Whirlpool 015-0005 User manual

754764-100 Rev. A
1
THANK YOU...
for selecting an Eljer bathing product. Your new bath is shipped to you after careful inspection. The whirlpool
version is completely assembled with pump and circulatory system piping. All you need to finish the installation
are your selected fittings, electrical connections and support bedding material.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
© Eljer 2011
All product names listed herein are trademarks of Eljer unless otherwise noted.
For questions or service issues, please call Technical Support 1-(800)-442-1902.
Please do not contact or return product to the store.
MODEL NUMBERS
015-0005, 015-0015, 015-0026,
015-0066, 015-0076, 015-0077,
015-0305, 015-0309
PREMIERE WHIRLPOOL
INSTALLATION AND
OPERATION MANUAL

2
754764-100 Rev. A
TABLE OF CONTENTS:
Cover
................................................................................................Page 1
Table of Contents
..............................................................................Page 2
Safety Instructions Notice.................................................................Page 3
Installation, Framing and Post Installation
Clean-Up Instructions.......................................................................Page 4
Typical Flange & Under Deck Mounting Instructions........................Page 6
General Specifications for Whirlpools................................................Page 7
Roughing-in References for All Model Series...................................Pages 8 - 10
Electrical Installation Instructions
.....................................................Page 11
Total Massage Whirlpools.............
....................................................Page 12
Operating Instructions.......................................................................Page 13
Cleaning and Maintenance...............................................................Page 14
Warranty
......................................
.....................................................Page 15

754764-100 Rev. A
3
!
!
!
!
!
!
!
SAVE THESE INSTRUCTIONS
WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision.
WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.
WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within
60 inches (1524mm) of this unit.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse
medical history should consult a physician before using this product.
WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than 2/3
can cause overflow and slippery conditions. Exercise caution when entering and exiting.
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or
hyperthermia resulting in loss of consciousness or even drowning.
WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.
Never drop or insert any object into any opening.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by
American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI,
push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button
being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this hydromassage
bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using.
A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no. 8 AWG solid
copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as
needed to comply with local requirements. To reduce the risk of an electric shock, connect this connector to the
grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors
supplying this unit.
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!

4
754764-100 Rev. A
Each bath arrives ready for installation, completely equipped with the pump and plumbing
necessary for operation. However, a drain/overflow kit is required for each bath and it is
not included.
The variety of installations for this bath may require framing procedures other than those shown.
Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square.
Installation and Framing Instructions
Remove the bath from the carton. Retain the shipping carton until satisfactory
inspection of the product has been made. Do not lift the bath by the plumbing at
any time; handle by the shell only.
All bath units are factory tested for proper operation and watertight connections
prior to shipping. Prior to installation and before enclosing with wallboard, tile,
etc., the bath must be filled with water and operated to check for leaks that may
have resulted from shipping damage or mishandling.
The sumps of these baths are supported by the feet and no additional sump
support is required. Once the bath is in place, the feet should be shimmed and
secured accordingly so the rim of the bath contacts the stringer or pier but
supports no weight.
Provisions must be made in all installations for an access opening for servicing the
bath pump. Unless an access opening of at least 12" x 24" (305mm x 610mm) is
provided, warranty service will not be performed. It is strongly recommended that an
additional opening be provided for access to drain components.
Each bath has a nominal length (L), width (W), and Height (H) along with a rim
height. Unless otherwise noted in the following rough-in references, assume
that the nominal tolerances are as much as +/-1/4 inch (6mm). Therefore, it is
strongly recommended that the installer build the surrounding structure after
receiving the actual bath. Structural measurements should be verified against
the actual bath received to ensure proper fit.
!
!
!
!
!
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden
popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid
dishwashing detergent.
Stubborn dirt or stains may be removed using granular Spic and Span®mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.

754764-100 Rev. A
5
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as
needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access
opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the
drain components. The apron should not be used as the primary access opening.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
F
CUTOUT
AS DESIRED
G
CUTOUT
C
24
(610 mm)
12
(305 mm)
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
TYPICAL RECESS INSTALLATION
24
(610 mm)
12
(305 mm)
C
E
D
W
LEVELING
STRINGERS
TILE
TILE
BEAD
STRIP
LEVELING STRINGER
1 x 4 (not for support)
BATH
ADHESIVE
SEALANT
WALLBOARD
NOTE: Tile bead kit not included and
must be purchased separately.
C*
TYPICAL INSTALLATION
FIGURE 1
The bath must be supported along its entire bottom. Use mortar as
bedding material (do not use sand or foam). Apply enough mortar to support
the complete bottom of the bath. After the mortar has been poured, and before
it sets, position whirlpool or bath within recess until the rim is leveled against
the leveling stringers (see "Typical Recess Installation") shown below.
The rim of the bath must not support weight. Allow the mortar material to
completely harden before applying weight to the rim or bottom of the bath. Any
finish material such as tile or wall board must be self-supporting if it contacts
the deck of the bath.
3. Install drain components to the whirlpool following the drain installation instructions.
Before replacing your whirlpool for final installation, be certain that an opening has
been provided in the sub-floor for the drain. See the roughing-in drawing and
Table 1 for suggested opening size (shadowed) and location dimensions. The
drain/overflow of the bath extends below the bottom of the bath. Note that this
requires a cutout in the floor.
The floor structure beneath the bath must be able to support a total weight of bath,
water, and bather. Refer to Table 1 under total weight for your model.
2. Remove the whirlpool and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line.
The rim of the bath must not support weight.
1. Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral leveling feet IF
necessary. Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
!
!
!
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR
END FOR SERVICE.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP/MOTOR END FOR SERVICE.
FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 7. FOR C, G & F DIMENSIONS SEE TABLE 1 ON PAGE 7.
NOTE:
FRONT EDGE
OF BATH MUST
BE SUPPORTED
BY STUD WALL OR
ELJER APRON KIT
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED,WARRANTY SERVICE WILL NOT BE PERFORMED.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED,WARRANTY SERVICE WILL NOT BE PERFORMED.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS. ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
SEE TABLE 1 ON PAGE 7.

6
754764-100 Rev. A
SUGGESTED WHIRLPOOL / BATH
INSTALLATION METHOD
SECURE THE BATH TO THE STUDS AS SHOWN FOR
WOOD OR STEEL STUD CONSTRUCTION.
TYPICAL FLANGE MOUNTING DETAIL
STUD
WATERPROOF DRYWALL
OR CEMENT BOARD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
SEALANT
TUB
ROOFING NAIL
1 x 3 (25 x 76mm) WOOD
STRINGER FULL LENGTH
1 x 3 (25 x 76mm) WOOD
STRINGER FULL LENGTH
STEEL
STUD
WASHER
TILE
SEALANT
TUB
4" (102mm)
DRYWALL
SCREW
WOOD
STUDS
STEEL
STUDS
TYPICAL INSTALLATION -
CORNER
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610mm) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
58-1/2"
(1486mm)
58-1/2"
(1486mm)
25"
(635mm)
25"
(635mm)
PUMP ACCESS PANEL
LEVELING
STRINGER
19-1/2"
(495mm)
12"
(305mm)

754764-100 Rev. A
7
SPECIFICATIONS:
GENERAL SPECIFICATIONS FOR ELJER WHIRLPOOLS AND BATH TUBS
SIDE VIEW DRAIN / OVERFLOW
END VIEW
L
H
W
CA
B
J
A 15-1/4"
(387mm)
B 10-1/4"
(260mm)
A 16-1/4"
(413mm)
B 10-1/4"
(260mm)
A 16-1/4"
(413mm)
B 8-1/4"
(209mm)
A 17"
(432mm)
B 10-1/2"
(267mm)
A 16"
(406mm)
B 10-1/2"
(267mm)
A 16"
(406mm)
B 10-1/2"
(267mm)
A 14"
(356mm)
B 9-1/2"
(241mm)
C 17"
(432mm)
C 17-1/2"
(445mm)
C 17-7/8"
(454mm)
C 19-1/2"
(495mm)
C 18"
(457mm)
C 18"
(457mm)
C 18-1/2"
(469mm)
58-1/2"
(1486mm)
x 30-1/2"
(775mm)
58-1/2"
(1486mm)
x 30-1/2"
(775mm)
58-1/2"
(1486mm)
x 34-1/2"
(876mm)
58-1/2"
(1486mm)
x 58-1/2"
(1486mm)
70-1/2"
(1791mm)
x 34-1/2"
(876mm)
70-1/2"
(1791mm)
x 34-1/2"
(876mm)
Not
Applicable
60"
(1524mm)
x 30-1/2"
(775mm)
60"
(1524mm)
x 30-1/2"
(775mm)
60"
(1524mm)
x 34-1/2"
(876mm)
Not
Applicable
72"
(1829mm)
x 34-1/2"
(876mm)
72"
(1829mm)
x 34-1/2"
(876mm)
60"
(1524mm)
x 30-1/2"
(775mm)
L 60" (1524mm)
W 32" (813mm)
H 18-1/2" (469mm)
L 60" (1524mm)
W 32" (813mm)
H 19" (483mm)
L 60" (1524mm)
W 36" (914mm)
H 19-3/8" (492mm)
L 60" (1524mm)
W 60" (1524mm)
H 21" (533mm)
L 72" (1829mm)
W 36" (914mm)
H 19-1/2" (495mm)
L 72" (1829mm)
W 36" (914mm)
H 19-1/2" (495mm)
L 60" (1524mm)
W 32" (813mm)
H 18-3/4" (476mm)
98 lb.
(45 kg.)
98 lb.
(45 kg.)
102 lb.
(46 kg.)
119 lb.
(54 kg.)
103 lb.
(47 kg.)
119 lb.
(54 kg.)
135 lb.
(61 kg.)
418 lb. (190 kg)/
31 lb./sq.ft.
(153 kg/sq.m)
418 lb. (190 kg)/
31 lb./sq.ft.
(153 kg/sq.m)
414 lb. (188 kg)/
28 lb./sq.ft.
(135 kg/sq.m)
695 lb. (316 kg)/
34 lb./sq.ft.
(166 kg/sq.m)
543 lb. (247 kg)/
30 lb./sq.ft.
(148 kg/sq.m)
559 lb. (254 kg)/
31 lb./sq.ft.
(152 kg/sq.m)
455 lb. (207 kg)/
34 lb./sq.ft.
(167 kg/sq.m)
40
40
45
72
55
55
40
Description Drain /
Overflow
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Weight with
Water / Floor
Loading
Product
Weight
Gallon to
Overflow
Height to
Underside
of Deck: C
Dimensions
L-W-H
2-1/4"
(57mm)
2"
(51mm)
2"
(51mm)
3-1/4"
(83mm)
1-1/2"
(38mm)
1-1/2"
(38mm)
2-1/4"
(57mm)
Tub Edge to
Centerline
Overflow: J
015-0005
5' x 32"
Cypress
015-0015
5' x 32"
Madison
015-0026
5' x 36"
Canterbury
015-0066
Triangle
015-0076
6' x 36"
Emblem
6' x 36"
Emblem
Total Massage
015-0305/0309
5' x 32"
Patriot
TABLE 1

8
754764-100 Rev. A
ROUGH-IN REFERENCES
CYPRESS MODEL 015-0005
MADISON MODEL 015-0015
9" x 14" (229 x 356mm)
FLOOR CUTOUT
9" x 14" (229 x 356mm)
FLOOR CUTOUT
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
0/I
19-1/2"
(495mm)
10-1/4"
(260mm)
60"
(1524mm)
40-1/2"
(1029mm)
32"
(813mm)
16"
(406mm)
0/I
19-1/2"
(495mm)
10-1/4"
(260mm)
40-1/2"
(1029mm)
32"
(813mm)
60"
(1524mm)
16"
(406mm)

754764-100 Rev. A
9
ROUGH-IN REFERENCES
CANTERBURY MODEL 015-0026
TRIANGLE MODEL 015-0066
9" x 14" (229 x 356mm)
FLOOR CUTOUT
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
0/I 10-1/2"
(267mm)
35-1/2"
(902mm)
46"
(1168mm)
48-5/8"
(1235mm)
60"
(1524mm)
35-1/2"
(902mm)
25-1/4"
(641mm)
9" x 14" (229 x 356mm)
FLOOR CUTOUT
PROVIDE ACCESS
TO PUMP
18"
(457mm)
24-1/2"
(622mm)
8-1/4"
(209mm)
60"
(1524mm)
44-1/2"
(1130mm)
36"
(914mm)

10
754764-100 Rev. A
ROUGH-IN REFERENCES
EMBLEM MODEL 015-0076
EMBLEM TOTAL MASSAGE MODEL 015-0077
PATRIOT MODEL 015-0309/0305
(Right hand version shown)
9" x 14" (229 x 356mm)
FLOOR CUTOUT
9" x 14" (229 x 356mm)
FLOOR CUTOUT
21-1/2"
(546mm)
10-1/2"
(267mm)
51-1/2"
(1308mm)
36"
(914mm)
72"
(1829mm)
18"
(457mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS 0/I
18"
(457mm)
9-1/2"
(241mm)
42"
(1067mm)
32"
(813mm)
60"
(1524mm)
16"
(406mm)
0/I

754764-100 Rev. A
11
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
BLACK
WHITE
120 VAC
GND.
GFCI
OUTLET
WHIRLPOOL MOUNTED
AIR SWITCH OR
WALL TIMER
ELECTRICAL INSTALLATION
PUMP/MOTOR
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other
applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Install to permit access for servicing.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
AIR SWITCH WHIRLPOOLS
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the
electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded
neutral wire and a third wire, earth ground, are essential. A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT IS
REQUIRED IF THE OPTIONAL HEATER IS INSTALLED (SEE INSTALLATION INSTRUCTIONS SUPPLIED WITH
THE HEATER MODEL NUMBER – 494-1000).

12
754764-100 Rev. A
TOTAL MASSAGE CIRCUIT WITH OPTIONAL HEATER
CONTROL PAD
PUMP
HEATER
120 V, 60 Hz
15 AMP GFCI
120 V, 60 Hz
20 AMP GFCI
BLOWER
PUMP
FLOW
CONTROL
VALVE
PUMP
TIMER
CONTROL
VARIABLE
CONTROL
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
TOTAL MASSAGE WHIRLPOOLS
The whirlpool pump and blower should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be
hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply
panel. A grounded neutral wire and a third wire, earth ground, are essential. A SEPARATE 15 AMP MAXIMUM GFCI
CIRCUIT IS REQUIRED IF THE OPTIONAL HEATER IS INSTALLED (SEE INSTALLATION INSTRUCTIONS
SUPPLIED WITH THE HEATER MODEL NUMBER – 494-1000).
ELECTRICAL
FEED
GFCIGFCI

754764-100 Rev. A
13
OPERATING INSTRUCTIONS
1. Fill the bath to at least 3 inches above the jets before activating the pump.
2. The pump is activated by an on/off switch. Each depression of the button switches the power either on or off.
Do not repeatedly depress the switch in rapid order if you do not see the whirlpool function right away,
as it may take a few seconds before you can see it fully operating.
3. If any factory installed ttings are removed do not operate the unit. A safety hazard may occur.
4. Do not use bubble bath when you operate the whirlpool pump.
This might cause excessive foaming.
5. Both air and whirlpool systems are plumbed in a way that water will
drain from the plumbing easily.
ON-OFF SWITCH
The whirlpool bath pump is activated by a on-off switch. Each depression of the switch
will actuate the pump. If off, one depression will turn the pump on. If on,
the next depression will turn it off.
JET OPERATION AND ADJUSTMENT
The jets can be easily adjusted by pointing the jet-nozzle in the desired direction. For units
with Hydro Jets, the strength of the waterow and air induction can be regulated through
twisting the jet-nozzle. Twisting the nozzle clockwise will decrease the water ow and nally completely
turn off the water ow of that particular jet. If the nozzle is twisted counter- clockwise then the water
ow will increase up to its maximum ow.
TOTAL MASSAGE
Total Massage units are a combination of a whirlpool and air bath. The Total Massage control pad contains six (6) buttons.
The top three controls on the “Therapy Control Center” operate the whirlpool and the bottom three controls operate the air
system. The whirlpool and air massages systems may be used at the same time if desired.
The air bath is controlled by a three button control:
1. The rst button switches the blower on or off. The other features will not operate unless the blower is turned on.
2. The second button sets the power level of the blower. Holding the button depressed will cycle the blower power from
low to high in a continuous cycle. When the desired level is reached, remove your nger quickly from the button to
maintain that power setting.
3. The third button is a three step wave action button. Once activated, the air holes expell air in a slow pulsating ow
called wave action. There are 3 steps or positions for wave strength.
a. Position #1 operates the blower at a steady ow.
b. Position #2 operates the blower at a quick wave action.
c. Position #3 operates the blower at a slower wave action.
TOTAL MASSAGE UNITS ARE EQUIPPED WITH AN AUTOMATIC CLEANING AND PURGE CYCLE
A
ir Baths have a preprogrammed cleaning and purge cycle built in to expel the remaining water in the air channels. It
activates within 20 minutes after the bath is drained, blows for about 2 to 3 minutes and then shuts off automatically.
There is nothing to be alarmed about if you hear a blowing noise coming from the tub after the tub has been turned off.
The noise you hear is the cleaning cycle in operation.
AIR SWITCH
Switches the
jet-pump
on or off
Adjusts the variable
water ow of the jets
Switches from
continuous to wave
action water ow
Switches from
continuous to wave
action air ow
Adjusts the variable
air ow of the blower
Switches the
air blower
on or off

14
754764-100 Rev. A
Fill whirlpool with warm water and add two teaspoons of powdered automatic dishwasher (not laundry)
detergent and one-half cup of household bleach to filled whirlpool.
Activate whirlpool system in accordance with operating instructions and run system for two minutes.
Drain and refill whirlpool with cold water. Circulate for five minutes.
Drain whirlpool completely after step 3 (above) is completed.
Your Eljer whirlpool is designed to give you many years of pleasure with reasonable care and maintenance.
Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other
Eljer fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its lasting luster with
proper care and maintenance.
CLEANING AND MAINTENANCE:
• Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surface damage.
• Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
• Clean after use with a mild liquid household detergent cleaner. Do not turn on jets when such cleaners are present.
Do not use: Lestoil® Cleaner; Lysol® Disinfectant (spray or concentrate); or Lysol® Basin, Tub and Tile Cleaner;
Windex® Cleaner; Mr. Clean® Cleaner; Dow® Disinfectant Bathroom Cleaner*; or other cleaning products in
aerosol cans.
HARSH CHEMICALS, SHARP AND ABRASIVE OBJECTS
SHOULD NEVER BE USED ON ACRYLIC SURFACES
• Do not use wire brushes, knives or sharp objects to remove stains or other surface blemishes.
• Use of abrasive cleaners or powders will dull the surface. If the glossy surface loses its sheen, dulled areas can
be partially restored by rubbing with a white automotive body polishing compound and waxing with a liquid wax.
Do not wax surfaces where you walk or stand.
• Do not allow nail polish remover, acetone, dry-cleaning fluid, paint remover, or other solvents to come into contact
with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
Do not permit drain cleaner to enter circulation system.
• Burning cigarettes will irreparably damage the surface of the whirlpool.
CLEANING/PURGING THE CIRCULATION SYSTEM
Once every month the circulating system must be purged and cleaned. Follow the steps outlined below:
1.
2.
3.
4.
For Troubleshooting and Repair Parts please log on to www.eljer.com
* Lestoil® is a registered trademark of The Clorox Company.
Lysol® is a registered trademark of The Linden Company.
Windex® is a registered trademark of S.C. Johnson and Son, Inc.
Mr. Clean® is a registered trademark of The Proctor and Gamble Company.
Dow® is a registered trademark of The Dow Chemical Company.

754764-100 Rev. A
15
AS AMERICA, INC. LIMITED LIFETIME WARRANTY FOR
ELJER PREMIERE SERIES ACRYLIC TUBS
AS America, Inc. (“American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this
tub or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and
maintenance so long as it is owned by the original consumer purchaser.
This limited warranty does not apply to commercial installations. The warranty for commercial installations is three (3) years.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER
CONTRARY TO THE INSTALLATION INSTRUCTIONS. In no event will American Standard be liable for the cost of repair or
replacement of any installation materials including but not limited to tiles, marble etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of proper maintenance and
cleaning as directed in the owner’s manual and use of other than genuine American Standard replacement parts, in all cases
whether caused by a plumbing contractor, service company, the owner or any other person.
2. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
4. Options and accessories. American Standard’s limited warranty on these items is lifetime for parts only, two (2) years for the
heater and five (5) years on labor. This lifetime limited warranty covers accessories manufactured by American Standard
(e.g. aprons, drains, grab bars, trim kits) against defects of material or workmanship. Warranty coverage begins on the date
the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs
incurred in connection with product removal or installation under this limited warranty.
6. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY EXPRESSLY
DISCLAIMED, OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED
WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE. (Some
jurisdictions do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or
consequential damages, so these limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly distributors, retailers,
dealers, installation contractors and users of plumbing products should determine whether there are any code restrictions on
the installation or use of a specific product.)
This limited warranty gives you specific legal rights.You may have other statutory rights that vary from state to state or province to
province, in which case this limited warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the
product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the
following address:
In the United States:
AS America, Inc.
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty information
may also be obtained by calling the following
toll free number: (800) 442-1902
www.eljer.com
In Canada:
AS Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.eljer.com
In Mexico:
American Standard B&K Mexico
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 01-800-839-1200
www.eljer.com
This manual suits for next models
7
Table of contents