Fig.1/1
1 Soft Touch handle grip
2 On/Off switch
3 Hose
4 Dirt cup release button
5 Dirt cup assembly
6 Hose handle
7 Cord reel window/ exhaust vent
8 Headlight
9 Nozzle control knob: turn knob
to correct setting for height of carpet
being cleaned
10 Furniture guard: helps prevent cleaner
from marking furniture
11 Brushbar shut-off pedal
12 Brushbar shut-off indicator
13 Exhaust filter access
14 2-in-1tool
15 TurboTool
16 Crevice tool
17 Hose/tool holder
18 Extension wands
19 Cord reel
20 Soft Touch™ wheels
21 Handle release pedal: step on lever to
lower handle to operating or low
positions
22 Cord rewind button: press button to
rewind cord for storage. Hold plug until
cord is rewound
23 Hard Floor Brush (some models only)
PLEASE NOTE: some parts may vary according to model. Please check inside flap of box for more details.
U90-M7 Series User Guide.qxd:UG 16/9/09 15:37 Page 2

3
Vax Careline 0844 412 8455
safety information
2. Safety Information
For Household Use Only
When using the vacuum cleaner, basic safety precautions
should always be observed, including the following:
1. Only use the vacuum cleaner indoors on dry
surfaces.
2. Turn off the vacuum cleaner controls before
connecting or disconnecting from the mains supply.
3. Always unplug the vacuum cleaner before
connecting or disconnecting the vacuum hose and
accessories.
4. This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with
the appliance.
5. Use only as described in this manual.
Use only the manufacturer’s recommended
attachments.
6. Do not use the vacuum cleaner if it has been
dropped, damaged, left outdoors or dropped into
water. Do not use the vacuum cleaner with a
damaged cord or plug. If the supply cord or plug is
damaged, return the vacuum cleaner to a Vax
Authorised Service Agent or suitably qualified
person for examination, repair or adjustment.
7. Do not pull or carry by the cord. Do not use the cord
as a handle, close a door on the cord or pull the
cord around sharp edges or corners. Do not run the
vacuum cleaner over the cord. Keep the cord away
from heated surfaces.
8. Do not handle the plug or vacuum cleaner with wet
hands. Do not use outdoors or on wet surfaces.
9. Do not put any objects into openings. Do not use
with any openings blocked and do not restrict air
flow. Keep all openings free of dust, lint, hair or
anything that may reduce airflow.
10. Keep hair, loose clothing, fingers and all parts of the
body away from openings and moving parts.
11. Do not pick up hot coals, cigarette butts, matches or
any hot, smoking or burning objects.
12. Do not pick up flammable or combustible materials
(lighter fluid, petrol, kerosene, etc) or use in the
presence of explosive liquids or vapours.
13. Do not vacuum up harmful or toxic material (chlorine
bleach, ammonia, drain cleaner, etc).
14. Do not vacuum up hard or sharp objects such as
glass, nails, screws, coins, etc.
15. Do not use without the filters in place.
16. Take extra care when vacuuming on stairs.
17. Keep vacuuming area well lit.
18. Store the vacuum cleaner indoors in a cool, dry area.
19. Turn off the on/off switch before unplugging the
vacuum cleaner.
20. Use only CE-approved 13 amp extension cords.
Non-approved extension cords may overheat. Care
should be taken to arrange the cord so that the
cord cannot be pulled or tripped over.
WA NING: Always switch off and unplug the
vacuum cleaner from the electrical outlet
before assembling, opening or emptying the dirt
container, or before connecting/disconnecting the
attachments.
CAUTION: The vacuum cleaner is a very powerful
unit. Before plugging the cord into the electrical
outlet, make sure the switch is in the ‘off’ position. Hold
the vacuum cleaner firmly when starting and in use.
IMPO TANT: If the inlet, hose or extension tube is
blocked, switch off the vacuum cleaner and
remove the blockage(s) before re-starting the vacuum
cleaner.
IMPO TANT: Cleaning filters regularly improves
vacuum performance. ake sure all filters are
replaced back into the vacuum cleaner before using. This
vacuum cleaner is intended for household use only and
not for commercial or industrial use.
PLEASE KEEP THESE INST UCTIONS FO
FU THE USE.
!
!
!
!
Motor Thermostat
IMPO TANT: The motor is equipped with a
thermal cut-out. If for any reason, the vacuum
cleaner should over-heat, the thermostat will
automatically turn the unit off. Should this occur,
unplug the vacuum cleaner from the electrical outlet
and turn off the switch. Remove the dirt container
and empty. Clean the filters. Allow the cleaner to cool
for approximately one (1) hour. To re-start, plug into
an electrical outlet and switch back on.
!
U90-M7 Series User Guide.qxd:UG 16/9/09 15:37 Page 3

vax.co.uk
4how to assemble
3. How to assemble
Attach Handle
Using a Phillips screwdriver, remove (2) screws from the
top of the upper housing assembly (Fig.3/1).
Insert handle section (A) into upper housing assembly.
Push down firmly until you hear a click (Fig.3/2).
Fasten (2) screws on either side of handle base (Fig.3/3).
Position Tools
Place smaller diameter end of wand (A) into bottom of
holder. Snap wand into clip at top. Repeat with other
wand.
Crevice tool (B) fits into one of the extension wands.
Fit 2-in-1 tool (C) into storage area on side of cleaner as
shown (Fig.3/4).
Fit TurboTool (A) into recessed area on front of cleaner.
Pivot toward handle to snap in place (Fig.3/5).
Fig.3/1
Fig.3/2
Fig.3/3
Fig.3/4
Fig.3/5
A
A
A
B
C
to pre
floorin
NOTE
the br
hard f
U90-M7 Series User Guide.qxd:UG 16/9/09 15:37 Page 4

5
Vax Careline 0844 412 8455
how to operate
4. How to operate
On/Off Switch
Plug cord into electrical outlet. To turn cleaner ON, push
ON/OFF switch once. To turn cleaner OFF, push switch
again (Fig.4/1).
Brushbar Switch
The cleaner is shipped with the brushbar in the OFF
position. To turn the brushbar ON, step on the pedal (A).
The indicator (B) will show red in the “brushbar on”
window (Fig.4/2).
Cord ewind
Grasp the end of the plug and pull to release cord from
cord reel. After desired cord length is reached, the cord
will lock into position.
Pull cord all the way out each time cleaner is used to
avoid heating of cord (Fig.4/3).
NOTE: To prevent cord from whipping, hold plug until
cord is rewound.
Transporting Cleaner
To move your cleaner from room to room, put handle
in upright position, tilt cleaner back on rear wheels and
push forward (Fig.4/4).
Handle Positions
The handle of your cleaner has three positions; upright
for storage and when using cleaning tools; operating
position for general operation on carpet and floors; low
for reaching under low furniture. Step on handle release
lever to lower handle (Fig.4/5).
Fig.4/1
Fig.4/2
Fig.4/4
Fig.4/5
Fig.4/3
A
B
A
1
2
3
WA NING: The brushbar must NOT be rotating
when cleaning hard floors. Switch the brushbar off
to prevent damage to lino, parquet and other hard
flooring.
NOTE: As a precaution, Vax recommends that you raise
the brushbar as well as switching it off for use on lino and
hard floorings.
!
U90-M7 Series User Guide.qxd:UG 16/9/09 15:37 Page 5
Table of contents
Other Vax Bagles Vacuum Cleaner manuals