Aiphone LEF-3C User manual

83951800
0294(g)
O
AIPHONE
INSTRUCTIONS
The
LEF-C
System
is
a
semi-flush
mount
loudspeaker
communication
system,
which
can
accomodate
a
communication
network
of
up
to
11
stations.
By
adding
the
MY
PanTilt
video
system
and
the
BGR-10A
Music
&
Control
Center,
the
Master
Sentry
is
the
ideal
communication
system
for
residential
and
commercial
applications.
These
instructions
primarily
explain
the
LEF-C
audio
system,
with
some
references
to
integration
with
the
video
and
music
systems.
For
more
detailed
information
on
the
other
components
used
with
the
system,
see
the
instructions
for
those
products.
Master
Stations
LEF-5C
1
(?)
Speaker
(D
Sub
call-in
annunciator
LED
(also
illuminates
on
master
to
indicate
the
station
is
being
selected)
(D
Directory
card
&
button
identification
plate
(?)
Station
selector
button
(
5
)
Music
volume
control
(6)
Communication
volume
control
©Occupied
LED
(§)
All-call
button
&
mode
indicator
@
Door
Release
button
(not
included
on
LEF-3C)
(Jo)
Privacy
button
&
mode
indicator
©Talk
button
©OFF
button
|
off
I
©
Microphone
(©
Chassis

NAMES
AND
FUNCT\ONS(continued)
Master
Station
LEF-3C
®
Speaker
(D
Call
annunciator
LED
(D
Station
selector
button
(4)
Music
volume
control
©
Voice
volume
control
©
OFF
button
®
Privacy
button
&
mode
indicator
®
All-call
button
&
mode
indicator
©
TALK
button
Occupied
LED
(Q)
Microphone
Sub
master
station
LEF-1C
©
Speaker
©
Privacy
button
&
mode
indicator
CD
Music
volume
control
(4)
Door
release
button
©
Voice
volume
control
©
Occupied
LED
©
OFF
button
©
All-call
button
&
mode
indicator
®
TALK
button
©
Microphone
Indoor
sub
stations
LE-B,
LE-BN
©
Speaker
/
mic.
©
Music
volume
control
(LE-C,
CN
only)
(D
Privacy
button
&
mode
indicator
(LE-BN,
CN
only)
@
CALL
button
Weather-resistant
sub
stations
LE-D
(surface,
plastic)
j
|_E-DA
(flush,
stainless)
LE-DL
(surface,
anodized
aluminum)
©
Speaker/mic.
©
Directory
card
©
Illumination
lamp
(under
directory)
©
CALL
button

FEATURES
1.
A
wide
variety
of
system
configurations.
All-master,
Single-master
or
Intermixed
systems
can
be
created
2.
3-call,
5-call
&
10-call
masters
intermixable
3.
All-call
from
any
LEF-C
master
station
(when
system
includes
BGR-10A
or
BG-10C)
4.
Background
music
(BGR-10A
Music
&
Control
Center
or
BG-
IOC
All
call
amp.
is
required)
5.
PanTilt
video
can
be
incorporated
6
.
Overhead
camera
MYW-CA
can
be
included
(Locate
MY-CA
inside
the
enclosure
to
view
a
wider
area)
7.
LEF-1C
sub
master
adds
more
versatility,
having
All-call
and
door
answering
capabilities
SYSTEM
COMPONENTS
Basic
Audio
Communication;
*
Master
stations:
Max
11
stations
-
of
all
types
Select
a
suited
master
station
for
each
location
to
form
basic
audio
communication
network.
Listed
models
are
semi-flush
mount.
*
Models
Available:
LEF-3C:
3-call
LEF-5C:
5-call
LEF-10C:
10-call
LEF-1C:
1-call
sub
master
*
Sub
stations:
For
locations
requiring
only
calling
one
or
a
few
master
room
stations.
Privacy
button
and
Music
volume
control
are
optional.
Listed
models
are
semi-flush
mount.
LE-B:
Standard
LE-BN:
Privacy
LE-C:
Standard
w/music
volume
control
LE-CN:
Privacy
w/music
volume
control
*
Door
stations:
To
receive
calls
from
guests,
etc.,
To
be
located
at
front
door,
rear
door,
or
gate
for
entry
access.
Weather
resistant.
LE-D:
Surface,
plastic
cover
LE-DA:
Flush,
stainless
steel
cover
LE-DL:
Surface,
anodized
aluminum
cover
*
Power
supply:
To
supply
power
for
audio
communication
network,
select
either
power
supply
to
suit
the
system.
PS-12C:
DC
12V,
2A.
LEF
units,
UL/
CSA
Listed
or,
PS-12F:
DC
12V,
2.5A.
When
the
system
includes
the
BG-10C
Optional
functions;
Video
and
Music
Center
*
For
video
entrv
security
svstem:
May
To
incorporate
video
for
entry
security,
use
1-
or
3-camera
adaptor
to
connect
to
PanTilt
MY
video
systems.
MYW-P1L:
1-camera
adaptor
MYW-P3L:
3-camera
adaptor
MYH-CUB:
Semi-flush
video
monitor
MY-CA:
PanTilt
video
door
station,
surface,
plastic
cover
MY-DC:
Semi-flush
mount,
plastic
cover
MY-DG:
Semi-flush
mount,
metal
cover
PS-18C:
Power
supply
for
video
*
All
Call.
Door
Chime,
and
Music
fo
leceive
rddio,
have
the
All
Call
feature,
and
a
chime
from
the
door
station(s),
include
either
the
BGR-1OA
or
the
BG-10C
(with
related
power
supplies).
BGR-1
OA:
Music
Center
w/AIICall
&
Chime
PS-24C:
Power
supply
for
BGR-10A,
DC24V,
1A.
UL/CSA
Listed
BG-10C:
All
Call
&
Chime
Adaptor
PS-12F:
Power
supply
for
BG-10C
3

4
[
INSTALLATION
:•
M
-f.
T
..-
i
:.r
-L
r>
U
>
L
'*
.if
Y.
j
■
:
'
■
~
;r
.:•••
%
0
.%
r.
;|r
,iy
ti
tii
vy
i|.
%
it
r
;>
•
•
'
(1)
Mounting
guidelines;
•
Aiphone
Corporation
recommends
that
when
installing
any
of
its
communication
products,
the
wiring
must
be
run
at
a
distance
of
at
least
2
feet
(60cm)
from
any
AC
wiring,
fluorescent
lights,
or
dimmer
switches.
•
Aiphone
Corporation
is
not
responsible
for
improper
installations
of
its
products
which
result
in
interference
generated
by
AC
voltage,
dimmer
switches,
fluorescent
lighting
fixtures,
or
other
similar
electrical
devices.
If
noise
is
induced
into
the
intercom
system
from
one
of
these
sources,
it
must
be
corrected
at
the
source
by
the
installing
party.
LEF
Audio
Communication
System
Pre-Installation:
Wiring
0
Select
the
proper
type
of
wire
for
the
system
being
installed.
Use
the
maximum
number
of
conductors
for
the
system.
Consult
the
following
wiring
information
to
determine
how
many
conductors
will
be
required
for
your
system,
and
what
gauge
is
required.
(0
Shielded
wire
is
recommended,
but
not
required.
It
may
help
to
minimize
possible
interference
from
outside
sources.
Use
a
multi-conductor
cable
with
an
overall
shield,
not
twisted
pairs.
Run
the
cable
in
a
"daisy-
chained"
configuration,
in
and
out
of
each
station
in
the
system
from
beginning
to
end.
Sub
stations
may
be
homerun
to
the
nearest
master
station
in
the
system.
Door
stations
should
be
homerun
to
the
main
master
station
(where
the
BGR-10A
or
BG-10C
is
wired
into
the
system).
Note;
•
Some
intercom
stations
require
the
same
common
wires,
plus
individual
wires
for
each
station
on
the
same
I
wire
run.
Assure
that
the
cable
has
enough
conductors
for
every
station
included.
When
running
intercom
I
cable,
maintain
a
distance
of
at
least
24"
from
any
AC
wiring,
fluorescent
lighting,
and
dimmer
switches.
When
crossing
AC
wires,
do
so
at
a
90°
angle.
j
Avoid
running
intercom
cable
in
the
same
stud
space
with
electrical
wiring,
and
install
the
intercom
station
j
on
a
different
portion
of
the
wall
from
electrical
devices.
J
Installation
(T)
Lay
out
your
system
in
advance,
determining
which
stations
will
be
located
in
each
room,
and
what
their
respective
station
number
will
be.
Fill
in
this
information
on
your
wiring
diagram.
©
Cut
the
proper
sized
holes
in
the
wall
to
semi-flush
mount
the
intercom
stations
(C-version
units
only).
(3)
Separate
the
intercom
from
the
back
chassis
by
carefully
removing
the
control
panel
cover
and
directory
strip
and
loosening
the
screws.
Lift
up
on
the
intercom
portion
before
pulling
it
outward.
Unplug
the
connectors,
and
store
the
intercom
unit
in
the
box
until
the
wiring
is
completed.
0
Install
the
back
chassis
in
the
wall,,
and
make
wire
connections
as
shown
in
the
appropriate
wiring
diagram.
Be
sure
to
tighten
screws
securely
onto
the
wires.
(D
Reattach
the
intercom
unit
to
the
back
chassis
with
the
connectors,
and
place
it
on
the
back
chassis
from
the
top.
Tighten
the
screws,
and
replace
the
directory
strip
and
cover.
Remove
the
plastic
film
over
the
control
panel
cover.
(D
A
^er
all
connections
are
made
and
intercom
stations
installed,
test
the
operation
of
the
system.
Leave
these
instructions
with
the
end-user
for
their
reference.
Fully
train
the
end-user
as
to
the
functions
and
features
of
their
intercom
system.
Advise
the
end-user
on
which
rooms
are
assigned
to
each
station
number
so
they
can
fill
in
the
directory
card
on
each
station.
4

ounting
instructions
LEF-5C
or
LEF-10C
CUT-OUT
HOLE
DIMENSIONS
WOOD
SCREV
FRONT
CASE
OPERATION
PLATE
Be
sure
to
peel
off
clear
protection
film.
Cut
out
a
hole
in
the
wall;
H:
8-1/8"
xW:
5-3/4"(206
x
146mm),
securing
a
space
of
1/8“
(3mm)
on
the
left
and
right
sides.
LEF-3C
or
LEF-1C
WOOD
SCREW(4)
FRONT
CASE
I
OPERATION
PLATE
Be
sure
to
peel
off
clear
protection
film.
Cut
out
a
hole
in
the
wall;
H:
6-1/8"
xW:
3-3/4“
(155
x
96mm),
securing
a
space
of
1/8"
(3mm)
on
each
left
and
right
side.
CUT-OUT
HOLE
DIMENSIONS
LE-C
or
LE-CN,
LE-B
or
LE-BN
FRONT
CASE
WOOD
SCREW(4)
OPERATION
PLATE
Be
sure
to
peel
off
clear
protection
film.
Cut
out
a
hole
in
the
wall;
H:
6-1/8"
xW:
3-3/4"
(155
x
96mm),
securing
a
space
of
1/8"
(3mm)
on
each
left
and
right
side.
CUT-OUT
HOLE
DIMENSIONS
LE-D
LE-DA
SINGLE-GANG
BOX
STAINLESS
COVER
LE-DL
C*®"-t'llllliKte!
(3-5/16
)
2-GANG
BOX
MOUNTING
LE-DL
UNIT
BRACKET
SCREW(2)
SCREW(2)
SCREW(2)

(3)
Actual
terminal
locations;
LEF-5C,
LEF-10C
,,,
CN-3
v
t
*
i
*
*
*
*
j-
*
j\
_
LEF-3C
LEF-1C
PI
P2,
P3
Station
communication
channels
for
selective
calling
for
common
audio
communication
for
power
supply
for
receiving
a
call
and
music
for
occupied
LED
for
connection
of
external
music
speaker
(connected
to
S
-
E
terminals)
for
controlling
occupied
mode
when
called
for
door
release
(+12V
DC
when
door
release
button
is
pressed)
for
controlling
all
call
for
all
call
output
K10
for
selective
door
release,
controling
MY
camera,
or
control
of
remote
devices
(K#
becomes
negative
when
station
button
is
depressed)
1
~
10
PI
P2,
P3
Station
communication
channels
for
selective
calling
for
common
audio
communication
for
power
supply
for
receiving
a
call
and
music
for
occupied
LED
for
connection
of
external
music
speaker
(connected
to
S
-
E
terminals)
for
controlling
occupied
mode
when
called
for
door
release
(+12V
DC
when
door
release
button
is
pressed)
for
controlling
all
call
for
all
call
output
PI
P2,
P3
K
for
receiving
a
call
from
master
and
music
for
common
audio
communicaiton
for
door
station
communication
for
power
supply
for
occupied
LED
for
controlling
occupied
mode
when
called
for
door
release
(+12V
DC
when
door
release
button
is
pressed)
for
controlling
all
call
for
all
call
output
for
MY
video
door
station
control
LE-C,
LE-CN
LE-B,
LE-BN
LE-DA
Voice
communication
to
#
on
LEF-C)
Receiving
music,
All
Call,
and
door
chime
(w/BGR-lOA,
or
BG-10C)
External
speaker
output
]-
Commom
wires
to
LEF-C
network
Shorting
link
Shorting
link
1
Voice
communication(to
#
on
LEF-C)
E
Common
communication
-
Connect
to-terminal
LE-DL
to
supply
power
to
lamp
voice
communication
(to
#
LEF-C)
Common
communication

WIRING
DIAGRAMS
_
(1)
LEF-3C
audio
communication
system;
No.
SYSTEM
MASTER
DOOR(audio)
ROOM
SUB
1
All-Master
system
4
2
with
one
door
station
3
1
3
Intermixed
system
2
1
1
4
Single-Master
system
1
1
2
1
All-Master
system;
All-Master
system
w/one
door
station;
MASTER
©
LEF-3C
©
©
©
LEF-3C
LEF-3C
LEF-3C
MASTER
©
©
(3)
3
Intermixed
System;
MASTER
©
©
LEF-3C
LEF-3C
PS-12C
POWER
SUPPLY
4
Single-Master
System;
1
In
Intermixed
System.
In
sinole-master
svstem.
remove
the
shorting
link
on
the
Shorting
link
on
master
and
all
subs
master
stations
and
all
sub
stations.
MUST
REMAIN
ATTACHED.
LE-B,
BN
7

(2)
LEF-5C
audio
communication
system;
:
111!
NO.
SYSTEM
MASTER
DOOR(audio)
ROOM
SUB
1
All-Master
system
6
2
All-Masters
w/
door
station
5
1
3
Intermixed
system
3
1
2
4
Single-Master
system
1
1
2
All-Master
system
MASTER
®
©
<D
LEF-5C
LEF-5C
LEF-5C
2
All-Master
system
w/one
door
station
Music
&
Control
MASTERS
Center
CD
©
O)
@
©
BGR-10A
LEF-5C
LEF-5C
LEF-5C
LEF-5C
LEF-5C
Intermixed
system
MASTER
CD
©
®
LEF-5C
LEF-5C
LEF-5C
SUPPLY
4
Single-Master
system
POWER
SUPPLY
8
In
single-master
system:
{Home
run
wiring
only)
Shorting
link
(between
E
&
--
terminals)
on
the
master
and
ail
subs
MUST
REMAIN
ATTACHED.
For
daisv-chained
wiring:
Remove
jumpers
and
run
multi-conductor
cable
with
2
common
plus
1
individual
wire
per
station.
_
LE-B,
BN

^J
WIRING
DIAGRA
M
S
_
(3)
LEF-10C
audio
communication
system;
Jj
All-Master
system
with
one
door
station
All
call
&
chime
from
door
Music
&
chime
adaptor
POWER
SUPPLY
PS-12F
AC
TRANS.
PT-1210N
1
—
i
ry-pa
r
*
YELLOW(2)
BIACK(2)
Master
station
^g
P
tor
_
J
©
©
@
®
©
®
©
(§)
@
©
BG-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
LEF-10C
r
B
6
7
8
—
10
_
i
\
r
-
1
—
o
2
~
Q
-
i_
-
4
-
5
-V9-
B
-
7
8
9
10
6
C
-
t
R
-
-
n
Y
-
Pi
-
L
pO
_
1
c.
Do
-
Pd
1
-
J
\
L
Dual
Master
w/
sub-masters
BGR-10A
LEF-5C
LEF-5C
All
call
&
chime
from
door
LEF-1C
LEF-1C
LEF-1C

WIRING
DIAGRAM
(4)
1
PanTilt
video
door
station
(myw-pi
l
Adaptor)
(
Video
door
statiorT
)
MY-DC
A
1-r-
A1
B1
A2
-A2
B?
-'
IF
May
choose
any
PanTilt
Camera;
MY-DC,
MY-DG,
MY-CA,
or
MYW-CA
w/
MY-CA
Run
video
wires
in
a
separate
sheath
from
audio
communicaiton.
_
1
_
2
3
4
5
6
7
8
9
DC_
J0_
DB
:
11
DA
—---
MYH-CUB
©
MYH-CUB
©
Sub
master
J
LEF-1C
LEF-1C
EF-1C
LEF-1C
LEF-1C
LEF-1C
©
©
®
©
PT-121
ON
AC
trans
S
3
PanTlit
video
door
stations
(MYW-P3L
Adaptor)
(Video
door
station;
MYW-CA
w/
MY-CA
(BLUE)
(yellow)
Door
release
EL-9S
EL-9S
f
3-camera)
r
(.adaptor
)
MYW-P3L
Run
video
wires
in
a
separate
sheath
from
audio
communication.
A
1
M-
H
ai[;
HI
--
A
2
H
A
2
(:
B
-
C!
G
-
9
10
mi
ii
DA
\
MYH-CUB
©
MYH-CUB
LE-C,
CN
LE-C,
CN
LE-C,
CN
LE-C,
CN
LE-C,
CN
LE-C,
CN
®
®
©
©
®
<Q>
-"FT
1

(5)
Intermixed
System
-
Audio
and
PanTilt
Video
(6)
RY-AC
connection;
(7)
Music
speaker
connection;
To
activate
a
remote
doorbell
with
the
LEF-C
system,
use
the
RY-AC/A
relay.
To
receive
music
through
a
remote
music
speaker,
connect
2
wires
to
S
and
E
terminals
on
LEF-C
masters
and
LE-C,
LE-CN
LE-C,
LE-CN
ROOM
SUB
When
set
to
2
position,
music
is
not
heard
from
the
intercom
station,
but
all-call
announcement
can
be
received.
11
EES
0
L
-fl

Power
source:
Current
consumption:
Power
output:
Calling:
Communication:
Wiring:
Wiring
distance:
*
Switching
contact
capacity
for
door
release
*
Selector
switch
contact
capacity:
(K
Terminals)
*
Dimensions
&
weight:
DC
12V.
Use
PS-12C
power
supply
in
N.
America
(PS-12A
standard
everywhere
except
in
N.
America).
PS-12F
when
using
BG-10C.
Max.
300mA
per
station
Max.
800mW
at
20
ohm
(reception)
Max.
500mW
at
20
ohm
(transmission)
From
master
to
master
/
sub:
by
voice
or
electronic
mono
tone
From
LEF-1C
to
master:
by
all
call
announcement
Press-to-talk
at
calling
master.
Handsfree
communication
at
door,
sub
and
receiving
master.
Master
Stations:
Communication
only:
5
common
wires
plus
1
per
station
in
the
system,
looped.
Comm,
and
All
Call:
8
common
wires
plus
1
per
station
in
the
system,
looped.
Comm.,
All
Call,
Door
Release:
9
common
wires
plus
1
per
station
in
the
system,
looped.
Standard
Sub:
2
common
wires
plus
1
per
station
on
the
loop
LE-C/CN:
4
common
wires
plus
2
per
station
on
the
loop
Single
Master
System:
2
wires
per
sub,
homerun.
Between
two
farthest
master
stations
or
master
and
each
sub;
AWG
24AWG
22AWG
20AWG
18AWG
Distance
400'
650'
1000
1
1600'
Diameter
0.5mm
0.65mm
0
.8mm
1
.
0mm
Distance
120
m
200
m
300m
480m
AC
110V,
1
A.
DC
24V,
1A
(selective
door
release
or
control
of
external
devices),
on
output
of
RY-PA
relay.
DC
12V,
1A
LEF-3C.
LEF-1C:
210
x
155x35
(mm);
8-1/4"H
x6-1/8"W
x
1-3/8"D,
Approx.
470g
(1.04
lbs.)
LEF-5C.
LEF-10C:
240
x
200
x
35
(mm);
9-7/16"H
x
7-7/8"W
x
1-3/8"D
LEF-5C
Approx.
680g
(1.50
lbs.)
LE-10C
Approx.
750g
(1.65
lbs.)
WARRANTY
Aiphone
warrants
its
products
to
be
free
from
defects
of
material
and
workmanship
under
normal
use
and
service
for
a
period
of
one
year
after
delivery
to
the
ultimate
user
and
will
repair
free
of
change
or
replace
at
no
charge,
should
it
become
defective
upon
which
examination
shall
disclose
to
be
defective
and
under
warranty.
Aiphone
reserves
unto
itself
the
sole
right
to
make
the
final
decision
whether
there
is
a
defect
in
materials
and/or
workmanship;
and
whether
or
not
the
product
is
within
the
warranty.
This
warranty
shall
not
apply
to
any
Aiphone
product
which
has
been
subject
to
misuse,
neglect,
accident,
or
to
use
in
violation
of
instructions
furnished,
nor
extended
to
units
which
have
been
repaired
or
altered
outside
of
the
factory.
This
warranty
does
not
cover
batteries
or
damage
caused
by
batteries
used
in
connection
with
the
product.
This
warranty
covers
bench
repairs
only,
and
any
repairs
must
be
made
at
the
shop
or
place
designated
in
writing
by
Aiphone.
Aiphone
will
not
be
responsible
for
any
costs
incurred
involving
on
site
service
calls.
AIPHONE
CO.,
LTD.,
NAGOYA,
JAPAN
AIPHONE
CORPORATION,
BELLEVUE,
WA,
USA
©
C
OMMUNICATION
SYSTEMS
AIPHONE
HOME,
BUSINESS,
INDUSTRY
LEF-C-I
(E)
0294D
12
Printed
in
Japan(E)
Other manuals for LEF-3C
2
This manual suits for next models
2
Table of contents