manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Williams
  6. •
  7. Furnace
  8. •
  9. Williams Gravity 1403622 User manual

Williams Gravity 1403622 User manual

Garage
Furnaces
14,000 Btu/hr
Williams' compact, space-saving direct-vent
furnaces feature low-cost installation.
These models feature a sealed combustion
chamber, which requires no inside air for
operation. . . making them an ideal choice
for adding comfort to your garage, workshop
or virtually anyplace where heat is needed.
With one of these popular garage furnaces,
create a comfortable and safe area to work
or park your car.
Design Features
"Matchless" pilot igniter
Easy installation -- all vent material included
Multi-room heating with optional outlet kit
(Counterflow models)
Attractive, durable scratch and abrasion
resistant epoxy powder-coat, soft-white finish.
Natural and propane models (Conversion kits
available)
These models require no electricity – great
during power outages. Provided with long-
life, ceramic-coated combustion chambers.
Direct-Vent Counterflow
Equipped with counterflow blower system to circulate
ceiling-to-floor warm air. Equipped with four-foot
service cord.
Direct-Vent
These totally automatic direct-vent models are
thermostatically controlled. Their attractive
styling is a durable scratch-resistant, soft-white,
epoxy powder-coat finish.
Attractive styling,
economical and safe
heating comfort with these
popular garage furnaces!
Attractive styling,
economical and safe
heating comfort with these
popular garage furnaces!
40,000 - 62,500 Btu/hr
14,000 - 30,000 Btu/hr
Natural Propane Thermal AFUE Width Depth Height
1403622 1403621 14,000 10,039 76.0 63.0 18" 7⅛" 26¾" 24" 56
2203622 2203621 22,000 16,462 75.0 67.0 32⅛" 10¼" 28" 24" 98
3003622 3003621 30,000 21,849 73.0 66.0 32⅛" 10¼" 28" 24" 100
4007332‡ 4007331‡ 40,000 32,000 80.0 75.0 14⅛"11¾" 77⅜"24" 126
4007732 4007731 40,000 32,000 80.0 75.0 14⅛"11¾" 77⅜"24" 126
5507332‡ 5507331‡ 55,000 44,000 80.0 76.0 14⅛"11¾" 87" 24" 140
6257732 6257731 65,500 50,000 80.0 76.0 14⅛"11¾" 87" 24" 140
Features
Direct-Vent Safety High-Capacity Blower
Side Outlet Accessories-
6801 Side-Outlet Re
g
ister with 10" Boot and Dam
p
er for counterflow models · 11 lbs
.
6802 Side-Outlet Grille for counterflow models · 2 lbs
.
Front Diffusing Grilles
A snap-on grille used to divert heat to the right, left or both directions fo
r
counterflow models only
.
6703 Two-Directional Diffuser Grille · 3 lbs.
6704 One-Directional Diffuser Grille · 3 lbs.
Venting Accessories
4318 Vent Shield Deflector · Insulated
,
g
alvanized metal sheet · 4 lbs
.
9301 15" Vent Extension for 22 and 30
,
000 Btu/hr Furnaces · 7 lbs
.
9302 24" Vent Extension for 22
,
000 Btu/hr Furnaces · 10 lbs
.
9303 24" Vent Extension for 14 and 30
,
000 Btu/hr Furnaces · 10 lbs
.
9304 15" Vent Extension for 14,000 Btu/hr Furnaces · 7 lbs
.
9307 Thin Wall Collar · Wall thicknesses from 1" to 5" · 4 lbs.
9308 Vent Ca
p
Guard · Protects
p
edestrian traffic from heat of the vent ca
p
· 3 lbs
.
9806 Counterflow Direct-Vent Tube Extension - 12" Len
g
th · 11 lbs
.
9807 Counterflow Direct-Vent Tube Extension - 15" Len
g
th · 11 lbs
.
9808 Counterflow Direct-Vent Tube Extension - 24" Len
g
th · 11 lbs
.
Finish Items
4701 Trim Strip Accessory · Metal finish moulding strips painted the same color as th
e
furnace · 4 lbs.
Conversion Kits -
Btu Size
14,000 8925 8928
22,000 8926 8929
30,000 8927 8930
40,000 7686 7693
55,000 7688 7695
62,500 7689 7696
High Altitude Models
Hard Wire Adapter -
24V Wall
Model 2303 for 14,000 Btu/hr
* Venting shipped with furnace for 5-9" wall thickness, 24" wall thickness available with use of extension accessories.
‡ Intermittent ignition Accessories
115V power supply required · 6 lbs.
Direct-Vent Counterflow with Electrical Service Cord
24V Wall
24V Wall
© 2006 Williams Furnace Co. Printed in U.S.A. All Rights Reserved L1171 5/06
Blower is easily added to the furnace. Comes with a fully automatic fan switch.
Natural to
Propane Propane to
Natural
Model 2302 for 22,000 and 30,000 Btu/hr
All models have ½" gas connection · All models are rated for 4,500' elevation.
24V Wall
Conversion Kit Available
Millivolt Wall
Millivolt Wall
Millivolt Wall
DimensionsEfficiency % Type
of
Control
Garage Furnaces
Model Number Btu/hr
Input
Rating
Btu/hr
Output
Rating
Maximum
Wall
Thickness*
Shipping Weight
(lbs.)
Important
· Read owner's manual before using/installing.
· Photographs are representative.
· Check local codes and ordinances for permitted uses.
· Consult installation manual for clearances prior to installation.
· We reserve the right to amend product specifications without notice.
· Installation and servicing recommended by a qualified service person.
· Venting must comply with the installation manual.
· New York approval MEA197-82E Vol 111 on direct-vent models only.
· Massachusetts approval G3-0305-171
· Please read the warranty for any limitations for disclaimers.
· Combustion chamber carries a ten-year limited warranty. All other
parts carry a one-year limited warranty.
2302
Dimensions and Clearances
Direct-Vent (14/22/30 Series)
2" from intersecting wall
18" from top of appliance to ceiling/overhang for 14,000 Btu/hr models
24" from top of appliance to ceiling/overhang for 22,000 and 30,000
Btu/hr models
Direct-Vent Counterflow (40/55/62 Series)
4" from intersecting wall
4" from top of appliance to ceiling/overhang
0" to finished floor
18" from centerline of vent cap on all sides
250 West Laurel Street · Colton, California 92324 USA
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009
Homeowner Assistance: (909) 426-0978
www.wfc-fc.co
m
COMBUSION
PRODUCTS
VENTED
TO OUTSIDE
COMBUSION
AIR FROM
OUTSIDE
OUTSIDE
COOL ROOM AIR
INSIDE
RADIANT EXT
HEAT
Air Circulation Pattern
WARM ROOM AIR
For clean, comfortable
heat when and where
you want it. The gas
flame is completely
sealed inside, away from
all contact with room air.
A
ir necessary for
combustion is drawn into
the chamber from
outside through direct
wall vent, and all
combustion products are
vented directly to the
outside. Only clean,
gentle heat, in
continuous circulation is
delivered into the room.
Windows and doors can
stay closed because no
room air is used for
combustion.
Automatic Thermostat - Included with all Models
Contemporary Finish
"Bird Guard"
"Matchless" Pilot Igniter
A
ll models include a "matchless" pilot igniter and a glass observation
door. Assures convenient pilot lighting without matches.
Light, soft-white powder-coat, scratch-resistant finish to blend
with any décor
.
A
ll vent caps include built-in "Bird Guard".
A
llows heat to be ducted into a side room
.
Current models only · 1 lb.
Model 994
0
8925
4701
7696
4318
6704
6703 6703

Other manuals for Gravity 1403622

4

This manual suits for next models

20

Other Williams Furnace manuals

Williams 4505622A User manual

Williams

Williams 4505622A User manual

Williams 1403621.05 User manual

Williams

Williams 1403621.05 User manual

Williams 2509621 User manual

Williams

Williams 2509621 User manual

Williams 2503532 User manual

Williams

Williams 2503532 User manual

Williams 4505621 User manual

Williams

Williams 4505621 User manual

Williams 7435 User manual

Williams

Williams 7435 User manual

Williams 6257731 User manual

Williams

Williams 6257731 User manual

Williams 3508732 User manual

Williams

Williams 3508732 User manual

Williams 2509622 User manual

Williams

Williams 2509622 User manual

Williams 3508331 User manual

Williams

Williams 3508331 User manual

Williams 4007332 User manual

Williams

Williams 4007332 User manual

Williams 4505622A User manual

Williams

Williams 4505622A User manual

Williams 1403821 User manual

Williams

Williams 1403821 User manual

Williams 4505621 User manual

Williams

Williams 4505621 User manual

Williams 743511 Installation instructions

Williams

Williams 743511 Installation instructions

Williams Gravity 1403622 User manual

Williams

Williams Gravity 1403622 User manual

Williams 3144030 User manual

Williams

Williams 3144030 User manual

Williams 1773512 User manual

Williams

Williams 1773512 User manual

Williams Gravity 1403622 User manual

Williams

Williams Gravity 1403622 User manual

Williams Gravity 1403622 User manual

Williams

Williams Gravity 1403622 User manual

Williams NOS 4505622 User manual

Williams

Williams NOS 4505622 User manual

Williams 5508332 User manual

Williams

Williams 5508332 User manual

Williams 0743512 User manual

Williams

Williams 0743512 User manual

Williams Gravity 1403622 User manual

Williams

Williams Gravity 1403622 User manual

Popular Furnace manuals by other brands

Carrier GAS FURNACE 58MXA Product data

Carrier

Carrier GAS FURNACE 58MXA Product data

Unitary products group PV9 installation manual

Unitary products group

Unitary products group PV9 installation manual

Lennox ML180DF045P24A Unit information

Lennox

Lennox ML180DF045P24A Unit information

Lennox ML180UH SERIES User's information manual

Lennox

Lennox ML180UH SERIES User's information manual

Bard FH110D48B installation instructions

Bard

Bard FH110D48B installation instructions

Heat Controller Comfort Aire GLUA45E3B installation instructions

Heat Controller

Heat Controller Comfort Aire GLUA45E3B installation instructions

Carrier 59SP2A Installation, start-up, operating and service and maintenance instructions

Carrier

Carrier 59SP2A Installation, start-up, operating and service and maintenance instructions

Ferroli DOMItech C 24 Instructions for use, installation and maintenance

Ferroli

Ferroli DOMItech C 24 Instructions for use, installation and maintenance

Lennox EL296UHE installation instructions

Lennox

Lennox EL296UHE installation instructions

Carrier 58MXA 170 Series Installation, start-up, and operating instructions

Carrier

Carrier 58MXA 170 Series Installation, start-up, and operating instructions

York PT8DH Technical guide

York

York PT8DH Technical guide

Bryant CONDENSING GAS FURNACE 355MAV Service and maintenance procedures

Bryant

Bryant CONDENSING GAS FURNACE 355MAV Service and maintenance procedures

MrCool Signature Series Owners & installation manual

MrCool

MrCool Signature Series Owners & installation manual

Sears NCGM Series installation instructions

Sears

Sears NCGM Series installation instructions

Tempstar NAHA00101MH installation instructions

Tempstar

Tempstar NAHA00101MH installation instructions

VERDER Carbolite Gero CTF 12/65/550 Installation, operation and maintenance instructions

VERDER

VERDER Carbolite Gero CTF 12/65/550 Installation, operation and maintenance instructions

Carrier Performance 59TP5A Series Product data

Carrier

Carrier Performance 59TP5A Series Product data

Carrier UPFLOW INDUCED-COMBUSTION FURNACES 58PAV quick start guide

Carrier

Carrier UPFLOW INDUCED-COMBUSTION FURNACES 58PAV quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.