Alphatron Marine AlphaFeverCamera User manual

AlphaFeverCamera
Network Turret Camera
alphatronmarine.com

AlphaFeverCamera Quick Start Guide
ii
Regulatory Information
FCC Information
FCC compliance: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmfulinterference.
2. This device must accept any interference received, including interference that may
cause undesiredoperation
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points.
For more information see: www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that cannot
be disposed of as unsorted municipal waste in the European Union. See the
product documentation for specific battery information. The battery is
marked with this symbol, which may in clude lettering to indicate cadmium
(Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to
your supplier or to a designated collection point. For more information see:
www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.

AlphaFeverCamera Quick Start Guide
iii
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to
avoid danger or property loss.
The precaution measure is divided into Warnings and Cautions:
Warnings: Neglecting any of the warnings may cause serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Warnings Follow these safeguards to
prevent serious injury or death.
Cautions Follow these precautions to prevent
potential injury or material damage.
Warnings
The device should be used in compliance with local laws and electrical safety
regulations. Refer to the appropriate documentation for detailed information.
The input voltage should conform to IEC60950-1 standard: SELV (Safety Extra Low
Voltage) and the Limited Power Source (12 VDC). Refer to the appropriate
documentation for detailed information.
DO NOT connect multiple devices to one power adapter, to avoid over-heating or fire
hazards caused byoverload.
Make sure the plug is properly connected to the power socket.
If smoke, odor, or noise arises from the device, immediately turn off thepower,
unplug the power cable, and contact the servicecenter.
The installer and user are responsible for password and security configuration and its
settings.
Both internal and external grounds should be connected properly. (The crosssection
area of the grounding wire must be no less than 4 mm2, and no less than that of the
phase connector).
Cautions
Do not drop the device or subject it to physical shock.
Wipe the device gently with a clean cloth and a small quantity of ethanol, if
necessary.
Do not aim the lens at the sunor any other bright light.

AlphaFeverCamera Quick Start Guide
iv
When any laser equipment is in use, make sure that the device lens is not exposed to
the laser beam, or it may burnout.
⚫Do not place the camera in extremely hot, cold (the working temperature shall be -
40 °C to 65 °C), dusty or damp locations, and do not expose it to high electromagnetic
radiation.
Place the device in a dry and well-ventilated environment.
Keep non-waterproof devices away from liquids.
Keep the device in original or similar packaging while transportingit.
A few device components (e.g., electrolytic capacitor) require regular replacement.
The average lifespan varies, so periodic checking is recommended. Contact your
dealer fordetails.
Improper use or replacement of the battery may result in explosion hazard. Replace
with the same or equivalent type only. Dispose of used batteries in conformance with
the instructions provided by the batterymanufacturer.
Never attempt to disassemble thedevice.

AlphaFeverCamera Quick Start Guide
v
Table of Contents
1
Preparation............................................................................................... 1
2
Appearance Description............................................................................ 2
2.1 Type I Turret Camera Appearance ........................................................................ 2
2.2 Type II Turret Camera Appearance ....................................................................... 2
2.3 Cable Descriptions................................................................................................ 3
2.4 Alarm In/Out Connections.................................................................................... 3
3
Install the Turret Camera........................................................................... 4
3.1 Monitor Distance Range....................................................................................... 4
3.2 Install Memory Card ............................................................................................. 5
3.3 Install Turret Camera ............................................................................................ 5
3.4 Install Network Cable Water-proof Jacket............................................................ 8
3.4.1 Install Network Cable Waterproof Jacket ...................................................... 8
3.4.2 Waterproof Other Cables ............................................................................... 9
4
Set the System over the LAN ................................................................... 10
4.1 Wiring................................................................................................................. 10
4.2 Activate the System............................................................................................ 10
4.2.1 Activation via Web Browser ......................................................................... 10
4.2.2 Activation via SADP Software....................................................................... 11
4.3 Modify the IP Address ........................................................................................ 12
5
Operate via Web browser ....................................................................... 14
5.1 Access the System.....................................................................................................14
5.2 Live View Page.................................................................................................... 15
6
Appendix................................................................................................. 17
6.1 Common Material Emissivity Reference............................................................. 17
6.2 Frequently Asked Questions (FAQ)..........................................................................18
6.2.1 Device Running Error ................................................................................... 18
6.2.2 Device Upgrading......................................................................................... 18
6.2.3 Others .......................................................................................................... 18

AlphaFeverCamera Quick Start Guide
1
1Preparation
Basic Requirement
All the electronic operation should be strictly compliance with the electrical safety
regulations, fire prevention regulations and other related regulations in your local
region.
Check the package contents and make sure that the device in the package is in
good condition and all the assembly parts areincluded.
Use the system according to the working environment requirement.
Check Installing Environment
Be sure that there is enough space to install the Turret Camera and accessories.
Make sure that the wall is strong enough to withstand at least 8 times the weight
of the system and themount.
Prepare Cables
According to the actual network bandwidth, the Cat5 (in 100M) or Cat6 (100M
above) isneeded.
⚫When the Turret Camera uses standard 12V DC power supply, the power cable
should be American wire gauge 18 or above. The formula of the cross-section S
(mm²) and the maximum transmission distance L (m) of the bare wire is L=50*S.
⚫Choose the video cable according to the transmission length. The video should
meet the least demands as: 75Ω resistance; 100% copper core conducting wire;
95% weaving coppershield.
Prepare Tools
Before installation, please prepare the tools needed, such as the expansion screws,
electric hammer, electric drill, wrench, screwdriver, electroprobe and network
cable.
Original Packaging
When you unpack the Turret Camera, please keep the original package properly, in
case of returning or repairing the Turret Camera, you can pack the Turret Camera
with the package.
Note: The user should be responsible for any damage caused when transporting
with unoriginal package.

AlphaFeverCamera Quick Start Guide
2
2Appearance Description
There are two types of thermal network turret cameras. Here are the overviews of Type
I camera and Type IIcamera.
2.1 Type I Turret Camera Appearance
Refer to the following figure for type I thermal turret camera overview.
Figure 2-1 Type I Thermal Turret Camera Overview
2.2 Type II Turret Camera Appearance
Refer to the following figure for type II thermal turret camera overview.
Figure 2-2 Type II Thermal Turret Camera Overview

AlphaFeverCamera Quick Start Guide
3
OUT(n)
+
DC
OUT(n)
-
Thermal Speed
Dome
Relay Output
2.3 Cable Descriptions
The cable interfaces of Turret Camera are shown in the figure below. The cables of
RS-485, power supply, alarm inputs, alarm outputs, etc. are distinguished by different
colors. Please refer to the labels attached on the cables for identification.
Audio Output Interface
Audio Input Interface
Alarm Interface
RS-485 Interface
Power Interface
Network Interface
Figure 2-3 Cables of Thermal Turret Camera
2.4 Alarm In/Out Connections
This section is only for the Turret Camera with alarm in/out functions.
The Turret Camera can be connected with alarm inputs (0~5VDC) and alarm outputs.
Refer to the following diagrams for alarm output:
DC Load
Diagram (left) Diagram (right)
Figure 2-4 Alarm Out Connections
The alarm provides the relay output (no voltage), and the external power supply is
required when it connects to the alarm device.
For DC power supply (left diagram), the input voltage must be no more than 30VDC,
1A.
For AC power supply, the external relay must be used (right diagram) to prevent
damages to the Turret Camera and avoid risk of electric shock.
Thermal speed
Dome
Relay Output
GND OUT
30VDC
1A
JQC-3FG
Relay
(10A 250VAC)
~
220V AC
OUT(n)
L
N
OUT(n)

AlphaFeverCamera Quick Start Guide
4
3Install the Turret Camera
Before you start:
1. Check the package contents and make sure that the device in the package is in good
condition and all the assembly parts are included.
2. Please turn off the power of the Turret Camera before connecting the cables.
Notes:
⚫Do not drag the Turret Camera with its waterproof cables, or the waterproof
performance isaffected.
⚫Please remove the protective film on the Turret after the installation.
⚫Do not touch the bubble of the lower Turret directly. The image blurs otherwise.
3.1 Monitor Distance Range
Electric lens is adopted for the thermal channel of Turret Camera. It supports auto-focus
function and remote focus function. For different lens focal length, the monitoring range
is shown in the table below:
Table 3-1 Monitor Range (Pixel Interval: 17um)
Lens Focal Length/mm
1.8
3.1
6.2
MRAD
9.44
5.48
2.83
Detection Range (Vehicle)/m
162
280
559
Detection Range (Human)/m
53
91
182
Recognition Range (Vehicle)/m
41
70
140
Recognition Range (Human)/m
13
23
46
Identification Range (Vehicle)/m
20
35
70
Identification Range (Human)/m
7
11
23
Notes:
⚫This table is for reference only, and the actual detection range may vary according to
different camera settings, mounting condition, monitor and so on.
⚫When the weather is fine and the atmospheric visibility is normal, the probability of
detecting/recognizing/identifying target is50%.
⚫The human width is presumed as 0.5m (human width cannot exceed 0.75m), the
human height is presumed as 1.8m, and the vehicle width cannot exceed 2.3m.

AlphaFeverCamera Quick Start Guide
5
3.2 Install Memory Card
The micro SD card of two camera models is installed in the same way. Here is an
example of SD card installation for type II camera.
Steps:
1. Remove the cover on the back of the TurretCamera.
Figure 3-1 Remove the Cover
2. Insert the SD card to the SD card slot and install the cover back.
Figure 3-2 SD Card Slot
3.3 Install Turret Camera
Two types of cameras are installed in the same way. Here is an example of installation
for type II camera.
Steps:
1. Drill the hole on the wall or the celling according to the supplied drill template

AlphaFeverCamera Quick Start Guide
6
Figure 3-3 Drill Template
2. Turn the ring anticlockwise and remove it.
Note: The ring is only applicable to type II camera.
Figure 3-4 Remove the Ring
3. Loosen the screw and dismount the camera body from the base.
Figure 3-5 Dismount the Camera from Base
4. Mount the camera base according to the position of drill template.

AlphaFeverCamera Quick Start Guide
7
Drill
Template
Figure 3-6 Mount the Camera Base
5. Mount the Turret body to the base. Rotate the camera body in the pan direction
(0°~360°) or rotate the lens in the tilt direction (0°~80°) to get the desired view angle.
0-360°
0-80°
Figure 3-7 Mount the Camera Body
6. Screw the screw to fix the camera body on the camera base.
Figure 3-8 Screw the Camera
7. Mount the ring on the camera body, and turn it clockwise to fix thering.
Note: The ring is only applicable to type II camera.

AlphaFeverCamera Quick Start Guide
8
Figure 3-9 Mount the Ring
3.4 Install Network Cable Water-proof Jacket
Purpose:
If the camera is installed outdoor, you should use the waterproof accessory or
tapes to waterproof the cables. Otherwise the cables might get wet or a short
circuit occurs.
3.4.1 Install Network Cable Waterproof Jacket
①②③④⑤⑥
Steps:
Figure 3-10 Install Waterproof Jacket
1.
Feed the network cable through ① and ③ inorder.
2.
Fix ② on the network cable between ① and ③.
3.
Place ⑤onto the end of ⑥, and plug the RJ45 male connector into RJ45
female connector.
4.
Screw ③ to ⑥clockwise.
5.
Push ② into ③.
Align
③
④
⑥
①

AlphaFeverCamera Quick Start Guide
9
6.
Secure ① with the ③ in clockwise direction.
3.4.2 Waterproof Other Cables
After routing and connecting the cables, use the waterproof tapes to wrap up
the cables. Connected cables and spare cables both should be wrapped up as
the figuresbelow.
Figure 3-11 Waterproof Cables

AlphaFeverCamera Quick Start Guide
10
4Set the System over the LAN
Notes:
⚫You shall acknowledge that the use of the product with Internet access might be
under network security risks. For avoidance of any network attacks and
information leakage, please strengthen your own protection. If the product does
not work properly, please contact with your dealer or the nearest service center.
⚫To ensure the network security of the Turret Camera, we recommend you to have
the system assessed and maintained termly. Youcan contact us if you need such
service.
4.1 Wiring
To view and configure the system via LAN (Local Area Network), you need to connect the
network system in the same subnet with your PC. Then, install the SADP or client
software to search and change the IP of network system.
The following figure shows the cable connection of network system.
Figure 4-1 Wiring over LAN
4.2 Activate the System
Purpose:
You are required to activate the system first by setting a strong password for it before
you can use the system.
Activation via Web Browser, Activation via SADP, and Activation via client software are
supported. In the following sections, activation via web browser and SADP will be taken
as examples. You may refer to the user manual of the system for the details of activation
via client software.
4.2.1 Activation via Web Browser
Steps:
1.Power on the system, and connect the system to the network.
PC
Network
Speed Dome
Switch
Internet
NVR

AlphaFeverCamera Quick Start Guide
11
2.Input the IP address into the address bar of the web browser, and click Enter to enter
the activationinterface.
Note: The default IP address of the system is 192.168.1.64.
Figure 4-2 Activation Interface(Web)
3. Create a password and input the password into the password field.
4. Confirm thepassword.
5. Click OK to activate the system and enter the live view interface.
4.2.2 Activation via SADP Software
SADP software is used for detecting the online device, activating the device, and
resetting the password.
Get the SADP software from the supplied disk or the official website, and install the
SADP according to the prompts. Follow the steps to activate the system.
Steps:
1.Run the SADP software to search the online devices.
2. Check the device status from the device list, and select an inactive device.
STRONG PASSWORD RECOMMENDED–We highly recommend you create a
strong password of your own choosing (using a minimum of 8 characters,
including upper case letters, lower case letters, numbers, and special
characters) in order to increase the security of your product. And we
recommend you reset your password regularly, especially in the high security
system, resetting the password monthly or weekly can better protect your
product.

AlphaFeverCamera Quick Start Guide
12
Figure 4-3 SADP Interface
3.Create a password and input the password in the password field, and confirm the
password.
4. Click OK to save the password.
You can check whether the activation is completed on the popup window. If activation
failed, please make sure that the password meets the requirement and then try again.
4.3 Modify the IP Address
Purpose:
Toview and configure the system via LAN (Local Area Network), you need to connect the
network system in the same subnet with your PC. Then, install the SADP software or
client software to search and change the IP of network system. We will take modifying
the IP Address via SADP software as an example to introduce the IP address
modification.
Steps:
1. Run the SADPsoftware.
2. Click to select an activedevice.
Note: Please refer to section 3.2 to activate the system if it is inactive.
STRONG PASSWORD RECOMMENDED–We highly recommend you create a
strong password of your own choosing (using a minimum of 8 characters,
including upper case letters, lower case letters, numbers, and special
characters) in order to increase the security of your product. And we
recommend you reset your password regularly, especially in the high security
system, resetting the password monthly or weekly can better protect your
product.
Select inactive device.
Input and confirm
password.

AlphaFeverCamera Quick Start Guide
13
3. Change the device IP address to the same subnet with your computer by either
modifying the IP address manually or checking the checkbox of Enable DHCP.
Figure 4-4 Modify the IP Address
4. Input the password and click Save to activate your IP address modification.

AlphaFeverCamera Quick Start Guide
14
5Operate via Web browser
5.1 Access the System
System Requirement:
Operating System: Microsoft Windows XP SP1 and above version / Vista / Win7 /
Server 2003 / Server 2008 32bits
CPU: Intel Pentium IV 3.0 GHz or higher
RAM: 1G or higher
Display: 1024×768 resolution or higher
Web Browser: Internet Explorer 7.0 and above version, Apple Safari 5.02 and above
version, Mozilla Firefox 5 and above version and Google Chrome8 and above version
Steps:
1. Open the web browser.
2. In the browser address bar, input the IP address of the network Turret Camera, e.g.,
192.168.1.64 and press the Enter key to enter the login interface.
3. Activate the Turret Camera for the first time using, refer to the section 4.2 Activate
the System.
4. Input the user name and password and click .
The admin user should configure the device accounts and user/operator
permissions properly. Delete the unnecessary accounts and user/operator
permissions.
Note:
The device IP address gets locked if the admin user performs 7 failed password
attempts (5 attempts for the user/operator).
Figure 5-1 Login Interface
5. Install the plug-in before viewing the live video and managing the network Turret
Camera. Please follow the installation prompts to install the plug-in.

AlphaFeverCamera Quick Start Guide
15
Note:
You may have to close the web browser to finish the installation of the plug-in.
Figure 5-2 Download Plug-in
6. Reopen the web browser after the installation of the plug-in and repeat the above
steps 2-4 to login.
Note:
For detailed instructions of further configuration, please refer to the user
manual of network Turret Camera.
5.2 Live View Page
The live video page allows you to view live video, capture images, realize PTZ control,
set/call presets and configure video parameters.
Table of contents
Other Alphatron Marine Security Camera manuals
Popular Security Camera manuals by other brands

Bosch
Bosch FlexiDomeXF VDC-485V03-20 installation instructions

Amax Digitec
Amax Digitec Network Camera user manual

COP Security
COP Security 15-CD66WIB user manual

Everet
Everet EVP412N user manual

ENFORCER
ENFORCER EV-2726-N3GQ manual

EverFocus
EverFocus EQ350HQ User's manual and operation instructions