Evaporative air cooler user’s instruction manual
Please keep the user’s instruction manual for reference.
Please read this instruction manual carefully before using the product.

1
CONTENT
Ⅰ、Product Introduction----------------------------------------------- 1
Ⅱ、Specifications--------------------------------------------------------- 2
Ⅲ、Range of Application------------------------------------------------2
Ⅳ、Using Environment------------------------------------------------- 2
Ⅴ、Circuit wiring Diagram ------------------------------------------- 3
Ⅵ、Operating Instruction --------------------------------------------- 5
Ⅶ、Installing and Using Instruction------------------------------- 6
Ⅷ、Maintenance Instruction------------------------------------------ 6
Ⅸ、Common Faults and Troubleshooting------------------------- 7

2
Ⅰ、Product Introduction
Evaporative air cooler is a kind of modern energy-saving product which is developed
through years of research and experiments. It has the following advantages:
1. Energy-saving: Up to 80% or more while comparing with traditional air-conditioner
2. Environmentally friendly: No use of refrigerants to create the cooling effect.
3. Efficient: Low electrical usage comparable to an exhaust fan but with cooling effect.
Its working principle is a "direct evaporative" humidification and cooling technology,
which not only has a cooling function but also can achieve air humidification.
Continuously circulating pump draws water from the water tank, and then the water is
distributed to the cooling pads. When the hot air enters into the cooling pads,
evaporation of water in the pads occur cooling the hot air before it enters the greenhouse.
Ⅱ、Specifications
Ⅲ、Range of Application
As the remarkable advantages of evaporative air cooler in cooling, humidification,
cleanness, energy-saving and ventilation, it is used in ventilating and cooling many
places like greenhouses, shops, homes, livestock barns, warehouses, etc.
Ⅳ、Using Environment
1. Environment Relative Humidity: ≤95%
2. Atmospheric pressure: 86kpa~106kpa
3. 0℃<Water supply temperature<45℃, water supply pressure: 0.15~0.6mpa
Cooler Model 3500VK
VABW06-EQ
5800VK
VABW10 - EQ
Voltage/Frequency 110V/60Hz 110V/60Hz
Working Current 1.6 amps 2.36 amps
Water Consumption 1 ~ 2 gal/h 1 ~ 2 gal/h
Outlet Size (in.) 17” × 17” 17” × 17”
Noise 58dB 63dB
Max Air Volume 3500 CFM 5800 CFM
Power 180W 260W
Water Storage 6.5 gal 10.5 gal
Weight 55 lbs. 77 lbs.
Fan Type Axial Fan Axial Fan

3
V、Operating Instruction
1. The operating instruction of control panel (Picture 1)
(1)ON/OFF
Plug cooler in, and press this button to turn on the air cooler. During the initial use,
the default setting is in the “cool mode”. Press button again to cut the unit off (turns
off fan motor, pump and display).
(2)COOL/FAN
Press this button to select COOL mode (fan and water pump are both on) or FAN mode
(only fan is on). The lights on the control panel will indicate which mode the cooler is
in.
The COOL light will light up, after 30 seconds, fan motor will start working.
(3)Speed
Press this button to adjust the fan speed. Choose from low, medium and high.
(4)Swing
Press this button to make the louvers oscillate left and right.
(5)Clean
This button is not used or needed on this model.
Picture 1

4
2. Operation of remote controller (Picture 2)
(1)ON/OFF
Plug cooler in, and press this button to turn on the air cooler. During the initial use,
the default setting is in the “cool mode”. Press button again to cut the unit off (turns
off fan motor, pump and display).
(2)COOL/FAN
Press this button to select COOL mode (fan and water pump are both on) or FAN mode
(only fan is on). The lights on the control panel will indicate which mode the cooler is
in.
The COOL light will light up, after 30 seconds, fan motor will start working.
(3)Speed
Press this button to adjust the fan speed. Choose from low, medium and high.
(4)Swing
This button makes the louvers oscillate left and right.
(5)Clean
This button is not used or needed on this model.
Picture 2
3. Audible alerts
(1) Each time you press a button on the remote, a buzzer will ring. The operation of
remote control is the same as control panel.
(2) When the water level is below the warning level, the water pump will stop running
and the buzzer will ring, and it will return to work after water is added.

5
VI、Installing and Using Instruction
1. The unit must be installed outside or in the area with enough return air volume and
0.15~0.6 m/pa water pressure.
2. The unit for open area using, if it working in closed area, must open the vent to keep
balance between the air input and displacement.
3. Before installing the air cooler support in the outside wall, draw a horizontal line with
level ruler firstly to keep the support level, controller put higher 2m than floor, support
welding and installing must be stable, which can bear no less than 200 kg of dynamic
load, and then put the item on the support. If higher 3m than floor, adding barrier.
Lastly connect the PVC pipe with speed glue to keep smooth for water inlet and outlet.
air cooler unit
installing support 出风口
墙体或其它建筑物
4. Operation and maintenance
(1)In high humidity season, it is better to choose wind mode as there is humidifying
effect in cool mode.
(2)After adding water, do not let machine tilt, collide, laid or move to any position that
will make the water overflow. Do not overturn the machine.
(3)Do not cover the air outlet, a clear space of at least 3 feet should be provided in
front of the air outlet and around the cooling pads.
(4)Please remember to unplug the machine before cleaning or maintenance.
(5)Clean the shell with a wet rag. Don`t flush it with water directly.
(6)If the machine is overturned with water in it, pull the power plug immediately. You
should only re-start the machine after it thoroughly dries out, otherwise, it may
malfunction.
Air outlet
Wall

6
(7)Don’t keep the air outlet close to walls or window curtains cause the air will be
blocked.
(8)If the machine is not in use, please pull the power plug.
VII、Circuit Wiring Diagram for PCB
Ⅷ、Maintenance Instruction
Turn the power off before maintenance or repair of the machine so as to prevent
accidents due to illegal operation. To ensure the cooling effect of the machine, the
machine body should be cleaned by water every day or every week. The interior of the
machine shall be also cleaned regularly, and the proper cleaning interval is one month;
however, the actual cleaning time will vary depending on the exterior environment.
1. Instructions for cleaning the interior of the air cooler
(1) Turn off the power and loosen the fix screw and remove the air inlet shutter together
with the evaporation heat exchanger, use a soft brush to clean it.
(2) Clear away the deposit in the chassis with water.
(3) After cleaning, install the air inlet shutter (together with the evaporative heat
exchanger), and tighten the fixing screw.
Attention: during cleaning, the pressure of the water should not be too high. When
cleaning the wet curtain, please don`t use acidic or alkaline detergents.
2. It is suggested that cooler be inspected and maintained annual to maximize the life
of the unit.

7
Ⅸ、Commons Faults and troubleshooting
Troubles Common Causes Solutions
Unable to start
the fan
Power failure Check power supply
Fuse burned Change the fuse
Poor contacted PCB Check the PCB
PCB damaged Change the PCB
No air flow
The motor starter’s capacitor
damaged Change the capacitor
The motor damaged Change the motor
There is jam at cooling pad or
air filter
Clean out the cooling pad and
air filter
PCB damaged Change the PCB
No cooling
Lack water in water tank Add water
Water pump damaged Change water pump
Water sensor damaged Change water sensor
Cooling pads are dirty Clean or replace pads
Tainted Water or cooling pads are dirty Change the water and clean
wet curtain
WARRANTY
Coolers are warranted by the manufacturer to the original user against defects in workmanship
or materials under use for one year after the date of purchase. Any part which is determined to
be defective in material or workmanship and returned to the supplier, shipping costs prepaid, will
be repaired or replaced at the supplier’s option.
This warranty is expressly in lieu of all other warranties, either expressed or implied. Any implied
warranty of merchantability or fitness for a particular purpose is hereby excluded. In no event or
circumstance shall the supplier be responsible for any incidental or consequential damages
whatsoever.
This manual suits for next models
3
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual