We have reviewed the contents of this publication to ensure consistency with the hardware and
software described. Since variance cannot be precluded entirely, we cannot guarantee full
consistency. However, the information in this publication is reviewed regularly and any necessary
corrections are included in subsequent editions.
1.6. Disposal
The device should be disposed of after use in accordance with the current disposal regulations as
electronic waste.

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 6 of 16
2. Device Description
2.1. General
ROQSTAR is an Ethernet Switch family with different functions for the use in industry and in transport
applications.
With PoE (Power over Ethernet) different Ethernet devices (PD) can be power over the Ethernet
cable. The ROQSTAR PoE has an integrated power supply with galvanic isolation. The Switch
provides a total power supply of 60W for all connected PD (Powered Devices). PoE/PoE+ PD devices
are supported.
The ROQSTAR PoE Switch is robust, has a high reliability and can be deployed in a wide range of
applications such as CCTV and camera on vehicles or decentralized machine automation.
2.2. Interfaces
Here is an example of the ROQSTAR Switch, the image can differ depending on variants.
Digit
Description
1
System-LED
V1 = power supply 1: supplies Switch and PoE
V2 = power supply 2: supplies only Switch
2
Power port
3
Ethernet port
4
Ethernet port LED:
L/A = Link/Activity
PoE = PoE status
5
Ground connection
1
2
3
4
6

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 7 of 16
3. Installation
WARNING!
Never perform wiring electrical connections if they are under voltage!
Do not perform any assembly work on the device when it is under voltage!
3.1. Mounting
Perform the following steps for mounting the device:
►Make sure that all electrical connectors are volt-free.
►Make sure that the device is disconnected from all connections.
►Prepare the drill holes at the installation site.
►Mount the device on a flat surface with four M4 screws.
►Ground the device via the provided ground connection.
Make sure that the ground connection is always tightened securely. Use
toothed lock washers with internal teeth to produce ideal contact.

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 8 of 16
3.2. Anschluss Power Port
The Ethernet Switch can be powered by only V1 or V2 or redundant with V1 and V2. The power
supply for PoE function is V1 only.
Pin
Name
Description
Image
1
V1
power supply 1, plus pole
2
V2
power supply 2, plus pole
3
FAULT
Fault Contact
4
FAULT
Fault Contact
5
GND
power supply common minus pole
3.3. Connection of Ethernet ports
Pin
Allocation
Connection
PoE function
Image
1
TD+
Transmit Data +
0V
2
RD+
Receive Data +
+53V
3
TD-
Transmit Data -
0V
4
RD-
Receive Data -
+53V
4. First start-up
4.1. Default settings
The ROQSTAR PoE is an unmanaged Switch, therefore no configuration can be made. After wiring
the power supply connection the Switch transfers data on all Ethernet ports. The PoE function is
available on each port. As soon as a PD is connected and registered the PoE voltage is activated at
that port.
5. PoE operation
5.1. General
The PoE function is avaible about 10 seconds after the operating voltage is activated at V1. The
Switch provides a total power output of 60W. The PoE total power output is monitored by the Switch.
The PoE voltage is 53V. Is a PD succesfully registered then the voltage is activated on the respective
port and the PoE status LED lights up permanently.
5.2. Power budgeting
The power budgeting is based on PoE classes. All combination of classes with a total power budget of
60W are supported. The PoE classes are defined as follows:
Class
Power from
Switch per
port
Power range at
PD, depends on
cable length
0
15.4W
0.44W –12.95W
1
4.0W
0.44W –3.84W
2
7.0W
3.84W –6.49W
3
15.4W
6.49W –12.95W
4
30.0W
21.90W –25.5W
If the total power budget is exceeded, the voltage on the registering PD device is locked. In this case
the PoE status LED blinks.

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 9 of 16
6. LED Display
With the LED display, you can perform an initial, rapid device diagnosis.
6.1. System status LED
LED
Color
Activity
Operating state
V1
-
aus
power supply V1 is not connected
green
lights up
power supply V1 is connected
V2
-
off
power supply V2 is not connected
green
lights up
power supply V2 is connected
6.2. Ethernet port LED
LED
Color
Activity
Operating state
L/A
-
off
no network connection (Link Down)
green
lights up
network connection with 10 Mbit/s or 100 Mbit/s (Link Up)
green
blinks
data traffic
6.3. PoE status LED
LED
Color
Activity
Operating state
PoE
-
off
PoE voltage is not ativated
yellow
lights up
PoE voltage is activated, PD is powered
yellow
blinks
port: Power Budget exceeded, PD is not powered
all: failure of PoE function

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 10 of 16
7. Technical data
7.1. Electrical
Parameter power ports
min.
typ.
max.
Dimension
Operating voltage (V1) SELV
+16
+24
+52
VDC
Reset level (V1)
-
10
-
VDC
Operating voltage (V2) SELV
+9,6
+24
+60
VDC
Reset level (V2)
-
8
-
VDC
Current consumption, (PoE load = 60W)
V1 = 16V
V1 = 24V
V1 = 52V
-
-
-
-
-
-
5
3,2
1,5
A
A
A
Peak inrush current
<1ms
-
10 @ 9,6V
14 @ 60V
A
Power consumption, (PoE Last = 60W)
V1 = 16V
V1 = 24V
V1 = 52V
-
-
-
-
-
-
80
80
80
W
W
W
Immunity of power interruption
10
-
-
ms
Internal fuse
2A, T
-
Internal fuse PoE
7A, T
-
Ethernet-Ports
min.
typ.
max.
Dimension
Switch architecture
Store-and-Forward
Bitrate
-
10 / 100
-
Mbit/s
Output resistance
-
100
-
Input resistance
-
100
-
Latency at 90 % load
at 100 Mbit/s (frame size 64 / 1518 Byte)
at 10 Mbit/s (frame size 64 / 1518 Byte)
-
-
8 / 125
8 / 125
9 / 133
9 / 133
µs
µs
Throughput unicast packets
Frame size 64 –1518 Byte
-
Full wire
speed
-
Frame size
without VLAN Tag
with VLAN Tag
64
64
-
1518
1522
Byte
Byte
PoE parameter
min.
typ.
max.
Dimension
Voltage
51
53
55
VDC
Current per port
-
560
600
mA
Fuse per port
-
700
-
mA, T
Total power output PoE
-
-
60
W

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 11 of 16
Isolation
Parameter
min.
typ.
max.
Dimension
Ethernet Port ↔Ethernet Port
-
-
-
VDC
Ethernet Ports (PoE) ↔V1, V2
± 2250
-
-
VDC
Ethernet Ports ↔housing (ground)
± 2250
-
-
VDC
housing (ground) ↔V1, V2
± 850
-
-
VDC
7.2. Mechanical
Parameter
typ.
Dimension
Dimensions (H x B x T, ± 0,5 mm)
121 x 175 x 52
mm
Mass net
530
g
Housing protection class
IP54
-
Mounting
drilled hole for four M4 screws
-
7.3. Environment
Parameter
min.
typ.
max.
Dimension
Ambient temperature during operation
durable
15min
-40
-40
-
-
+70
+85
°C
°C
Ambient temperature storage
-40
-
+85
°C
Humidity (not condensing)
10
-
95
%
Air pressure during operation
690
(3000 m
over NN)
-
-
hPa
7.4. Standards and approvals
The device is compliant with the following test standard.
►Electromagnetic radiation:
►EN61000-6-4
►EN55022: Class A
►FCC47 CFR Part 15 Class A
►Immunity against conducted interference and external fields:
►EN61000-6-2
►EN61000-4-2
►EN61000-4-3
►EN61000-4-4
►EN61000-4-5
►EN61000-4-6
►Specific applications
►EN50155
►EN50121-4
►EN61131-2
►UNECE (E1) R10
►UNECE (E1) R118

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 12 of 16
8. Wiring diagrams
8.1. Power cable
Connector
Diagram
Pin assigment*
1
brown
V1
2
white
V2
4
black
Fault
3
blue
Fault
5
yellow/green
GND
* for accessories Order-No. 006-000-003 or 006-000-004
8.2. Ethernet M12 to RJ45 cable
M12 connector
Diagram
RJ45 connector
8.3. Ethernet M12 to M12 cable
Connector
Diagram
Connector

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 13 of 16
9. Order numbers
9.1. ROQSTAR Ethernet Switches
Order-No.
Product code
Description
006-130-100
ROQ-08F-U-LV-IP54
8-Port Fast Ethernet Unmanaged M12 Switch
006-130-101
ROQ-08F-L-LV-IP54
8-Port Fast Ethernet Lite Managed M12 Switch
006-130-102
ROQ-08F-F-LV-IP54
8-Port Fast Ethernet Full Managed M12 Switch
006-130-103
ROQ-08F-S-LV-IP54
10-Port Fast Ethernet Security Managed M12 Switch
006-130-104
ROQ-08F-E-LV-IP54
8-Port Fast Ethernet Expandable M12 Switch
006-130-106
ROQ-08F-E-LP-IP54
8-Port Fast Ethernet Unmanaged M12 PoE Switch
9.2. Accessories
Order-No.
Description
006-000-003
M12 power supply cable for ROQSTAR Switches, 2m, straight
006-000-004
M12 power supply cable for ROQSTAR Switches, 2m, angled
006-000-042
Ethernet cable CAT5e, M12 to RJ45, 1m
006-000-025
Ethernet cablel CAT5e, M12 to M12, 3m
006-000-007
Adapter cable M12 to USB Typ A Buchse
006-000-008
USB flash drive

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 14 of 16
10. Contact
10.1. Sales support
Please contact our sales team at sales@tronteq.de for further inquiries and questions regarding our
products.
10.2. Technical support
Please contact our support team at support@tronteq.de if you have any technical questions or if you
need technical training.
10.3. Specific product variants
You have a specific problem and you need a product variant that doesn’t exist today. Please contact
us for customer specific adaption of our product. Please visit us at www.tronteq.de.

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 15 of 16

Installation Guide ROQSTAR
Document no. 130- 106.44 11/2017 ENG Page 16 of 16
TRONTEQ Electronic
Siemensstrasse 22
72766 Reutlingen
www.tronteq.de
Other manuals for ROQSTAR
2
Table of contents
Other TRONTEQ Network Router manuals
Popular Network Router manuals by other brands

Proxicast
Proxicast EtherLINQ quick start guide

Vision Systems
Vision Systems VPNRouter iR 5221 manual

WM Systems
WM Systems M2M Router NB user manual

ooma
ooma Linx quick start guide

Dynalink
Dynalink RTA210 Quick setup guide

Cisco
Cisco Network Convergence System 6000 Series Unpacking, moving, and securing guide