UNIVIEW IPSAN Series User manual

IPSANSeries
NetworkStorageSystem
QuickGuide
ManualVersion:P101‐20140630

©2014,ZhejiangUniviewTechnologiesCo.,Ltd.anditslicensors
AllRightsReserved
Nopartofthismanualmaybereproducedortransmittedinanyformorbyanymeanswithoutprior
writtenconsentofZhejiangUniviewTechnologiesCo.,Ltd.
Notice
Theinformationinthismanualissubjecttochangewithoutnotice.Everyefforthasbeenmadein
thepreparationofthismanualtoensureaccuracyofthecontents,butallstatements,information,
andrecommendationsinthismanualdonotconstitutethewarrantyofanykind,expressorimplied.
EnvironmentalProtection
Thisproducthasbeendesignedtocomplywiththeenvironmentalprotectionrequirements.The
storage,use,anddisposalofthisproductmustmeettheapplicablenationallawsandregulations.
Preface
Audience
Thisdocumentisintendedfor:
zAdministratorsinchargeofinstallingthesystemandconfiguringservices
zOnsitetechnicalsupportandmaintenancepersonnel
zUsersinchargeofproductserviceoperations
Convention
FormatDescription
NOTE!Indicatesspecialoperationsorinformationrequiredforconfiguringthe
devicesuccessfully.
CAUTION!Mindtheoperationprecautions.Improperoperationsmaycausedatalossor
devicedemage.
SafetyandComplianceInformation
ConventionsUsedSymbol
Thesymbolsinthischapterareshowninthefollowingtable.Theyareusedtoremindthereaderof
thesafetyprecautionsduringequipmentinstallationandmaintenance.

Safety Symbol Description
Generic alarm symbol: To suggest a general safety concern.
ESD protection symbol: To suggest electrostatic-sensitive equipment.
Electric shock symbol: To suggest a danger of high voltage.
SafetyInformation
WARNING!
Installationandremovaloftheunitanditsaccessoriesmustbecarriedoutbyqualifiedpersonnel.
YoumustreadalloftheSafetyInstructionssuppliedwithyourequipmentbeforeinstallationand
operation.
Warnings:
zIftheproductdoesnotworkproperly,pleasecontactyourdealerorthenearestservicecenter.
(Weshallnotassumeanyresponsibilityforproblemscausedbyunauthorizedrepairor
maintenance.)
zToreducetheriskoffireorelectricalshock,donotexposethisproducttorainormoisture.
zThisinstallationshouldbemadebyaqualifiedservicepersonandshouldconformtoallthe
localcodes.
zPleaseinstallblackoutsequipmentintothepowersupplycircuitforconvenientsupply
interruption.
zTheseparateearthingterminalmustbepermanentlyconnectedtoearth.
zForACsuppliedmodel:Theplug‐socketcombinationmustbeaccessibleatalltimesasitserves
asthemaindisconnectingdevice.
zBeforethepowercableisinstalledorremoved,thepowermustbeturnedoff.
zToavoidheataccumulation,goodventilationisrequiredforaproperoperatingenvironment.
zImproperuseorreplacementofthebatterymayresultinhazardofexplosion.Pleaseusethe
manufacturerrecommendedbatterytype.
Caution:Fiberopticports–opticalsafety.
Neverlookatthetransmitlaserwhilethepowerison.Neverlookdirectlyatthefiberportsand
thefibercableendswhentheyarepoweredon.
Caution:Useofcontrolsoradjustmentstotheperformanceorproceduresotherthanthose
specifiedhereinmayresultinhazardouslaseremissions.

RegulatoryCompliance
FCCPart15
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfordigitaldevice,pursuantto
part15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful
interferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipment
generates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructionmanual,maycauseharmfulinterferencetoradiocommunications.Operationof
thisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwill
berequiredtocorrecttheinterferenceathisownexpense.
ThisproductcomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo
conditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
LVD/EMCDirective
ThisproductcomplieswiththeEuropeanLowVoltageDirective2006/95/ECandEMCDirective
2004/108/EC.
WEEEDirective–2002/96/EC
TheproductthismanualreferstoiscoveredbytheWasteElectrical&ElectronicEquipment(WEEE)
Directiveandmustbedisposedofinaresponsiblemanner.

i
Contents
1ProductIntroduction∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙1
2HardwareInstallation∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2
ToolReference∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2
EnvironmentRequirements∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2
Incorrectinstallationmanner∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙3
Correctinstallationsteps∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4
Connectcablesandperformverification∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
3SoftwareConfiguration∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
BasicConcepts∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
ConfigurationWorkflow∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
Logintothedevicethroughthemanagementnetworkport∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
SettheIPaddressoftheserviceport∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
CreateaRAIDgroup∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9
CreateaRAIDLUN∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙11
Createlogicalresources∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙12
Createatargetandaddaninitiator∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙13
AssignSANresources∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙16
Configuretheinitiator(withWindowsclientasanexample)∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙17
Viewdisksassigned(withWindowsXPasanexample)∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙18

1ProductIntroduction
IPSANSeriesstoragehostsincludefourtypesofproducts:singlecontrolwith24diskslots,singlecontrolwith
16diskslots,singlecontrolwith48diskslotsanddualcontrolwith24diskslots.
ThestorageproductsupportsthreetypesofDEUs:singlecontrolDEUswith24diskslots,singlecontrolDEUs
with48diskslotsanddualcontrolDEUswith24diskslots.
FordetailsaboutthesupportedDEUs,seethetablebelow.
Table1‐1DifferentproductssupportdifferentDEUs
SeriesSCUdiskslotsDEUdiskslots
IPSANSeries
24diskslots(singlecontrol)24diskslots(singlecontrol)
16diskslots(singlecontrol)24diskslots(singlecontrol)
48diskslots(singlecontrol)24diskslotsand48diskslots(bothsinglecontrol)
24diskslots(dualcontrol)24diskslots(dualcontrol)
NOTE!
Thismanualtakesthesinglecontrolwith24diskslotsforexample.Formoredetails,seetheOnlineHelp
whichisreleasedwiththesoftware.MethodtochecktheOnlineHelp:click<Help>buttonontheGUI.
Thefollowingillustrationsareonlyforyourreference.Thelatestversionshallprevailintheactualsituation.
1

2HardwareInstallation
ToolReference
EnvironmentRequirements
TemperatureRequirement
Operatingtemperature0°C~40°C
Recommended:10°C~35°C
Storagetemperature
Excludingbatterymodules:–20°C~+60°C
Includingbatterymodules:–15°C~+40°C(storagewithin1month);
10°C~35°C(storageover1month)
HumidityRequirement
Operatinghumidity20%to80%(non‐condensing)
Storagehumidity10%to90%(non‐condensing)
NOTE!
Corrosivegasesanddustcancausedamagetoharddisks.Fordetailedrequirementsabouttheequipment
roomenvironment,pleaserefertoCheckingtheInstallationEnvironmentssectioninOnlineHelpshipped
withtheproduct.
2

Incorrectinstallationmanner
CAUTION!
Wheninstallingadevice,ensurethatthedeviceandthemarklineonthesquareholestriponthecabinet
areproperlyalignedin1U.Otherwise,youarenotallowedtoinstalltherack‐mountingearscrews.
Iftherack‐mountingearscrewsareforciblyinstalledwithoutthealigningprocedure,agapexistsbetween
thedeviceandthetrayandthedeviceishangingoverthesquareholestrip.Consequently,thedeviceis
unstable,therebyaffectingstabilityoftheharddisks.Iftheharddisksarerunningforalongtimeinsuch
situation,manyproblems,suchasahighread‐and‐writeerrorrateandahighdamagerate,willarise.
Figure1:Thetrayisinstalledhalf‐Udownward.
Figure2:Therack‐mountingearisnotallignedproperly.
Figure3:ThedeviceisnotallignedinoneUandishangingovertherack‐mountingearafterthescrewsare
installed.
Figure4:Agapexistsbetweenthedeviceandthetray.
3

Correctinstallationsteps
4

Connectcablesandperformverification
5

6

7
3SoftwareConfiguration
BasicConcepts
BasicConceptDescription
ConsoleIndicatestheGraphicalUserPort(GUI)usedinconfigurationandmanagement.
ServerIndicatesIPSANseriesintheconsole.
Management
workstation
IndicatesthePCwheretheconsoleisinstalled.
RAIDGroupIndicatesalogicalentityconsistsofmultiplephysicalharddisks.Inaddition,thelogicalentitypossesses
RAIDlevelfeatures.RAIDindicatesredundantarrayofindependentdisks.
ThelogicalentityisusedtoformtheRAIDofaspecifiedlevelandprovidephysicalresourcesforRAID
LogicalUnitNumbers(LUNs).
RAIDLUNComparedwithaLUN,aRAIDLUNindicatesasmallerlogicalentitycreatedinaRAIDgroup.
AfteraRAIDLUNiscreatedinaRAIDgroup,theRAIDLUNdirectlyinheritstheRAIDleveloftheRAID
group.
Logical
resource
IndicatesalogicalentitythatiscreatedonaRAIDLUNfordirectaccessfromaclient.
AclientcanaccessalogicalresourceafteritiscreatedonbasisofaRAIDLUNandassignedtoatarget.
InitiatorIndicatesanentitythatinitiatesanInternetSmallComputerSystemPort(iSCSI)request.
TargetIndicatesanentitythatrespondstoaniSCSIrequest.Aninitiatorcaninitiatearequesttoatargetonly
afteritisassociatedwiththetarget.
Management
networkport
Configuresandadministratesdevices,100Mbit/s.
ServiceportTransfersdata,1000Mbit/s.
ConfigurationWorkflow
Tocompletemostbasicconfigurations,performthefollowingoperationsonthestoragesoftwareGUI:
1.Logintothedevicethroughthemanagementnetworkport.
2.SettheIPaddressoftheserviceport.
3.CreateaRAIDgroup.
4.CreateaRAIDLUN.
5.Createlogicalresources.

6.Createatargetandaddaninitiator.
7.AssignStorageAreaNetwork(SAN)resources.
8.Configuretheinitiator(withWindowsclientasanexample).
9.Viewdisksassigned(withWindowsXPasanexample)
Logintothedevicethroughthemanagementnetworkport
Enter http://192.168.0.1inthebrowseraddressbarofthemanagementworkstation,downloadtheconsole,
andlogintotheconsole.Bydefault,theusernameisadmin,thepasswordispassword,andtheserverIP
address 192.168.0.1.
Figure3‐1
SettheIPaddressoftheserviceport
1. ChooseServerMaintenance>ConfigureNetwork.
2. ChangetheIPaddressoftheserviceport.
ThedefaultIPaddressesoftheserviceportsare10.1.1.1and10.1.2.1.
Ifexpansionboardsareinserted,thecorrespondingdefaultIPaddressesare10.1.3.1,10.1.4.1,10.1.5.1and
10.1.6.1.
8

Figure3‐2ChangetheIPaddress
3. Click<OK>.
CreateaRAIDgroup
1. ChooseRAIDGroupResources>LocalRAIDGroup>Create.
2. CreateaRAIDgroup.
Checkwhetherthenumberofdisksunder"PhysicalResources"isconsistentwiththeactualnumber.
Recommendnumberofdisks:11(RAID5)+1(hotstandby)+11(RAID5)+1(hotstandby)
Or:11(RAID5)+12(RAID5)+1(hotstandby).
9

Figure3‐3CreateaRAIDGroup
3. (Optional)Click<Next>.ConfirmtheinformationoftheRAIDGroup.
10

Figure3‐4TheinformationoftheRAIDLUN
4. Click<Finish>.
CreateaRAIDLUN
IfnoRAIDLUNhasbeencreatedwhenyoustarttocreateaRAIDGroup,followthesestepstocreateone.
1. ChooseRAIDLUNResources>LocalRAIDLUNs>Create.
2. Enterthename.SelectthecorrespondingRAIDgroup.
SizeofRAIDgroupisdisplayedautomatically.
11

Figure3‐5CreateaRAIDLUN
3. Click<OK>.
Createlogicalresources
1. ChooseLogicalResources>SANResources>Create.
2. SettheSANresourcenameandsize,andselectitsRAIDLUN.
12

Figure3‐6CreatetheSANResource
3. SettheSANresourcenameandsize,andselectitsRAIDLUN,thenClick<OK>.
Createatargetandaddaninitiator
1. ChooseTargetResources>Create.
2. DeselectAutoAllocated,andcustomizethename.SelecttheIPaddressofthetarget,thenclick<Next>.
13

Figure3‐7Createatarget
3. Click<Add>toaddaninitiator.
Figure3‐8Addaninitiator
4. Setthenameoftheinitiator,thentoclick<OK>.
14

Figure3‐9Setthenameoftheinitiator
5. Confirmtheresult,thentoclick<Finish>.
Figure3‐10 Confirm
15
Table of contents
Popular Storage manuals by other brands

DANE-ELEC
DANE-ELEC SO MOBILE PLUS quick start guide

SAJ
SAJ HS-5K-S2 user manual

Seagate
Seagate Fast quick start guide

HP
HP LeftHand P4000 - SAN Solutions Application notes

Western Digital
Western Digital WDBACX0010Bxx - My Passport Essential SE Product specifications

Quantum
Quantum Scalar i2000 release note

Seagate
Seagate Momentus 7200.2 Features & benefits

Fujitsu
Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS... Configuration guide

Iomega
Iomega eGo Encrypt quick start guide

Fujitsu
Fujitsu DynaMO 640FE user manual

Quantum
Quantum Scalar i6 quick start

NetApp
NetApp AFF A400 Installation and setup instructions