Twyford Sola SF2105CP User guide

sola touch tap
battery operated monobloc
INSTALLATION, OPERATING AND MAINTENANCE
INSTRUCTIONS
PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER
SF2105CP

2
IN TRODUCTION
This installation guide has been produced for the battery operated basin mounted tap.
These instructions cover the installation, operation and maintenance. Please read
the enclosed instructions before commencing the installation of this product, please
note;
W E RECOM MEN D THA T THE IN STA LLA TION OF A N Y TW YFORD
PRODUCT IS CA RRIED OUT BY A N A PPROV ED IN STA LLER
The installation must be carried out strictly in accordance with the Water Supply
(Water Fitting) Regulations 1999 and any local authority regulations.
If in doubt, we would recommend that you contact either your local water
authority, the secretary of the Water Regulations Committee at WRc on Tel: 01495
248454 or Institute of Plumbing on Tel: 01708 472791.
IMPORTA N T
TECHN ICA L DA TA
When installing the product, care must be taken not to damage/affect the finish
of this product. To ensure the finish of this product is maintained, we recommend
that this product be cleaned periodically with a soft cloth and mild detergent. The
use of any type of abrasive or solvent-based cleaners is not recommended.
All products MUST be re-commissioned to suit site conditions to ensure optimum
performance levels of the product are obtained.
Product control: Touch using Piezo technology
Installation: Basin mounted
Hot water temperature: 70˚ C maximum
Water pressure: 0.5 to 8.0 bar (7 to 116 psi)
With water pressure in excess of 8 bar
use with a pressure reducing valve.
Power specification: 9V low voltage system
Power supply: 6 x 1.5V AA batteries
Alternatively 1 x 9V battery
Default flow time: 20 seconds
Flow regulator (fitted) 6 litres per minute (max)

3
DIMENSIONS
100
95
58
Ø32
Ø45
15˚
120˚

4
CHECK CONTENTS
Before commencing remove all components from packaging and check each
component with the contents list.
Ensure all parts are present, before discarding any packaging. If any parts are
missing, do not attempt to install your electronic tap until the missing parts have
been obtained.
Item Qty Components
1 1x Tap and attachments
2 1x Filter
3 1 x IP67 battery box
4 1x Allen key 2mm
1
4
2
3
5 1 x Flow regulator 6Ltr/min
5

5
PRE-IN STALLA TIO N IN FO RM A TIO N
Prepa ra tion for insta lla tion
Flush the water supply pipes thoroughly prior to installation. Do not allow
debris, PTFE tape or any metal particles to enter the tap.
Turn o the water supply.
Importa nt - All plumbing is to be installed in accordance with applicable
codes and regulations.
IN STALLA TIO N
S tep 1 - Prepa ra tion for mounting the ta p
1. S hut o the water supply and remove the hexagonal nut, washer and
gasket from the threaded inlet.
Step 2 - Insta lling the ta p
1. Position the tap with the ‘O’ ring located in the base into the hole in the
basin or water proof work surface. Ensure the ‘O’ ring is located correctly.
2. Slide the gasket over the exible hose.
3. Secure the tap to the basin or work surface using the hexagon nut and disk.
Step 3 - C onnecting the wa ter supply
1. A service ball valve must be installed in the supply
pipe to enable the tap to be isolated for servicing
should it be required.
2. Connect the pipe from tap to the solenoid valve and
then from the solenoid valve to the service ball valve.
Ensure the ow direction through the solenoid valve is
the same as indicated by the arrow on the valve body.
3. Ensure the lter is assembled between the inlet joint
and the solenoid valve.
4. Turn on the water supply and check for leakage.
5. Isolate via the service ball valve and tighten or remake
joints if leakage occurs.
Flow

6
Step 4 - Connecting the power supply
1. Install the battery box on the wall under the basin using the screws
provided or the two sided adhesive foam tape.
INSTALLATION
FLOW TIME ADJUSTMENT
Adjustment levels
The flow time is programmable after installation.
If necessary, the default flow time of 20 seconds can be adjusted.
The adjustment mechanism is composed of 3 adjustment levels for changing the
flow time. An indicator light (LED) will guide you from one level to the next.
In each adjustment level the flow time can be changed by incremental steps. The
following table shows the number of steps in each level, the increment of each
step and how to recognise in which adjustment level you are in.
To operate the tap, simply touch the
designated area on the Piezo cap, the tap
will open and water will start to flow.
To turn off the tap before the flow time has
expired touch the cap again in the
designated area.
OPERATION

7
FLOW TIM E A DJUSTMEN T
A djustment levels
Level 1 Level 2 Level 3 Out of
adjusting mode
No of steps 10 steps 10 steps 2 steps
Seconds to
be
increased by
touching
once
1 second 2 second 15 second
Adjustment
level
indicator
After entering
into the
adjustment
mode level 1
is reached
Indicator
light flashes
twice
Indicator
light flashes
3 times
Indicator light
flashes 4
times
The following example shows how to manage the adjustment levels:
Ex ample 1: You wish to adjust the flow time to 20 seconds.
At level 1 perform 3 steps of 1 second (3s). Total: 3 seconds.
Go to level 2 and perform 1 step of 2 seconds (2s). Total: 5 seconds.
Go to level 3 and perform 1 step of 15 seconds (15s). Total: 20 seconds.
Ex ample 2: You wish to adjust the flow time to 45 seconds.
At level 1 perform 1 steps of 1 second (1s). Total: 1 seconds.
Go to level 2 and perform 7 step of 2 seconds (14s). Total: 15 seconds.
Go to level 3 and perform 2 step of 15 seconds (30s). Total: 45 seconds.
Ex ample 3: You wish to adjust the flow time to 60 seconds.
At level 1 perform 10 steps of 1 second (10s). Total: 10 seconds.
Go to level 2 and perform 10 step of 2 seconds (20s). Total: 30 seconds.
Go to level 3 and perform 2 step of 15 seconds (30s). Total: 60 seconds.

8
FLOW TIME ADJUSTMENT
How to adjust the flow time
1. Disconnect the power supply between
the battery box and tap.
2. Using the Allen key unscrew the socket
screw and remove the Piezo cap.
3. Touch the Piezo cap on the normal
face with the markings, to empty all
the power remaining in the cap.
4. Wait ten seconds before re-connecting the power supply.
5. The indicator light (LED) on the under side of the Piezo cap as shown
(normally hidden) will start flashing. After a few flashes the LED will give a
steady red light. When this happens enter the adjustment mode at level 1
by touching the normal face of the Piezo cap within a few seconds.
6. By touching the Piezo cap the new flow time will be programmed. In
adjusting mode level 1, each touch of the Piezo cap will increase the flow
time by 1 second. The LED will flash every time the Piezo cap is touched to
perform a new step.
7. If the desired flow time is within 10 seconds, no other adjusting levels are
needed and you can stop pressing the Piezo cap. The LED will flash 2 twice
followed by 3 times and 4 times after which you will have left the adjusting
mode. The tap is now set to the desired flow duration.
8. To perform steps at adjustment level 2, wait until the LED has flashed twice,
then touch the Piezo cap the required number of times, with a maximum of
10 steps of 2 seconds.
9. If level 3 is not required stop pressing, the LED will flash 3 times and then
after a further 4 times, you will have left the adjusting mode. The tap is now
set to the desired flow duration.
10.To perform steps at adjusting level 3, wait until the LED has flashed 3 times,
then touch the Piezo cap the required number of times, with a maximum of
2 steps of 15 seconds.
11.To leave the adjusting mode wait until the LED has flashed 4 times, the tap
is now set to the desired flow duration.
12.Replace the Piezo cap into the tap body and re-tighten the retaining screw.
LED
Light

9
LOW BA TTERY IN DICA TOR
The tap has an advanced battery level management system consisting of 2
steps.
The first step is activated when the battery reaches a level of 7.7 volts, at this
point the battery still has enough power to open and close the solenoid valve.
The battery level management system allows the solenoid valve to open, but will
activate the LED warning light at the back of the Piezo cap. The LED will flash
twice when the battery management system has activated level 1.
The second step is activated when the battery might not have enough power to
open and close the solenoid valve. The battery management system does not
allow the solenoid valve to open, instead it provides 2 closing pulse. The LED
warning light will flash 3 times when the battery manage system has activated
level 2.
Battery replacement instructions
1. Carefully open the battery box.
2. Remove the old batteries.
3. Replace the used batteries with 6 new 1.5 V AA batteries.
4. Close the box.
FILTER CLEA NIN G
The tap is provided with one stainless steel filter to prevent foreign particles from
entering the solenoid valve and tap.
If the water flow has decreased this may be due to the filter becoming clogged,
which can be cleaned as follows:
1. Shut off the water supply at the service valve installed in the supply pipe
(not provided).
2. Disconnect the water supply inlet adaptor on the inlet to the solenoid valve.
3. Remove the filter from the adaptor and wash it thoroughly under running
water.
4. Re-assemble the filter and adaptor to the solenoid valve.
5. Turn on the water supply and check to ensure there is no leakage from any
joint.

10
Twyford Bathrooms battery operated taps have a high quality finish and should be
treated with care.
To ensure the finish of this product is maintained, we recommend that this product
be cleaned periodically with a soft cloth and mild detergent.
The use of any type of abrasive or solvent-based cleaners is not
recommended.
When cleaning bathroom tiles the tap should be protected from any splattering
of harsh cleaners.
A FTERCA RE INSTRUCTION S
Solenoid Valve Kit Cat. No. 07230002
Solenoid Housing Kit Cat. No. 07231001
Seals and Screws Kit Cat. No. 07210043
Cover Kit Cat. No. 07270023
Diaphragm Cat. No. 04500001
Battery Box Cat. No. 06530020
SPA RE PA RTS
W A RRA N TY
Limited W arranty
This product is covered by a limited warranty for one year from the date of
purchase.
During this period Twyford Bathrooms undertakes, at its option, to repair or
replace any faults caused by defective material or manufacturing faults that may
arise (see Twyford Bathroom’s Warranty).
This guarantee does not cover faults or damage caused by incorrect installation
and/or maintenance, wear and tear, battery or water composition (eg hard
water). This includes but is not limited to the following:
tIncorrect installation, inversion of supply pipes.
tPressure or temperatures exceeding the recommended limits.
tImproper use, tampering, bad or lapsed maintenance.
tForeign bodies, dirt or scale introduced by the water supply.

11
SERVICE CHECK LIST
Check the flow time. If it needs adjusting
follow the instructions on pages 7 and 8.
Check the solenoid valve. If debris or
scale are present, unscrew the solenoid
valve, pull out the plunger and the spring
and clean them and remove any debris
present.
Use scale remover if required. When
replacing the spring make sure that it is in
vertical position.
Check the batteries. Low or used
batteries, replace with new, see page 9.
Check the flow time, see pages 7 and 8.
Check the connection between the Piezo
cap connector and the solenoid connector.
Check the battery box is correctly
connected.
Check the solenoid valve. If debris or
scale are present, unscrew the solenoid
valve, pull out the plunger and the spring
and clean them and remove any debris
present.
Use scale remover if required. When
replacing the spring make sure that it is in
vertical position.
Check the diaphragm. If needed, clean
the orifice or replace it.
Check the w ater supply pressure. It must
be 0.5 to 8.0 bar (7 to 116 psi). With
water pressure of more than 8 bar, fit a
pressure reducing valve.
Check the filter. If needed, remove and
clean it, see page 9.
N o w ater flow ing from the tap
W ater flow diminished
W ater flow does not stop

10
Twyford Bathrooms
Lawton Road
Alsager
Stoke on Trent
ST7 2DF
UK
UK Technical Helpline
Phone: 0870 840 0437
Fax: 0870 840 0438
Installation Instruction No FI 20000 09/08
02/09
12
Table of contents
Other Twyford Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

Hans Grohe
Hans Grohe Vernis Shape 70 71560 Series Instructions for use/assembly instructions