Bathroom Fan
Installation Instructions

Installation and Wiring Instructions for the Quiet Fan Conceal Range
IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Ambient temperatures higher than 40°C or less than –5°C.
• Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
2
A. All wiring to be in accordance with the current I.E.E. Regulations, or the
appropriate standards of your country and MUST be installed by a suitably
qualified person.
B. The Fan is suitable for installation within Zones 1 & 2.
C. The Fan should be provided with a local isolator switch capable of
disconnecting all poles, having a contact separation of at least 3 mm.
D. Ensure that the mains supply (Voltage, Frequency, and Phase) complies
with the rating label.
E. The Fan should only be used in conjunction with the appropriate products.
F. The Fan should only be used in conjunction with fixed wiring.
G. When the Fan is used to remove air from a room containing a fuelburning
appliance, ensure that the air replacement is adequate for both the fan and
the fuel-burning appliance.
H. The Fan should not be used where it is liable to be subject to direct water
spray for prolonged periods of time.
I. Where ducted Fans are used to handle moisture-laden air, a condensation
arranged to slope slightly downwards away from the Fan.
J. This appliance is not intended for use by persons (includingchildren) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
K. Children should be supervised to ensure that they do not play with
the appliance.
EN

ACCESSORIES (not supplied)
WALL FITTING KIT
A range of 100 mm wall kits are available for installing into most walls using liners supplied.
INSTALLATION
IMPORTANT: The fan should only be used in conjunction with fixed wiring.
PANEL/CEILING MOUNTING
1. For panel/ceiling mounting the fan should be installed into a closed duct protected by an exterior air grille that
must comply with the standard requirements of your country.
2. Cut a 105mm diameter hole for 100mm fans.
3. Push the two clips on each side of the fan and pull the grille away from the chassis.
4. Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position.
5. After installation, ensure impeller rotates freely and the shutters can open.
6. Replace the grille and ensure the clips reactivate.
WALL MOUNTING
1. For wall mounting either cut a 115mm diameter hole for 100mm fans, through the wall and insert the wall sleeve.
Slope the sleeve slightly downwards away from the fan. Cut to length and cement both ends into position flush
with the wall faces.
2. Push the two clips on each side of the fan and pull the grille away from the chassis.
3. Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position. Fix exterior
grille into position with the louvres positioned downwards. (Note: The grille must comply with the standard
requirements of your country. The wall kit used in this installation should provide a minimum ducting length of
100 mm from the fans back plate to the inside of the external grille).
4. After installation, ensure impeller rotates freely and the shutters can open.
5. Replace the grille and ensure the clips reactivate.
3
L. Stationary appliances not fitted with means for disconnection from the
supply mains having a contact separation in all poles that provide full
disconnection under over voltage category III, the instructions state that
means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
M. Ensure the grille is fully engaged onto the fan chassis using all clips.
N. Cleaning and user maintenance shall not be made by children.
EN

WIRING
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
IMPORTANT
• The fan should only be used in conjunction with fixed wiring.
• The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm2.
• Cable entry can be made from the rear or the side of the fan using the grommet provided.
• The extraction fan is suitable for connection to 220-240V ~ 50Hz supply.
• The fan is a class ll double insulated product and MUST NOT be earthed.
1. Select and follow the appropriate wiring diagram. (Fig. 1, 2 or 3)
2. Check all connections have been made correctly and ensure all terminal connections are securely fastened.
3. Ensure the impeller rotates and is free from obstructions.
SETUP
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
See Fig 1, 2, 3, 4, 5, & 6
–Single speed fan. Controlled by remote switch(e.g light switch or auto sensor) Fig.1.
*All timer versions require a third switch live wire for the timer to work.
4
QF100SX5CON – Single speed fan. Controlled by remote switch (e.g light switch or auto sensor) Fig.1.
QF100TX5CON – Single speed fan with overrun Timer* - The fan can be wired to a lighting circuit switch.
Fig.3. or wired for a basic on/o operation wire as Fig 2.
When switched ‘ON’, the fan will operate at full speed and will continue to run for a pre-set time after the
switch is turned ‘OFF’ Overrun timer adjustable 5-30min. See Fig.5.
QF100HTX5CON – Single speed fan with Humidity Timer* - The fan contains an integral humidity sensor.
In automatic mode the fan switches on when the room Relative Humidity (RH) increases. The fan will
continue to run until the room RH falls. These fans also include a built in overrun timer function that is
adjustable between 5-30 min. See Fig.6.
EN

SERVICING AND MAINTENANCE
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWERSUPPLY DURING MAINTENANCE.
1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build-up
of dirt or other deposits.
2. Wipe the inlets and front face with a damp cloth until clean.
The fan has sealed for life bearings, which donot require lubrication.
Fig.1:
QF100SX5CON
Fig.2:
QF100TX5CON & QF100HTX5CON (Timer / Humidistat disabled)
220-240V
~ 50Hz
3 AMP
MAX
220-240V
~ 50Hz
3 AMP
MAX
5
EN
This manual suits for next models
2
Table of contents
Languages:
Popular Fan manuals by other brands

Harbor Breeze
Harbor Breeze RLG52NWZ5L manual

Allen + Roth
Allen + Roth L1405 instruction manual

ViM
ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA
HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren
BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering
Triangle Engineering HEAT BUSTER SPL Series owner's manual