Zemic BM-8-906 User manual

Installation Manual BM-8-906
Mounting Kit
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Page 1/5 www.zemiceurope.com
General
Please read this BM-8-906 Mount installation manual carefully in order to profit fully from the load cell
application.
Take care that the mounts and load cells are applied within their specifications. Certainly during installation,
special attention should be paid to exceptional forces exceeding these specifications.
Install the mount(s) in such a way that all bottom plates are at the same level and in the same horizontal plane.
The same goes for the top plates. Always check that the load cell and/or mount are not loaded with forces
exceeding their specifications.
If large load displacements can be expected, stay rods should be applied in order to limit uncontrolled side forces.
Always use shim plates to align mounts in the same horizontal plane and level.
Routine maintenance includes the optical inspection of bolts, plates and force bearing parts, as well as the removal
of dirt, dust and debris built up near or between the load cell and/or mount in order to let it move freely.
Capacity
Working height
Installation height
Mounting torque load cell
0.15 2t
120 mm
4.72 inch
120 mm
4.72 inch
100 Nm
74 Lb ft
2.5 5t
145 mm
5.71 inch
145 mm
5.71 inch
450 Nm
332 Lb ft
Dimensions:
Description
Dimensions 0.15 –2t
Dimensions 2.5 –5t:
Top Plate
140mm x 120mm
150mm x 150mm
Bottom Plate
200mm x 120mm
240mm x 150mm
Total Height
120mm
145mm
Hex Bolt for load cell fastening
M12 x 70
M18 x 80
Hex Bolt for adjusting lift off protection
M8 x 20
M8 x 20
Hex Bolt for lift off protection
M16 x 20
M16 x 20
Hex Bolt for transport plate/earthing cable fastening
M8 x 12
M8 x 12
Note: Please refer to the parts list on page 5 for an overview of all parts of the mount.

Installation Manual BM-8-906
Mounting Kit
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Page 2/5 www.zemiceurope.com
Detailed Specifications BM-8-906
Capacity with load cell
0.15t 2t
2.5 5t
Maximum vertical force (down) with dummy loadcell
15 kN
30 kN
Maximum vertical force (up)
15 kN
30 kN
Maximum horizontal force (with stay rod installed)
20 kN
40 kN
Maximum horizontal movement (without stay rod)
+1.5 / -1.5 mm
Assembly and Installation
Assembly:
-Make sure the upper and base plate are correctly aligned (vertically).
-Verify if the transport plate is mounted and already fastened tightly.
-Loosen the hexagon bolts which assembled the loadcell dummy to the base plate.
-Remove the dummy (load cell).
-Assemble the separate pressure piece in the loadcell.
-Apply some high pressure grease to the surface of the pressure installed in the loadcell.
-Install the loadcell in the mount. To do this, insert the loadcell under an angle and make sure the rocker
supports fit into each other.
-Make sure the spacer plate is located under the fastening end of the loadcell and put the bolts through
the loadcell, spacer plate and fasten them into the base plate.
-Note: If you want to assemble a stay rod, please install it to the side holes on the mount.
Installation:
-Please lift the container/silo with 1 to 2mm so that the mount(s) can be placed underneath.
-Locate the mount(s) into the application and secure using the four lower and four upper fixing holes.
-Remove the transport plate from the mount by removing the 4 socket head screws. See drawing.
-Lower the container/silo again, so that the weight now rests on the installed loadcell(s) in the mount(s)
-Install the earthing cable to one of the bottom plate holes of the transport plate and one of the holes of
the transport plate in the top plate, so that the top and bottom plate of the mount are connected.
-Now adjust the bolt and nut from the lift-off protection on the head side of the mount. Make sure the
ten the nut to the steel element.
-Only for assembly with stay rod: Secure the stay rod tightly, but make sure it does not apply any force on
the assembly!
-This is done by adjusting the middle part by rotating it. Now fasten the nuts on the sides of the middle
Isometric View
Remove the transport plate
once the actual loadcell has
been properly installed.

Installation Manual BM-8-906
Mounting Kit
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V.
T: +31 76 50 39480
Page 5/5 www.zemiceurope.com
Parts List BM-8-906
No.
Description
Quantity
Dimensions
0.15 –2t
Dimensions
2.5 –5t
1
Base plate
1
2
Top plate
1
3
Rocker support
1
4
Pressure piece (to be inserted in load cell)
1
5
Dummy loadcell / loadcell
1
6
Hex bolt for load cell fastening
2
M12 x 70
M18 x 80
7
Thin washer
2
8
Spacer plate
1
9
Inserts / Mounting holes for Stay-rod plate bottom
2
10
Inserts / Mounting holes for Stay-rod plate top
2
11
Hex bolt for adjusting lift off protection
1
M8 x 20
M8 x 20
12
Thin hex nut for lift off protection
1
13
Upper lift off protection
1
M16 x 20
M16 x 20
14
Hex bolt for lift off protection
1
15
Transport plate
1
16
Lower lift off protection
1
17
Hex bolt for transport plate/earthing cable fastening
4
M8 x 12
M8 x 12
-
Earthing cable
1
Please note: Part list above is only for mounting kit without stay rod.
Table of contents
Other Zemic Rack & Stand manuals
Popular Rack & Stand manuals by other brands

New Star Computer Products
New Star Computer Products CPU-D075BLACK/LK instruction manual

peerless-AV
peerless-AV Smartmount ST24D Installation and assembly

Belkin
Belkin RK4000ek instructions

ESDEC
ESDEC PANELCLAW clawFR 10 Degree installation manual

StarTech.com
StarTech.com CLAYTEK WOR-2740C manual

Husqvarna
Husqvarna CD 40 Operator's manual