INSTALLATION INSTRUCTIONS MODELS FRAS90/120
FRAK50/80/90/100/110/130
READ AND SAVE THESE INSTRUCTIONS.
IMPORTANT SAFEGUARDS.
CAUTION: To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do Not vent exhaust air into spaces
within walls or ceilings or into attics, crawl spaces, or garages.
WARNING: To reduce the risk of fire or electric shock, Do Not use this fan with any solid-state speed control device.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING.
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
CAUTION: For general ventilating use ONLY. DO NOT use to exhaust hazardous or explosive materials and vapors.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.
a) Installation work and electrical wiring must be done by a qualified person (s) in accordance with all applicable codes and
standards, including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published
by the National Fire Protection Association (NFPA) and the American Society of Heating, Refrigeration, and Air-Conditioning
Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) NEVER place a switch where it can be reached from a tub or shower.
IF YOU DISCOVER ANY MISSING COMPONENTS OR DAMAGE CALL 1-800-465-7300 BETWEEN 8:00 AM &
3:30 PM EASTERN TIME MONDAY TO FRIDAY.
________________________________________________________________________
________________________________________________________________________
FIGURE 2.
210572084
9-3/8"
10-7/16"
8-1/8"
11-5/16"
9-1/2"
1"
12-15/16"
10-5/16"
11/16"
SUB FLOOR 3/8" FIRE RATED GYP BOARD
MINIMUM 18"x JOIST SPACE
REQUIREMENTS FOR INSTALLATION IN UL/ULC RATED CEILING ASSEMBLIES
SEE UL AND ULC FIRE RESISTANCE DIRECTORY
FINISHED
CEILING
GRILL
MOUNTING
SCREW
METAL
GRILL
CEILING
RADIATION
DAMPER
DAMPER
MOUNTING
SCREW
DAMPER
MOUNTING
FRAME
FAN HOUSING 5/8" F.R. GYP BOARD TO COVER TOP OF FAN
FAN HOUSING
MOUNTING RAIL
FAN HOUSING
MOUNTING SCREW
AND WASHER
MIN. LENGTH 1.5"
This fan must be installed as per UL and CUL rated ceiling assembly
(refer to fig. 2). This will require the installation of minimum 5/8" fire
rated gypsum board under the subfloor and a piece of the same
gypsum board to cover the top of the fan housing.
To install this fan you should not have to remove the fan's blower
assembly. You gain access to the wiring compartment via the
triangular wire cover on the outside of the fan housing. If for some
reason you wish to remove the fan's blower it is secured in place with
one screw through the venturi, once removed you can release the
blower from the lances in the housing and lift the blower out. Place it
some where so it does not get damaged.
MOUNTING THE HOUSING. REFER TO FIG. 2.
AS SHOWN BELOW THE CEILING DAMPER FRAME WILL REQUIRE A
CUTOUT OF 11-5/16" x 9-1/2" IF AFTER THE INSTALLATION IS
COMPLETE ANY GAP IS PRESENT BETWEEN THE DAMPER FRAME
AND CEILING DRY WALL SEAL WITH CAULK CARRYING THE
APPROPRIATE UL RATING.
Select the best location to mount the housing in the ceiling. As per UL
and CUL fire resistance construction you will require a minimum of
18" joist space.
1. Determine the best location to mount the fan.
2. Select the most convenient electrical knockout and remove it,
remove the triangular wire cover.
3. Insert the 4 slide rails into the channels on the housing side.
4. Adjust the housing height so the housing will be flush with the
finished ceiling.
5. Secure the 4 slide rails to the joist using wood screws. Make sure
you install a washer at the head of each screw as shown in the
diagram below This will ensure the screw head does not slip out of
mounting rail.
6. Once the 4 slide rails have been secured in place you will have to
install the 2 rail supports on both sides of the housing. They hook onto
the bottom of rail channels and are secured at the top via two screws.
DUCTING.
Note: All ducting must comply with local and national building codes.
1. Ensure any tape holding the damper in place is removed and that
the damper is operating freely.
2. Connect the ducting to the fan's duct collar. Secure in place using
duct tape or a screw clamp. Always duct the fan to the outside
through a wall or roof cap.
ELECTRICAL WIRING.
CAUTION: Make sure the power is switch off before beginning this
installation.
FIG. 1.
Note: All wiring must comply with local and national codes. You
MUST ground this fan.
1. Run wiring from an approved wall switch carrying the appropriate
rating. One neutral (White), one ground (Green or Bare Copper), and
one hot (Black lead connected to the switch). Secure the electrical
wires to the housing using an approved electrical connector. Make sure
you leave enough wiring in the box to make connection to fan's wiring.
2. Connect the white wire to the white wire on the fan's receptacle.
Connect the black wire to the black wire on the fan's receptacle.
Connect the ground from the house to the fan's ground.
3. Retrieve the fan's triangular wire cover and secure in place with the
#6 screw removed earlier.
4. From below spin the fan's blower wheel to ensure it moves freely.
COMPLETING THE INSTALLATION.
Once the fan housing has been installed and the ceiling drywall is in
place you can complete the fan’s installation
CEILING DAMPER & GRILL INSTALLATION.
CAUTION: The ceiling damper supplied is spring loaded and has the
potential to release suddenly when handled improperly. A damage
spring or defective fusible link can allow the damper to close violently
into the handler's hand or arm, causing serious injury. Care should be
exercised when handling and installing spring loaded dampers. It is
recommended that gloves be worn by handlers and installers.
The ceiling damper supplied with the unit is designed to install only in
Air-King Model AKFH2 housings.
1. Install the ceiling damper & ceiling damper frame into the opening
of the fan housing. The ceiling damper frame is designed to fit on the
outside of the housing and the ceiling damper will sit on the inside of
the fan housing.
2. Once positioned in place secure the ceiling damper frame to the fan
housing using two of the supplied #8 x 1" screws. Carefully drive the
screws through the two oblong slots on the ceiling damper frame into
the screw retaining lances on each side of the fan housing. Complete
this step slowly as you do not want to damage the lances on the housing.
3. Once the ceiling damper is installed and secure, position the metal
fan grill in place aligning the two holes in the grill with the two
extruded holes on the ceiling damper frame. Use the remaining two
#8 x 1" screws to secure the grill onto the fan.
CARE AND MAINTENANCE
CAUTION - BEFORE CLEANING OR SERVICING TURN OFF THE POWER
TO THE FAN.
1. Clean the grill using a mild soap or detergent only, no abrasives.
2. The fan motor is permanently lubricated, DO NOT oil the motor.
3. Once a year it is a good idea to inspect and clean the internal parts of
the fan, over time debris will build up on the fan blade causing the motor
to work harder than it should. When cleaning the internal parts be
extremely careful working around the spring loaded ceiling damper. Wear
gloves and use a vacuum with an extension hose to clean inside the fan.
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase or until the
original purchaser of the product sells or transfers the product, whichever first occurs.
WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the
same or comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage,
abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay
return shipping charges from Air King following warranty repairs or replacement
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE
OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL
AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II)
REPLACEMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING’S
LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION
OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or
limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province. Proof of purchase is
required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 465-7300
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm
Eastern. Please have your model number available, as well as the type and style (located on the label inside of your product).Please do not return product to place of purchase.
www.airkinglimited.com
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST
HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

This manual suits for next models

7

Other Air King Fan manuals

Air King FRAK50S User manual

Air King

Air King FRAK50S User manual

Air King 9119 Service manual

Air King

Air King 9119 Service manual

Air King AKLC70RCB User manual

Air King

Air King AKLC70RCB User manual

Air King AK100D User manual

Air King

Air King AK100D User manual

Air King AK300LS User manual

Air King

Air King AK300LS User manual

Air King AK55L User manual

Air King

Air King AK55L User manual

Air King 4 CH69B/9525B User manual

Air King

Air King 4 CH69B/9525B User manual

Air King AKF100D4 User manual

Air King

Air King AKF100D4 User manual

Air King FAS Owner's manual

Air King

Air King FAS Owner's manual

Air King 6C507B/9145B Instructions for use

Air King

Air King 6C507B/9145B Instructions for use

Air King AKLS Series User manual

Air King

Air King AKLS Series User manual

Air King 3C614F Instructions for use

Air King

Air King 3C614F Instructions for use

Air King 2EJR6G Service manual

Air King

Air King 2EJR6G Service manual

Air King MFAS Owner's manual

Air King

Air King MFAS Owner's manual

Air King D4D User manual

Air King

Air King D4D User manual

Air King EXHAUST FANS AS50 User manual

Air King

Air King EXHAUST FANS AS50 User manual

Air King AK964 User manual

Air King

Air King AK964 User manual

Air King AK905 User manual

Air King

Air King AK905 User manual

Air King DRLC702 User manual

Air King

Air King DRLC702 User manual

Air King 9120H User manual

Air King

Air King 9120H User manual

Air King FRAK90 User manual

Air King

Air King FRAK90 User manual

Air King AK130 User manual

Air King

Air King AK130 User manual

Air King Exhaust Fan ASF90 User manual

Air King

Air King Exhaust Fan ASF90 User manual

Air King AKA130 Owner's manual

Air King

Air King AKA130 Owner's manual

Popular Fan manuals by other brands

Panasonic UG25A operating instructions

Panasonic

Panasonic UG25A operating instructions

FläktGroup Roofmaster STEC Series Installation and Maintenance

FläktGroup

FläktGroup Roofmaster STEC Series Installation and Maintenance

Hunter 23943 Parts guide

Hunter

Hunter 23943 Parts guide

S&P PCLP80XP quick start guide

S&P

S&P PCLP80XP quick start guide

SonicAire MOBILE Series owner's manual

SonicAire

SonicAire MOBILE Series owner's manual

EVOAQ EX-AX150MC installation manual

EVOAQ

EVOAQ EX-AX150MC installation manual

MONTAIR UCM Series Instructions for installation, use and maintenance manual

MONTAIR

MONTAIR UCM Series Instructions for installation, use and maintenance manual

TJERNLUND HS-3 manual

TJERNLUND

TJERNLUND HS-3 manual

COMPANION COMP356 instruction manual

COMPANION

COMPANION COMP356 instruction manual

Impecca FANFAIR FTF-3000 user guide

Impecca

Impecca FANFAIR FTF-3000 user guide

Pullman Holt F500 Specifications

Pullman Holt

Pullman Holt F500 Specifications

Hunter 21620 Installating and operation manual

Hunter

Hunter 21620 Installating and operation manual

HELLER HWF40P instruction manual

HELLER

HELLER HWF40P instruction manual

Hunter 27048 Parts guide

Hunter

Hunter 27048 Parts guide

Geovent W3 Filter Unit instruction manual

Geovent

Geovent W3 Filter Unit instruction manual

Samsung ERV operating instructions

Samsung

Samsung ERV operating instructions

Bosch LR 7CBS2 Series User manual and assembly instructions

Bosch

Bosch LR 7CBS2 Series User manual and assembly instructions

Hurricane CLASSIC 16" OSCILLATING WALL MOUNT FAN Instructions for use

Hurricane

Hurricane CLASSIC 16" OSCILLATING WALL MOUNT FAN Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.