Allonge ALG-KW1102EU User manual

ALG-KW1102EU
English
Ultrasonic Humidifier ALG-KW1102EU
User’s Manual
Thank you for purchasing Ultrasonic Humidifier ALG-KW1102EU.
Be sure to read this User’s Manual carefully to ensure the correct
use. After reading this manual, keep it in a safe place for future
reference.
Novis Electronics AG
Imported and distributed by
03ALG-KW1102EU3LEnFrGe.indbEn103ALG-KW1102EU3LEnFrGe.indbEn1 2012/06/2018:47:102012/06/2018:47:10

En 2
English
Safety Information
Before use, be sure to read the information on safety carefully to ensure that you use•
this product correctly. Always follow this information when using this product.
WARNING
Do not disassemble. This product may only be disassembled by
qualified repair technicians.
Attempting to disassemble this product can cause a fire, electrical shock, or injury. To request
repair, please contact the dealer where you purchased the product.
Do not use when the power cord or power plug is damaged, or the
plug is inserted loosely into the outlet.
This can result in an electrical shock, short-circuit, or start a fire.
Do not scratch, damage, modify, forcibly bend, pull, twist, or bind the
power cord, or place heavy objects on or clamp the power cord.
This could damage the power cord and result in a fire or electrical shock.
Do not insert metal objects, such as pins and wires, or other foreign
objects inside the gaps in the product.
This could result in an electrical shock or malfunction.
Do not allow children to use this product by themselves, and keep out
of the reach of small children.
Otherwise, a burn or other injury or electrical shock could result.
Use with the designated power supply only (220 – 240 V ac).
Otherwise, this could result in a fire or breakdown.
CAUTION
When cleaning the product, for safety’s sake be sure to unplug it from
the outlet.
Do not use in locations with high humidity (85% or higher).
Do not use in locations where the steam mist directly contacts
furniture, walls, curtains, ceiling, or other objects.
Do not place on slanted surfaces, high locations such as bookshelves,
or on unstable surfaces.
Do not block the mist outlet.
Use clean water only.
Do not use hot water.
Use of hot water that is 40°C or higher can cause deformation or malfunction of the product.
03ALG-KW1102EU3LEnFrGe.indbEn203ALG-KW1102EU3LEnFrGe.indbEn2 2012/06/2018:47:112012/06/2018:47:11

En 3
English
Never put aroma oil or other fragrances into the water tank.
Do not use the product by placing it directly onto a carpet or other
object with soft fibers.
Do not wipe with benzene or thinner.
When unplugging the power cord, always unplug by grasping the
power plug, not by pulling on the power cord.
Throw away the water when not using the product.
Replace the water in the water tank and water tub with new water
everyday. Clean regularly to ensure that the inside of the product is
always clean.
Do not place cell phones, computers, or other electronic devices near
the humidifier.
Because the area around the humidifier can become very humid while the humidifier is operating,
do not place cell phones, computers or other electronic devices that are sensitive to humidity near
the humidifier.
Be careful that the product does not freeze.
If the product is placed in a location subject to freezing temperatures, throw away the water inside.
Place this product in a location that is at least two meters away from
televisions, radios, and other electronics.
Do not tilt the product.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
Correct Disposal of this product.
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible harm to
the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
03ALG-KW1102EU3LEnFrGe.indbEn303ALG-KW1102EU3LEnFrGe.indbEn3 2012/06/2018:47:112012/06/2018:47:11

En 4
English
Names of Parts and Their Functions
Mist cone
Water tank handle
This is used when carrying the water tank.
(The handle is on the opposite side to the controls.)
Water tank
Mist outlet
Power
cord
Fan outlet
Humidifier
Power plug
Mist hole
Air inlet
03ALG-KW1102EU3LEnFrGe.indbEn403ALG-KW1102EU3LEnFrGe.indbEn4 2012/06/2018:47:112012/06/2018:47:11

En 5
English
Inside of body
Water level sensor
Water drain direction arrow indicator
(When draining water, do so in the
direction indicated by the arrow)
Fan outlet
Water tub
Ultrasonic vibration plate
Overflow drain
Water tank back side
Mist hole
Water tank cap
CAUTION
Take care not to get water in the fan outlet or overflow drain during draining or
cleaning.
Otherwise, malfunction could result.
Accessories
Aroma base
Replacement felt × 2
03ALG-KW1102EU3LEnFrGe.indbEn503ALG-KW1102EU3LEnFrGe.indbEn5 2012/06/2018:47:112012/06/2018:47:11

En 6
English
CAUTION
Never put aroma oil or other fragrances into the water tank.•
This could damage the ultrasonic humidifier or cause a breakdown.
Before moving the humidifier, first remove the water tank, and throw away the•
water inside the humidifier body.
Otherwise, the water in the water tank and humidifier body could spill.
When draining the water, be sure to drain it in the direction indicated by the arrow.•
Draining the water in a different direction may let water get into the fan outlet or overflow
drain and can result in malfunction.
Correct Use of the Ultrasonic Humidifier
Preparation Before Use
Place the humidifier on the aroma base.1.
Insert the braces on the aroma base all the way into the screw holes on the bottom
of the humidifier.
Humidifier
Aroma base
Place the humidifier on a level surface.2.
Place on a flat, stable surface.
CAUTION
Place the humidifier at least two meters from televisions, radios, and other electronics.
Otherwise, static interference can result.
Fill with water.3.
Remove the cap to the water tank and fill with clean, room temperature clean water.1
Firmly tighten the water tank cap, wipe up any spilled water, and check that no water is2
leaking.
03ALG-KW1102EU3LEnFrGe.indbEn603ALG-KW1102EU3LEnFrGe.indbEn6 2012/06/2018:47:112012/06/2018:47:11

En 7
English
Water tank back side
CAUTION
Only use clean water.•
If refilling the water after using the humidifier, water inside the mist cone will spill•
when removing the cone. Therefore, have towels on hand so the humidifier and
floor do not get wet.
Set the water tank into the humidifier so that it fits securely.4.
Line up the alignment points on the humidifier and the tank and put them together•
securely.
Align the tab on the inside of the humidifier with
the notch in the water tank and set the tank in place.
(The side opposite the handle when it is down is the
front)
Set the cover on the humidifier so that it fits securely.5.
Put the• cover securely onto the humidifier with the water tank already mounted.
03ALG-KW1102EU3LEnFrGe.indbEn703ALG-KW1102EU3LEnFrGe.indbEn7 2012/06/2018:47:112012/06/2018:47:11

En 8
English
The slant of the water tank and the slant of the cover ( ) go to
the front (facing the controls).
The straight surface ( ) goes to the back (where the cord is).
Line the cover up more or less and put it on, then adjust it by
turning it left or right until it fits just right.
Front (Controls)
WARNING
Do not use the humidifier with the power cord bundled up.•
Doing so may cause the cord to overheat and/or catch on fire.
If you are going out or will be away from the humidifier for a long time, unplug the•
power cord from the outlet.
Otherwise, you could forget to turn it off or a fire could result.
Plug the power cord into the outlet.6.
Keep the humidifier an appropriate distance from walls and
surrounding objects
Pay attention to the following points when using the humidifier.
At least 100 cm
above the humidifier
At least 50 cm in front
At least 50 cm
behind
At least 50 cm
to the left
At least 50 cm to
the right
Use the humidifier in a location that is at least 50 cm away from walls, bedding, curtains,•
furniture, and other objects.
03ALG-KW1102EU3LEnFrGe.indbEn803ALG-KW1102EU3LEnFrGe.indbEn8 2012/06/2018:47:122012/06/2018:47:12

En 9
English
Starting and Stopping Operation
CAUTION
When going to bed during the winter, if the heater is turned off and the room
temperature drops below 15°C, continued misting operation can result in
condensation.
Because this may get the product and the floor wet, if using in environments where the room
temperature is expected to drop below 15°C or the humidity is expected to be above 60%
when going to bed, either set misting to SL (Min.), or turn it off.
Water indicator
Power/Mist Setting button
Mist level indicator
Using the timer function:*
Press the Power/Mist Setting button and when it is set to SL (Min.), it activates the timer
function, which automatically turns the power off after five hours.
Starting operation1.
Pressing the Power/Mist Level button turns the Mist level indicator green and
misting begins.
After making sure the power plug is securely plugged in, start operating the
humidifier.
CAUTION
After setting the water tank on the humidifier, and pressing the Power/Mist Level
button to start misting, the Water indicator lamp will light for a few moments but
the unit will not start operating. Once water from the water tank crosses over to the
humidifier, the Water indicator lamp will go off and the unit will start to operate.
Stopping operation2.
Press the Power/Mist Level button and the Mist level indicator will go out and the
unit stops operating.
After misting stops, the fan runs for about one minute before the humidifier*
comes to a complete stop.
If the Water indicator turns red during operation
When the indicator is lit, this indicates that the water level in the tank is low.
When the water level in the water tank and water tub get low, the alarm makes a
sound with five beeps, and the Water indicator lamp lights up red.
After draining any water remaining in the water passage, refill the water tank with new1
water.
When water reaches the humidifier from the water tank, the Water indicator turns off.2
Press the Power/Mist Setting button to start operation.3
CAUTION
If water needs to be refilled, the alarm makes a sound with five beeps, and the Power/
Water indicator lights up red. Refill the water tank with water.
03ALG-KW1102EU3LEnFrGe.indbEn903ALG-KW1102EU3LEnFrGe.indbEn9 2012/06/2018:47:122012/06/2018:47:12

En 10
English
Using the Aroma Base
Pull out the felt case from the aroma base holding the humidifier .1.
Felt case
Soak the felt in the case with an aroma oil.2.
Check that felt is inserted in the felt case. Soak the felt with two or three drops of
aroma oil or essential oil (available commercially) while being careful that it does not
spill outside the case. Next, insert the felt case all the way inside the humidifier.
Aroma oil or essential oil
Place the felt under the tabs
so it does not stick up from
the indentation in the felt
case. If it sticks up, it could
get caught when inserting/
removing the felt case.
Tab
Felt
CAUTION
Do not insert too much aroma oil or essential oil so that it overflows from the felt•
case.
Always wipe up any aroma oil or essential oil if it spills outside the felt case of the•
aroma base.
Do not insert the aroma base while aroma oil or essential oil is spilt outside the felt•
case of the aroma base.
Do not soak aroma oil using a fabric other than the special felt specifically for this•
product.
This could result in malfunction or damage to the aroma base.
Starting operation3.
To start operation, follow the procedure for starting operation on page 8. Enjoy the
mist containing the aromatic fragrance.
If aroma oil is not added, it can be used as a regular humidifier.
Replacing the Felt
Replace the felt whenever it becomes dirty, or when using a different type of*
aroma oil or essential oil.
In addition to the felt already included with the aroma base at purchase, two*
additional pieces are also included.
The felt cannot be washed and used again.*
03ALG-KW1102EU3LEnFrGe.indbEn1003ALG-KW1102EU3LEnFrGe.indbEn10 2012/06/2018:47:122012/06/2018:47:12

En 11
English
Insert the felt so that it fits under the clips in the felt case.*
Tab
Felt
Wash the felt case with a neutral cleanser, and carefully wipe up any moisture*
before inserting it into the aroma base by following steps 1 and 2.
Handling of aroma oils and essential oils
Do not expose the oils to an open flame.•
Store in a location that is out of the reach of children.•
If oils are spilled on clothes or other objects, rinse with a lot of water and allow to•
air dry. Do not use a dryer. This could cause the object to ignite.
If any oil gets on your hands, wash them immediately.•
For further details about the handling of aroma oils and essential oils, refer to the•
supplied User’s Manual.
Cleaning and Storage
WARNING
After taking out the water tank, do not touch the metal parts inside the humidifier.•
Before cleaning always turn it off, unplug the cord from the outlet and drain the•
water out of the humidifier.
After cleaning, be sure to always remount the parts in their original locations.•
Cleaning the Ultrasonic Humidifier (at least twice a week)
Fully drain the water left inside the humidifier.
When draining the water, be sure to drain it in the direction of the arrow shown*
on the humidifier body.
Draining the water in a direction different from the direction of the arrow can
result in malfunction.
Drain the water, and dry thoroughly.*
Use a vacuum cleaner or other method to clean off the dust on the filter.*
Cleaning the Water Tank (at least twice a week)
Fill up the water tank with water, close the water tank cap, thoroughly
shake the water tank, and then drain. (Repeat this two or three times.)
Be sure to always wash the water tank with water at room temperature.*
Washing the water tank with hot water can cause it to deform. Do not wash with
cleansers or other solvents. These substances can cause the humidifier to deform.
CAUTION
Before using a cloth containing chemical substances, check its safety information.•
(Otherwise, discoloration or scratches could result.)
Replace the water in the water tank and water tub with new water everyday. Clean•
regularly to ensure that the inside of the product is always clean.
Only use clean water.•
Do not use distilled water.
To inhibit the growth of bacteria, we recommend to use water which underwent a chlorine
disinfection process. Also, soft water with less minerals suits this product.
03ALG-KW1102EU3LEnFrGe.indbEn1103ALG-KW1102EU3LEnFrGe.indbEn11 2012/06/2018:47:122012/06/2018:47:12

En 12
English
Never use juice or other drinking fluids, hot water (40°C or higher), or water mixed•
with chemical products, fragrances (such as aroma oil), or cleanser.
Before Requesting Repairs or Service
WARNING
This product can be disassembled and repaired by qualified repair technicians only.
If you find any problems, follow the troubleshooting procedures below.
Problem Primary cause Remedy
The power does
not turn on.
Is the power cord plugged•
into the outlet?
Plug the power cord into the outlet.
No mist is formed,
or the amount of
mist is small.
Is the Water indicator lit•
red?
Is it time (about 3,000•
hours) to replace the
ceramic disc (ultrasound
vibration plate)?
Fill with water.
If the service life of the ceramic disc
is exceeded, the amount of mist
generated can drop or fail to be
generated at all. Repairs are needed, so
consult with the Service Center.
The Water
indicator stays lit
in red even when
water is supplied.
Is the water tank loaded•
in the humidifier so that it
fits securely?
Load the water tank so that it fits
securely.
Even when its
operation is
stopped, it sounds
like it is operating.
This is not a malfunction.• After misting stops, the fan runs for
about one minute before the humidifier
comes to a complete stop.
A smell is emitted. Are you using water other•
than clean water?
Drain the water left in the water tank,
and clean by following the procedure in
“Cleaning and Storage”.
The mist nearly
stops once every
minute.
This is not a malfunction.• To prevent water from collecting at
the mist outlet, the fan motor stops
operation about once every minute,
and the fan stops for about two
seconds.
03ALG-KW1102EU3LEnFrGe.indbEn1203ALG-KW1102EU3LEnFrGe.indbEn12 2012/06/2018:47:122012/06/2018:47:12

En 13
English
Specifications
Product name Ultrasonic Humidifier
Model ALG-KW1102EU
Power supply 220 – 240 V ac, 50/60 Hz
Power
consumption Approx. 33 W
Humidification
Per hour on
H (High), 270 ml; on M (Medium), 170 ml; on L (Low), 110 ml;
on SL (Min.), 70 ml
Continuous
humidifying time Approx. 9 hrs (in High mode (H))
Tank capacity Approx. 2.5 L
Power cord length Approx. 1.8 m
Size 150 mm Dia. × 750 mm H.
Weight Approx. 1.8 kg
Accessories User’s Manual × 1, Aroma base (1 felt sheet provided in base) × 1,
Replacement felts × 2
Due to a continuous process of product improvement, the specifications and other*
information are subject to change without notice.
03ALG-KW1102EU3LEnFrGe.indbEn1303ALG-KW1102EU3LEnFrGe.indbEn13 2012/06/2018:47:122012/06/2018:47:12

English
Novis Electronics AG
Steigstrasse 2
8610 Uster-Suisse
www.novisgroup.ch
Tel: 0041 (0) 43 355 75 00
Email: sales@novisgroup.ch
6C12A
03ALG-KW1102EU3LEnFrGe.indbEn1403ALG-KW1102EU3LEnFrGe.indbEn14 2012/06/2018:47:122012/06/2018:47:12

ALG-KW1102EU
Français
Humidificateur à ultrasons
ALG-KW1102EU
Manuel d’utilisation
Nous vous remercions d’avoir fait l’acquisition de l’humidificateur
à ultrasons ALG-KW1102EU.
Lisez attentivement le présent Manuel d’utilisation afin de vous
familiariser avec la mise en œuvre correcte de l’appareil. Veuillez
conserver le manuel d’utilisation pour d’éventuelles consultations
ultérieures.
Novis Electronics AG
Imported and distributed by
03ALG-KW1102EU3LEnFrGe.indbFr103ALG-KW1102EU3LEnFrGe.indbFr1 2012/06/2018:47:132012/06/2018:47:13

Fr 2
Français
Informations de sécurité
Avant sa mise en œuvre, lisez attentivement les informations de sécurité de l’appareil•
afin de l’utiliser correctement. Conformez-vous toujours à ces informations quand vous
utiliserez ce produit.
ATTENTION DANGER
Ne démontez pas l’appareil. Ce produit ne peut être démonté que par
des réparateurs qualifiés.
Toute tentative de démontage de ce produit peut provoquer un incendie, une électrocution ou
des blessures. Contactez votre concessionnaire préalablement à toute demande de réparation.
N’utilisez pas l’appareil quand le cordon ou la prise d’alimentation
électrique est endommagé, ou quand la prise du cordon est lâche
dans la prise murale.
Il peut en découler une électrocution, un court-circuit ou un début d’incendie.
Ne pas rayer, endommager, modifier, incurver à l’excès, tirer, torsader
ou coller le cordon d’alimentation, ne pas le coincer sous des objets
lourds ni le fixer.
Ces opérations sont susceptibles d’endommager le cordon d’alimentation électrique et de
provoquer un incendie ou une électrocution.
N’insérez pas d’objets métalliques tels que fils et épingles, ou d’autres
objets étrangers dans les interstices de l’appareil.
Il peut en découler une électrocution ou un dysfonctionnement.
Ne laissez pas les enfants utiliser ce produit sans surveillance et tenez-
le hors de portée des très jeunes enfants.
A défaut, l’enfant s’expose à une brûlure, une blessure ou une électrocution.
Utilisez l’appareil uniquement avec la tension d’alimentation indiquée
(220 – 240 V CA).
Le non respect de cette précaution peut provoquer un incendie ou une défaillance.
ATTENTION
Pour votre sécurité, débranchez la prise murale de l’appareil avant de
le nettoyer.
N’utilisez pas l’appareil dans des locaux présentant un degré
d’humidité élevé (85% ou plus).
N’utilisez pas l’appareil à des emplacements où la vapeur serait en
contact direct avec les meubles, les murs, les rideaux, le plafond ou
autres objets.
03ALG-KW1102EU3LEnFrGe.indbFr203ALG-KW1102EU3LEnFrGe.indbFr2 2012/06/2018:47:132012/06/2018:47:13

Fr 3
Français
Ne placez pas l’appareil sur des surfaces inclinées, en hauteur
(bibliothèques) ou sur des surfaces instables.
N’obstruez pas la buse de brumisation.
Utilisez uniquement de l’eau claire.
N’utilisez pas d’eau chaude.
L’utilisation d’eau chaude à 40°C ou plus risque de provoquer une déformation ou un
dysfonctionnement du produit.
Ne versez jamais d’huile aromatique ou autres fragrances dans le
réservoir d’eau.
Ne posez pas l’appareil directement sur un tapis ou un autre objet
composé de fibres souples.
Ne nettoyez pas l’appareil avec du benzène ou un diluant.
Quand vous débranchez la prise du cordon d’alimentation, saisissez la
prise elle-même, ne tirez jamais sur le cordon.
Jetez l’eau quand l’appareil n’est pas utilisé.
Renouvelez quotidiennement l’eau contenue dans le réservoir et le
compartiment d’eau. Nettoyez régulièrement ces éléments afin de
conserver l’intérieur de l’appareil toujours propre.
Ne placez pas de téléphones portables, d’ordinateurs ou autres
appareils électroniques à proximité de l’humidificateur.
L’espace proche de l’humidificateur pouvant devenir très humide quand l’appareil fonctionne,
tenez l’appareil éloigné des téléphones portables, des ordinateurs ou autres appareils
électroniques sensibles à l’humidité.
Protégez l’appareil contre le gel.
Si l’appareil est placé dans un endroit sujet à de très basses températures, jetez l’eau qu’il
contient.
Placez l’appareil dans un endroit éloigné de deux mètres au minimum
des postes de télévisions, de radio et autres équipements
électroniques.
N’inclinez pas l’appareil.
Cet appareil n’est pas destiné à être utilisé par des personnes (incluant
les enfants) présentant des capacités physiques, sensorielles ou mentales
réduites ou manquant d’expériences et de connaissances, sauf si elles
font l’objet d’une supervision ou ont reçu des instructions concernant
l’utilisation de l’appareil par une personne responsable de leur sécurité.
03ALG-KW1102EU3LEnFrGe.indbFr303ALG-KW1102EU3LEnFrGe.indbFr3 2012/06/2018:47:132012/06/2018:47:13

Fr 4
Français
Les enfants doivent être surveillés afin de s’assurer qu’ils ne jouent pas
avec l’appareil.
Si le cordon d’alimentation électrique est endommagé, il doit être
remplacé par le fabricant ou des personnes possédant des
qualifications similaires afin d’écarter tout danger.
Procédure d’élimination réglementaire de ce produit.
Ce symbole signale que ce produit ne doit pas être jeté avec les autres
déchets domestiques dans les pays membres de l’UE. Afin d’éviter
toute nocivité pour l’environnement ou la santé humaine due à des
rejets de déchets incontrôlés, ce produit doit être recyclé de manière
responsable afin d’encourager la réutilisation durable des ressources
matérielles. Pour renvoyer un appareil usagé, veuillez utiliser les
procédures de retour et de collecte ou contactez le vendeur du
produit. Les commerçants peuvent collecter ce type de produit dans le
cadre du recyclage pour la protection de l’environnement.
03ALG-KW1102EU3LEnFrGe.indbFr403ALG-KW1102EU3LEnFrGe.indbFr4 2012/06/2018:47:132012/06/2018:47:13

Fr 5
Français
Désignations et fonctions des pièces
Capot
Poignée du réservoir d’eau
Elle est destinée à transporter le réservoir.
(La poignée est placée du côté opposé aux commandes.)
Réservoir d’eau
Orifice de brumisation
Cordon
d’alimentation
électrique
Sortie de ventilation
Humidificateur
Prise d’alimentation
électrique
Cavité de brumisation
Entrée d’air
03ALG-KW1102EU3LEnFrGe.indbFr503ALG-KW1102EU3LEnFrGe.indbFr5 2012/06/2018:47:132012/06/2018:47:13

Fr 6
Français
Intérieur du corps de l’appareil
Capteur de niveau d’eau
Flèche de direction de la purge d’eau
(Purger l’eau dans la direction indiquée
par la flèche)
Sortie de ventilation
Bac à eau
Plaque de vibration à ultrasons
Canalisation d’évacuation
Face arrière du réservoir d’eau
Cavité de brumisation
Bouchon du réservoir d’eau
ATTENTION
Veillez à ne pas verser d’eau dans la sortie de ventilation ou la canalisation
d’évacuation pendant la purge ou le nettoyage.
Il pourrait en résulter un dysfonctionnement.
Accessoires
Base aroma
Feutre de rechange × 2
03ALG-KW1102EU3LEnFrGe.indbFr603ALG-KW1102EU3LEnFrGe.indbFr6 2012/06/2018:47:132012/06/2018:47:13
Table of contents
Languages:
Other Allonge Humidifier manuals