Tylo Prime+ 1814 User manual

4 person infrared sauna
Prime+ 1814
User Manual
Note: The cabin must be installed on a flat, level surface.
Precautions to be taken before commissioning
2
Pre-assembly information
2
Electrical requirements
2
Cabin construction/assembly
3
Junction box connections
3
Main junction box connections
5
Power connections on the ceiling
7
Control panel instructions
10
Lighting: Internal/external/colour therapy
12
Maintenance & technical support
11
Wiring diagram
12
121210
Page 1

Precautions to be taken before commissioning: Warning (space configuration and use):
•Correct electrical earthing is required
•Electrical sockets are not permitted in the sauna.
•Do not allow heating elements to come into contact with water.
•Do not fit a lock or bolt on the door.
•Do not block the ventilation holes.
•Children must always be supervised in the sauna.
•Clean the sauna with a damp cloth.
•Cleaning the sauna with steam cleaners, high pressure cleaners or spraying with water is not permitted.
Warning notice: Do not insert the sauna power cable into a socket before assembly is complete.
Warning (health restrictions):
•Being exposed to high temperatures for a long time may lead to hyperthermia (body temperature is several
degrees above 37° Celsius)
•Hyperthermia symptoms include: dizziness, lethargy, grogginess and feeling faint. Effects of hyperthermia:
oFailure to realise that you have to leave the infrared sauna.
oDamage to the foetus in pregnant women.
oBeing physically unable to leave the sauna.
oLoss of consciousness
•Warning – the consumption of alcohol or drugs increases the risk of fatal hyperthermia.
•If you have health problems or are ill, consult your doctor before using the sauna.
•Stop using it immediately if you feel restless, if you start shaking, if you have a headache
or feel sick or nauseous.
•People who suffer from hyperthermia or cardiovascular diseases should seek medical advice before
using the infrared sauna.
•Do not use a sauna if you have drunk alcohol or taken tranquillisers or if you suffer from pain in the heat.
•Using the infrared sauna is not advisable if you have been exposed to UV radiation (a solarium or been
sunbathing) in the last 24 hours.
•Should you notice unusual skin changes after using the infrared sauna e.g. persistent erythema (reddening
of the skin for more than one day) or a reticular change in colour, you should stop using it and seek medical
advice.
Warning (fire risk):
•Do not use the sauna to dry clothing, bathing costumes etc.
•Do not hang towels or other objects on or in front of the infrared heat radiator.
•Never operate the infrared sauna with a damaged cable or a damaged socket.
Pre-assembly information:
a. Two (2) adults are required for assembling and installing the sauna.
b. Assembly tools: Phillips screwdriver
c. The boxes are labelled in order of assembly.
d. Note: The glass for assembling the front cabin panel is heavy and fragile.
Box 1: Floor, ceiling, bench valance, bench, fan component and manual
Pack of 10 Phillips screws for the junction box covers
Door handle set
Box 2: Back and front wall panels
Box 3: Left and right wall panels
Electrical requirements: The infrared sauna must have a 230 volt connection.
Page 2

How to construct the sauna:
Note – there are (12) power connections inside the sauna.
Note – there are (12) power connections in the sauna ceiling.
(12) are in the sauna: Back wall panel, left and right wall panels, bench valance,
bench valance fan, bench and mains connection
(12) There are additional power connections on the top outer face of the ceiling.
(1) Mains connection cable for the sauna. Do NOT insert the main electrical
connection cable for the sauna into the socket before all the assembly steps
have been completed correctly.
------------------------------------------------------------------------------------------------------------------------------------------------
There are (12) power connection/ junction boxes that are labelled accordingly and must be connected
after assembling each section.
Back wall panel Left Right Bench valance Bench
B1 to B1 L1 to L1 R1 to R1 S3 to S3 S1 to S1
B2 to B2 L2 to L2 R2 to R2 S4 to S4 S2 to S2
These power plugs are connected easily by simply inserting the white plug of the white junction box
cover into the correct plug-in connection (3) in the junction box.
Example below: L1 to L1 (left wall panel power connection) (left wall panel junction box)
Fitting the junction box covers: After the junction box has been connected securely fix the junction
box cover with a Phillips screwdriver and 2 Phillips screws from Box 1.
Page 3

Floor panel (Box 1): Put the floor panel on a level surface 8-16 cm from the wall panel and no more
than 152 cm away from a 230V socket.
Position the floor panel in such a way that the slot for the glass section is at the front of the sauna.
Note: Put the ceiling, bench valance and bench aside until the corresponding steps.
Rear wall panel (2 sections):
•Place the left back wall panel section into the left hand slot.
•Place the right back wall panel section into the right hand slot.
•Lift both back wall panel sections at the same time.
Note – Put the front wall panel aside until the “Front wall panel” section.
Page 4

Right wall panel:
•Place the right wall
panel into the right
hand slot in the floor
panel.
•Attach the back wall
panel to the right wall
panel by lifting the
right panel and
pushing it into the
retaining bracket on
the back panel.
Left wall panel:
•Place the left
panel into the
left hand slot in
the floor panel.
•Attach the back
wall panel to the
left wall panel by
lifting the left
panel and
pushing it into
the retaining bracket on the back panel.
Bench valances:
Insert the bench
valances between the
back and side wall
panel sections.
Slide the fan component
(Box1) into the retaining
device on the bench
valance.
Connect the white
connector on the black
junction box to the white
connector on the fan.
Secure both valances:
Connections:
•Connect all connections inside the valance area.
•All letters and numbers must match. See the pictures on page 3 for an explanation of this.
•Note – this sauna model includes an optional third bench.
•Note – the 3rd bench doesn't heat up the valance or the top of the bench but offers additional
facilities for sitting or lying down if required.
•Note: When using two benches the inside
of your sauna should look like this.
•When using 3 benches the inside of your
sauna should look like this.
Page 5

Black main junction box: (2) connections
Locate the black main junction box that is fixed to the internal floor of the sauna.
1 Insert the 24 pin, multicoloured cable plug into the left hand side of the main junction box.
See point 3 -
Input/output
2 The ON/ OFF switch is on the right hand side of the main junction box.
Set the switch as shown above to the ON (EIN) position.
3 Connect the loudspeaker input and output.
Note – Do NOT insert the 230 volt alternating current cable into the socket yet.
Bench:
•Push the bench seat down onto the right and left wall panel.
•Tilt the bench against the back panel as shown below.
•Connect the S-1 electrical connector to the S-1 junction box.
•Fix the cover of the S-1 junction box with 2 Phillips screws.
•Connect the low voltage LED connector to each bench.
•Lay the bench down and push it into the right place.
Front wall panel:
•Insert the front left glass section into the slot provided.
(Note: The seal should be in the middle and on the inside of the sauna.)
•Two adults are required to push the right fixed component into the front right hand slot.
Page 6

•The person who is holding the door will have to help fit the section into the floor and side panel.
•When the section is securely attached to the floor and side wall panel you are ready for the ceiling
section.
Note: If additional helpers are not available to hold the glass components while two people fix
the ceiling section, fix the whole front with adhesive tape.
Ceiling:
•Lift the ceiling up and place it carefully on the four (4) wall
panels as shown below.
•Note: Ensure that the electrical connections are placed
through the ceiling and are not disconnected when you put
the ceiling into position slowly.
•Tip: To make it easier to pull cables through the ceiling
slot, you can take small styropor blocks and put them in
several places between the ceiling and the wall panels so
that the ceiling stays put. When the cables have been
pulled through, remove the styropor blocks and lower the ceiling onto the wall panels.
•Fit the front glass sections into the ceiling slot.
•Using a step ladder, open the flaps in the ceiling and turn the wooden support 90º. This fixes
the ceiling securely onto the wall panels and ensures that the door panel cannot fall out.
Page 7

A dipole radio antenna is supplied with your infrared sauna for better
FM reception.
You will find the dipole antenna in the bag in the installation manual.
1. Take the dipole antenna (black wires) out of the bag in the installation
manual.
2. Open the cover on the top of the ceiling above the touch screen.
3. Connect the dipole antenna to the wire marked 7
4. Spread the wire out and pull it apart to improve FM radio reception.
Ceiling to the rear wall panel: (2) connections:
Lift the door panel at the top left of the rear external
face of the ceiling. You will see 4 connections
labelled 1 – 4.
Fix each ceiling connection 1 – 4 to the
corresponding number.
Ensure that they are connected securely to each
other. After connecting close the ceiling flap.
Connection between the ceiling and front wall panel:
•Lift the flap on the top of the ceiling.
You will see four connections.
Note: Connect white to black on the two black
and white cables.
•Connect the other 2 connections matching the
colours.
•Numbered 5, 6, 7 & 8. Connect numbers 5 – 8
to 5 – 8.
•Close the front ceiling flap.
Page 8

De luxe door handles:
Inside Outside
Your infrared sauna is now ready for use.
------------------------------------------------------------------------------------------------------------------------------------------------
Page 9

Control panel instructions:
Main current: Press POWER to turn the sauna ON (AN) or OFF (AUS). If a red light comes on the sauna
is ON. If it is white the sauna is OFF.
Timer functions: Press and hold down or in order to set the running time. You can
also run your finger up or down the timer to set it.
Timer 2: Use this function with a pre-setting of up to 24 hours to set the sauna to come on later.
Temperature functions:
1. Press to switch between Cand F. C or F will light up to show the required units.
2. Press and hold or to set the required temperature.
Pressing once will increase or reduce the setting in one degree intervals. You can also run your finger
over the temperature bar.
The central temperature display shows the actual sauna temperature.
3. Press to set the bench/ leg/ floor heat to ON or OFF. Red waves can be seen in heating mode
and white ones in OFF mode.
Light functions:
1. Press Inside light to switch it ON or OFF.
2. Note: Outside light ON or OFF will not work with S series models.
Colour therapy functions:
Press the colour therapy light in order to activate coloured light or a colour sequence. The sequence
is shown in detail below:
1. Press – RED
2. Press – RED-GREEN
3. Press – GREEN
4. Press – BLUE-GREEN
5. Press – BLUE
Page 10

6. Press – BLUE-RED
7. Press – BLUE-RED-GREEN
8. Press – Activates the full rotation of all the 7 aforementioned colour therapies one after the other.
9. Press – Turns the colour therapy functions OFF.
Note: The colour of the light is indicated by the waves around the bulb symbol.
How to operate the radio and MP3 player
Press the radio icon to switch to radio mode.
Internal reception (only FM) varies. You can use USB,
micro SD or audio cable for MP3. You will have to use an
audio cable from your device for Apple products.
Loudspeakers are hidden sound generators. Some MP3
versions or other audio files can't be played back in the
USB or micro SD slot.
Troubleshooting tips:
a. Main control panel lights not lit up:
Check the electrical connections between the ceiling and the back panel and the front panel.
Ensure that the plug is correctly connected to the socket and the switch.
Ensure that the main switch (house) is not switched off (socket has power).
Ensure that the main control switch (under the bench) is not switched off and is ON.
b. The sauna does not heat up:
Ensure that the power cable is correctly inserted into the socket.
Ensure that all junction boxes are correctly connected under the bench as shown in the junction box
connection code in 4a.
Ensure that the main switch (house) is not switched off (socket has power).
Ensure that the main control switch (under the bench) is not switched off and is ON.
Ensure that the required temperature is higher than the actual sauna temperature.
(Control needs heat)
-------------------------------------------------------------------------------------------
Page 11

Wiring Diagram
Page 12

Infravärmekabin för fyra personer
Prime+ 1814
Användarinstruktioner
Anm.: Kabinen måste installeras på en plan, jämn yta.
Försiktighetsåtgärder innan kabinen tas i drift
2
Information om förmonteringen
2
Elkrav
2
Montera kabinen
3
Anslutningar i fördelningslådan
3
Anslutningar i huvudfördelningslådan
5
Elanslutningar i taket
7
Instruktioner för kontrollpanelen
10
Belysning: inne/ute/färgterapi
10
Underhåll och teknisk support
11
Kopplingsschema
12
121210
Sidan 1

Försiktighetsåtgärder innan kabinen tas i drift: Varning (konfigurera och använda utrymmet):
•Riktig elektrisk jordning krävs
•Det är inte tillåtet att montera elkopplingar inuti kabinen
•Värmelementen får inte komma i kontakt med vatten
•Montera inte lås eller regel på dörren
•Blockera inte ventilationsöppningarna
•Barn får inte lämnas utan uppsyn i värmekabinen
•Rengör värmekabinen med en fuktig trasa
•Det är inte tillåtet att rengöra kabinen med ångrengöraring, högtrycksrengöring eller genom att spruta
av den med vatten
Varning: Anslut inte kabinens kontakten till elnätet förrän monteringen är helt slutförd!
Varning (hälsorelaterade begränsningar):
•Om du är utsatt för förhöjda temperaturer över längre tid kan det leda till hypertermi (att kroppstemperaturen
ligger flera grader över 37 °C)
•Symtom på hypertermi är bland annat: yrsel, håglöshet, medtagenhet och svimning. Effekter av hypertermi:
oAnvändaren förstår inte att det är nödvändigt att lämna infrakabinen
oFosterskador hos gravida
oFysisk oförmåga att lämna utrymmet
oMedvetslöshet
•Obs! Med intag av alkohol eller droger ökar risken för dödlig hypertermi
•Om du har hälsoproblem eller sjukdomar bör du rådfråga läkare innan du använder värmekabinen
•Avbryt användningen direkt om du känner dig nervös, skakig, får huvudvärk, blir illamående eller kräks
•Personer som lider av hypertermi eller av hjärt-kärlsjukdom bör rådfråga läkare innan de använde
infravärmekabinen
•Använd inte värmekabinen om du har druckit alkohol eller tagit lugnande medel, eller om värme leder till
smärtor
•Vi rekommenderar inte att du använder infravärmekabinen om du under det senaste dygnet varit utsatt för
UV-strålning (om du solat ute eller i solarium)
•Om du upptäcker ovanliga hudförändringar efter att ha använt infravärmekabinen, till exempel långvarigt
erytem (hudrodnad som kvarstår mer än en dag) eller nätartade färgförändringar, ska du avbryta
användningen och rådfråga läkare
Varning (brandfara):
•Använd inte värmekabinen för att torka kläder, baddräkter eller liknande
•Häng inte upp handdukar eller andra föremål på eller framför infravärmestrålaren
•Anslut aldrig infrakabinen med skadad kabel eller skadad kopplingsdosa
Information om förmonteringen:
a. Det krävs två (2) vuxna för monteringen och installationen av kabinen.
b. Monteringsverktyg: Stjärnskruvmejsel
c. Kartongerna är markerade efter monteringsföljden för kabinen
d. Anm.: Glaset som monteras på kabinens front är tungt och kan gå sönder.
Kartong 1: Golv, tak, bänkbeklädnad, fläktkomponent och instruktionsbok
Förpackning om 10 philipsskruvar för förgreningsdosornas lock
En uppsättning dörrhandtag
Kartong 2: Bakre och främre vägg
Kartong 3: Vänster och höger vägg
Elkrav: Infravärmekabinen är tillverkad för anslutning till 230 volt.
Sidan 2

Monteringssteg för värmekabinen:
Anmärkning – det finns (12) elanslutningar i bastun.
Anmärkning – det finns (12) elanslutningar i bastuns tak.
(12) Befinner sig i kabinen: Bakre vägg, vänster och höger vägg, bänkbeklädnad, fläkt under
bänkbeklädnad, bänk samt huvudnätanslutning
(12) Elanslutningarna befinner sig på taket övre yttersida
(1) Kabinens nätanslutningskabel: Anslut INTE värmekabinens huvudströmledning till
elnätet förrän samtliga monteringssteg är korrekt genomförda.
------------------------------------------------------------------------------------------------------------------------------------------------
Det finns (12) elanslutnings-/förgreningsdosor som är markerade och som ska anslutas efter monteringen
av varje del.
Bakre vägg vänster höger bänkbeklädnad bänk
B1 till B1 L1 till L1 R1 till R1 S3 till S3 S1 till S1
B2 till B2 L2 till L2 R2 till R2 S4 till S4 S2 till S2
Dessa kopplingar är lätta att göra. Den vita kontakten från den vita förgreningsdosans lock ansluts till
passande instickningsanslutning (3) i förgreningsdosan.
Exempel nedan: L1 till L1 (elanslutning vänster vägg) (förgreningsdosa vänster vägg)
Montera förgreningsdosornas lock: När en säker anslutning till förgreningsdosan är gjord fäster
du förgreningsdosans lock med en stjärnskruvmejsel och 2 philipsskruvar från kartong 1.
Sidan 3

Golvplatta (kartong 1): Placera golvplattan på en jämn yta, 8–16 cm från väggen och högst 152 cm från ett
230 volts eluttag.
Placera golvplattan så att spåren för glaselementen är riktade framåt.
Anm.: Ställ undan tak, bänkbeklädnad och bänk tills du kommer till motsvarande steg.
Bakre vägg (2 element):
•Placera den bakre väggens vänstra element i det vänstra spåret
•Placera den bakre väggens högra element i det högra spåret
•Lyft båda väggelementen samtidigt.
Anmärkning – Ställ undan den främre väggen tills du kommer till avsnittet ”Främre vägg”.
Sidan 4

Höger vägg:
•Placera den högra
väggen i golvplattans
högra spår
•Foga samman den
bakre väggen med
den högra väggen
genom att lyfta den
högra väggen och
skjuta in den i den
bakre väggens
hållklammer.
Vänster vägg:
•Placera den
vänstra väggen
i golvplattans
vänstra spår
•Foga samman
den bakre
väggen med den
vänstra väggen
genom att lyfta
den vänstra
väggen och skjuta in den i den bakre
väggens hållklammer.
Bänkbeklädnader:
Placera
bänkbeklädnaderna
mellan det bakre
väggelementet och
sidoväggselementen
Låt fläktkomponenten
(kartong 1) glida in i hållaren
i bänkbeklädnaden.
Anslut den vita kontakten
från den svarta
förgreningsdosan till
fläktens vita kontakt.
Fäst båda beklädnader.
Anslutningar:
•Koppla samman alla anslutningar i beklädnadsområdet
•Alla bokstäver och siffror måste stämma överens. För en förklaring i bilder, se sidan 3.
•Anmärkning – till denna bastumodell finns alternativet att montera en tredje bänk.
•Anmärkning – den tredje bänken värmer varken upp beklädnad eller ovansida av bänken,
utan ger ytterligare sitt- eller liggplatser om sådana önskas.
•Anm.: Om två bänkar används ska
bastuns inre se ut så här.
•Om tre bänkar används ska bastuns inre
se ut så här.
Svart huvudfördelningslåda: (2) anslutningar
Leta reda på den svarta huvudfördelningslådan som sitter fast
i värmekabinens innergolv.
Sidan 5

1: Anslut den 24-poliga, flerfärgade kabelkontakten till huvudfördelningslådans vänstra sida
Se punkt 3 –
Input/Output
2: På huvudfördelningslådans högra sida finns en huvudströmbrytare (ON-OFF).
Ställ strömbrytaren enligt bilden ovan i läget PÅ (ON).
3: Anslut högtalarna till Input och Output.
Anmärkning – Stick INTE ÄN in kontakten i eluttaget (230 volt)!
Bänk:
•Skjut ned bänksitsen mot den högra och vänstra väggen.
•Tippa bänken mot den bakre väggen enligt illustreringen nedan.
•Anslut förgreningsdosan S-1 till fördelarlådan S-1.
•Säkra S-1-fördelningslådans lock med två philipsskruvar.
•Anslut lågspännings-LED-anslutningen på respektive bänk.
•Lägg ned bänken och skjut den på plats.
Främre vägg:
•Skjut in det vänstra, främre glaselementet i avsett spår
(Anm.: Tätningsplattan ska befinna sig i mitten och på utrymmets insida.)
•För att skjuta in det högra fasta elementet i det högra, främre spåret krävs att två vuxna hjälps åt.
Sidan 6

•Den person som håller fast i dörren måste hjälpa till att passa in elementet i golv och sidovägg.
•När elementet sitter säkert mot golv och sidovägg är det dags för takelementet.
Anm.: Om det inte finns ytterligare personer som kan hjälpa till för att hålla glaselementen under
tiden som två personer sätter takelementet på plats måste hela fronten fixeras med kraftig tejp.
Tak:
•Lyft taket och placera det försiktigt på de fyra (4)
väggarna enligt bilden nedan
•Anm.: Se till att elanslutningarna dras genom taket och
inte blir klämda när ni långsamt för taket på plats
•Tips: För att göra det enklare att dra kablar genom
takspåret kan du lägga små frigolitblock på flera ställen
mellan tak och väggar för att ha taket förberett på plats.
När kablarna har dragits igenom tar ni bort frigolitblocken
och sänker ned taket på väggarna.
•Passa in de främre glaselementen i takspåret
•Använd en trappstege för att nå upp och öppna luckorna på taket och vrid träblocket 90 grader.
Detta fäster taket säkert till väggarna och ser till att dörrpanelen inte kan ramla ut.
Sidan 7

I leveransen av infravärmekabinen ingår en dipolsantenn för att ge bättre
FM-radiomottagning.
Dipolsantennen finns i samma påse som installationshandboken.
1. Ta ut dipolsantennen (svarta ledningar) ur påsen med
installationshandboken
2. Öppna luckan uppe på taket ovanför pekskärmen.
3. Koppla samman dipolsantennen med ledningen med markeringen #7
4. Rulla ut ledningen och dra isär den för att förbättra
FM-radiomottagningen.
Tak på bakre vägg: (2) anslutningar:
Öppna dörrpanelen upptill till vänster på takets bakre
yttersida. Här finns fyra anslutningar som är markerade med
siffrorna 1–4.
Fäst respektive takanslutning 1–4 vid motsvarande siffra.
Se till att de är säkert anslutna till varandra. När du har gjort
anslutningarna stänger du luckan i taket.
Anslutning mellan tak och främre vägg:
•Öppna luckan på takets ovansida.
Här finns fyra anslutningar.
Anm.: Koppla samman vit och svart på de två
svarta och vita kablarna
•Koppla samman de andra två anslutningarna efter
respektive färg.
•De är numrerade 5, 6, 7 och8. Koppla samman
nummer 5–8 med 5–8.
•Stäng den främre luckan i taket.
Sidan 8
Other manuals for Prime+ 1814
1
Table of contents
Languages:
Other Tylo Sauna manuals