UNIVIEW IPSAN Series User manual

IPSANSeries
NetworkStorageSystem
QuickGuide
ManualVersion:P101‐20140630

©2014,ZhejiangUniviewTechnologiesCo.,Ltd.anditslicensors
AllRightsReserved
Nopartofthismanualmaybereproducedortransmittedinanyformorbyanymeanswithoutprior
writtenconsentofZhejiangUniviewTechnologiesCo.,Ltd.
Notice
Theinformationinthismanualissubjecttochangewithoutnotice.Everyefforthasbeenmadein
thepreparationofthismanualtoensureaccuracyofthecontents,butallstatements,information,
andrecommendationsinthismanualdonotconstitutethewarrantyofanykind,expressorimplied.
EnvironmentalProtection
Thisproducthasbeendesignedtocomplywiththeenvironmentalprotectionrequirements.The
storage,use,anddisposalofthisproductmustmeettheapplicablenationallawsandregulations.
Preface
Audience
Thisdocumentisintendedfor:
zAdministratorsinchargeofinstallingthesystemandconfiguringservices
zOnsitetechnicalsupportandmaintenancepersonnel
zUsersinchargeofproductserviceoperations
Convention
FormatDescription
NOTE!Indicatesspecialoperationsorinformationrequiredforconfiguringthe
devicesuccessfully.
CAUTION!Mindtheoperationprecautions.Improperoperationsmaycausedatalossor
devicedemage.
SafetyandComplianceInformation
ConventionsUsedSymbol
Thesymbolsinthischapterareshowninthefollowingtable.Theyareusedtoremindthereaderof
thesafetyprecautionsduringequipmentinstallationandmaintenance.

Safety Symbol Description
Generic alarm symbol: To suggest a general safety concern.
ESD protection symbol: To suggest electrostatic-sensitive equipment.
Electric shock symbol: To suggest a danger of high voltage.
SafetyInformation
WARNING!
Installationandremovaloftheunitanditsaccessoriesmustbecarriedoutbyqualifiedpersonnel.
YoumustreadalloftheSafetyInstructionssuppliedwithyourequipmentbeforeinstallationand
operation.
Warnings:
zIftheproductdoesnotworkproperly,pleasecontactyourdealerorthenearestservicecenter.
(Weshallnotassumeanyresponsibilityforproblemscausedbyunauthorizedrepairor
maintenance.)
zToreducetheriskoffireorelectricalshock,donotexposethisproducttorainormoisture.
zThisinstallationshouldbemadebyaqualifiedservicepersonandshouldconformtoallthe
localcodes.
zPleaseinstallblackoutsequipmentintothepowersupplycircuitforconvenientsupply
interruption.
zTheseparateearthingterminalmustbepermanentlyconnectedtoearth.
zForACsuppliedmodel:Theplug‐socketcombinationmustbeaccessibleatalltimesasitserves
asthemaindisconnectingdevice.
zBeforethepowercableisinstalledorremoved,thepowermustbeturnedoff.
zToavoidheataccumulation,goodventilationisrequiredforaproperoperatingenvironment.
zImproperuseorreplacementofthebatterymayresultinhazardofexplosion.Pleaseusethe
manufacturerrecommendedbatterytype.
Caution:Fiberopticports–opticalsafety.
Neverlookatthetransmitlaserwhilethepowerison.Neverlookdirectlyatthefiberportsand
thefibercableendswhentheyarepoweredon.
Caution:Useofcontrolsoradjustmentstotheperformanceorproceduresotherthanthose
specifiedhereinmayresultinhazardouslaseremissions.

RegulatoryCompliance
FCCPart15
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfordigitaldevice,pursuantto
part15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful
interferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipment
generates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructionmanual,maycauseharmfulinterferencetoradiocommunications.Operationof
thisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwill
berequiredtocorrecttheinterferenceathisownexpense.
ThisproductcomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo
conditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
LVD/EMCDirective
ThisproductcomplieswiththeEuropeanLowVoltageDirective2006/95/ECandEMCDirective
2004/108/EC.
WEEEDirective–2002/96/EC
TheproductthismanualreferstoiscoveredbytheWasteElectrical&ElectronicEquipment(WEEE)
Directiveandmustbedisposedofinaresponsiblemanner.

i
Contents
1ProductIntroduction∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙1
2HardwareInstallation∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2
ToolReference∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2
EnvironmentRequirements∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2
Incorrectinstallationmanner∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙3
Correctinstallationsteps∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4
Connectcablesandperformverification∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
3SoftwareConfiguration∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
BasicConcepts∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
ConfigurationWorkflow∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
Logintothedevicethroughthemanagementnetworkport∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
SettheIPaddressoftheserviceport∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
CreateaRAIDgroup∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9
CreateaRAIDLUN∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙11
Createlogicalresources∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙12
Createatargetandaddaninitiator∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙13
AssignSANresources∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙16
Configuretheinitiator(withWindowsclientasanexample)∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙17
Viewdisksassigned(withWindowsXPasanexample)∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙18

1ProductIntroduction
IPSANSeriesstoragehostsincludefourtypesofproducts:singlecontrolwith24diskslots,singlecontrolwith
16diskslots,singlecontrolwith48diskslotsanddualcontrolwith24diskslots.
ThestorageproductsupportsthreetypesofDEUs:singlecontrolDEUswith24diskslots,singlecontrolDEUs
with48diskslotsanddualcontrolDEUswith24diskslots.
FordetailsaboutthesupportedDEUs,seethetablebelow.
Table1‐1DifferentproductssupportdifferentDEUs
SeriesSCUdiskslotsDEUdiskslots
IPSANSeries
24diskslots(singlecontrol)24diskslots(singlecontrol)
16diskslots(singlecontrol)24diskslots(singlecontrol)
48diskslots(singlecontrol)24diskslotsand48diskslots(bothsinglecontrol)
24diskslots(dualcontrol)24diskslots(dualcontrol)
NOTE!
Thismanualtakesthesinglecontrolwith24diskslotsforexample.Formoredetails,seetheOnlineHelp
whichisreleasedwiththesoftware.MethodtochecktheOnlineHelp:click<Help>buttonontheGUI.
Thefollowingillustrationsareonlyforyourreference.Thelatestversionshallprevailintheactualsituation.
1

2HardwareInstallation
ToolReference
EnvironmentRequirements
TemperatureRequirement
Operatingtemperature0°C~40°C
Recommended:10°C~35°C
Storagetemperature
Excludingbatterymodules:–20°C~+60°C
Includingbatterymodules:–15°C~+40°C(storagewithin1month);
10°C~35°C(storageover1month)
HumidityRequirement
Operatinghumidity20%to80%(non‐condensing)
Storagehumidity10%to90%(non‐condensing)
NOTE!
Corrosivegasesanddustcancausedamagetoharddisks.Fordetailedrequirementsabouttheequipment
roomenvironment,pleaserefertoCheckingtheInstallationEnvironmentssectioninOnlineHelpshipped
withtheproduct.
2

Incorrectinstallationmanner
CAUTION!
Wheninstallingadevice,ensurethatthedeviceandthemarklineonthesquareholestriponthecabinet
areproperlyalignedin1U.Otherwise,youarenotallowedtoinstalltherack‐mountingearscrews.
Iftherack‐mountingearscrewsareforciblyinstalledwithoutthealigningprocedure,agapexistsbetween
thedeviceandthetrayandthedeviceishangingoverthesquareholestrip.Consequently,thedeviceis
unstable,therebyaffectingstabilityoftheharddisks.Iftheharddisksarerunningforalongtimeinsuch
situation,manyproblems,suchasahighread‐and‐writeerrorrateandahighdamagerate,willarise.
Figure1:Thetrayisinstalledhalf‐Udownward.
Figure2:Therack‐mountingearisnotallignedproperly.
Figure3:ThedeviceisnotallignedinoneUandishangingovertherack‐mountingearafterthescrewsare
installed.
Figure4:Agapexistsbetweenthedeviceandthetray.
3

Correctinstallationsteps
4

Connectcablesandperformverification
5

6

7
3SoftwareConfiguration
BasicConcepts
BasicConceptDescription
ConsoleIndicatestheGraphicalUserPort(GUI)usedinconfigurationandmanagement.
ServerIndicatesIPSANseriesintheconsole.
Management
workstation
IndicatesthePCwheretheconsoleisinstalled.
RAIDGroupIndicatesalogicalentityconsistsofmultiplephysicalharddisks.Inaddition,thelogicalentitypossesses
RAIDlevelfeatures.RAIDindicatesredundantarrayofindependentdisks.
ThelogicalentityisusedtoformtheRAIDofaspecifiedlevelandprovidephysicalresourcesforRAID
LogicalUnitNumbers(LUNs).
RAIDLUNComparedwithaLUN,aRAIDLUNindicatesasmallerlogicalentitycreatedinaRAIDgroup.
AfteraRAIDLUNiscreatedinaRAIDgroup,theRAIDLUNdirectlyinheritstheRAIDleveloftheRAID
group.
Logical
resource
IndicatesalogicalentitythatiscreatedonaRAIDLUNfordirectaccessfromaclient.
AclientcanaccessalogicalresourceafteritiscreatedonbasisofaRAIDLUNandassignedtoatarget.
InitiatorIndicatesanentitythatinitiatesanInternetSmallComputerSystemPort(iSCSI)request.
TargetIndicatesanentitythatrespondstoaniSCSIrequest.Aninitiatorcaninitiatearequesttoatargetonly
afteritisassociatedwiththetarget.
Management
networkport
Configuresandadministratesdevices,100Mbit/s.
ServiceportTransfersdata,1000Mbit/s.
ConfigurationWorkflow
Tocompletemostbasicconfigurations,performthefollowingoperationsonthestoragesoftwareGUI:
1.Logintothedevicethroughthemanagementnetworkport.
2.SettheIPaddressoftheserviceport.
3.CreateaRAIDgroup.
4.CreateaRAIDLUN.
5.Createlogicalresources.

6.Createatargetandaddaninitiator.
7.AssignStorageAreaNetwork(SAN)resources.
8.Configuretheinitiator(withWindowsclientasanexample).
9.Viewdisksassigned(withWindowsXPasanexample)
Logintothedevicethroughthemanagementnetworkport
Enter http://192.168.0.1inthebrowseraddressbarofthemanagementworkstation,downloadtheconsole,
andlogintotheconsole.Bydefault,theusernameisadmin,thepasswordispassword,andtheserverIP
address 192.168.0.1.
Figure3‐1
SettheIPaddressoftheserviceport
1. ChooseServerMaintenance>ConfigureNetwork.
2. ChangetheIPaddressoftheserviceport.
ThedefaultIPaddressesoftheserviceportsare10.1.1.1and10.1.2.1.
Ifexpansionboardsareinserted,thecorrespondingdefaultIPaddressesare10.1.3.1,10.1.4.1,10.1.5.1and
10.1.6.1.
8

Figure3‐2ChangetheIPaddress
3. Click<OK>.
CreateaRAIDgroup
1. ChooseRAIDGroupResources>LocalRAIDGroup>Create.
2. CreateaRAIDgroup.
Checkwhetherthenumberofdisksunder"PhysicalResources"isconsistentwiththeactualnumber.
Recommendnumberofdisks:11(RAID5)+1(hotstandby)+11(RAID5)+1(hotstandby)
Or:11(RAID5)+12(RAID5)+1(hotstandby).
9

Figure3‐3CreateaRAIDGroup
3. (Optional)Click<Next>.ConfirmtheinformationoftheRAIDGroup.
10

Figure3‐4TheinformationoftheRAIDLUN
4. Click<Finish>.
CreateaRAIDLUN
IfnoRAIDLUNhasbeencreatedwhenyoustarttocreateaRAIDGroup,followthesestepstocreateone.
1. ChooseRAIDLUNResources>LocalRAIDLUNs>Create.
2. Enterthename.SelectthecorrespondingRAIDgroup.
SizeofRAIDgroupisdisplayedautomatically.
11

Figure3‐5CreateaRAIDLUN
3. Click<OK>.
Createlogicalresources
1. ChooseLogicalResources>SANResources>Create.
2. SettheSANresourcenameandsize,andselectitsRAIDLUN.
12

Figure3‐6CreatetheSANResource
3. SettheSANresourcenameandsize,andselectitsRAIDLUN,thenClick<OK>.
Createatargetandaddaninitiator
1. ChooseTargetResources>Create.
2. DeselectAutoAllocated,andcustomizethename.SelecttheIPaddressofthetarget,thenclick<Next>.
13

Figure3‐7Createatarget
3. Click<Add>toaddaninitiator.
Figure3‐8Addaninitiator
4. Setthenameoftheinitiator,thentoclick<OK>.
14

Figure3‐9Setthenameoftheinitiator
5. Confirmtheresult,thentoclick<Finish>.
Figure3‐10 Confirm
15
Table of contents
Popular Storage manuals by other brands

Teac
Teac DV-W50PUK Quick installation guide

S&C
S&C PureWave SMS-250 Installation

Hitachi
Hitachi DKC-F710I-1R6FM quick start guide

SanDisk
SanDisk Cruzer USB Flash Drive quick start guide

DataDirect Networks
DataDirect Networks SFA12Ki Installation & configuration guide

Dell
Dell PowerVault 110T SDLT320 user guide

THOMSON
THOMSON Grass Valley K2 ASI Media Client quick start guide

IBM
IBM SAN768B-2 Installation, service and user guide

Seagate
Seagate Exos AP 2U12-B instruction manual

Seagate
Seagate Enterprise Capacity 2.5 HDD Constellation product manual

Addonics Technologies
Addonics Technologies REDESP? REDESPU3 user guide

YearGoo
YearGoo 2.5” Solid State Drive manual