AlienTek DP100 User manual

User Manual
High Performance Digital Power
DP100 Digital Power User Manual
Revision history
Version
Date
Modify
V1.0
2022/06/11
First release
V1.1
2022/07/10
Modify some details,Summary of common problems, etc
V1.2
2023/08/01
Add instructions for reverse protection and startup output settings
User
Manual

High Performance Digital Power
User Manual www.alientek.com
1
DP100 Digital Power User Manual
Contents
Safety Instructions .........................................................................................................1
1,Product Introduction ................................................................................................1
2,Technical Parameter.................................................................................................2
3,Packing list...............................................................................................................3
4,Quick Start ...............................................................................................................3
4.1 Appearance description .......................................................................................................3
4.2 Main Interface.....................................................................................................................4
4.2.1 Main interface...................................................................................................4
4.2.2 Operation instructions....................................................................................5
4.3 Preset Interface....................................................................................................................6
4.3.1 Preset interface...............................................................................................6
4.3.2 Operation instructions...................................................................................7
4.4 Menu Interface ....................................................................................................................8
4.4.1 Menu interface...................................................................................................8
4.4.2 Operation instructions...................................................................................9
5,ATK-DP100 Instructions .......................................................................................10
5.1 Basic function interface.........................................................................................10
5.1.1 Basic function.................................................................................................10
5.2 Advanced function interface...................................................................................11
5.2.1 Advanced function...........................................................................................11
5.3 Firmware upgrade interface.....................................................................................12
5.3.1 Firmware upgrade..............................................................................................12
5.3.2 Instructions......................................................................................................13
5.4 Software update interface.......................................................................................13
5.4.1 Software update...............................................................................................13
6,FAQ........................................................................................................................15
7,Serivices.................................................................................................................16

High Performance Digital Power
User Manual www.alientek.com
1
DP100 Digital Power User Manual
Thank you for purchasing this product. We recommend that you spend some time
reading this user manual in order that you fully understand all the operational features
it offers.
Safety Instructions
1,The Type-C power supply range of DP100 is DC4.8V~36V. It will enter under voltage lockout
status and disable output when below 4.8V, and may be damaged when exceeds 36V ! It is
recommended to use 5V~32V power supply.
2,Ensure the input voltage is higher than output voltage, because DP100 working in Buck mode.
3,DC-TypeC cable is needed when use DC adapter for DP100. It is strongly recommended to
connect DC-TypeC cable to the DP100 first, then connect the DC adapter to DC-TypeC cable,
which can protect the Type-C interface and extend the service life of the interface.
4,When supplies power to inductive and capacitive loads, it is recommended to connect the load
first, and then turn on the DP100 output!
5,When the output is greater than 20V, please do not perform short-circuit test repeatedly,
otherwise the device may be damaged!
6,The negative terminal of the USB-A interface is GND, but the 4.0 banana plug output
negative terminal is not GND, so do not use it short-together.
7,When the output at high power mode, there will be a certain degree of heat, which is a normal
phenomenon. It is recommended to use it in a well-ventilated environment.
8,The Type-C power supply interface supports PD/QC protocol, and the default power supply
voltage is the highest voltage that the fast charger can supports.
9,Some PD fast charging heads have stricter requirements. If the input capacitor of DP100 is not
empty, it will causes a failure of protocol detection. In this case, unplug the power supply and
wait 3~5 min until the input capacitor of DP100 is fully discharged, then connecting it again.
10,When DP100 is used to charge batteries, it is strongly recommended to add an anti-backflow
module(eg. Schottky diode) at the output end to protect the device from damage!
1,Product Introduction
DP100 is a high-performance digitally controlled DC step-down regulated power supply,The
product mainly has the following characteristics:
⚫Type-C supports DC5~32V power supply, supports PD/QC charger and power bank
⚫Support output voltage 0~30.00V, resolution 0.01V, accuracy 0.1%
⚫Support output current 0~5.000A, resolution 0.001A, accuracy 0.1%
⚫High conversion efficiency up to 97% at 100W(30V, 3.334A) , low calorific value
⚫Low ripple output, full load ripple <10mVp-p, smooth power-on curve, no overshoot
⚫10 groups of preset outputs, which can be called out directly, convenient and quick
⚫Hardware constant voltage and constant current circuit, intelligent anti-burning

High Performance Digital Power
User Manual www.alientek.com
2
DP100 Digital Power User Manual
⚫Various complete protection circuit, safer to use
⚫Support multiple ( ≤3) devices in series to achieve higher voltage output or
positive-negative voltage output
⚫USB-A interface host mode (USBH) supports output 5V/1A, supports wired/wireless
mouse driver
⚫USB-A interface slave mode (USBD) supports communication with the PC and supports
firmware upgrade
⚫Rich display, using 0.96-inch 160*80 high-definition IPS screen, the display content is
more delicate
⚫Customized mold, humanized angle design of display and control panel, convenient for
users to operate and observe. Small size, easy to carry
2,Technical Parameter
Items
Description
Input parametres
Input voltage range:DC5.0~32V,100mA~5A
Supports PD/QC charger and power bank
Output parametres
4.0mm banana plug interface: 0~30V,0~5A,100W(Max)
USB-A interface (USBH): 5V/1A(Input>5.5V/1A)
Setting resolution
Output voltage: 10mV
Output current: 1mA
Setting accuracy
Output voltage: ≤0.1% ±5mV
Output current: ≤0.1% ±3mA
Readback resolution
Input voltage: 0.01V
Output voltage: 0.01V
Output current: 0.001A
Readback accuracy
Input voltage: ≤ 0.2% ±10mV
Output voltage: ≤ 0.1% ± 10mV
Output current: ≤ 0.1% ± 5mA
Load regulation
Voltage: ≤ 0.05% ±5mV
Current: ≤ 0.1% ± 3mA
Power regulation
Voltage: ≤ 0.05% ±5mV
Current: ≤ 0.1% ± 3mA
Ripple and Noise
Output voltage: ≤ 2mVrms, 10mVp-p
Output current: ≤ 1mArms, 3mAp-p
Temperature coefficient
of output
Output voltage: ≤ 200ppm
Output current: ≤ 200ppm
Full load efficiency
≤97% @100W(30V, 3.334A)
Working environment
0℃~40℃,0~75%RH
Size and weight
100.4mm*62.2mm*17.2mm / 95g
Table1.1 Characteristic

High Performance Digital Power
User Manual www.alientek.com
3
DP100 Digital Power User Manual
3,Packing list
⚫DP100 host 1pcs
⚫A-A USB cable 1pcs
⚫DC-TypeC cable 1pcs
⚫Alligator clip power cord(Black) 1pcs
⚫Alligator clip power cord(Red) 1pcs
⚫Simple paper manual 1pcs
⚫zipper bag 1pcs
⚫32V 3A Power Adapter (Optional)
⚫GaN Charger 65W (Optional)
⚫C2C cable 100W (Optional)
4,Quick Start
4.1 Appearance description
Figure 4.1.1 DP100 Appearance
Description
①4.0mm banana plug interface Negative ②4.0mm banana plug interface Positive
③0.96-inch high-definition IPS screen ④Left button
⑤Middle button■⑥ Right button
⑦Adjustment wheel ⑧ USB-A interface
⑨ Type-C power supply interface
③
④
⑤
⑥
⑦
②
①
⑨
⑧

High Performance Digital Power
User Manual www.alientek.com
4
DP100 Digital Power User Manual
4.2 Main Interface
4.2.1 Main interface
The main interface is used to display the main parameters, including: input voltage, output
voltage setting, output constant current setting, real-time voltage output, current output, power
output, output mode, working status, lock status, USB-A mode, preset group information and
device temperature.
The information of the main interface is shown in Figure 4.2.1:
Figure 4.2.1 Main interface
①Read back voltage of input, which is power supply voltage, the unit is V.
②Output voltage setting, 00.00~30.00V, resolution 0.01V, unit V.
③Output constant current setting, 0.000~5.000A, resolution 0.001A, unit A.
④Output mode, including OFF mode, constant voltage output mode CV, constant current output
mode CC, in CV mode, the brightness of output LED automatically changes with the voltage,
and CC mode automatically changes with the current.
⑤USB-A mode, including host mode USBH and slave mode USBD. In host mode, it can output
5V/1A , which can supply power to 5V devices, such as a USB mouse; in slave mode, it is
used for communication with the PC and firmware upgrading.。
⑥Working state, including seven kinds: normal state NM, overvoltage protection OVP,
overcurrent protection OCP, overpower protection OPP, overheat protection OTP, reverse
connection protection REP(can be set through menu items), undervoltage protection UVP.
When it detects other states than the normal state, the device automatically turns off the output
and alarms with a buzzer, and it is forbidden to turn on the output in the UVP state.
⑦The preset output group currently used, the device supports 10 preset groups (0~9), P[0]
represents preset group 0, each preset group includes output voltage setting, output constant
current setting, overvoltage protection setting, overcurrent protection setting.
⑧Panel lock state, gray means not locked, it turns orange after locking and operation is invalid,
it is automatically locked after connecting to the PC, and can’t be unlocked through panel.
⑨Device temperature, unit: Celsius (°C).
⑩Device output power, real-time display of the power value of the device, unit: watt (W).
⑪Device output current, real-time display the output current value, unit: ampere (A).
⑫Device output voltage, real-time display the output voltage value, unit: Volt (V).
Note: ① When disconnecting the PC, you can lock and unlock by long pressing the middle button ■; after
connecting to the PC, the middle button is invalid and cannot be unlocked through the control panel.
② When communicating with the PC or upgrading the firmware, please set the USB-A interface to slave
mode(USBD) first, then use the A-A USB cable to connect PC and DP100.
①
②
③
④
⑥
⑦
⑧
⑨
⑩
○
12
○
11
⑤

High Performance Digital Power
User Manual www.alientek.com
5
DP100 Digital Power User Manual
③ When we need output 5V from USB-A interface, or use a mouse (wired and wireless) to control the
device, please set the USB-A interface to the host mode (USBH), then connect the mouse/mouse wireless receiver.
First do not move the mouse, then roll the mouse wheel until the device emits a beeping sound (when the mouse
wheel is detected), the left, middle, right buttons and the scroll wheel of the mouse correspond to the 3 buttons and
scroll wheel of DP100 one-to-one, and the functions are the same (after shutdown or switching to slave mode, the
mouse control is invalid ).
4.2.2 Operation instructions
Click the middle button ■ to enter the parameter setting state, click ■ again to switch the
output voltage setting and constant current setting cyclically,After the parameter bit is highlighted,
click the or to move the parameter highlight position left or right, and then adjust the
highlighted value by scroll wheel, as shown in Figure 4.2.2:
Figure 4.2.2 Parameter setting
After the parameter adjustment is completed, you can long press any key to exit the
parameter setting. Timeout (8Sec) automatically exited parameter setting.
In the parameter setting state, the functions of the buttons and the scroll wheel are shown in
Table 4.2.1:
Buttons
Click
Double-Click
Long-Press
Left
Shift left the highlighted bit
None
Exit parameter setting
Middle■
Switch voltage and current parameter
None
Exit parameter setting
Right
Shift right the highlighted bit
None
Exit parameter setting
Wheel
Adjust the highlighted value
Table 4.2.1 Button and Wheel function
After exit parameter setting,buttons function are shown in Table 4.2.1:
Buttons
Click
Double-Click
Long-Press
Left
Power on while off
Change USB-A interface mode
Power off while on
Middle■
Enter parameter setting
Switch to Menu Interface
Lock/Unlock panel
Right
Enable/Disable output
Change supply voltage(PD/QC mode)
Switch to Preset Interface
Table 4.2.2 Button function
Change output mode, including OFF mode, constant voltage mode CV and constant current
mode CC, as shown in Figure 4.2.3:
Figure 4.2.3 Output mode

High Performance Digital Power
User Manual www.alientek.com
6
DP100 Digital Power User Manual
Red indicates abnormal working status, including overvoltage protection, overcurrent
protection, overpower protection, overheating protection, undervoltage protection, reverse
connection protection, and turn off the output, as shown in Figure 4.2.4:
Figure 4.2.4 Abnormal working status
USB-A mode switching, including USBD mode and USBH mode, as shown in Figure 4.2.5:
Figure 4.2.5 USB-A mode
Changing preset groups ( P[0]~P[9]), as shown in Figure 4.2.6:
Figure 4.2.6 Change Preset group
Temperature and panel lock status, as shown in Figure 4.2.7:
Figure 4.2.7 Temperature and panel lock status
4.3 Preset Interface
4.3.1 Preset interface
The preset group is used to set output parameters in advance, including output voltage
parameters, constant current parameters, overvoltage protection parameters, and overcurrent
protection parameters. DP100 supports 10 preset groups (0~9), each preset group can be set, saved,
and recalled independently. Users can set output parameters (1.8V, 3.3V, 5.0V, etc.) according to
their own needs. After setting, preset groups can be directly called out and used, and there is no
need to set voltage and current every time, which is convenient and quick.
Long press the right button and enter the Preset interface, the information of the preset
interface is shown in Figure 4.3.1:

High Performance Digital Power
User Manual www.alientek.com
7
DP100 Digital Power User Manual
Figure 4.3.1 Preset interface
①Preset[x] : Current preset group, x=0~9;
②VSET: Output voltage setting, range 00.00V~30.00V;
③OVP: Overvoltage protection setting, range 00.00V~30.50V;
④ISET: Output constant current setting, range 0.000A~5.000A;
⑤OCP: Overcurrent protection setting, range 0.000A~5.050A;
4.3.2 Operation instructions
Long press the right button and enter the preset interface, then click the middle button ■
to switch 5 parameters cyclically,After the parameter bit is highlighted, click the or to move
the parameter highlight position left or right, then adjust the highlighted value by scroll wheel, as
shown in Figure 4.3.2:
Figure 4.3.2 Parameter adjustment
After the parameters are adjusted, long press the middle button ■ to save the current preset
group parameters, long press the left button to cancel preset group parameters saving and return
to the main interface, long press the right button to recall current preset group parameters and
return to the main interface. Timeout (6Sec) doesn’t save the current preset group parameters and
returns to the main interface.
Buttons and Wheel function of preset interface as shown in table 4.3.1:
Buttons
Click
Double-Click
Long-Press
Left
Shift left the highlighted bit
None
Cancel saving and return to main interface
Middle■
Circular switch 5 parameters
None
Saving current group parameters
Right
Shift right the highlighted bit
None
Recall current group and return to main interface
Wheel
Change Preset group / Adjust the highlighted value
Table 4.3.1 Buttons and Wheel function

High Performance Digital Power
User Manual www.alientek.com
8
DP100 Digital Power User Manual
4.4 Menu Interface
4.4.1 Menu interface
The menu has a total of 15 items, including some common setting items. Double-click the
middle button ■to enter menu interface. The menu interface is shown in Figure 4.4.1:
Figure 4.4.1 Menu interface
The explanation of menu items, the adjustable range and factory settings are shown in Table
4.4.1:
Items
Paraphrase
Factory settings
Range
1. Exit
Exit menu setting
2. OVP Setting
Setting current group OVP
30.50V
00.00V~30.50V
3. OCP Setting
Setting current group OCP
5.050A
0.000A~5.050A
4. OPP Setting
Setting all group OPP
105.0W
000.0W~105.0W
5. OTP Setting
Setting all group OTP
80℃
50℃~80℃
Step 5℃
6. REP Setting
Turn on/off reverse protection function
ON
⚫ON
⚫OFF
7. AUTO_Out
Turn on/off automatic output function
upon startup
OFF
⚫ON
⚫OFF
8. Working voltage
Setting the working voltage when use
PD/QC adapter
The highest
voltage the
adapter can output
⚫9V
⚫12V
⚫15V
⚫20V
9. Backlight setting
Setting backlight brightness
Level 2
Level 0~4
10. Volume setting
Setting the buzzer volume
Level 2
Level 0~4
11. USB mode
Setting USB-A mode
Slave mode
USBD
⚫Slave USBD
⚫Host USBH
12. Language
setting
Setting menu language
简体中文
⚫简体中文
⚫English
⚫繁体中文
13. Theme color
Setting theme color
WHITE
⚫WHITE
⚫BLACK

High Performance Digital Power
User Manual www.alientek.com
9
DP100 Digital Power User Manual
14. Set default
Restore the configuration parameters to
the factory state
NO
NO/YES
15. Version info
Show the software and hardware version
V1.0_1.1
Table 4.4.1 Menu instructions
Notes:
① The working voltage is only valid when using the PD/QC power adapter. By default, using
the highest voltage which the adapter can provide. If the adapter can only output a maximum voltage
of 12V, even if setting working voltage to 20V, the actual working voltage can only be 12V.
② USB-A interface mode, in slave mode(USBD), the device can communicate with the PC, and
used to firmware upgrade; Setting to host mode(USBH), it can output 5V/1A, which can be used to
supply power to 5V devices, such as wired/wireless mouse, etc.
4.4.2 Operation instructions
On the main interface, double-click the middle button■to enter the menu interface, then
scroll the wheel to select different menu items, click the ■ to set the parameters of the current
menu item. If the adjustable bit of the parameter is greater than 1, you can click the or to
move the parameter highlight position left or right , then adjust the highlighted value by scroll
wheel. After the parameter is adjusted, click the ■to exit the parameter setting. Timeout (6Sec)
will also automatically Exit parameter setting.
After exiting the parameter setting, long press ■ or click ■ on the "Exit" menu item to
exit the menu interface and return to the main interface . Timeout (6Sec) automatically return to
the main interface.
After entering the parameter setting state, long-press and double-click operations of all
buttons are invalid.

High Performance Digital Power
User Manual www.alientek.com
10
DP100 Digital Power User Manual
5,ATK-DP100 Instructions
5.1 Basic function interface
5.1.1 Basic function
The basic function interface is shown in Figure 5.1.1:
Figure 5.1.1 Basic function interface
①Language setting: Supports English, Simplified Chinese, and Traditional Chinese
②Device information column: including device type, version information and serial number
③Waveform display area: including voltage and current waveforms. When one of the
waveforms is checked separately, the waveform will be automatically zoomed and displayed. You
can also zoom and drag the mouse to view it. Press and hold the right mouse button to view the
voltage, current, and time of the current point.
There are 3 waveform rates: low, middle, fast
Optional display of X-axis and automatic data saving (csv format)
The waveform display can be refreshed and paused by pressing the Start/Pause button (the
waveform will only be paused when the whole screen is covered); click the recycle button to clear
the curve data and refresh the display. If the auto-save data is checked, the waveform data will be
re-saved in segments.
④Basic information column: including input voltage, output voltage, output current, output
power and system temperature.
⑤Preset group: The preset group is used to set output parameters in advance, including
output voltage parameters, constant current parameters, overvoltage protection parameters, and
overcurrent protection parameters. DP100 supports 10 preset groups (0~9, ATK-DP100 can only
set the group 1 to group 9, the 0th group is reserved), each preset group can be set, saved, and

High Performance Digital Power
User Manual www.alientek.com
11
DP100 Digital Power User Manual
recalled separately, Users can set output parameters (1.8V, 3.3V, 5.0V, etc.) according to their own
needs. After setting, preset groups can be directly called out and used, and there is no need to set
voltage and current every time, which is convenient and quick.
⑥ Output voltage setting and constant current setting: Change the output voltage and
constant current value of the current preset group (only change and not save, and the initial value
is still the same after the DP100 is restarted).
⑦ System parameters: including overheat protection parameter setting (50~80℃), overpower
protection parameter setting (≤105.0W), backlight brightness level (0~4), buzzer volume level
(0~4), Rep setting(ON/OFF),Auto out setting(ON/OFF).
⑧ Status/On-Off column: There are three output modes: OFF, CV, CC; the working status
includes normal status NM, overvoltage protection status OVP, overcurrent protection status OCP,
overpower protection status OPP, overheat protection status OTP, undervoltage protection status
UVP, reverse connection protection state REP; Output indication includes three states: open, close,
and under-voltage lockout (when input voltage <4.8V).
Notes:
① After connecting to ATK-DP100, the control panel is automatically locked, and the device cannot be
operated from the control panel.
② If auto-save is selected, a large csv file will be generated on disk at high refresh rate.
5.2 Advanced function interface
5.2.1 Advanced function
The advanced function is convenient for users to output the setting data according to the
timing. The interface is shown in Figure 5.2.1:
Figure 5.2.1 Advanced function Interface
① Sequence output: First set the output voltage, current and delay, select the serial number
range and cycle times.

High Performance Digital Power
User Manual www.alientek.com
12
DP100 Digital Power User Manual
The serial number range is 001~200; the voltage setting (V-Set) range is 00.00V~30.00V; the
constant current setting (I-Set) range is 0.000A~5.000A; the delay range is 0001S~9999S; the
number of cycles and the current cycle range are 001~ 999; start serial number, end serial number,
current serial number range 001~200;
Click to start button to execute the sequence output (other interfaces are locked and invalid),
executed sequence numbers shows OK, and unexecuted sequence numbers show waiting. Click
pause button to keep the current serial number output; click continue button to execute the
following sequence according to the delay; click end button to end the sequence output and close
the output.
② Current scan output: The voltage is fixed, the current is scanned and output according to
the step current and delay, which is often used in the constant current mode. The voltage setting
needs to be greater than 0V; the starting current and ending current range is 0.000A~5.000A (if the
starting and ending values are the same, it is invalid); the step current range is 0.001A~5.000A;
the output time is 0001S~9999S;
Click start button to execute scan output (other interfaces are locked and invalid), click stop
button to stop the scan and turn off the output.
③ Voltage scan output: The current is fixed, the voltage is scanned and output according to
the step voltage and delay, which is often used in the constant voltage mode. The current setting
needs to be greater than 0A; the starting voltage and ending voltage range is 00.00V~30.00V (if
the starting and ending values are the same, it is invalid); the step voltage range is 00.00V~30.00V;
the output time is 0001S~9999S;
Click start button to execute scan output (other interfaces are locked and invalid), click stop
button to stop the scan and turn off the output.
5.3 Firmware upgrade interface
5.3.1 Firmware upgrade
DP100 firmware update supports two upgrade modes: local mode and remote mode.
Local mode: Download the firmware you need (.atk file, the download address is in Chapter
7 of this document) from the download link we provided, and then upgrade according to the
operation shown in Figure 5.3.2.
Remote mode: ATK-DP100 automatically obtains the latest firmware from the server and
prompts the firmware version, without downloading the latest firmware by yourself. Other
operations are the same as in local mode.
The remote mode upgrade process is shown in Figure 5.3.1 (requires networking):

High Performance Digital Power
User Manual www.alientek.com
13
DP100 Digital Power User Manual
Figure 5.3.1 Remote firmware upgrade
5.3.2 Instructions
① Click Firmware Update options, the firmware update window will pop up;
② Select the remote mode, then ATK-DP100 will automatically load the latest firmware through
the network;
③ Click to start the upgrade button. Start firmware upgrading when the firmware matches. If the
current software version of the device is the same as the software to be upgraded, it will prompt to
cancel or force upgrading, and you can choose one of them.
④ Firmware update log, detailing the updated content
Notes:
① If using the local mode, You needs to download the latest firmware (.atk file, the download address is in
Chapter 7 of this document) from the download link we provided.
② If the upgrade process crashes, first unplug the Type-C power supply and the A-A USB cable of DP100, then
press and hold the left button, insert the A-A USB cable and then release the button, DP100 is forced Enter the
BOOT mode, and finally connect to ATK-DP100 to perform the firmware upgrade operation.
5.4 Software update interface
5.4.1 Software update
ATK-DP100 software will also be updated from time to time. Click on the software update
option to view the latest software version and software update content through the log.
If necessary, click "Download the latest version to the local" to download (requires internet
connection), as shown in Figure 5.4.1:

High Performance Digital Power
User Manual www.alientek.com
14
DP100 Digital Power User Manual
Figure 5.4.1 Software Update Interface

High Performance Digital Power
User Manual www.alientek.com
15
DP100 Digital Power User Manual
6,FAQ
The summary of common problems is shown in Table 6.1:
Table 6.1 Summary of issues
Problems and phenomena
Solution
OCP/OVP/OPP/OTP Promote
Check if the output parameters are higher than the set protection
parameters, and set the protection parameters reasonably
REP/UVP Promote
REP: Check if the output terminal is reversed, UVP: Check if
TypeC has correct power input
Connection failure of PC
Check if the USBA-A cable is used correctly and if the USB mode
is USBD
Enter CC mode when output
Check if the ISET is set too small and increase the ISET value
appropriately
No actual voltage output
1. Check if VSET is set to 0
2. Contact after-sales service
The device cannot be turned on
1. Check if the TypeC power supply is normal
2. Check if the device has been turned off, and short press the left
button to turn it on
3. Contact after-sales service
Display current greater than
1mA after closing the output
Contact after-sales service
Display current greater than
1mA without load
Contact after-sales service

High Performance Digital Power
User Manual www.alientek.com
16
DP100 Digital Power User Manual
7,Serivices
1. After – sales Service:
DP100 host has a one-year free warranty service in the case of non-artificial
damage. Please contact the dealer for warranty service.
2. Website
Download : www.alientek.com/download
Company : www.alientek.com
Aliexpress : www.aliexpress.com/store/1102909571
3. Contact US
E-mail : fae-smt@alientek.com
Table of contents
Popular Portable Generator manuals by other brands

Intellijel
Intellijel Quadrax manual

Generac Power Systems
Generac Power Systems XG7000E XG SERIES specification

Siemens
Siemens SINAMICS S120 manual

Craftsman
Craftsman 580.327122 owner's manual

Intelligent Energy
Intelligent Energy FCM-802 user manual

Keysight Technologies
Keysight Technologies E8257N Installation note