Aquagarden 1450 User manual

Established over 50 years ago, Blagdon are
committed to producing a comprehensive range
of high quality, easy to use, pond equipment.
An ongoing programme of research and
development ensures excellent performance
and value for all their customers. This product
excellence is demonstrated by Blagdon’s award
winning range of water gardening equipment.
As a result Blagdon’s reputation for quality is
unrivalled amongst experienced pond gardeners
and retailers alike.
Blagdon - The Pond Masters
The name you can rely on
www.aquagarden-range.co.uk
Interpet, Vincent Lane,
Dorking, Surrey, RH4 3YX
Leaflet Code: 01/12/11
FOUR IN ONE,
PUMP, FILTER
WITH UVC
1450/3250
Produced exclusively by

Congratulations on buying a
Aquarden Four in one.
Manufactured with advanced technology to
create a clean and healthy pond for your fish.
IMPORTANT
Please attach proof of purchase to this manual
and file in a safe place.
CONTENTS
Getting to know your Four-in-One 1450
Parts Descriptions / spares codes - with exploded diagram
Getting to know your Four-in-One 3250
Parts Descriptions / spares codes - with exploded diagram
Pump performance / flow chart
Specification chart
Installation
Electrical Installation
Installing Inpond
Installing UVC
UVC Electrical Installation
Maintenance and cleaning
Cleaning
Step by Step guides
Routine Maintenance
Annual Maintenance
Winter storage
Troubleshooting
Troubleshooting and maximise performance
Faults - problem procedure
Consumer advice contact details
Guarantee
2
2,3 & 4
5
5, 6 & 7
8
8
9
9
10, 11, 12,& 13
16 - 17
18 - 19
14 - 15, 20 - 21
14 - 15
20
14
21
21
22
22, 23 & 24
24
25
24 & 25
1
FOUR IN ONE,
PUMP, FILTER
WITH UVC
1450/3250

GETTING TO KNOW YOUR FOUR-IN-ONE 1450 GETTING TO KNOW YOUR FOUR-IN-ONE 1450
No. Part Description Spare Code
1. Locking Handle N/A
2. Filter Lid N/A
3. Coarse Foam 1051170
4. Medium Foam 1051170
5. Polymer Wool Cartridge N/A
6. Polymer Wool Pad 1051166
7. UVC Viewing Window N/A
8. UVC Contact Chamber Screws N/A
9. UVC Magnet N/A
10. Ceramic Media 1051187
11. Filter Body N/A
12. IPX7 Starter UVC N/A
13. UVC Mains Cable N/A
14. UVC Electronics & Cap N/A
15. UVC Body N/A
16. UVC Quartz Sleeve Yellow Lock Cap N/A
17. UVC O ring N/A
18. UVC Quartz sleeve Holder N/A
19. PL 5w UVC Lamp 1041041
20. 5w Quartz Sleeve N/A
21. Outlet Locking Nut N/A
22. Double threaded attachment N/A
23. 1 1/2" Connecting Pipe N/A
24. Pump Locking Nut N/A
25. 1 1/2" Impellor Cover N/A
26. O ring N/A
27. Impellor Complete 1017800
28. Pump motor unit N/A
29. Low Voltage Transformer N/A
30. Pump Cable Low Voltage N/A
31. Light Level Sensor - Photo Sensor N/A
32. Optional Sensor Cover N/A
33. Automatic LED Spot Light Body N/A
34. Automatic LED Spot Light O ring N/A
35. LED Lamp 0.76w 1051330
36. LED Lamp cover clear N/A
37. LED Lamp Screw Cap N/A
1
2
3
4
5
6
7
8
53
12
9 21
10
11
13 22 23 24 25 26 27 28 30
14 15 16 17 18 19 20
44
43
48
49
47 46 45
50
44
52
51
50
49
47 46 45
44
43
54 29
42
37
36
35
34
33
32
41
40
39
38
31
32

43
42
41
40
39
GETTING TO KNOW YOUR FOUR-IN-ONE 1450 GETTING TO KNOW YOUR FOUR-IN-ONE 3250
No. Part Description Spare Code
38. Ball Joint Connector N/A
39. Ball Joint N/A
40. Ball Joint O ring N/A
41. Extension Pipe Connector N/A
42. 30cm Telescopic Extension pipe N/A
43. Control Valve & Diverter N/A
44. Screw on hosetails 1/2" 12.5mm N/A
45. Daisy 1017763
46. Super Daisy 1017763
47. Water Bell Large 1017763
48. New Fountain Adapter N/A
49. Complete Ball Joint N/A
50. Screw on hosetails 1/2" 12.5mm N/A
51. 1/2" 12.5mm Silicon Hose; not included N/A
52. 1/2" 12.5mm Control Valve hose attachment N/A
53. UVC Contact Chamber N/A
54. 20cm Extension Pipe N/A
1
2
3
4
5
6
7
8
9
12
10
11
13
14
15 17 16 18 19 20 21 22 23
24 25 26 27 28 29
53 54 52 50 51
49
55
56
53 54 52 51 50
49
48
47
46
45
30
44
38
37
31
36
35
34
33
32
2nd way of connection
54

GETTING TO KNOW YOUR FOUR-IN-ONE 3250 GETTING TO KNOW YOUR FOUR-IN-ONE 3250
No. Part Description Spare Code
1. Locking Handle N/A
2. Filter Lid N/A
3. Coarse Foam 1051774
4. Medium Foam 1051774
5. Polymer Wool Cartridge N/A
6. Polymer Wool Pad 1051166
7. UVC Viewing Window N/A
8. UVC Contact Chamber Screws N/A
9. UVC Contact Chamber N/A
10. UVC Magnet N/A
11. Ceramic Media 1051187
12. IPX7 Starter UVC N/A
13. UVC Mains Cable N/A
14. Filter Body N/A
15. UVC Electronics & Cap N/A
16. UVC O ring N/A
17. UVC Body N/A
18. UVC Quartz Sleeve Yellow Lock Cap N/A
19. UVC Quartz sleeve O ring N/A
20. UVC Quartz sleeve Holder N/A
21. PL 9w UVC Lamp N/A
22. Lamp Rubber Holder N/A
23. 9w Quartz Sleeve N/A
24. 1 1/2" Connecting Pipe N/A
25. Pump Locking Nut N/A
26. 1 1/2" Impellor Cover N/A
27. Pump O ring N/A
28. Impellor Complete 1051781
29. Pump motor unit N/A
30. Low Voltage Transformer N/A
31. Pump Cable Low Voltage N/A
32. Light Level Sensor - Photo Sensor N/A
33. Optional Sensor Cover N/A
34. Automatic LED Spot Light Body N/A
35. Automatic LED Spot Light O ring N/A
36. LED Lamp 0.76w 1051330
37. LED Lamp cover clear N/A
No. Part Description Spare Code
38. LED Lamp Screw Cap N/A
39. 18.75mm (3/4") Hose Fitting N/A
40. 25mm (1") Hose Fitting N/A
41. 12.5mm (1/2") Hose Fitting N/A
42. T-piece N/A
43. T-piece Connector N/A
44. Ball Joint N/A
45. Ball Joint O ring N/A
46. Extension Pipe Connector N/A
47. 30cm Telescopic Extension pipe N/A
48. 20cm Extension pipe N/A
49. Jet Housing N/A
50. Bell Jet N/A
51. Tulip Jet N/A
52. Daisy jet N/A
53. Triple Jet N/A
54. Jet Housing N/A
55. Fountain adapter N/A
56. Complete Ball Joint N/A
76

“The power supply must meet the specification of the product.
Four-in-One Pump
The cores in the supply cable are coloured in accordance with the following code:
Brown = Live, Blue = Neutral.
The electric cable is permanently connected and sealed in the motor body.
If the supply cable is damaged the pump must not be used.
Do not use the supply cable to lift the pump as this may cause damage.
For permanent installations to the mains supply, it is necessary to conform to the
regulations of the local electricity authority and this would include the use of a metal or
plastic conduit to protect the cable.
Attention has been drawn to the fact that special rules may exist concerning the installation
of your pond pump (i.e. local building regulations).
These pumps must not be used in swimming pools, or areas where people are in contact
with the water.
Always disconnect the mains electricity supply whilst the equipment is being installed,
repaired, maintained or handled. Consult a qualified electrician if in any doubt about
wiring this product to the main supply.
GETTING TO KNOW YOUR FOUR-IN-ONE INSTALLATION
Pump performance / flow chart
1450 3250
Voltage 12v 12v
Watts 10 26.5
Safety Rating IP68 IP68
Maximum Depth 1.25 M 1.5M
Maximum Lift 1.25M 1.3M
Lift Flow Rates
1.25 metres 200
1.0 metres 300 870
0.5 metres 520 1250
0.0 metres 770 1650
Flow is given at optimum rate
Pump 1450 3250
Max Flow 770 1650
Max Head 1.25m 1.3m
Low Voltage 12V 12V
Weatherproof
transformer
IP56 IP56
Mains Cable 1.5m 1.5m
Low Voltage
Cable
10m 10m
Watts 10w 25.5w
LED
Photo sensor
activated
0.76w 0.76w
UVC 1450 3250
Lamp 5w 9w
Cable 10m 10m
Voltage 230v 230v
Hertz 50Hz 50Hz
Safety Rating IPX7 IPX7
Wattage 12 12
Specification chart
Tech Specification:
WARNING - All Four-in-One models must be used with an
RCD
A Residual Current Device (RCD), also know as the Residual Current Circuit
Breaker (RCCB), with a tripping current not exceeding 30mA must be nstalled in the
supply circuit.
A means of disconnection from the supply having a contact separationof at least 3mm in
Filter
Model
Max pond size
filtered over 75cm
/ 2’6” average
depth shaded Pond in full
sunlight
Shallow pond - un-
der 75cm / 2’6”
average depth
Pond in full
sunlight and
shallow
Pond with Koi
full sunlight and
shallow
UVC
Model
watts
Recommended
Hose Size
Outlet
1450 1450ltr/320gal 1088ltr/240gal 1088ltr/240gal 815ltr/180gal 408ltr/89.8gal 5W 12.5mm 1/2”
3250 3250ltr/716gal 2438ltr/537gal 2438ltr/537gal 1828ltr/403gal 914ltr/204gal 9W 19mm 3/4”
98
Warning - The Four-in-One pump is provided with a thermal cut out that
temporarily switches off the pump in case of overheating and the pump may
automatically restart.

INSTALLATION INSTALLATION
Locating your Four-in-One
The Inpond pump and filter should be located on a firm and level basein the pond/water
feature in a depth of at least 10cm, but no more than 1.25m for the 1450 model and 1.5m
for the 3250 model.
Fountain
Make sure there is ample cable from the transformer. Place product in desired location.
Using the telescopic pipe adjust so the fountain head is above the surface of the pond.
Fountain height can now be adjusted, see ‘Adjusting flow control’ diagram below. See
‘’Getting to know your Four-in-One’’ for parts and descriptions.
Tip: Ensure that any fountain or feature fitted does not empty water out of pond/water feature.
Adjusting Flow Control
Turn clockwise to increase anti-
clockwise to reduce flow.
The flow control
valve is fitted with
a diverter to ensure
there is always
pond circulation.
Four-in-One 1450 Four-in-One 3250
Adjust bell by moving head higher
for small bell and lower for a
wider bell shape.
Convenient Installation
Four-in-One 1450 & 3250
Four-in-One 3250 Only
FOUNTAIN
MIN: 40cm
MAX: 70cm
WATER FEATURE
HOSE
FOUNTAIN OPTION
FOUR IN ONE
FEATURE OPTION
OR
FOUR-IN-ONE
PUMP
FOUNTAIN
MIN: 40cm
MAX: 70cm
FOUR-IN-ONE FOUNTAIN AND/OR FEATURE OPTION
WATER
FEATURE
HOSE
Bell Fountain
Adjusting Dual Control T Piece and telescopic riser pipe
1. Adjust height by unlocking collar then pushing or
pulling 30cm telescopic riser pipe. Optional additional
20cm extensions can be added to increase the height.
2. Outlet Flow Control Valve
Supply water features, waterfalls and filters by adding
1” 3/4” 1/2” fittings and hose. Adjust flow by turning
flow control valve.
3. Fountain Flow Control Valve
Adjust fountain jet flow by turning flow control valve.
4. Fountain Ball Joint
Adjust the collar of the ball joint to enable
the extensions to be moved compensating
for an uneven pond floor.
1
2
3
4
1110
FOUR IN ONE

20cm
extension
pipe
30cm adjustable
tetescopic
extension pipe
Fully adjustable
flow control for
water feature
Fully adjustable
fountain control.
Adjusts fountain
height and width.
Interchangeable 1”/25mm,
3
/
4”/19mm, 1
/
2” 12.5mm
hose fittings
20° +/- ball joint
adjustment to
compensate for
uneven pond floor
Water
Feature
Hose
LED Spotlight
INSTALLATION INSTALLATION
Waterfall Installation
Important
The outlet hose should be smooth bore (not corrugated) pipe installed over as short a
distance as possible with no kinks or bends.
Connecting Outlet Hoses
The recommended hose size for your
Four-in-One Filter is stated in the filter
performance and specification chart.
On Page 8
Always secure with a Jubilee clip
Warming the hose in a bucket of
boiling water can aid fitting.
Use the shortest possible hose
lengths to minimise flow restrictions.
Avoid folds and kinks in the hose,
which will reduce flow and filter
performance.
Installing the waterfall
or feature
1450 3250
Four-in-One1450
FOUR-IN-ONE RUNS A FOUNTAIN OR FEATURE AND LED SPOTLIGHT
Four-in-One 3250
FOUR-IN-ONE FILTER RUNS A FOUNTAIN, FEATURE AND LED SPOTLIGHT
1312
To feature
or waterfall

MAINTENANCE & CLEANING
IMPORTANT - Failure to carry out routine maintenance leaving the pump
under reduced or no flow conditions for long periods will result in a shorter
pump life and will invalidate the guarantee.
The Aquagarden Four-in-One pump is centrifugal with a magnetic impellor movement driven
by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning
of the impellor is necessary.
Routine Maintenance
1. Switch off electricity
2. Remove Four-inOne from pond using carry handle (do not use the cables to lift
the Inpond)
Automatic
LED Spotlight
Saving time and money
Pump
Low voltage running
Ceramic Biomedia
Supports large populations
of friendly bacteria, creating
a clear and healthy pond
Green Water UV Clarifier
Built in light guarantees
algae free clear water
Course/Medium Foam
Open cell foam in two
reducing grades catching
dead algae, dirt and waste
giving a crystal clear pond.
Locking Handle
Doubles as a carry
handle for easy
removal from pond
Polymer Wool
Pad Cartridge
Polishes the water
quickly removing
particles that
create cloudiness
Inlet Grills
High surface area, ideal
for general pond use
How it works - Flow detail
The water flows through the top of the filter cage down through
the filter foams and ceramic media then through the UV chamber
ready to exit via the pump.
Safety Switch
Built in automatic magnetic
safety OFF switch for the UV
1. Handle in the locked position 2. Handle is in the central position. This will enable the filter
and pump to be carried in and out of the pond. *Ensure the
filter is not carried by the pump cable.
4. The handle is in the unlocked position allowing the filter
media to be removed and cleaned.
3. Close handle down to open position
MAINTENANCE & CLEANING
Opening and locking filter handle
Easy lift integrated locking handle
Foams may be cleaned vigorously in a bucket of pond water.
Adding Blagdon Bio Start after filter maintenance will help replenish these beneficial
bacterial populations and is highly recommended during the first two months of operation
when the filter is slowly being colonised.
Ceramic bio media
These will only need very occasional cleaning (once per year), but must be rinsed in pond
water to prevent damaging the beneficial bacteria which help maintain a healthy pond.
1514

UVC INSTALLATION
UVC Lamps & quartz sleeve maintenance
The UVC lamp must be replaced every six months / once a season. It is recommended that
the lamp is replaced in the spring.
The Quartz sleeve can become coated in lime scale build up in hard water areas. This
should be carefully removed from the quartz sleeve and cleaned with a soft cloth.
A wet test must be carried out after maintenance to ensure there are no leaks before the
UVC is reconnected. pond/water feature.
Wet testing the UVC
Testing/replacing the UVC lamp
See Page 17 for illustration
1. Unlock the green UVC electronics cap.
2. Inspect the UVC cap and Quartz sleeve for water leaks.
3. Then unlock the yellow quartz sleeve end cap and unplug the lamp to replace if
desired
Warning - 1) Always turn off the power before any maintenance to the UVC
section 2) Always view the UVC lamp through the viewing window on the UVC
Chamber 3) Direct exposure to UVC light can damage your eyes and skin.
Caution - Four-in-One has been fitted with a magnetic safety switch. 1) Do not
remove unit with power turned on 2) Do not place near strong magnetic fields.
IMPORTANT - A wet test of the UVC under operating conditions must be carried
out before the UVC or electrical supply is installed. Connect the UVC to the Four-in-One
following all installation instructions. After running for 24 hours check for leaks.
IMPORTANT - Ensure that the mains supply is switched off and the power is isolated
before removing the UVC cover.
UVC INSTALLATION
4. If there are no signs of leakage reverse the procedure ensuring that the quartz sleeve
O-ring is in place. See alignment diagram.
5. Ensure the yellow quartz sleeve cap and the green UVC electronics cap are firmly ser
cured by making sure the two looked positions are in direct line of each other. See
diagram on page 18, section 5.
6. The unit is protected by a magnetic safety switch that prevents the UVC light from
illuminating when the cover is removed even if the power is on.
7. In order to check that the UVC lamp is operating see page 23 on how to view your
UVC lamp.
1716
If there has been any damage to the unit please return to the point of purchase for inspection.
1
2
4
32

UVC ELECTRICAL INSTALLATION UVC ELECTRICAL INSTALLATION
Warning - Direct exposure to UVC light can damage your eyes and skin.
Electrical installation - UVC
Inpond UVC
The cores in the supply cable are coloured in accordance with the following
code: Brown = Live, Blue = Neutral. Green / Yellow = Earth
In accordance with EN60335-2-109:2010
Warning - A Residual Current Device (RCD), also known as the Residual
Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA
must be installed in the supply circuit. A means of disconnection from the supply
having a contact separation of at least 3mm in all poles must be incorporated
in the wiring
Important: Please note all electrical work on garden lighting and power installations must
comply with part P of the building regulations. Failure to comply is a criminal offence. If the
installation of this product is not carried out by a competent electrician who is registered
under the Part P self-certification scheme then you must notify the local building control
department before work begins. For further information and guidance on this matter and
other electrical installations in your home that might be covered by the relevant legislation,
contact your local authorities building control department.
For permanent installations to the mains supply, it is necessary to conform to the regulations
of the local electricity authority and this would include the use of a metal or plastic conduit to
protect the cable.
Attention has been drawn to the fact that special rules may exist concerning the installation of
your pond UVC (i.e. local building regulations).
This UVC must not be used in swimming pools, or areas where people are in contact with the
water.
Always disconnect the mains electricity supply whilst the equipment is being installed, repaired,
maintained or handled. Consult a qualified electrician if in any doubt about wiring this product
to the mains supply.
WARNING: Electrical Safety
UVC warning: Dangerous Ultra Violet Radiation. The rays from the UVC lamp
are harmful to eyes and skin.
Always turn off UVC electrical supply before any maintenance.
To protect the UVC starter; never immerse in water. Locate the UVC starter
(Four-in-One1450 part 12 & Four-in-One 3250 part 11) 1 metre minimum from
pond edge.
ALIGN ARROWS
1918
5

Polymer wool cartridge
The polymer wool pad may be washed a limited number of times before it starts to lose
efficiency and block rapidly.
Replacement packs of polymer wool are availible from your retailer and are quick and easy
to replace.
See page 15 On how to remove the cartridge easiliy from the Four-in-One.
MAINTENANCE & CLEANING MAINTENANCE & CLEANING
Active hinge
Polymer wool pad
Polymer wool cartridge
Removing led Lamp
Replacing or removing the lamp
can be easiliy done by unscrewing
the lamp screw cap, then the clear
cover can come apart. Allowing the
LED lamp to be disconnected. See
getting to know your Four-in-One for
part descriptions.
IMPORTANT - Ensure that the mains supply is switched off and the power isolated
before removing the lamp cover.
Pump
LED Automatic Photo Sensor
- detects when light levels are low/dusk
Annual maintenance of the filter
Check for wear. Once a year you should dismantle your Four-in-One. Dismantle the filter
examining all the parts for wear or damage, replacing any parts showing obvious signs
of wear and/or damage (see getting to know your filter for replacement codes and parts
descriptions on pages 2, 3, 4 & 5)
Annual maintenance of the pump
Check for wear. Once a year you should service your pump. Dismantle pump and examine
all parts for wear or damage, replacing any parts that show obvious wear and/or damage
(see getting to know your Four-in-One for parts/description and replacement codes). Particu-
lar care should be taken to examine the cable entry points.
Annual maintenance of the UVC
Check for wear. Once a year you should dismantle your Four-in-One UVC section. Ensure
you have disconnected the mains supply before carrying out any maintenance or cleaning.
Dismantle the UVC containing all the parts for wear and damage, replacing any parts that
show obvious signs of wear and damage (see getting to know your Four-in-One for parts/
description and replacement codes).
Winter Storage
The Four-in-One can be run in the pond during the winter but care should be taken to ensure
that it is fully immersed and cannot freeze solid. If the Four-in-One is not used during the
winter follow the annual maintenance procedure and store frost-free in the house or garage
until spring.
The LED automatic sensor is positioned
on top of the motor body between the
outlet and the lamp. Ensure this is kept
clean from dirt and algae as it needs
sufficent light to activate correctly.
This extremely effcient lamp uses less
than 1 watt of electricity which
automatically turns on at dusk and off at dawn.
Automatic LED spot light
Ball joint
LED automatic sensor
Pump
If the LED light is not required
you can permentently remove the lamp.
Inpond comes complete with a rubber
cover that can be used to keep the LED
light on permenantly.
See instruction sticker on the pump for more information.
2120

TROUBLESHOOTING TROUBLESHOOTING
Four-in-One Filter
Cloudy/brown water
• The flow rate / pond turnover is to high or to low. Check that you have correctly
calculated the pond volume and that pump flow rate is within limits.
• The filter is not being supplied with water 24 hours a day. Do not turn off your
Four-in- One. Continuous running is needed to maintain a clean and healthy pond.
• The filter foam pads are insufficiently blocked to trap the fine waste. Treat with Blagdon
Clear Pond treatment.
• The water is extremely dirty, remove pond waste and leaves - carry out a partial water
change.
• Filter is incorrectly sized - refer to filter performance and specification chart.
• The filter foams have not been positioned or replaced correctly, ensure that the foams fit
tightly within the filter chamber.
UVC leaks
• Check that the UVC O-ring has been correctly assembled.
• Check that the UVC cap is correctly locked with the yellow quartz sleeve section.
Arrows on both caps should be correctly aligned when fitted. See page 16 & 17 on
how to correctly install and remove UVC section.
Four-in-One Pump
Problem
Low flow from pump
1. Follow routine cleaning procedure if no improvement.
2. Follow monthly cleaning procedure.
3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed or kinked.
4. Keep the height that water is to be pumped from the water surface (called Head) to a
minimum. The higher the head the lower the flow rate and the more wear on the pump.
5. Use the largest diameter, smoothest bore pond hose over the shortest
distance and keep hose fittings to a minimum. This removes frictional loss
of flow and so increases pump flow rates.
Poor Fountain performance
• Reduced height.
• Jets blocked.
Clean flow adjusters and fountain
head. Wash under a tap or hose.
Pond Pump Cleaner should be used
to remove lime scale build-up/waste
(see diagram) for improved results.
No flow from pump
1. Check power supply is on.
2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION).
3. Follow low flow procedure as above.
If none of the above works contact Interpet (Blagdon) Consumer Advice Department
(See Faults problem procedure Page 25).
Green water
• Settlement test the water to ensure that there is no sediment suspended in the water. If
there is, follow the brown cloudy water troubleshooting guide.
• In order to check that the UVC lamp is operating: Open the filter unit (see page 15)
remove the filter foams and cartridge. Positioned on top of the yellow UVC contact
chamber will be a round viewing window where you should see a faint blue light.
This operation may need to be carried out at dusk as UVC lamps emit a dim blue light
under normal operation. Turning the lamp on and off may aid visual identification.
(Ensure the UVC lamp is not more than 6 months old).
• The UVC may be working effectively but the filter foam/media is too clean and is
unable to remove the fine coagulated waste. Treat the pond with Clear Pond and do
not clean the foams/media until they are blocked.
• The filter is too small for the pond, check your filter selection chart.
• The UVC quartz sleeve is dirty or coated in lime scale. Gently remove the quartz sleeve
and clean.
• Follow all cloudy water trouble shooting points.
DAISY
To clean, remove head
and rinse.
Or in hard water
areas, use Pond Pump Cleaner
2322

TROUBLESHOOTING & IMPORTANT IMPORTANT
PUMP & LIGHT
This product is guaranteed against defects in material and workmanship for 2 years from date
of purchase, under normal usage. This guarantee DOES NOT APPLY in case of improper
us, negligence, lack of maintenace or accidental damage either to the pump or the impeller
shaft. If the pump fails due to a manufacturing fault within this period it will be either repaired or
replaced free of charge. Liability is limited to replacement of the faulty product only, no other
costs will be reimbursed. The guarantee is not transferable and does not affect your statutory
rights. This guarantee does not confer any rights other than those expressly set out above.
Excludes the pump impellor & LED lamp which may require replacing annually. If any parts
need replacing, spares are availible from your retailer.
You can help protect the environment.
Please remember to respect the local regulations: hand in the non-working
electrical equipments to an appropriate waste disposal centre.
Clearwater Guarantee
The Clearwater guarantee will be honoured for 1 year after proof of purchase.
Clearwater is guaranteed to a depth of 1m, so that fish are clearly visible.
Clearwater is guaranteed provided:
• You follow all instructions as above.
• Your filter is within the performance guidelines stated.
• You consult the Consumer Advice Email and follow any advice to correct the situation.
See details below. Refunds can only be authorised by Interpet Blagdon.
Consumer Advice contact details
Interpet (Blagdon) Consumer Advice Department
Vincent Lane, Dorking, Surrey RH4 3YX
E-mail: customercar[email protected]
www.aquagarden-range.co.uk
UVC light not illuminated
• Check all fuses / RCD and electrical connections follow electrical installation
Faults - Problem Procedure
Before returning your Four-in-One to your dealer or contacting our Consumer Advice
Department, please carry out the following steps. This will solve most problems quickly
and easily.
1. Ensure electrical procedures have been followed fully. Check fuses and any cable
connectors/switch boxes.
2. (a) Follow routine maintenance procedure fully. (b) Check location and connecting your
pump details including flow rates. (c) Ensure that your pond volume and pump flow rate
meet the maximum pond size recommended for the filter model on the filter
performance and specification chart. (d) Follow troubleshooting guide.
3. If there is a mechanical breakdown of the filter or UVC, return to the point of purchase
for inspection and advice (You will need proof of purchase).
Guarantee
UV & FILTER
This product is guaranteed against defects in material and workmanship for 2 years from the
date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper
use, negligence, lack of maintenace or accidental damage to either the filter or UVC. If the
filter or UVC fails due to a manufacturing fault within this period it will be either repaired or
replaced free of charge. Liability is limited to replacement of the faulty product only; no other
costs will be reimbursed. The guarantee is not transferable and does not affect your statutory
rights. This guarantee does not confer any rights other than those expressly set out above. This
guarantee does not cover the filter foams or UVC bulb, which will need replacing when worn
or every 6 months. If any parts are needed, spares are availible from your retailer.
2524
This manual suits for next models
1
Table of contents
Other Aquagarden Water Pump manuals
Popular Water Pump manuals by other brands

Grundfos
Grundfos 2000 Series Installation and operating instructions

Monzana
Monzana DBDW003 instructions

Milton Roy
Milton Roy Roytronic A Series instruction manual

Emerson
Emerson Klauke AHP 700-L instruction manual

Ingersoll-Rand
Ingersoll-Rand ARO EVO EP10 Series Operator's manual

Calpeda
Calpeda SPA Original operating instructions