INSTALLATION INSTRUCTIONS
Hy-Ex 1.0K & 1.4K
Exterior Wall or Roof Mount Ventilator
PLEASE READ AND SAVE THESE INSTRUCTIONS
IMPORTANT: SavetheseinstructionsfortheLocal Electrical Inspector’suse.
INSTALLER: PleaseleavetheseInstallationInstructionswiththisunitfortheowner
OWNER: Pleaseretaintheseinstructions for future reference.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer.
2. Before installation, servicing or cleaning unit, switch
power off at the service panel and lock the service discon-
necting means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
by qualified person(s) in accordance with all applicable
codes including fire rated construction.
4. Sufficient air is needed for proper combustion and ex-
hausting of gasses through the flue (chimney) or fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturers guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities
5. When cutting or drilling into wall and ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7.
To reduce the risk of fire, use only metal ductwork.
8. This fan should only be used with the fan speed control
provided by ABBAKA for this model. The ventilator must be
installed such that the exhaust discharge is 12” minimum from
the ground level. However there may be some local codes that
do not permit this type of installation. Heavy snowfall may
prevent the damper from opening due to snow blockage. In-
staller should check local codes for outdoor wall installation.
Caution: For general ventilation use only. Do not use to
exhaust hazardous or explosive materials and vapors.
Installation Tips
1. For lowest noise operation, place 1 elbow between the range
hood and the ventilator. Install an optional ABBAKA Accoustical
Duct Silencer.
2. Select an installation location that is free of obstacles such as
heating and air conditioning ducts, stand pipes, electrical wiring,
etc.
3. Position discharge of the ventilator downward and away from
prevailing winds to minimize backdrafts.
4. For best appearance, locate the fan on the rear of the house,
below the top of roof line.

ArchitecturalKitchenRangeHoods
P.O. Box 215 Bodega Bay, CA94923 (800) 548-3932 Fax (800) 548-3930
E-mail:web[email protected] http://www.abbaka.com Page2
IA-031 8/03
Model Number: HYEX-1.0K/HYEX-1.4K
Maximum CFM: 1000 CFM/1400 CFM
Volts: 115VAC
Hertz: 60Hz
Amps: 3.3 Amps
RequiredDuctSize:
HYEX-1.0K: 8” Round (51 sq. in. equivalent)
HYEX-1.4K: 10” Round (80” sq. in. equivalent)
Flat or Low Slope Roof
1. Forflat roofs orroofs having apitch
lessthan11/2”risein12, mount ventila-
tor on roof curb. See Figure 1.
2"
23"
25 5/8"
2. Installtheventilatorwithdischargepointingdown
slope and away from prevailing winds.
3. Useflashingand roofing mastic tosealtheunit
topreventleaks.
4. Cutholesfor ducting and electricalwiringas
showninFigure2
Figure 1
Typical Roof Mount
1. Centertheductcutoutbetweenroofrafters.
2. Installtheventilatorsoits discharge is down
slopeandaway from prevailing winds. According
totheStandardRoofing Procedures: (shingles
mustcoverrearflashingflangeandaminimumof
1’ofthe side flanges. The flashingonthe dis-
chargesideofthe ventilator must rest on topofthe
shingles.
3. Theventilatormustbesealedbetweenthe roof
anditsundersidewithquality roofing mastic.
Figure 2
PREPARE LOCATION & INSTALL VENTILATOR
9"
25 5/8"
22 13/16" 7"
26 1/2"
12 3/4"
11 1/2"
7 1/2"
4 1/4"
25 5/8"
23"
26 1/2"
Cut-out: Ø9" or Ø11 in
Cut-Out: Ø1 1/4 in
Top View
22 13/16"
Roof or Wall Down Slope

ArchitecturalKitchenRangeHoods
P.O. Box 215, Bodega Bay, CA94923 (800) 548-3932 Fax (800) 548-3930
E-mail:web[email protected] http://www.abbaka.com Page3
IA-031 8/03
VENTILATOR
Range Hood
Black
White
Wht
Grn
115Volt 60Hz
PowerSupply
Capacitor
Green/Yellow
(Ground)
Brown
White
Black
Blue
Black
MOTOR LEADS
Green
White
Black
Figure 3
Figure 4
DUCT CONNECTIONS
WARNING:Toreduceriskoffire,useonlymetal
ductwork.
1. Use only round metal duct, elbows and transi-
tions;orrectangularductinghavingequivalent
area of square inches as per required duct size.
2. Tapealljointswithducttape.
3. Turn on power and check ventilator operation.
4. Makesure damper opens andclosesfreely.
WARNING: Turnoffpower at theservicebox
beforewiring.
1. Power supply for the ventilator is 115VAC 60
Hz. See page 2 for specifications.
2. Runelectricalcablebetweentheventilatorand
therangehoodorventilatorand wall switch. See
Figure 3
3. Removetopenclosureoftheventilatorforac-
cesstothewiring terminal block.
4. Pushtheelectricalcableupthroughthebottom
knockoutoftheventilatorbody. Pullenoughwire
upintothe housingtomakeattachmenttothe
terminalblock.
5. Connect whiteto“NEU”, green to “GND” and
red speed control wire to “LINE”. See Figure 4.
ELECTRICALCONNECTIONS

ArchitecturalKitchenRangeHoods
P.O. Box 215, Bodega Bay, CA94923 (800) 548-3932 Fax (800) 548-3930
E-mail:web[email protected] http://www.abbaka.com Page4
IA-031 8/03
SEVEN (7) YEAR WARRANTY
ABBAKA will repair or replace any part of your
productthathasafactorydefectinworkmanship
ormaterial. Productmust be returned to pointof
purchase,withBillofSale,withinseven(7)years
ofpurchase. Iffactoryreturnisrequired,as
determinedbydistributor/dealer,thewarrantee
assumesallcosttoandfrom factory.
The Following Warranties Do Not Apply:
A. To damages from shipping, either concealed
orvisible; B.To damagesresultingfrom improper
wiringorinstallation.
C. To damages or failure caused byActs of God,
orresultingfromimproperconsumerprocedures
suchas 1)improper maintenance, 2) misuse,
abuse,abnormal use, or accidentand 3)incor-
rect electricalvoltageorcurrent;
D. To removal of or any alteration to theABBAKA
label,controlnumberor dateofmanufacture;
E.To any other warranty, expressed, implied or
written,andtoanyconsequentialorincidental
damages,lossofproperty, revenues, or profit or
costsofremoval,orreinstallation,foranybreach
ofwarranty.
Warranty Validation
Theend user must keepa copy of theBill of Sale
toverify purchase date. Valid proof of thedate of
installationmayalso serve as a verificationof
commencementofwarrantyperiod.
ABBAKA RETURN POLICY
Claims for damages or shortages must be reported
withinten(10) days of receiptofproducts(s). For
anyproduct(s)receiveddamagedbythe forwarding
agent,THEFOLLOWINGINSTRUCTIONSMUST
BE FOLLOWED:
1) For products delivered by UPS: a) Concealed
Damages: Keep all cartons and fillers. Call UPS for
an inspection and notifyABBAKAimmediately.
b) Visible Damages: Save all cartons and fillers and
filecomplaintdirectlywithUPS.
2)For product deliveredvia a common carrier, file
damagedgoodsclaim directly with thefreightcom-
pany.
3)Shortages: Signonlyforthetotalnumberof
pieces received and call ABBAKA immediately.
FOR FACTORY RETURN
PRODUCT(S)RETURNEDWITHOUTAUTHORIZA-
TION WILL NOT BE ACCEPTED. ABBAKA WILL
NOTACCEPTTHERETURNOF ANY SPECIAL,
NON-STOCK,OBSOLETEOR UNSALABLE
PRODUCT(S). ABBAKAMAY,ATITS OPTION,
ACCEPT RETURN OF SALABLE PRODUCT(S)
SUBJECTTOA 25% RESTOCKING CHARGE.
1)Noproduct(s)willbeacceptedwithouta Return
GoodsAuthorization(RGA)number. The number
can be obtained by calling ABBAKA at 800-548-
3932. Please have Bill of Sale or proof of date of
installationavailable.
2)RGAmustbeclearly marked on outside of carton
ordeliverywillberefused. All product(s) must be
returnedfreightprepaid.
3)Product(s) will be repaired/replaced and shipped
backto buyer; no creditwillbe issued.
4)Anyoutofwarrantyproductwillbeevaluatedand
buyerwill be notified of cost; repair cost willbe
chargedtocustomer;buyerwill be responsible for
returnfreightorproductmay be returnedwithout
action,tothebuyer,freight collect. No credit will be
issued.
UL UL
C
FILE # E157161
This manual suits for next models
1
Table of contents
Popular Fan manuals by other brands

Carrier
Carrier 39CZ Installation, operation and maintenance instructions

Home Decorators Collection
Home Decorators Collection BETHEL 52-BETL Use and care guide

Convair
Convair CoolTower CTF09 owner's manual

Tunze
Tunze Aquawind eco chic 7028.500 Instructions for use

Westinghouse
Westinghouse WSFTBJY39 instruction manual

Fanimation
Fanimation FP8032DZ owner's manual