ALL POWER AMERICA APG3002 User manual

ÛN8KKÛ><E<I8KFI
N@K?ÛDF9@C@KPÛB@K
70
8G>
Fof]j¿kÛDYfmYd

.:*(1(5$725
7DEOHRI&RQWHQWV
7RSLF3DJH
6DIHW\*XLGHOLQHV²'HILQLWLRQV
*HQHUDO3UHFDXWLRQV
$VVHPEO\
6SHFLILFDWLRQV
*HQHUDO3DUWV/LVWLQJ
(QJLQH3DUWV/LVWLQJ
,QVWDOODWLRQ
2SHUDWLRQ
,QVSHFWLRQ&OHDQLQJDQG0DLQWHQDQFH
&RPSOLDQFH
/LPLWHG:DUUDQW\

Owner’s Manual
3
Safety Guidelines - Definitions
This manual contains important information that you need to know and
understand in order to protect YOUR SAFETY and to PREVENT
EQUIPMENT PROBLEMS. The following symbols help you recognize this
information. Please read the manual and pay attention to these sections.
Save These Important Safety
Instructions!
Read and understand all of these safety instructions. Be
sure to retain them for future use.
WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG
POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS
ARE NOT FOLLOWED.
CAUTION: CAUTIONS INDICATE A POSSIBILITY OF
EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT
FOLLOWED.
Note: Notes give helpful information.
WARNING! IMPROPER OPERATION OR MAINTENANCE OF THIS
PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY
DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING
INSTRUCTIONS BEFORE USING THIS EQUIPMENT. WHEN USING AIR
TOOLS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY.
General Precautions
WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN
RESULT IN SEVERE INJURY OR DEATH.
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS
CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE
ITEM YOU ARE WORKING ON.

3.5KW Generator
4
Carbon Monoxide
When this tool is running, ensure that the area is well
ventilated. Never run the engine in an enclosed area. Run the
engine in an open area or with an exhaust evacuation system
in an enclosed area.
Gasoline and Oil
This product requires oil and fuel. Attempting to start the
engine without oil will ruin the engine and void the warranty.
Work in well ventilated area. Keep cigarettes, flames or
sparks away from the work area or where gasoline is stored.
Gasoline fuel and fumes are flammable and potentially explosive. Use
proper fuel storage and handling procedures. Always have multiple ABC
class fire extinguishers nearby.
Keep the generator and surrounding area clean at all times.
Fuel or oil spills must be cleaned up immediately. Dispose of fluids and
cleaning materials as per any local, state, or federal codes and
regulations. Store oily rags in a covered metal container.
Never store fuel or other flammable materials near the generator.
WARNING! THE EXHAUST CONTAINS POISONOUS CARBON
MONOXIDE GAS THAT CAN CAUSE LOSS OF CONSCIOUSNESS AND
MAY LEAD TO DEATH.
WARNING! GASOLINE IS EXTREMELY FLAMMABLE AND IS
EXPLOSIVE UNDER CERTAIN CONDITIONS. KEEP OUT OF REACH OF
CHILDREN.
Do not smoke, or allow sparks, flames or other sources of ignition
around the engine and fuel tank. Fuel vapors are explosive.
Keep grounded conductive objects, such as tools, away from exposed,
live electrical parts and connections to avoid sparking or arcing. These
events could ignite fumes or vapors.
Do not refill the fuel tank while the engine is running or while the engine
is still hot. Do not operate the generator with known leaks in the fuel
system.
Use only engine manufacturer recommended fuel and oil.

Owner’s Manual
5
General Precautions (cont’d)
Gasoline and Oil (cont’d)
Excessive buildup of unburned fuel gases in the exhaust system can
create a potentially explosive condition. This buildup can occur after
repeated failed start attempts, valve testing, or hot engine shutdown. If
this occurs, open exhaust system drain plugs, if equipped, and allow the
gases to dissipate before attempting to restart the generator.
Hot Components
Power Output
This generator is not designed to power sensitive electronic equipment
(including computers and medical devices) without the addition of an
approved line conditioner, which is sold separately.
WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY
HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN.
WEAR INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND
EXHAUST SYSTEM HAVE COOLED BEFORE HANDLING THESE
PARTS.
CAUTION: ATTEMPTING TO POWER SENSITIVE
ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN
APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO
THE EQUIPMENT. NIKOTA USA IS NOT RESPONSIBLE FOR
ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE
TO USE AN APPROVED LINE CONDITIONER.
Work Area
Keep your work area clean and well lit. Cluttered benches
and dark areas invite accidents.
Do not operate power tools in explosive atmospheres,
such as in the presence of flammable liquids, gases, or
dust. Generators create sparks which may ignite the dust or fumes.
Keep bystanders, children, and visitors away while operating a
generator. Provide barriers or shields as needed.

3.5KW Generator
6
Electrical Safety
Grounded tools must be plugged into an outlet properly
installed and grounded in accordance with all codes and
ordinances. Never remove the grounding prong or modify
the plug in any way. Do not use any adapter plugs.
Grounding provides a low-resistance path to carry electricity away from
the user inthe event of an electrical malfunction.
Double insulated tools are equipped with a polarized plug where one
blade is wider than the other. This plug fits in a polarized outlet only one
way. If the plug does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician to install a polarized outlet. Do
not change the plug in any way. Double insulation eliminates the need
for the three-wire grounded power cord and grounded power supply
system.
Avoid body contact with grounded surfaces such as pipes, radiators,
ranges, and refrigerators. There is an increased risk of electric shock if
your body is grounded.
Do not expose generator to rain or wet conditions. Water entering a
generator will increase the risk of electric shock.
Do not abuse the power cord. Keep power cords away from heat, oil,
sharp edges, or moving parts. Replace damaged power cords
immediately. Damaged power cords increase the risk of electric shock.
When operating a power tool outside, use an outdoor extension cord
marked “W-A” or “W”. These extension cords are rated for outdoor use,
and reduce the risk of electric shock.
All connections and conduits from the generator to the load must only be
installed by trained and licensed electricians, and in compliance with all
relevant local, state, and federal electrical codes and standards, and
other regulations where applicable.
The generator must be earth-grounded for fixed installations in
accordance with all relevant electrical codes and standards before
operation.
Do not attempt to connect or disconnect load connections while standing
in water, or on wet or soggy ground.
Do not touch electrically energized parts of the generator and
interconnecting cables or conductors with any part of the body, or with
any non-insulated conductive object.

Owner’s Manual
7
General Precautions (cont’d)
Electrical Safety (cont’d)
Before servicing equipment powered by the generator, disconnect the
equipment from its power input.
Keep all electrical equipment clean and dry. Replace any wiring where
the insulation is cracked, cut abraded or otherwise degraded. Replace
terminals that are worn, discolored, or corroded. Keep terminals clean
and tight.
Insulate all connections and disconnected wires.
Guard against electric shock. Prevent body contact with grounded
surfaces such as pipes, radiators, ranges, and refrigerator enclosures.
Personal Safety
Stay alert. Watch what you are doing, and use common
sense when operating a generator. Do not use generator
while tired or under the influence of drugs, alcohol, or
medication. A moment of inattention while operating
generators may result in serious personal injury.
Dress properly. Do not wear loose clothing or jewelry. Contain long hair.
Keep your hair, clothing, and gloves away from moving parts. Loose
clothes, jewelry, or long hair can be caught in moving parts.
Avoid accidental starting. Make sure the power switch is in its “OFF”
position, and disconnect the spark plug wWire when not in use.
Remove adjusting keys or wrenches before turning the generator on. A
wrench or a key that is left attached to a rotating part of the generator
may result in personal injury.
Do not overreach. Keep proper footing and balance at all times.
Use safety equipment. Always wear eye protection. Wear ANSI
approved safety impact eye goggles. Dust mask, non-skid safety shoes,
hard hat, or hearing protection must be used for appropriate conditions.
Do not force the generator. Use the correct generator for your
application. The correct generator will do the job better and safer at the
rate for which it is designed.
Do not use the generator if the power switch does not turn it on or off.
Any generator that cannot be controlled with the power switch is
dangerous and must be replaced.

.:*(1(5$725
*HQHUDO3UHFDXWLRQVFRQW
G
*HQHUDWRU8VHDQG&DUH
0DNHVXUHWKHSRZHUVZLWFKLVLQLWV h2))vSRVLWLRQDQGGLVFRQQHFW
WKHVSDUNSOXJZLUHEHIRUHPDNLQJDQ\DGMXVWPHQWFKDQJLQJ
DFFHVVRULHVRU6WRULQJWKHJHQHUDWRU6XFKSUHYHQWLYHVDIHW\
PHDVXUHVUHGXFHWKHULVNRIVWDUWLQJWKHJHQHUDWRUDFFLGHQWDOO\
6WRUHLGOHJHQHUDWRUVRXWRIUHDFKRIFKLOGUHQDQGRWKHUXQWUDLQHG
SHUVRQV*HQHUDWRUVDUHGDQJHURXVLQWKHKDQGVRIXQWUDLQHGXVHUV
0DLQWDLQJHQHUDWRUVZLWKFDUH'RQRWXVHGDPDJHGJHQHUDWRU7DJ
GDPDJHGJHQHUDWRUV h'RQRWXVHv XQWLOUHSDLUHG
&KHFNIRUPLVDOLJQPHQWRUELQGLQJRIPRYLQJSDUWVEUHDNDJHRISDUWV
DQGDQ\RWKHUFRQGLWLRQWKDWPD\DIIHFWWKHJHQHUDWRUVRSHUDWLRQ,I
GDPDJHGKDYHWKHJHQHUDWRUVHUYLFHGEHIRUHXVLQJ0DQ\DFFLGHQWV
DUHFDXVHGE\SRRUO\PDLQWDLQHGJHQHUDWRUV
8VHRQO\DFFHVVRULHVWKDWDUHUHFRPPHQGHGE\WKHPDQXIDFWXUHUIRU
\RXUPRGHO$FFHVVRULHVWKDWPD\EHVXLWDEOHIRURQHJHQHUDWRUPD\
EHFRPHKD]DUGRXVZKHQXVHGRQDQRWKHUJHQHUDWRU
6HUYLFLQJ
0DLQWDLQODEHOVDQGQDPHSODWHVRQWKHJHQHUDWRUDQGHQJLQH7KHVH
FDUU\LPSRUWDQWLQIRUPDWLRQ,IXQUHDGDEOHRUPLVVLQJFRQWDFW
$//32:(5$0(5,&$LPPHGLDWHO\IRUDUHSODFHPHQW
*HQHUDWRUVHUYLFHPXVWEHSHUIRUPHGRQO\TXDOLILHGUHSDLUSHUVRQQHO
6HUYLFHRUPDLQWHQDQFHSHUIRUPHGE\XQTXDOLILHGSHUVRQQHOFRXOGUHVXOW
LQDULVNRILQMXU\
:KHQVHUYLFLQJDJHQHUDWRUXVHRQO\LGHQWLFDOUHSODFHPHQWSDUWV
)ROORZDOODSSURSULDWHLQVWUXFWLRQVLQWKLVPDQXDO8VHRIXQDXWKRUL]HG
SDUWVRUIDLOXUHWRIROORZPDLQWHQDQFHLQVWUXFWLRQVPD\FUHDWHDULVNRI
HOHFWULFVKRFNRULQMXU\
+HDUW3DFHPDNHUV
:$51,1*3(23/(:,7+3$&(0$.(566+28/'&2168/77+(,5
3+<6,&,$16%()25(86,1*7+,6352'8&7(/(&7520$*1(7,&
),(/'6,1&/26(352;,0,7<72$+($573$&(0$.(5&28/'
&$86(,17(5)(5(1&(7225)$,/85(2)7+(3$&(0$.(5

Owner’s Manual
9
General Precautions (cont’d)
Installation
Ensure installation meets all applicable safety, and local and national
electrical codes. Have installation performed by a qualified, licensed
electrician and building contractor.
All electrical work, including the earth-ground connection, should be
completed by a licensed electrician.
Any separate fuel storage or generator supply facility must be built or
installed in full compliance with all relevant local, state, and federal
regulations.
It is recommended to use the generator only in well ventilated outdoor
areas. A running gasoline engine will generate carbon monoxide, a
colorless, odorless gas that, if inhaled, can cause serious injury or
death. If the generator is installed indoors, exhaust fumes must be piped
out of the building using leak-free, heat resistant piping. Pipes and
silencer should not use any flammable materials, nor should they be
installed near the same. Generator exhaust fumes must be within legal
limits and installation must always meet local building codes.
If the generator is installed outdoors, it must be weatherproofed and
should be soundproofed. It should not be run outdoors without
protection to the generator and wiring conduit.
The generator's weight is very heavy. Two or more people should assist
when moving or lifting this product without using the wheels. Never lift
the Generator using the engine or alternator lifting lugs. Connect lifting
equipment to the frame of the generator.
Before lifting the generator, ensure the lift rigging and supporting
structure are in good condition, and are rated to lift such a load.
Keep all personnel away from the suspended generator during
relocating.
The supporting floor/ground surface should be level, and strong enough
to safely hold the weight of the generator. If the floor/grounded surface is
not level, strong cross members should be placed under the full length
of the generator frame at its low side.
For trailer installation, the generator should be mounted on the center
point of the trailer, over the wheels. The trailer must be capable of
supporting the weight of the generator and all contents (tools, etc.)
Install sound-and weather-proofing only when it is not raining or snowing
to avoid trapping moisture within the generator’s area.

3.5KW Generator
10
General Precautions (cont’d)
Mechanical
Always make sure the power switch is in its “OFF” position. Disconnect
the spark plug wire, and allow the engine to completely cool before
carrying out maintenance.
Check for damaged parts. Before using the generator, any part that
appears damaged should be carefully checked to determine that it will
operate properly and perform its intended function. Check for alignment
and binding of moving parts, any broken parts or mounting fixtures, and
any other condition that may affect proper operation technician.
The generator is designed with guards for protection from moving parts.
In any case, care must still be taken to protect personnel and equipment
from other mechanical hazards when working around the generator.
Do not operate the generator with safety guards removed. While the
Generator is running, do not attempt to reach around the safety guard
for maintenance or any other reason.
Keep hands, arms, long hair, loose clothing, and jewelry away from
moving parts. Be aware that when engine parts are moving fast they
cannot be seen clearly.
Keep access doors on enclosures closed and locked when access is not
required.
When working on or around the generator always wear protective
clothing including ANSI approved safety gloves, safety eye goggles, and
safety hat.
Do not alter or adjust any part of the generator that is assembled and
supplied by the manufacturer.
Always follow and complete scheduled engine and generator
maintenance.
Chemicals
Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces.
Avoid body contact with fuels, oils, and lubricants used in the generator.
If swallowed, seek medical treatment immediately. Do not induce
vomiting if fuel is swallowed. For skin contact, immediately wash with
soap and water. For eye contact, immediately flush eyes with clean
water and seek medical attention.

Owner’s Manual
General Precautions (cont’d)
Noise
Prolonged exposure to noise levels above 85 dBA is hazardous to hearing.
Always wear ANSI approved ear protection when operating or working
around the Generator when it is running.
Extension Cord
If an extension cord (not included) is used, make sure to use only UL
approved cords having the correct gauge and length according to the
following table:
NameplateAmps (@ Cord Lengths
full load)
0’-50’ 50’-100’ 100’-150’ 150’-200’
0-5 16 16 12 12
5.1-8 16 14 10 -
8.1-12 14 12 - -
12.1-15 12 10 - -
15–20 10 10 - -
Assembly
Wheel and Handle Assembly
Confirm that the following sub-assembly components are included:
z 2 Heavy Duty Wheels
z 6 V-Leg Mounting Bolts /Nuts-M6
z 1 Handle
z 1 Handle Rubber Mount
z 2 V-Leg Cushions
z 2 spring washers-¶16
z 2 Wheel Axles
z 1Handle Mounting Bolt/Nut-M8
z 2 Support V-Legs
z 2 Wheel Axle Bolt Mounting Nuts
z 1Handle Rubber Mount Mounting Bolts
/Nuts-M6

3.5KW Generator
Assembly (cont’d)
Wheel Assembly
Perform the following tasks to install the heavy duty wheels onto the generator
assembly(s
see Fig.2 Fig.3
):
1. Insert axles through brackets located on frame at bottom of generator and
twist the mounting nuts onto each end of axle.
2. Insert wheels on the opposite end of the axles and twist the mounting nuts untile
the nut is fully seated against wheel hub.
Handle Assembly
Perform the following tasks to install the handle onto the generator frame(s
see
Fig.1
):
1. Insert mounting bolt (M8)completely through handle and bracket.
2. Install a mounting nut onto bolt and tighten, making sure handle can
swivel.
V- Leg Support Assembly
Perform the following tasks to install the V-leg support bracket(s
see Fig.4
):
1. Place V- leg support with mounting holes aligned with the mounting
holes in the bottom of the frame.
2. Insert one mounting bolt completely through each mounting hole.
3. Twist mounting screws to catch the threads in the frame mounted
fasteners and tighten until support leg is secure.
12

Owner’s Manual
Fig1
sub-assembly components:
1 Handle
1Handle Mounting Bolt/Nut-M8
Fig2
sub-assembly components:
2 Wheel Axles
2 spring washer ï16
Fig4
sub-assembly components:
2 Support V-Legs
4 V-Leg Mounting Bolts /Nuts-M6
Fig3
sub-assembly components:
2 Heavy Duty Wheels
2 Wheel Axle Mounting Nuts-M16

/WNERS -ANUAL
3PECIFICATIONS
!#ELECTRICAL
#URRENTOUTPUT6!# !(Z
#ONTINUOUSRATEDWATTAGE
0EAKWATTAGE
/UTLETS4WO6!#SPRINGGROUNDED
/NE6!#TWISTANDLOCKSPRINGGROUNDED
$#ELECTRICAL
#URRENTOUTPUT6$# !
'ASOLINEENGINE
(ORSEPOWER(0
4YPECYCLE/(6AIRCOOLEDRECOILSTART
$ISPLACEMENTCC
/ILCAPACITYQUARTLITER
%0!APPROVEDYES
&UEL
4YPEUNLEADEDGASOLINE
#APACITYGALLONSLITERS
2UNNINGTIMEHOURFULLLOAD APPROX
&UELGAUGEINCLUDED
7EIGHT
!PPROXIMATEWEIGHTLBS

3.5KW Generator
General Parts Listing(Fig.A)
This list is provided for reference purposes only. All repairs and part
replacement should be performed by a qualified technician. Some parts
may not be available as single replacements.
15
50

Owner’s Manual
General Parts Listing (cont’d)
# Item Qty. # Item Qty.
1 Boltw/Lock 9 19 BoltM4x16 3
WasherM6x12
2 Engine Power 1 20 Cable Sheath 1
Switch
3 AC Protector 2 21 Bolt M8x242 1
4 Voltage-on button 1 22 Bolt M6x172 4
5 DCoutlet 1 23 BoltM5x20 4
6 120/240V Outlet 1 24 ConnectionBoard 1
7 V-leg support 2 25 Nut (M5) 4
8 V-legcushion 2 26 Stator 1
9 Wheel Axle 2 27 Rotor 1
10 Locknut 4 28 Cooling Fan 1
11 ShockAbsorber 4 29 InsulationBoard 1
12 Shock Absorber 4 30 Fuel Tank 1
Foot
13 Lock Washer Nut 4 31 Fuel Filter 1
14 StatorCover 1 32 SealRing 1
15 Alternator Back 1 33 Fuel Tank cap 1
Cover
16 Capacitor 1 34 Fuel Gauge 1
17 BoltM5x16 4 35 BoltM6x12 2
18 Rectifier 1 36 LockBoltM6x12 4
16

3.5KW Generator
General Parts Listing (cont’d)
# Item Qty. # Item Qty.
37 Spacer 4 44 120V outlet 1
38 RubWasher 4 45 Indicator 1
39 Bushing 4 46 Grounding bolt 1
40 Fuel Valve 1 47 Wheel 2
41 Frame 1 48 Handle grip 1
42 Contol board 1 49 Rubber mount 1
43 Engine 1 50 Voltage-selector 1
17

Owner’s Manual
Engine Parts Listing (Fig. B)
This list is provided for reference purposes only. All repairs and part
replacement should be performed by a qualified technician. Some parts
may not be available as individual replacements.
18

3.5KW Generator
19
Engine Parts Listing (cont'd)
# Item Qty. # Item Qty.
1
Muffler
114Carburetor
Assembly
1
2 Cylinder Head
Bolt
4 15 Air Cleaner Case 1
3 Cylinder Head
Cover Bolt
4 16 Air Cleaner Seal 1
4 Cylinder Head
Cover
1 17 Air Cleaner 1
5 Lock Nut 2 18
Air Cleaner Cover
1
6 Adjusting Screw 2 19 Air Cleaner
Element
1
7 Rocker Arm 3 20 Bolt M6
Separator
4
8 Rocker Arm Bolt 2 21 Choke Lever 1
9 Valve Push Rod
Guiding Board
122Carburetor
Packing
1
10 Valve Push Rod 2 23 Stud Bolt M6.109 2
11 Cylinder Head 1 24 Intake Valve 1
12 Carburetor
Shield
125ExhaustValve1
13 Carburetor
Packing
1 26 Cylinder Head
Gasket
1

Owner’s Manual
20
Engine Parts Listing (cont’d)
# Item Qty. # Item Qty.
27 Exhaust Pipe
Stud
2 42 Starting Case
Assy.
1
28 Spark Plug 1 43 Spiral Spring 1
29 Valve Guide 2 44 Starting Wheel 1
30 Valve Spring 2 45 Circlip 1
31
Rocker Shaft
Circlip
2 46 Starting Ratchet 2
32 Valve Stem
Protector
2 47 Friction Plate
Screw
1
33 Cylinder Head
Cover Packing
148
Cover
1
34 Governor Spring 1 49 Starter Pulley 1
35 Bolt 1 50 Cooling Fan 1
36 High Tension
Line
1 51 Flywheel
Magneto
1
37 Ignition Coil 1 52 Cylinder Block 1
38 Nut (Special
14mm)
1 53 Speed Control
Lever
1
39 Starter Ratchet
Spring
2 54 Governor Arm 1
40 Start Rope 1 55 Governor Spring 1
41 Start Handle 1 56 Governor
Support
1
57 Bolt M6x15 2 58 Oil Alert Nut 1
Table of contents
Other ALL POWER AMERICA Portable Generator manuals
Popular Portable Generator manuals by other brands

DUROMAX
DUROMAX XP12000E user manual

Craftsman
Craftsman 580.329100 owner's manual

Porter-Cable
Porter-Cable A02871-043-0 instruction manual

REV Ritter
REV Ritter CSM24U instruction manual

EWM
EWM Tetrix XQ 300 puls DC Comfort 3.0 operating instructions

Peak Scientific
Peak Scientific FUSION 1010 installation guide