Alecto COA4010 User manual

NL - GEBRUIKSAANWIJZING
FR - MODE D’EMPLOI
D - ANLEITUNG
EN - MANUAL
COA4010

2
CONTENT
Nederlands ......................................................................................................................3
Français.........................................................................................................................13
Deutsch .........................................................................................................................23
English...........................................................................................................................33
Geel - Fault
Jaune - Erreur
Gelb - Störung
Yellow - Fault
Groen - Stroom
Vert - Alimentation
Grün - Leistung
Green - Power
Rood - Alarm
Rouge - Alarme
Rot - Alarm
Red - Alarm
Test / Menu knop
Bouton de test / menu
Test / menu -Taste
Test / menu button

33
The COA4010 is a CO detector, developed especially to detect carbon monoxide in your living area.
GENERAL:
What is carbon monoxide?
Carbon monoxide, designated CO, is also called carbon monoxide. It is a colorless, tasteless, odorless and
poisonous gas. ATTENTION this is CO (carbon monoxide) and not CO2 (carbon dioxide).
YOU CANNOT SEE, SMELL OR TASTE CARBON MONOXIDE AND IT CAN BE FATAL.
CO is emitted as part of a hot gas mix and therefore it tends to rise until it cools down. This is in contrast to
CO2, which is heavier than air and drops.
All fuel types can produce carbon monoxide.
Most common CO sources:
The most common carbon monoxide sources are (faulty) gas devices used for:
• Heating (Central heating boiler, Geyser, gas heater, portable fuel stoves)
• Cooking
• Vehicles running in an adjacent garage
• Cloggedchimneys,smokeductsorreplaces
• Fuel-powered tools
• Theuseofopenreinanenclosedspace
The COA4010 does not detect any gases other than CO gas.
Symptoms of carbon monoxide poisoning:
Symptoms of carbon monoxide poisoning are dizziness, fatigue, weakness, headaches, nausea, vomiting,
sleepiness and confusion.
Everybody is sensitive to the dangers of carbon monoxide, experts agree however that small children,
pregnant women and their unborn babies, elderly people and persons with heart or breathing problems
have the highest risk of serious or even fatal injuries. Every year an authorized installer must inspect and
clean your heating system, vents, chimney and smoke ducts.
IMPORTANT:
•ThisCOdetectorisnotareplacementforsmoke,reorotherdetectors.
• The detector must be installed by a competent person.
• This detector cannot protect people with special medical conditions
• This detector might not prevent any chronic health effects of carbon monoxide on the body.
• This CO detector is not a replacement for the correct installation, use and periodic
maintenance of combustion equipment, nor adequate ventilation of spaces in which these
devices are being used.
• We recommend you to weekly test the CO detector using the “TEST/MENU” button on the
CO detector.
USER MANUAL
EN

34
• This CO detector only sounds the alarm when carbon monoxide is present at its sensor. Therefore, it’s
possible for carbon monoxide to be present elsewhere and the alarm doesn’t sound.
• When the alarm sounds, possible harmful carbon monoxide levels are present!
Carbon monoxide can be deadly!
ALARM
When the CO detector sounds the alarm, carbon monoxide (CO) might be present
which can be fatal. Therefore, never ignore this alarm.
When alarmed, the red ALARM LED will blink rapidly and emit 4 short audible beeps. The alarm cycle
will repeat 5 times every 10 seconds. Once the carbon monoxide concentration falls below 40PPM the
alarm will stop.
What to do when the alarm sounds:
1. Open doors and windows and immediately do outside into the fresh air. Check whether
everybody has left the building.
2. Callanofcialinstallertoinspectthecorrectfunctioningandstateofmaintenanceofthe
combustion source (gas or oil powered equipment) that could be the cause for the CO alarm.
3. Only enter the building again after the cause has been resolved and the building has been
well ventilated.
The alarm sound can be turned off for up to 10 minutes (Hush function) by pressing and holding the TEST
key for 2 seconds (<300PPM).
The time the hush function is active depends on the measured CO concentration. Above 300PPM the hush
function is not possible.
When the CO concentration drops, the alarm will eventually stop automatically. During the hush function,
press the test button can not immediately disable the hush function and make the alarm audible and need
to wait for 10 minutes. Recommended locations for the installation of the COA4010:
CO-
concentration Period of inhaling and symptoms
50PPM The maximum concentration a healthy adult can withstand in 8 hours.
200PPM After 2-3 hours, mild headache, sensations of weakness, dizziness, nausea.
400PPM Within 1-2 hours, ache in forehead; after 3 hours, life-threatening.
800PPM Within 45 mins, dizziness, nausea, convulsions; Loss of consciousness within 2 hours; Fatal
within 2-3 hours.
1600PPM Within 20 mins, headache, dizziness, nausea; Fatal within 1 hour.
3200PPM Within 5-10 mins, headache, dizziness, nausea; Fatal within 25-30 mins.
6400PPM Within 1-2 min, headache, dizziness, nausea; Fatal within 10-15 mins.
12800PPM Fatal within 1-3 min.

35
GENERAL
• Install the CO detector in a location where the alarm can be heard inside bedrooms.
• Inhouseswithmultipleoors,it’srecommendedtoinstallaCOdetectoroneachoor.
• Install the detector on a spot where the weekly check can be performed easily.
• We recommend that a CO detector be hung in every room with a combustion appliance at the air outlet
of the appliance.
USER MANUAL
CO MELDERS
Smoke detectors, Fire extinguishers
and Fire blankets
RECOMMENDED
DON’T USE
ALSO AVAILABLE

36
In spaces without combustion devices
• Install the CO detector in spaces without combustion devices, preferably at breathing
height.
• Install the CO detector way from of roof ridges, corners. arched ceilings or front roofs.
• Install the CO detector 60 centimeters from surrounding walls and ceilings.
>150 cm
Niet in
deze ruimte
Not in this
area
Not in this
area
Near this
area
90 cm
minimum
90 cm
minimum
60 cm
minimum

37
In spaces with combustion devices
• InstalltheCOdetectorat1to3metersawayfromcombustiondevices,withintheairow
from the combustion device.
• Install the CO detector way from of roof ridges, corners. arched ceilings or front roofs.
• In the case of smaller spaces (<4m³), the detector should be installed outside these spaces.
• Install the CO detector 60 centimeters from surrounding walls and ceilings.
Installation on both walls and ceiling is possible in rooms with a combustion device.
>60 cm
USER MANUAL

38
In bedrooms
• Install the CO alarm in bedrooms at breathing height while sleeping.
• Install the CO detector way from of roof ridges, corners. arched ceilings or front roofs.
Breathing
height

39
AVOID THE FOLLOWING PLACES FOR INSTALLATION:
• Do not install the CO-detector in the turbulent air created by ceiling fans.
• Do not install the CO-detector near vents with fresh air.
• Do not install the CO-detector near doors and windows leading outdoors.
• Do not install the CO-detector near extremely dusty, dirty or greasy spaces such as heating spaces
<4m³ or pantries. Dust, grease and household chemicals can affect the sensor.
• Install the CO detector at least 0.5 meters away from gas discharge lamps (halogen) because of
electronic interferences that can lead to false alarms.
• Do not install the CO detector in humid and wet spaces, such as the bathroom.
• Do not install the CO detector in a location where the temperature is lower than -10°C or warmer than +40°C.
• Do not install the CO detector in a place where the humidity is higher than 93%RH.
• Never install the CO detector behind curtains or furniture. Carbon monoxide must be able to reach the
sensor to ensure the sensor can properly detect carbon monoxide levels.
• NeverinstalltheCOdetectoratonatableorsimilarsurface.
• Never install the CO detector in spaces where spray cans may be used (hair spray, deodorant)
INSTALLATION:
1. Install the mounting plate on a suitable spot, using the mounted plugs and screws.
2. PlacetheCOA4010onthemountingplate.Makesurethatthepinonthebacksideinttedinthe
mounting base. Slide the COA4010 downwards to lock into position on the mounting plate.
3. Youcanperformthersttestbybrieypressingthetestbutton,seealsoparagraph“Testing”.
4. The CO detector is now functional.
USER MANUAL
Not behind a
cabinet
Not behind a
curtain
Not next to a
ventilation

40
USE:
1. Every50seconds,thepowerLEDlightsbrieytoindicatethatthedetectorisoperating.
2. Whenthedetectorgivesashortbleepevery50secondsandtheyellow“Fault”LEDashes,the
batteries should be replaced as soon as possible. At the start of these warnings, the detector will
operate for 30 days standby or 4 minutes in alarm mode.
3. The table below shows when the detector will sound the alarm.
4. When the alarm sounds, it will turn off after moving the detector to a space with a CO concentration
below 40PPM.
5. The alarm sound can be turned off for up to 10 minutes by pressing and holding the TEST button for 2
seconds (<300PPM).
6. The detector will automatically perform a fault inspection every 180 seconds.
TESTING:
When the CO detector is operating under normal conditions, the sensor and siren should be tested at least
every month. Press the “TEST/MENU” key. “POWER”, “FAULT” and “ALARM” LED light up. Then the
detector gives 4 beeps within 2 seconds and also the red “ALARM” LED lights up. Everything is now ok.
If the detector gives an error message, the yellow “FAULT” LED will light 2 times and give 2 beeps per
45 seconds.
SILENCING ALARM (HUSH FUNCTION):
Sometimesthealarmmaygooffduetoinuenceofenvironmentalfactors.Forexample,smokecontaining
certain concentrations of carbon monoxide or other chemical gases. When the CO level is lower than
300PPM, you can press the “TEST” button. The alarm will stop and the detector will immediately check the
CO value again. When the concentration is higher than 300PPM it is impossible to stop the alarm.
The red and green LED will blink 2 times per second- and the sound signal will stop for max 10 minutes.
If after max 10 minutes the concentration is still above 200PPM the alarm will be activated again. During
the hush function, press the test button can not immediately disable the hush function and make the alarm
audible and need to wait for 10 minutes.
LED INDICATION:
Red LED.................................................. Alarm, carbon monoxide present
Yellow LED.............................................. Sensor problem
Green LED.............................................. Normalfunctioning,theLEDashesevery50seconds
CO concentration NO ALARM for ALARM for
30 PPM 120 min. -
50 PPM 60 min. 90 min.
100 PPM 10 min. 40 min.
300 PPM - 3 min.
In accordance to the EN50291 standard.

41
BATTERY INFORMATION INDICATION:
• Every 120 seconds the battery is automatically checked.
• Every50secondsthegreenLEDwilllightupbrieyaslongasthetotalbatteryvoltageissufcient.This
means that the battery capacity is okay. If the battery voltage is to low, the yellow “Fault” 1x LED will
brieylightuponceevery50secondsandaone-timebeepwillsound.
It will take approximately 120 months before these are empty.
SCREEN MESSAGES :
REASON FOR SENSOR FAULT:
Faults can be caused by broken circuitry, a faulty sensor or faulty electronic parts.
SENSOR FAULT CAUSED BY CHEMICAL GASES:
When volatile chemical gases such as alcohol are the cause for error detection, this may be corrected by
switching the detector off and leave it in fresh air for 24 hours. This will restore the sensor. If the error
is not cleared after these 24 hours, the detector is faulty and should be replaced. Don’t repair the
detector yourself, but have it repaired by the importer.
When the alarm is contaminated and damaged by high concentrations of chemical gases, the sensor could
be affected. This will lead to a temporary error or permanent damage. When the alarm sounds and you
can smell a chemical gas, this could be the reason. Carbon monoxide is a colourless and odourless gas.
Chemical gases do have an odour.
The following substances and gases can cause false alarms or permanently damage the detector:
Methane, propane, iso-butane, ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, acid, ether,
hydrogen, hepatic gas, sulphur dioxide, aerosol, propellant, alcohol preparation, paint, thinner, dissolvent,
bonding agents, shampoo, aftershave balm, perfume, car exhaust (cold start) and certain cleaning agents.
MAINTENACE:
• To keep your CO detector in proper working order, please follow these easy steps:
• Once a month, check that the alarm is working properly by pressing the test button.
• Clean the CO detector with a vacuum cleaner or with a soft cloth or brush once every month to remove excess dust.
Standard screen
Internal test screen
Error message
End of sensor life
(Replace product)
Low battery warningCO concentration
>20PPM
Max measured value
CO > 999PPM
USER MANUAL

42
• Check whether the batteries are damaged, exhausted or corroded.
• Explain to children that they should not play with the CO detector.
• Ensure children are aware of the dangers of carbon monoxide poisoning.
• Never use cleaning agents or other solutions to clean the CO detector.
• Never use air fresheners, hair spray or other aerosols near the CO detector.
• Don’t paint the CO detector. Paint covers the vents preventing the sensor from detecting CO.
• Never disassemble, repair or modify the product yourself; there’s a high risk that it will no longer
function correctly or reliably.
BATTERY REPLACEMENT
The Battery has a lifetime of 10 years. After 10 years you need to replace the complete product, the battery
itself is not exchangeable.
SENSOR REPLACEMENT:
The sensor has a lifetime of 10 years. After 10 years you need to replace the complete product, the sensor
itself is not exchangeable.
• If the yellow “FAULT” LED lights up 3x and 3 beeps per 45 seconds are heard, the entire product should
be replaced. The reliability of the sensor cannot be guaranteed after this date.
SPECIFICATIONS:
Power supply:...............................................1x 3V CR17450 Lithium battery
Sensitivity and time:.....................................30ppm, alarm is not activated within 120 minutes
......................................................................50ppm, alarm is activated within 60~90 minutes
......................................................................100ppm, alarm is activated within 10~40 minutes
......................................................................300ppm, alarm is activated within 3 minutes
standby consumption:..................................<6.79uAAverage
consumption at alarm:..................................<37.9mA Average
Sound pressure at alarm: ............................>85dB (3m distance)
Environmental conditions during use:..........-10~+40°C, 30~93% humidity.
Type:.............................................................Type B (unchecked output)
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical depot. Product
may not be thrown out as normal waste, but must be recycled as electrical waste.
DECLARATION OF PERFORMANCE
The declaration of performance is available on the website
http://DOC.hesdo.com/COA4010-DOC.pdf
Other manuals for COA4010
1
Table of contents
Other Alecto Carbon Monoxide Alarm manuals