Viessmann Vitodens 200-W B2HA 88 Instruction manual

Technical Data Manual
VITODENS
r
200-W
5683 718 - 19 09/2020
Model Nos. and pricing: see Price List
Gas-fired wall-mounted condensing boiler
71 to 530 MBH (21 to 155 kW)
Multi-boiler installation 71 to 4240 MBH (21 to 1240 kW)
For Natural Gas and Liquid Propane Gas
Product may not be exactly as shown
Vitodens 200-W
B2HA Series, Models 88, 100, 112, 150, 311, 352, 399, 530
Gas-Fired Wall-Mounted Condensing Boiler with modulating
MatriX cylinder burner for room air independent operation
(using a direct vent system or room air dependent operation).
H

Vitodens 200-W B2HA 88-150, 311- 530 Technical Data
5683 718 - 19
2
Product Information
Vitodens 200-W
The benefits at a glance:
■ Best value in its class with new industry-leading
technology and the most standard features.
■ Highest Efficiency - CSA thermal efficiency rating to
ANSI Z.21.13/CSA 4.9 of 94.5%. Energy Star and the
CSA Energy Performance are not applicable for these
models.
■ Lasting performance with industry-leading Viessmann
made SA240 / S43932 stainless steel Inox-Radial heat
exchanger constructed to CSA B51 and ASME Section IV.
■ Low Emission Combustion with Viessmann made
stainless steel MatriX cylinder burner. Factory calibrated.
■ Fast Installation and Reduced Maintenance with Lambda
Pro, industry-first intelligent combustion management
system: Adjusts automatically to gas type and quality.
No fuel conversion kit required.
■ Powerful and User-friendly
Viessmann Vitotronic on-board multi-function outdoor
reset boiler and system control for multi-temperature
space and DHW heating.
■ Zone circuit capabilities provide 3 input connections that
allow easy integration of third party components such
as thermostats, SIM controls, Multizone controllers, and
other smart or on/off control technologies.
■ The setup of these new capabilities can be done quickly
with the new start-up wizard that prompts the installer
for the relevant information necessary to setup the
system without having to go into complex levels of
coding parameters.
■ The unique capability of the new zone control allows the
installer to combining temperature setpoint operation
and outdoor reset capability. This means that one or all
of the 3 zone circuits control can operate on a set
temperature, or vary based on the outdoor reset curve
that is selected in the start-up wizard.
Equipped with the industry’s first intelligent combustion
management system and powerful control technology,
the new generation Vitodens 200-W gas-fired wall-mount
condensing boiler delivers unparalleled performance,
reliability and comfort.
■ Expanded Application Range with increased capacity up
to 530 MBH (155 kW). Multi-boiler installation up to
4240 MBH (1240 kW) with up to 8 boilers (models B2HA
88, 100, 112, 150, 311, 352, 399 and 530).
■ Greater Venting Flexibility with increased vent length
[up to 180 ft. (55 m)] and multiple venting options.
- Horizontal or vertical sealed combustion coaxial
venting (field supplied).
- Horizontal, vertical or hybrid sealed combustion
double-pipe venting (field supplied).
- Horizontal or vertical single-wall venting (field
supplied).
■ Compact, Esthetic Product Design and zero clearance
to combustibles.
■ Extremely Quiet Operation; quieter than most
refrigerators.
■ True High-Altitude Operation up to 10,000 ft. (3,000 m)
with simple electronic adjustment.
■ Efficiency up to 98% through intensive condensation.
■ The gas train on the burner meets the requirement
of ASME/CSD-1.

Vitodens 200-W B2HA 88-150, 311- 530 Technical Data
3
5683 718 - 19
Product Information
Cross-Section
Products may not be exactly as shown
AInox-Radial heat exchanger made from stainless steel
– for high operational reliability and a long service life.
Large heating output in the smallest of spaces
B Modulating MatriX cylinder burner for extremely
clean combustion and quiet operation
CVariable speed combustion fan for quiet and
economical operation
DGas and water connections
EDigital boiler control unit
Delivered condition
Wall mounted gas condensing boiler with Inox-Radial heat
exchanger, modulating MatriX cylinder burner for natural
gas and LPG, plus wall mounting bracket. Vitotronic 200
for weather-compensated operation. Preset for operation
with natural gas. Fully plumbed and wired. White epoxy-
coated casing.
Vitodens 200-W B2HA 88-150, 311-530
The flue gas temperature is only approximately 9ºF-27ºF
(5ºC-15ºC) above boiler return temperature (see chart
below).

Vitodens 200-W B2HA 88-150, 311- 530 Technical Data
5683 718 - 19
4
Technical Data
Technical Data
*A For high altitude installations 5,000 - 10,000 ft. (1500 m - 3000 m), the input for model B2HA 88,100, 150,
311, 352, 530 will have an altitude de-ration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m)
average of 2.8% / 1,000 ft. (305 m).
*BThe input for model B2HA 112, 399 at 10,000 ft. (3000 m) will have an input de-rate of 13%.
*C Net AHRI rating based on piping and pick-up allowance of 1.15.
*D Tested to AHRI, BTS-2000 Testing Standard Method to Determine Efficiency of Commercial Heating Boilers.
*1 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator
must be installed upstream of the heating system.
*2 See “Waterside Flow” starting on page 9 of this manual.
*3 Output based on 180ºF (82ºC), 80ºF (26ºC) system supply/return temperature.
Boiler Model No. B2HA 88, 311 *A100, 352 *A112, 399 *B150, 530 *A
CSA input Natural Gas (NG)
CSA input Liquid Propane Gas (LPG)
CSA output NG *3
CSA output LPG *3
MBH
(kW)
MBH
(kW)
MBH
(kW)
MBH
(kW)
71-311
(21-91)
104-311
(30-91)
67-294
(20-86)
98-294
(29-86)
71-352
(21-103)
104-352
(30-103)
67-333
(20-98)
98-333
(29-98)
113-399
(33-117)
113-399
(33-117)
103-375
(30-110)
103-375
(30-110)
113-530
(33-155)
113-530
(33-155)
103-495
(30-145)
103-495
(30-145)
DOE/AHRI Gross output
Net AHRI Rating *C
MBH
(kW)
MBH
(kW)
292
(85)
254
(74)
329
(96)
286
(84)
371
(109)
323
(95)
490
(144)
426
(125)
Heat exchanger surface area ft.2
(m2)
28.88
(2.68)
28.88
(2.68)
36.78
(3.41)
36.78
(3.41)
Min. gas supply pressure
Natural gas
Liquid propane gas
“w.c.
“w.c.
4
10
4
10
4
10
4
10
Max. gas supply pressure *1
Natural gas
Liquid propane gas
“w.c.
“w.c.
14
14
14
14
14
14
14
14
ANSI Z21,13/CSA 4.9
Thermal efficiency % 94.5 94.5 93.9 93.5
AHRI, BTS-2000 *D
Combustion efficiency
Thermal efficiency
%
%
94.2
94.0
94.0
93.5
93.5
93.0
93.0
92.5
Weight lbs
(kg)
194
(88)
194
(88)
298
(135)
298
(135)
Boiler water content USG
(L)
3.4
(12.8)
3.4
(12.8)
4
(15)
4
(15)
Boiler max. flow rate *2 GPM
(L/h)
25
(5700)
25
(5700)
38
(8600)
38
(8600)
Max. operating pressure
at 210ºF (99ºC)
psig
(bar)
60
(4)
60
(4)
80
(5.5)
80
(5.5)
Boiler water temperature
- Adjustable high limit (AHL) range
space heating (steady state)
DHW production
- Fixed high limit (FHL)
ºF
(ºC)
ºF
(ºC)
ºF
(ºC)
68 to 185
(20 to 85)
185
(85)
210
(99)
68 to 185
(20 to 85)
185
(85)
210
(99)
68 to 185
(20 to 85)
185
(85)
210
(99)
68 to 185
(20 to 85)
185
(85)
210
(99)
Boiler connections
Boiler heating supply and return
Pressure relief valve
Drain valve
Boiler supply/return for
indirect-fired DHW storage tank
(field supplied)
Gas valve connection
NPTM
NPTF
(male
thread)
NPT
NPTF
1bin.
¾in.
¾in.
1bin.
1 in.
1bin.
¾in.
¾in.
1bin.
1 in.
2 in.
¾in.
¾in.
2 in.
1 in.
2 in.
¾in.
¾in.
2 in.
1 in.

Vitodens 200-W B2HA 88-150, 311- 530 Technical Data
5
5683 718 - 19
Technical Data
Technical Data (continued)
*A For high altitude installations 5,000 - 10,000 ft. (1500 m - 3000 m), the input for model B2HA 88, 100, 150,
311, 352, 530 will have an altitude de-ration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m)
average of 2.8% / 1,000 ft. (305 m).
*BThe input for model B2HA 112, 399 at 10,000 ft. (3000 m) will have an input de-rate of 13%.
*4 Measured flue gas temperature with a combustion air temperature of 68°F (20°C).
*5 Based on maximum input rate.
*6 Requires 1 inch (25 mm) tubing. See the Installation Instructions of the Vitodens 200-W, B2HA for details.
*7 For side wall vent installations (coaxial system):
Do not exceed max. equivalent length specified in the Installation Instructions of the Vitodens 200-W, B2HA
Venting System.
Side wall co-axial vent installation must include Viessmann protective screen!
For details refer to the Installation Instructions for the Vitodens 200-W, B2HA Venting System.
The Vitodens 200-W can only be common vented with other Vitodens 200-W boilers of the same size and series.
For details refer to the Common Venting Manual.
*8 Add approximately 2b inches (65 mm) for coaxial vent pipe transition adaptor.
*9 Optional low NOx certified by SCAQMD Natural Gas models available.
For information regarding other Viessmann System Technology componentry, please reference the documentation
of each respective product.
Boiler Model No. B2HA 88, 311 *A100, 352 *A112, 399 *B150, 530 *A
Dimensions
Overall depth
Overall width
Overall height *8
inches
(mm)
inches
mm)
inches
mm)
21
(530)
19
(480)
43b
(1105)
21
(530)
19
(480)
43b
(1105)
27.1
(689)
235/8
(600)
44b
(1128)
27.1
(689)
235/8
(600)
44b
(1128)
Flue gas *4
Temperature (at boiler return
temperature of 86ºF (30ºC)
- at rated full load
- at rated partial load
Temperature (at boiler return
temperature of 140ºF (60ºC)
ºF (ºC)
ºF (ºC)
ºF (ºC)
135 (57)
99 (37)
162 (72)
135 (57)
99 (37)
162 (72)
124 (51)
102 (39)
158 (70)
140 (60)
102 (39)
165 (74)
Flue gas parameters
Mass flow rate
Natural gas
- at rated heating output
(DHW heating)
- at partial load
Liquid propane gas
- at rated heating output
(DHW heating)
- at partial load
lb/h (kg/h)
lb/h (kg/h)
lb/h (kg/h)
lb/h (kg/h)
384 (174)
115 (52)
364 (165)
108 (49)
384 (174)
115 (52)
364 (165)
108 (49)
463 (210)
116 (53)
509 (231)
130 (59)
558 (253)
116 (53)
613 (278)
130 (59)
Max. condensate flow rate *5
for NG and LPG
TS/TR=104/86ºF (40/30ºC)
USG/h
(L/h)
3.1
(11.7)
3.5
(13.1)
4.35
(16.5)
5.28
(20.0)
Condensate connection *6 hose nozzle
Ø in. ¾-1¾-1¾-1¾-1
Boiler flue gas connection *7 Ø
in. (mm) 43/8(110) 43/8(110) 43/8(110) 43/8(110)
Combustion air supply connection
(coaxial)
outer
Ø in. (mm) 6 (150) 6 (150) 6 (150) 6 (150)
Sound Rating
- at maximum input
- at minimum input
dB
dB 69
38
69
38
57
40
61
40
NOx @ 3% O2<20 PPM *9
This manual suits for next models
3
Table of contents