a-gear P1004T EPON Manual

Hardware Installation Manual
A-GEAR P1004T EPON Optical Network Unit (ONU)
a-gear.net
Раge 1 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet

Content
1. Access Device 3
1.1. Description of outline in standard conguration . . . . . . . . . . . . . . . . . . . 3
1.2. Characteristic parameters of A-GEAR P1004T EPON System . . . . . . . . . . . . 5
1.3. ROHS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. Installation Preparation 6
2.1. Precautions for use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2. Safety Suggestions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2.1. Ensure safety in compliance with the following principles . . . . . . . . 6
2.2.2. Safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2.3. Operation Safety Principles for Live Parts . . . . . . . . . . . . . . . . . . . 6
2.3. General Requirements for Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3.1. Environment of the Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3.2. Precautions for Allocation of the Location. . . . . . . . . . . . . . . . . . . 7
2.3.3. Rack Conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3.4. Power Supply Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4. Installation tools and equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Installation of A-GEAR P1004T EPON 9
3.1. A-GEAR P1004T EPON Installation Flow. . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2. EPON access device installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2.1. Install the equipment on the desktop . . . . . . . . . . . . . . . . . . . . . 9
3.2.2. Mount the equipment on vertical wall surface. . . . . . . . . . . . . . . . 9
3.3. Connecting ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3.1. GEPON SFF Optical Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3.2. Ethernet Electrical Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.4. Check after installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4. Maintenance of EPON Access Device 11
4.1. Open the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2. Close the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5. Analysis of Hardware Failure 12
5.1. Failure Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1.1. Power failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1.2. Failure in port, cable and link . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2. Description of indicator lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
a-gear.net
Раge 2 of 13
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
A-GEAR World Wide Manufacturing

1. Access Device
This chapter mainly describes and introduces overall characteristics and parameters of
A-GEAR P1004T EPON access device so that readers can get an overall understanding about
A-GEAR P1004T EPON.
1.1. Description of outline in standard configuration
A-GEAR P1004T EPON interface consists of the following parts: 4 100-MB RJ45 ports, 1
GEPON optical port, 1 Power port, 1 switch, 1 Reset and 1 ground point. See following table
for detailed description.
Table 1-1. Characteristics of the Ports
Port name Description
LAN1~4 RJ45 100MB Ethernet port, link cable
GEPON optical port SFF, link optical fibre
Power port Link power supply
Switch switch Control device switch
Figure 1-1. Front Panel View of A-GEAR P1004T EPON.
Table 1-2. Description of Front Panel Components of A-GEAR P1004T EPON
Component
No.
English
name Chinese name Description
1LAN1~4 RJ45 Ethernet Port 100MB Ethernet port, connecting
Ethernet cable
2PON GEPON optical port SFF INTERFACE, connecting optical fibre
3RST Reset key Used for reset operation of the
equipment
4POWER Power supply port Connecting power supply, used to
supply power for the equipment
5SWITCH Power switch Switch of the control device
6— Ground point Through the screw of this point, the
equipment outer casing is grounded
a-gear.net
Раge 3 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet

Figure 1-2. Back Panel View of A-GEAR P1004T EPON.
Table 1-3. Description of LEDs on Back Panel of A-GEAR P1004T EPON
LED lamp code Quantity Color Status Description
POWER lamp 1 Green Off ONU is not switched on
on ONU Normally switched on,
PON lamp 1 Green
Off Indicating that ONU does not complete
MPCP and OAM discovery and registration
Flash Indicating that ONU is trying to establish link
Normally
on
Indicating that MPCP and OAM links of ONU
have been activated
LOS lamp 1 Red
Off Indicating that ONU received light power is
normal
Flash Indicating that ONU received light power is
lower than the sensitivity of the light receiver
ALARM lamp 1 Green
Off After being normally switched on, it operates
normal
Normally
on
After being switch on, failure occurs in
software operation
LAN1-LAN4
lamp 4 Green
Off
Not switched on, or Ethernet cable is not
plugged or link is not established after being
normally switched on
Flash
After being normally switched on, Ethernet
Port successfully establishes link and has data
transfer
On After being normally switched on,, Ethernet
Port successfully establishes link
a-gear.net
Раge 4 of 13
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
A-GEAR World Wide Manufacturing

1.2. Characteristic parameters of A-GEAR P1004T EPON System
Protocol standard Supporting standard
IEEE Std 802.3-2005 IEEE Std 802.1D-2004 IEEE
Std 802.1Q-2005
Technical requirement for China Telecom EPON
equipment
YD/T 1475-2006
Hardware
characteristics
Memory Flash Memory: 4M Bytes; PSRAM: 2Mbytes;
Standard configuration 4 10/100BASE-Tx ports 1 GEPON optical port 1
Reset key 1 POWER port 1 switch key
Overall dimension 165*128*33mm
Operating
temperature/humidity -5°C~45°C; 5%~95%, without coagulation
Storage temperature/
humidity -40°C~60°C; 5%~95%, without coagulation
Characteristic of power
adapter
Input voltage: AC110V-240V, 50/60Hz Output
voltage: DC12V/0.7A
Power consumption Max. 7W
1.3. ROHS Description
Parts Toxic or harmful substances or elements
Pb Hg Cd Cr (VI) РВЕ PBDE
Chasis OOOOOO
Rack OOOOOO
Baseboard OOOOOO
Module OOOOOO
Interface Card OOOOOO
0: The toxic or harmful substances` levels in each homogeneous materials of each part, are under the limitation of
SJ/T 11363-2006 regulation
X: The toxic or harmful substances` levels at least in one homogeneous materials of one part, exceed the limitation
of SJ/T 11363-2006 regulation
a-gear.net
Раge 5 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet

2. Installation Preparation
2.1. Precautions for use
Similar to other electronic products, quickly and frequently turning on/o power supply will
damage semi-conductor chip. When you need to re-start A-GEAR P1004T EPON, please turn
on power switch again 3~5 seconds after it is switched o.
Please do not violently impact A-GEAR P1004T EPON or drop it from a high place, which
may damage internal hardware of .EPON access device.
Please use correct external ports to connect A-GEAR P1004T EPON. Improper operation will
cause damage to internal elements of the port.
Note:
[1] Please insert /pull o power line plug in the direction of power socket!
[2] When the service life of the product expires, please do not discard it at will. To prevent from environmental
pollution, please dispose it according to related national laws and regulations, or send it to our company for
uniform disposal!
2.2. Safety Suggestions
2.2.1. Ensure safety in compliance with the following principles
• During the course of equipment installation and after installation is completed, please
keep if dust-free and clean;
• Place the machine in a safe place;
• Place the tools in a place not easy to drop by touch;
• Do no wear loose clothes to avoid being stumbled by the equipment. Tie up necktie or
scarf and scroll up sleeves.
• If the environment may damage eyes, please wear safety goggles;
• Do not conduct operations that may cause personal injury or damage to the equipment.
2.2.2. Safety warnings
Safety warnings in this section refer to the warnings against personal injury that may be
caused in the case of improper operation.
• Carefully read the installation guide, and then carry out operation on the system;
• Only those trained, qualied personnel can install or replace EPON access
• device;
• Before operation on the equipment, please cut o the DC connection;
• Final conguration of the product must comply with all applicable national laws
• and regulations.
2.2.3. Operation Safety Principles for Live Parts
When working on live parts, the following principles are applicable:
• Before operation on live devices, take o jewelries (such as nger ring, necklace,
• watch, bracelet, etc.). When metal object contacts «power» and «ground», it may
a-gear.net
Раge 6 of 13
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
A-GEAR World Wide Manufacturing

• cause short circuit or damage to the elements.
• Before operation on the equipment, cut o DC power supply.
• Improper connection between equipment and power sockets may cause hazard.
• Only those trained, qualied personnel can carry out operation and maintenance
• on the equipment.
• Before the system is switched on, please carefully read installation guide.
Note:
[1] Carefully observe potential hazard, such as damp oor, non-grounded power
[2] extension cable, worn power cable
[3] Place the emergency switch in the workroom so that power can be rapidly cut
[4] o when accident occurs
[5] Before installation/disassembly of the equipment, pull o the power cable
[6] Please do not work independently if there is potential hazard
[7] Before check, always cut o power supply
[8] If accident occurs, please take the following measures
[a] Switch o the system
[b] Give alarm
[c] Judge whether the aected person needs [articial respiration or not, and then take proper measures
[d] Where possible, send a possible to seek for medical help; otherwise seek for help according to serious degree
2.3. General Requirements for Location
This part discusses the requirements for the location of safe installation and use of the
system. Before installation, ensure that the location has been properly prepared.
2.3.1. Environment of the Location
By adoption of card-track installation method, EPON access device can be xed on DIN card
track. The equipment adopts fan-free design. Please note that installation environment
should be well-ventilated to facilitate equipment heat dispersion.
When planning location arrangement and equipment placement, please remember to
discuss the precautions as set forth in «Precautions for Allocation of the Location». If the
equipment often breaks down or error often occurs, such precaution information may help
you isolate failure and avoid recurrence of the problem.
2.3.2. Precautions for Allocation of the Location
Precautions listed below may help you design a suitable environment for EPON access
device to avoid system failure caused by the environment.
• Ensure air is well circulated and electrical equipment heat is well dispersed in the work
room. Air circulation must be sucient to provide a good cooling environment;
• Equipment should be better placed in such a way that cool air frequently passes by the
equipment. Ensure the outer casing of the equipment is complete and xed. If it is open,
air circulation inside the equipment will be damaged, which may interrupt airow or
change the direction of the cool air that should cool down heat-emitting the internal
elements.
a-gear.net
Раge 7 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet

2.3.3. Rack Configuration
The following content helps you design a suitable rack conguration.
• Each equipment on the rack will emit heat during working. To ensure good ventilation,
closed rack must be provided with heat dispersion port and cooling fan, and equipment
should be closely placed from each other;
• When installing equipment on the open rack, pay attention not to make the rack frame
obstruct the vent holes of EPON access device. Please carefully check the equipment
location after the equipment is installed to avoid such case.
• Ensure that eective ventilation measure has been provided for the equipment installed
at the lower part of the rack.
2.3.4. Power Supply Consideration
Check power supply. Ensure that power supply system is well grounded. Input voltage
range should be AC110V~240V. Too high voltage will damage the machine.
Warning:
If the power supply system is not well grounded, or input power uctuates greatly with excessive pulse, false code
rate of the communication equipment will increase, or even hardware system will be damaged!
2.4. Installation tools and equipment
Tools and equipment required for installation of A-GEAR P1004T EPON are not included in
standard conguration of A-GEAR P1004T EPON. User needs to prepare them by himself.
The following are typical tools and equipment required for installation of A-GEAR P1004T
EPON:
• Screw driver
• Anti-static hand ring
• Fastening screws
• Ethernet cable
• Other Ethernet terminal equipment
• Control terminal
a-gear.net
Раge 8 of 13
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
A-GEAR World Wide Manufacturing

3. Installation of A-GEAR P1004T EPON
Warning: Only those trained, qualied personnel can install or replace the equipment.
3.1. A-GEAR P1004T EPON Installation Flow
Start
Preparatory works
Install at specied
location
Connect the cable
Checkup
Power on
Congure
Over
3.2. EPON access device installation
EPON access device may be placed on at desktop or mounted on vertical wall
surface. Operation according to the steps in this section can well satisfy you
requirement for network installation. The content is divided into the following parts:
• Install the equipment on the desktop.
• Mount the equipment on vertical wall surface.
3.2.1. Install the equipment on the desktop
A-GEAR P1004T EPON may be directly placed on smooth, at and safe desktop.
Note: Do not place too heavy object (1Kg) on the top of the EPON access device, otherwise it will be damaged.
3.2.2. Mount the equipment on vertical wall surface
By way of the bottom clamping slot, EPON access device may be xed on vertical wall
surface provided with fastening screws During operation, just insert the clamping on the
back panel of the machine onto the screws. Please ensure there are at least more than two
screws and conrm their tightness.
a-gear.net
Раge 9 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet

3.3. Connecting ports
3.3.1. GEPON SFF Optical Port
A-GEAR P1004T EPON provides 1 GEPON SFF port. Indicator lamps corresponding to this
port are PON and LOSS. During use, connect SC optical bre to the port, and then to optical
splitter and then from optical splitter to OLT equipment.
3.3.2. Ethernet Electrical Port
A-GEAR P1004T EPON provides 4 10/100Base-Tx ports. During use, connect UTP port of
EPON access device to other Ethernet terminal equipment through network cable (direct
connection or cross). See following table for No., sequence and arrangement of UTP port
pins.
Figure 3-1. RJ-45 Connector.
As all of the four 10/100Base-Tx ports of A-GEAR P1004T EPON support MDI/MDIX self-
recognition function of the cable, when connecting A-GEAR P1004T EPON with other
Ethernet terminals, either Class V direct network cable or Class V cross network cable may be
used, which facilitates the selection of cable.
Table 3-3. Table of Denition of 1000MB RJ45 Pins
Pin No. Pin name English name Remarks
1Positive phase terminal of data transfer TXD1 + output
2Reverse phase terminal of data transfer TXD1- output
3Positive phase terminal of data receipt RXD1 + input
4Positive phase terminal of data transfer TXD2+ output
5Reverse phase terminal of data transfer TXD2- output
6Reverse phase terminal of data receipt RXD1- input
7Positive phase terminal of data receipt RXD2+ input
8Reverse phase terminal of data receipt RXD1- input
As supporting self-recognition function of the direct/cross network cable, either Class
V direct network cable or Class V cross network cable may be used to connect
A-GEAR P1004T EPON with other Ethernet equipment.
a-gear.net
Раge 10 of 13
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
A-GEAR World Wide Manufacturing

3.4. Check after installation
After mechanical installation of EPON access device is completed, please make the
following check before starting EPON access device:
• If EPON access device is mounted on vertical wall surface, please check the installation
reliability of EPON access device. It installed on desktop, please check if space reserved
around EPON access device is sucient for heat dispersion and if desktop is stable or
not.
• Check if power supply connected is consistent with that required for EPON access device
or not.
• Check if the ground wire of EPON access device is properly connected or not.
• Check if EPON access device is properly connected with other equipment or not, such as
conguration terminal.
4. Maintenance of EPON Access Device
Warning:
[1] Before opening the equipment, ensure that static electricity that you carry has been released and power switch
of EPON access device has been turned o. Before carrying out any step in Annex B, please read the part «Safety
Suggestions»;
[2] When you are near power supply or operate the equipment, please turn o power switch and pull of power cable
at rst.
4.1. Open the equipment
This part mainly describes method, tools required and operation steps for opening the cover
of EPON access device.
Warning:
When power cable is connected, do not touch it with bare hand to avoid getting an electric shock.
a-gear.net
Раge 11 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet

Disassembly of the equipment may require some tools, which are not included in standard
conguration of EPON access device. These tools are as follows:
• Cross screwdriver
• Anti-static hand ring
Pleas open the cover of EPON access device according to the following steps.
(1) Pull o power cable of EPON access device;
(2) Pull of all cables connected to EPON access device ports;
(3) Release screws on the equipment outer casing with screwdriver;
Note: The equipment outer casing consists of two parts: equipment cover and equipment base.
(4) Remove the cover in the direction of the arrow as shown in the following gure
(5) When the cover is opened, put it aside. The system mainboard appears.
Note:
After removal of the cover, place it stably to avoid squeezing, collision or deformation, otherwise installation of the
equipment will become dicult.
4.2. Close the equipment
This part mainly describes the ow for placing cover and closing the equipment.
Please operate according to the following steps:
(1) Install the equipment cover and base in place according to the direction and
steps in 4.1-(4).
(2) Re-install the screws and tighten them with screw driver.
(3) Re-install EPON access device or place it on the desktop.
(4) Equipment closing work is completed. Re-connect all cables.
5. Analysis of Hardware Failure
This section describes method for failure analysis and isolation of failure from EPON access
device:
5.1. Failure Isolation
The key to settle system failure is to isolate failure from the system. Failure isolation and
settlement becomes easy by comparison between what the system should do and what the
system is doing. The following sub-systems should be considered in solving the problems:
• Power connection;
• Port, cable and link - ports on the front panel of EPON access device and cables
connected to the ports.
5.1.1. Power failure
Check the following items to facilitate isolation of problems:
• Conrm that power cable is reliably connected and power is supplied.
• Check the environmental conditions. Note that temperature required for work location
of EPON access device should be -5°C ~ 45°C.
a-gear.net
Раge 12 of 13
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
A-GEAR World Wide Manufacturing

• If power supply is normal for a certain circuit of EPON access device, the power indicator
lamp Power should be lit, otherwise power supply for this circuit is abnormal. When the
system is normally registered on OLT, PON lamp should be lit and LOS lamp should be
o.
5.1.2. Failure in port, cable and link
Check the following items to facilitate isolation of problems:
• If EPON access device port cannot be linked, check if the link cable is correct and if
opposite terminal connection is normal or not.
5.2. Description of indicator lamps
LED indicator lamps indicate the current operation of EPON access device. A-GEAR P1004T
EPON indicator lamps and the description are as follows:
LED lamp code Quantity Color Status Description
POWER lamp 1 Green Off ONU is not switched on
on ONU Normally switched on,
PON lamp 1 Green
Off Indicating that ONU does not complete
MPCP and OAM discovery and registration
Flash Indicating that ONU is trying to establish link
Normally
on
Indicating that MPCP and OAM links of ONU
have been activated
LOS lamp 1 Red
Off Indicating that ONU received light power is
normal
Flash Indicating that ONU received light power is
lower than the sensitivity of the light receiver
ALARM lamp 1 Green
Off After being normally switched on, it operates
normal
Normally
on
After being switch on, failure occurs in
software operation
LAN1-LAN4
lamp 4 Green
Off
Not switched on, or Ethernet cable is not
plugged or link is not established after being
normally switched on
Flash
After being normally switched on, Ethernet
Port successfully establishes link and has data
transfer
On After being normally switched on, Ethernet
Port successfully establishes link
a-gear.net
Раge 13 of 13
A-GEAR World Wide Manufacturing
A-GEAR P1004T EPON Optical Network Unit (ONU)
datasheet
Table of contents
Popular Wireless Access Point manuals by other brands

Cisco MERAKI
Cisco MERAKI MR33 installation guide

Netgate
Netgate Wireless Multi-Client Bridge user manual

ZyXEL Communications
ZyXEL Communications ZYAIR G-1000 Quick installation guide

Ruijie
Ruijie RG-SAP825-SP Hardware installation and reference guide

lohuis networks
lohuis networks LOHU 2527L user manual

Xirrus
Xirrus XR-520 user guide

D-Link
D-Link NUCLIAS CONNECT DAP-2680 Quick install guide

Allnet
Allnet ALL-WAP0305AC manual

Edge-Core
Edge-Core Spark SP-W2-AC1200 quick start guide

Cisco
Cisco Aironet AIR-AP1200 Hardware installation guide

SonicWALL
SonicWALL TZ500 W Safety and regulatory information

Edimax
Edimax EW-7228APn Quick installation guide