Whitehall Best-Care Corterra WH3776 User manual

Ligature Resistant
Corterra™ Corner Basin
ADA Compliant
6900-206-001 April 2019
Model WH3776
INSTALLATION, OPERATIONS AND
MAINTENANCE MANUAL
WH3776L-WH3374L
®
Ÿ Patented D840,523

WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
a
Instructions for Operation and Care of Best-Care WH3776
Important: Some options may slightly alter installation. To ensure proper installation
review the Manual thoroughly and verify rough-ins before beginning any work. File this
Manual with the owner or maintenance personnel upon completion of installation.
ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the
local code authority and is the responsibility of the installer for verification.
Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall
anchors and wall anchoring hardware with a minimum Pull-Out Force of 1000 pounds
(lbs) per anchor for appropriate wall construction.
Single Temp Valve Assembly: Recommended working water pressure is 30 PSI (2.07
bars) minimum to 100 PSI (6.89 bars) maximum. Maximum temperature is 130°F
(54.4°C). Maximum outlet temperature recommended is 105°F (40.6°C). Valve
assembly must be drained prior to being subjected to freezing temperatures. A
checkstop is provided with this valve assembly.
T/P Mixing Valve Assembly: Recommended working water pressure is 30 PSI (2.07
bars) minimum to 100 PSI (6.89 bars) maximum. Maximum hot water temperature is
180°F (82°C). Temperature adjustment range is 85°F-115°F (29°C-46°C). Minimum hot
water supply temperature must be 5°F (3°C) above desired set temperature. Valve
assembly must be drained prior to being subjected to freezing temperatures. The valve
assembly has checks integral to the inlets however, angle stops are to be provided by
the installer.
Teflon tape is recommended on threaded connections where applicable to reduce the
possibility of leaks.
Prior to installation, supply lines must be flushed of all foreign material such as pipe
dope, chips, or solder. Debris or foreign material in water supply may damage valve.
Provide 110-120 VAC/60Hz/3A (MAX) electrical receptacle for factory supplied
120VAC/9VDC, 100mA plug-in transformer.
Upon receiving, verify count and inspect packaging for obvious signs of damage or
missing containers. If there are any issues upon receiving make note on bill of lading and
report to carrier and manufacturer promptly. Remove fixture assemblies from packaging
and ensure all parts are present before beginning installation. Do not discard packaging
until all parts have been accounted for. Refer to Acorn terms, conditions of sales and
warranty for more information.
NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth
grounded per N.E.C. (National Electrical Code).

1
Table of Contents
Dimensional Data...........................................................................................................................................3
Installation.................................................................................................................................................7-13
Prior to Installation ........................................................................................................................................ a
Accessibility Overview ...................................................................................................................................2
Rough-Ins ...................................................................................................................................................4-6
Cleaning and Maintenance ..........................................................................................................................15
Components & Repair Parts ...................................................................................................................16-19
Warranty Information....................................................................................................................................20
Troubleshooting ...........................................................................................................................................14
PAGE
Required Items for Installation - Not Supplied
?7/16" Hex Wrench
?Chalk Line
?Hammer
?1/4” Slotted Tip Screwdriver For Metering
Adjustment
?Carpenters Level
?1/2" NPS Outlet Angle Stops
?1/2" NPS Flexible Supply Hose
(For -MXTP Valves Only)
?Teflon Tape
?Driver For 1/4” Shank Bit - For Center Reject Bit
?Fixture Wall Anchors and Anchoring Hardware
(and Appropriate Tools) - For 3/8" (9 Places)
& 1/4” Punching (3 Places)
?Plumbers Putty
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

2
ACCESSIBILITY OVERVIEW
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
22"
[559]
15"
[381]
27"
[686]
Min
4"
[102]
34"
[864]
Rim Max
22"
[559]
12"
[305]
213
4"
[552] 213
4"
[552]
22"
[559]
14"
[356]
213
4"
[552]
31"
[787]
Rim Max
29"
[737]
Min
33"
[838]
Rim Max
27"
[686]
Min
4"
[102]
4"
[102]
22"
[559]
14"
[356]
213
4"
[552]
29"
[737]
Min
34"
[838]
Rim Max
4"
[102]
27"
[686]
Min
27"
[686]
Min
ADA
Adult
ADA ages
6 thru 12
CBC
(California Building Code)
OBC
(Ontario Building Code)

3
DIMENSIONAL DATA
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
(Left Corner Shown)
29"
[737]
213
4"
[552]
22"
[559]
25"
[635]
4"
[102]
15"
[381]

4
!!
ROUGH-IN DIMENSIONS
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
(Left Corner)
20" ADA (6-13)
23" ADA Adult
22" OBC
17" ADA (6-13)
20" ADA Adult
19" OBC
121
2" ADA (6-13)
151
2" ADA Adult
141
2" OBC
8" 5"
16"
31" ADA (6-13)
34" ADA Adult
33" OBC
281
2" ADA (6-13)
311
2" ADA Adult
301
2" OBC
(8) 7/16" Diameter Mountings Holes, Recommended 5/16"
1-1/2" O.D. Tube Lavy Waste Outlet For Compression Joint
1/2" NPS Hot & Cold Angle Stops (By Others)
(3) Ø1/4" Mounting holes
or 3/8" Hex or Concrete Anchors & Washers with min.
21
2"
51
4"
81
2"
141
4"
201
2"
231
4"
261
2"
11
2"51
4"
TYP
21
2"
5"
8"
101
2"
131
2"
16"
(6) Ø3/4" x 2-1/4" Slots for optional 5/8" x 6" Long UNC
Carrier Support Studs. Reference JRSMITH 0816-M31
Pull-Out Force of 1000 lbs per Anchor.

5
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
ROUGH-IN DIMENSIONS
(Right Corner)
20" ADA (6-13)
23" ADA Adult
22" OBC
17" ADA (6-13)
20" ADA Adult
19" OBC
121
2" ADA (6-13)
151
2" ADA Adult
141
2" OBC
8"
5"
16"
31" ADA (6-13)
34" ADA Adult
33" OBC
281
2" ADA (6-13)
311
2" ADA Adult
301
2" OBC
(8) 7/16" Diameter Mountings Holes, Recommended 5/16"
1-1/2" O.D. Tube Lavy Waste Outlet For Compression Joint
1/2" NPS Hot & Cold Angle Stops (By Others)
(3) Ø1/4" Mounting holes
or 3/8" Hex or Concrete Anchors & Washers with min.
21
2"
51
4"
81
2"
141
4"
201
2"
231
4"
261
2"
11
2"
51
4"
TYP
21
2"
5"
8"
101
2"
131
2"
16"
(6) Ø3/4" x 2-1/4" Slots for optional 5/8" x 6" Long UNC
Carrier Support Studs. Reference JRSMITH 0816-M31
Pull-Out Force of 1000 lbs per Anchor.

ROUGH-IN DIMENSIONS
(MC-FLR FIXTURE SUPPORT FLOOR MOUNTED TYPE)
6
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
18"
28 1
2" ADA (6-13)
31 1
2" ADA Adult
30 1
2" OBC
21
2" 43
8"
5"
101
2"
16"
51
4"
141
4"
231
4"
4"
4" 23
4"
23
4"Ø9
16"
BASE DETAIL
SCALE: 3:1
Finished
Floor
Finished Wall
Finished Wall
(6) 5
8" x 6" Long
Support Studs
Stud not to extend past
Finished Wall more than 1"
12"
31
4"
251
4"
26"
28 1
2" ADA (6-13)
31 1
2" ADA Adult
30 1
2" OBC
21
2" 43
8"
Finished
Floor
WALL PLATE
CORNER
SIDE PLATE
Finished Wall Finished Wall

FIXTURE ANCHORING
Disassemble Bottom Cover from Deck Assembly by
1removing #10-32 x 1/2” (Qty. 7) and 1/4-20 x 1/2”
(Qty. 4) Hex Button Head Center Reject Screw.
Locate and anchor the basin to the finished wall
using mounting hardware by others, refer to
dimensional data for rough-in information. 3/8” wall
anchors with min. Pull-Out Force of 1000 lbs per
anchor required for fixture mounting. Assemble waste
assembly and make appropriate connections. Test for
leaks for usage. HINT: It may be advantageous to
install Faucet prior to wall mounting.
POINTS
MOUNTING
BOTTOM
COVER
1
Instructions for Operation and Care of Best-Care WH3776
7
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

1
2
3
4
5
STRAINER
FLANGE
6
3
Assemble waste piping using teflon tape on all threaded
3connections and make up waste connections to 1-1/2" P-trap.
Install Strainer to Basin using plumbers putty
2on underside of grid strainer flange. From
beneath Basin, assemble Gasket, Washer and
Jam Nut as shown to Strainer and tighten
securely. Add Close Elbow to Strainer
Assembly as indicated.
HINT: Teflon tape is recommended on all Threaded Waste and
Supply Connections.
NOTE: Waste Assembly may require field cutting and fitting by the
installer.
Á Rubber Gasket
Å Waste Outlet Connection
À Strainer w/ 1-1/2"-16 UNE Threads
 Flat Fiber Washer
à 1-1/2" -16 UNI Rough Chrome
Brass Jam Nut
Ä 1-1/2"-16 x 1-1/4" UNI Close Ell
with 3/8" NPT Clean-Out Plug
WASTE ASSEMBLY
51
4"
REF
21
4"
REF
27
8"
REF
8
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

VALVE INSTALLATION
!IMPORTANT
Before making up the supply
connections, the supply
lines must be flushed of all
foreign material such as
pipe dope, pipe chips,
solder, sand, etc.
DUAL TEMP. WITH -MXTP VALVE
for MXTP Valve (Hot & Cold), flush supply lines.
AConnect installer provided 1/2" NPS Flex Hoses to
Valve.
-03-M SINGLE TEMPERATURE
METERING VALVE
for -ST Single Temperature
Bvalves, flush supply line. Connect
installer provided 1/2" NPS Flex
Hose to Valve.
9
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

VALVE INSTALLATION & ADJUSTMENT
!IMPORTANT
Flush supply lines of all foreign material such
as pipe dope, pipe chips, solder, sand etc.
before making up supply connections.
NOTE: Installation should be in accordance with
accepted plumbing practices.
5) Turn on fixture and allow water to flow for 2
minutes. Measure water temperature at
outlet. If water is not at desired temperature,
adjust as necessary.
1) Locate suitable place for mounting the Valve
Assembly. Valve Assembly should be
accessible for service and adjustment and
as close to the point-of-use as possible.
Wall Anchors and Anchoring Hardware are
by others.
2) Connect hot and cold water to Supply
Valve using 1/2” NPTE connections.
3) Connect outlet of Tempering Valve to
Spout(s) using 1/4” O.D. Tube connections
provided.
4) Turn on hot and cold water supplies. If any
leaks are observed, hand-tighten
connections as necessary to stop leaks
before proceeding.
Valve Assembly Installation:
HINT: Angle Stops are recommended
and is the responsibility of the installer.
NOTE: Factory set temperature is 105º F
1) Loosen Locknut.
2) Turn on fixture and run water for at least 2
minutes. Allow supply temperature to
stabilize.
4) Tighten Locknut to prevent accidental or
unauthorized temperature adjustment.
5) Re-check outlet temperature.
3) Turn temperature stem counter-clockwise
for hotter or clockwise for colder outlet
temperature.
Temperature Adjustment:
LOCKNUT
WARMER
TEMPERATURE
STEM
10
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

VALVE CONNECTIONS
Ferrule Nut
1/4"
Min.
Ferrule
Nut
Leave a minimum 1/4” of Polyethylene Tubing
through the Ferrule Nut on the Pushbutton
Assembly. This is necessary to ensure proper
tubing connection.
turn Timing Screw
Timing Screw
To adjust timing,
Turn Timing Screw clockwise to
increase timing.
Do not over-tighten
ferrule nuts.
1/8" O.D. AIR TUBING
1/4" O.D. WATER TUBING
Instructions for Operation and Care of Best-Care WH3776
11
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

-SO Sensor Operation
Range Adjustment
2. Connect Power Supply to Sensor. Red light should
be flashing.
1. Make sure Power Supply is disconnected from
Sensor and make short circuit on red wires.
See DETAIL A.
4. Move hand to desired sensing distance.
See DETAIL B.
5. Hold hand at desired sensing distance until red light
stops flashing and Solenoid activates.
See DETAIL C.
3. Move hand in front of sensor to distance of 2” to 4”
within 5 seconds and wait until red light flashes
quickly.
DETAIL A
DETAIL B
DETAIL C
Transformer must
be plugged into a
GFI protected
circuit. Fixture must
be earth grounded
per N.E.C. or
applicable codes.
Jumper
By Others
-SO Sensor Operation or
-PPZ Programmable Piezo Pushbutton
SENSOR OPERATION & CONNECTIONS
-SO SENSOR
-PPZ PUSHBUTTON
RED BLUE
RED
BLUE
TRANSFORMER
SOLENOID VALVE
12
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

P-TRAP COVER INSTALLATION
Install P-Trap Cover using #10-32 UNF x 1/2” Center Reject Hex Head Screws provided.
Secure bottom of P-Trap Cover to wall with Anchoring Hardware (by others).
13
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

CONDITION: WATER DOES NOT FLOW
Probable Cause Solution
Water main closed Open water main
Checkstops closed Open checkstops
Debris or scale in Checkstop Strainer
. Remove Checkstop Strainer and clean
Air leaks from 1/8” O.D. Tubing or Fittings Replace damaged Tubing or Fitting
Pushbutton Air Diaphragm leaks Replace Pushbutton Air Diaphragm
Servomotor Diaphragm center hole is blocked
Servomotor Upper Diaphragm is damaged
Low or no water pressure at supplies Increase water pressure to 30 PSI minimum
CONDITION: WATER DRIPS, WON'T SHUT OFF
Probable Cause Solution
Servomotor Diaphragm offset hole is blocked
Servomotor Seat is damaged Replace Servomotor seat
Servomotor Plate or Diaphragm is obstructed
Servomotor Timer Assembly is damaged Replace Servomotor Timer assembly
Probable Cause Solution
Valve Riser Tubing is crimped Straighten Valve Riser Tubing
Debris or scale in Checkstop Strainer
. Remove Checkstop Strainer and clean
Blockage in Valve Flow Control Remove blockage
Low water pressure at supplies Increase water pressure to 30 PSI minimum
Lime deposits in hot water pipes
CONDITION: REDUCED WATER FLOW
Probable Cause Solution
Air leaks from 1/8" O.D. Tubing or Fittings Replace damaged Tubing or Fitting
Pushbutton Air Diaphragm leaks Replace Pushbutton Air Diaphragm
Remove blockage
Replace Servomotor Upper Diaphragm
Remove cause of obstruction
Remove blockage
TROUBLESHOOTING FOR OPTIONAL PUSHBUTTON OPERATED VALVES
Normal Valve Function: Pushbutton Operated Valve has an adjustable flow time from
5 to 60 seconds.
Remove lime deposits with appropriate
cleaning solution
CONDITION: PREMATURE WATER SHUT OFF
14
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

Acorn's Corterra densified solid surface material is
composed of recycled Solid Surface Polymer Resin,
Aluminum Trihydrate and Fillers. It is resistant to stains,
impact and burns and complies with ANSI Z124.3. It is
attractive, durable and easy to maintain.
lNylon or other soft-bristle brush
lHand dishwashing liquid / soft water solution
lClorox ®
Recommended Cleaning Materials:
CARE, CLEANING, AND REPAIR
OF CORTERRA SOLID SURFACE
Routine Cleaning
lMicrofiber Cloth
lSponge - natural or artificial
CARE AND CLEANING OF ENVIRO GLAZE/
POWDER COATING
lMild soap / soft water solution
Corterra should be kept clean at all times. If maintained,
Corterra surfaces will retain their new, clean appearance
indefinitely. Wash with a non-abrasive all purpose cleaner
and water, then rinse. Wipe dry. (Never use cleaners with
strong chemicals such as toilet bowl cleaners, rust
removers, ceramic cook top cleaners, laquer thinners or
oven cleaners). To remove persistent stains use a Scotch
Brite pad and an abrasive cleaner or a solution of
household bleach and water (1 part water to 1 part
bleach).
Surface damage, such as minor chips, scratches, burn
marks and graffiti can be repaired with a fine grit abrasive
cleanser, such as a Scotch-Brite pad or fine grit
sandpaper. For more serious physical damage caused by
vandals, an Acorn Solid Surface Repair Kit is available.
Contact the factory for details. Refer to drawing #9927-
160-002.
Recommended Cleaning Solutions:
Repairing Surface Damage
lSoft-Scrub ®
lComet Soft Cleanser ®
lScrubbing Bubbles ® Gel
For everyday cleaning, use a sponge or cotton cloth soaked
in mild soap and wipe-down surface. In industrial or marine
locations, close attention should be paid to regular care due
to harsher atmosphere.
To remove dirt and debris:
Fixture should be periodically washed with a diluted solution
of a mild non-abrasive detergent (e.g. Dawn ®) in cold or
ambient temperature water using a soft non-abrasive cloth
or chamois.
Normal Cleaning:
15
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

4953-001-000
1-1/2” OD Tubular P-Trap
P-Trap Cover
Ligature Resistant Elbow Strainer 4926-080-000
COMPONENTS & REPAIR PARTS
Description Part No. Diagram
ENCLOSURES
COMBINED WASTE ASSEMBLY
4970-180-001
1-1/4” OD Waste Bend Connection
Left
BU5CRN42-002
Right
BU5CRN40-002
(Shown)
1-1/2” Nylon Compression Washer 0431-125-000
1-1/2” IPS x 1-1/2” Slip Nut 4970-059-000
16
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

1/4" Lock Washer 0337-050-000
0331-005-000
1/4" Flat Washer
COMPONENTS & REPAIR PARTS
Description Part No. Diagram
ASSEMBLY HARDWARE
1/4"-20 UNC x 3/4" Hex Head Cap Screw 0206-008-000
#10-32 x 1/2” S/S Hex C/R Button Head
Screw, White 0112-044-000
ELECTRONIC HARDWARE
9 VDC Battery-Pak Assy
(6 AA Batteries Not Included)
Battery-Pak Mounting Bracket
0710-358-001
6155-013-199
9VDC Plug-In Transformer 0710-735-001
17
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

COMPONENTS & REPAIR PARTS
Description Part No.
VALVE
Diagram
2590-900-001
Optional -03-M Single Temp, Metering
Valve Assembly
Optional -03-M-MXTP, Single Temp,
Temperature-Pressure Balancing Mixing
Valve, ASSE 1070 Compliant
2590-901-001
Optional -04-M-MXTP, Hot & Cold,
Temperature-Pressure Balancing Mixing
Valve, ASSE 1070 Compliant
2590-911-001
Optional -04-M Hot & Cold, Metering
Valve Assembly 2590-910-001
-WH3376L
-WH3376L-MXTP
-WH3377L
-WH3377L-MXTP
18
Instructions for Operation and Care of Best-Care WH3776
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
This manual suits for next models
2
Table of contents