INSTALLATION AND START-UP INFORMATION
Optimum performance of the pump is dependant upon the entire liquid system and will be obtained
only with the proper selection, installation of plumbing for the pump and accessories.
PLUNGER PUMP SERVICE MANUAL
SPECIFICATIONS: Maximum specifications refer to individual attributes and
may have qualifications. It is not implied that any maximums can be
performed concurrently. If more then one maximum is considered, check
with your Arimitsu Pumps supplier of Arimitsu of N.A. to confirm the proper
performance, environment, system design and pump selection. Refer to the
respective Product Data Sheet (PDS) for complete specification, parts lists,
performance charts and exploded view.
LUBRICATION: Fill crankcase with Arimitsu pump oil (p/n 30103) to required
level. DO NOT RUN PUMP WITHOUT OIL IN CRANKCASE. Change oil
according to the following schedule; after the first 30 hours, then every
500 hours or once per year which ever comes first. Additional lubrication
may be required with increased hours of operation, temperature, and
various environments.
PUMP ROTATION: Pump was designed for forward rotation, unless
otherwise noted by a directional arrow. If rotating counter to arrow,
additional oil should be added to aid lubrication. Fill to slightly above the
upper line on dipstick to assure adequate lubrication.
PULLEY SELECTION: Select size of motor pulley required to deliver the
desired flow. Be careful to choose a pulley with the proper horsepower
capacity. Horsepower requirement can be found on PDS for each respective
model. Use formula found on formulas page as a guide to pulley selection.
Note: Use the same pitch size pulleys for both pump and motor.
DRIVE SELECTION:The motor or engine driving the pump must be of
sufficient horsepower to maintain full RPM when the pump is at the desired
load. Select the electric motor from the Horsepower chart according to
required pump discharge flow, maximum pressure at the pump and drive
losses of approximately 5%. Consult the manufacturer of gas or diesel
engine for selection of the proper engine size. Use formula found on
formulas page as a guide for HP calculation.
The quotient will indicate the minimum HP size of motor to select. Please
choose a HP size larger when possible to allow for system inefficiencies such
as line loss and plumbing irregularities.
MOUNTING:
Choose a level horizontal surface that will allow access for maintenance and
visual inspection.The surface must be able to withstand vibration and be
strong enough to support the pump.
Use flexible hose for inlet and discharge connections on the pump to
minimize possible system stresses. Never connect rigid pipe to the inlet of
discharge of the pump.
Make sure the pump crankshaft and motor crankshaft are parallel and
mounted pulleys are in the straight line. Misalignment will lead to a loss of
performance and premature belt failure, in addition to damaging the pump
and/or motor.
• Choose a properly-rated belt for the HP of the system.Tighten to the
specifications recommended by the belt manufacturer. Do not over
tighten. Hand rotate pump pulley prior to starting to verify shaft and
bearings are free moving.
• Protect pump from humidity, dirt, heat, water spray and chemical
exposure.
PLUMBING:
INLET: When done correctly, inlet plumbing will positively benefit the
system. If you have any questions, please contact Arimitsu Pumps.
• DO NOT STARVE PUMP OR RUN DRY
• As a minimum requirement, use a hose one size larger than the inlet
port size.
• The pump will work best with a pressurized inlet that does not exceed
the maximum recommended on the specification sheet.
• Every pump is designed for suction lift (vacuum) inlet conditions,
however optimum performance is obtained with a pressurized inlet.
In cases such as hot or thick liquids, or high speed a positive inlet is
recommended.
• Several long-term failures result from improperly plumbed inlet
systems such as, valve breakage, manifold washout, seal failure,
noise, vibration, and plunger pitting.
• Pumps are not designed to run dry.
• Temperatures above 120°F are permissible. Add 1 PSI inlet pressure
per each degree F over 120°F. Elastomer or RPM changes may be
required in addition to pressure adjustment.
DISCHARGE:The fluid must have a place to go. All pumps MUST have
hydraulic flow control devices.
• Install a properly sized and functioning flow control device such as
an unloader valve or pressure regulator that will allow pumped fluid
to be diverted in case nozzles become plugged or trigger is
disengaged.
• Do not use metering valves or ball valves as primary flow control devices.
• DO NOT use a regulating device with selectable pressure greater than
pump rating.
• Open all valves prior to starting system to avoid deadhead
overpressure condition and severe damage to the pump or system.
• Install a pulsation dampener, pulse hose or accumulator, on the
discharge head or in the discharge line as close to the head as
possible. Be certain the pulsation dampener is properly sized for the
system pressure and flow.
• A reliable pressure gauge should be installed near the discharge outlet
of the high-pressure manifold.This is extremely important for
adjusting pressure regulating devices and also for proper sizing of the
nozzle or restricting orifice.The pump is rated for a maximum
pressure; this is the pressure at the discharge manifold of the pump,
not anywhere else in the pressure line.
• Use PTFE thread tape or pipe thread sealant to connect accessories
or plumbing.
MAINTENANCE:
Check: Inspect all system accessories and connections prior to start-up.
• Oil quality and level. Add oil if it is low and change if the oil looks old
or milky. (Arimitsu Oil p/n 30103)
• For leaks from manifold and crankcase. Change seals as necessary or
according to scheduled service intervals.
• Clean inlet filter or strainer as needed.
• Verify nozzles are not worn or damages. Nozzles create the pressure,
so a worn nozzle will result in lower performance. Worn or damaged
hoses must be replaced before use.
• Verify unloaders/regulators are adjustable and appear in good condition.
• Inspect hoses and connections for damage.
• Inspect belts for signs of wear or damage.
• Inspect trigger guns and other control valves.
Arimitsu of North America, Inc.
700 McKinley St. NW
Anoka, MN 55303
ph: 763.433.0303 • fax: 763.433.0404
arimitsupumps.com
5 Series
Visit arimitsupumps.com for distributor information

SERVICING THE FLUID END
1. Loosen (do not remove) outer bolts (6mm) of Manifold
Assembly.These 8 bolts will be removed later for valve
inspection. Remove center 4 bolts (6mm).
2. Gently pull Manifold Assembly away from crankcase. Be
careful to pull straight to avoid damaging Plungers. Rotation
of Crankshaft may aid in separating Manifold Assembly from
Crankcase Assembly.
3. Lay Manifold Assembly on work surface and remove 8 outer
bolts. Manifold Assembly should separate easily to allow
access to Valve Assemblies. Inspect Manifold O-Rings for
damage and replace if necessary. [Note: For Valve Service
continue to Step 4, for Seal Service skip to Step 7.]
4. Inlet Valves are larger than Outlet Valves for 508 & 511. Model
516 Valves are the same. Grasp Valve Cage with pliers and
gently rock and pivot until Valve comes free.
5. Examine Valves for damage such as pitting, gouging, or
broken parts. If damaged, replace with parts referenced in
the kit reference chart on page 3.
6. Install Valve Assemblies according to type and hole size.
Valve Gasket can be fit around and pushed after Valve
Assembly has been installed. Be careful not to roll Valve
Gasket edge over during installation. Valve Gasket should
be flat without bulges around Valve Seat.
7. Examine Plungers for cracks or surface damage. Replace
Plunger and Gasket if damaged as follows:
a. Remove Plunger Bolt (mm), Gasket and Plunger
Support.
b. Inspect and clean Support.
c. Place new Gasket on Plunger Bolt, then New Plunger,
and finally Support. Note: Support end of Plunger has
an identifying mark or dot.
d. Install assembly into Connecting Rod end and torque
to 5 ft. lbs.
[Note; For Seal Service continue with Step 8.To complete
Valve service skip to Step 13.]
8. Remove Seal Retainer, V packing, Spreader and Wave Washer
from ported manifold. Inserting a plastic driver in the wave
washer area may aid the process. Inspect seal bore for
damage and clean if necessary.
9. The Vacuum Seal can be removed from the inside of Seal
Retainer with a plastic driver, to avoid scratching surface.
Inspect for damage. Complete Seal Service with parts
referenced in the kit reference chart on page 3.
Seal Service follow steps 1 – 3, & 7 - 19

Valve Service follow steps 1 – 7, & 13 - 19
TORQUE CHART
Torque
Pump Item Thread Tool Size (P/N) in lbs ft. lbs. Nm
3 Series Valve Plug 22mm 24mm Hex 475 40 53.9
Manifold Bolts 8mm 6mm Allen 215 18 24.5
Connecting Rod 6mm 10mm Hex 95 8 10.8
Plunger Retainer 5mm 4mm Allen 60 5 6.9
5 Series Manifold Bolts 8mm 6mm Allen 215 18 24.5
Connecting Rod 6mm 10mm Hex 95 8 10.8
Plunger Retainer 5mm 4mm Allen 60 5 6.9
7 Series Outer Manifold Bolts 8mm 6mm Allen 215 18 24.5
Inner Manifold Bolts 10mm 8mm Allen 475 40 53.9
Connecting Rod 6mm 10mm Hex 95 8 10.8
Plunger Retainer 5mm 4mm Allen 60 5 6.9
11 Series Manifold Nuts 12mm 19mm Hex 695 55 78.5
Connecting Rod 8mm 13mm Hex 215 18 24.5
Plunger Retainer 5mm 4mm Allen 60 5 6.9
10. Insert Wave Washer, Spreader, V packing, (and back-up ring
for Model 516) into Seal Chamber of manifold.The Vacuum
Seal can be installed by squeezing and fitting into inside
groove of Seal Retainer. Be sure to install Vacuum Seal with
“u” of seal facing towards V packing.
11. Replace O-Ring (included in Seal Kit) around outside of
Seal Retainer.
12. Lightly lubricate seal bore and insert Seal Retainer. Even
force will allow Seal Retainer to slide into position.
13. Place Manifolds together. Manifold Dowel Pins will guide the
2 Manifolds together. Note:To insure Manifold O-Ring
remains in position during servicing, re-install and hold in
place with grease.
14. Replace 8 outer bolts and tighten finger tight.
15. Lightly lubricate Plungers and carefully slide Manifold
Assembly over Plungers until it contacts Crankcase
Assembly.
16. Replace center 4 bolts and torque to specifications listed in
torque chart below. Note: Bolts should be tightened following
the standard practice of an X pattern around Manifold
Assembly.
17. After the center 4 bolts are torqued, tighten 8 outer bolts to
torque to specifications listed in torque chart below. Use
standard practice of X pattern for these bolts as well.
18. Crankshaft should turn with minimal effort by hand when
service is complete. Check/add crankcase oil to proper level
on dipstick before operation. Arimitsu oil (PN30103).
Pump Inlet Outlet Seal
Model Kit Kit Kit
508 30111 30112 30110
511 30111 30112 30120
516 30101 30101 30100
KIT REFERENCE CHART
(model 508 & 511) (model 516)

MAINTENANCE AND SERVICE TIPS
INLET PRESSURE should fall within the specifications of the pump.
o Optimum pump performance is obtained with +15 PSI (1 BAR) inlet pressure.
o With adequate inlet plumbing, most pumps will perform with flooded suction.
Maximum inlet pressure is 75 PSI (5 BAR).
o After prolonged storage, pump should be rotated by hand and purged of air to
facilitate priming.
o Disconnect the discharge port and allow liquid to pass through pump and
measure flow.
INLET ACCESSORIES are offered to protect against over pressurization,
contamination or temperature and control flow.
o A shut-off valve is recommended to facilitate maintenance.
o Inspect and clean inlet filters on a regular schedule to avoid flow restriction.
o All accessories should be sized to avoid restricting the inlet flow.
o All accessories should be compatible with the solution being pumped to
prevent premature failure or malfunction.
o A gauge between filter and pump will indicate pump inlet pressure. Avoid
negative pressure (vacuum) inlet conditions.
BY-PASS TO INLET Care should be exercised when deciding the method of by-pass
from control valves.
o It is recommended the bypass be directed to a baffled reservoir tank, as
described above.
o Although not recommended, bypass liquid may be returned to the inlet line of
the pump. With a pressurized inlet system only, a thermo relief valve should be
used in the by-pass line to monitor the temperature build-up in the by-pass
loop to avoid premature seal failure.
o A reinforced flexible, low-pressure hose rated up to 300 PSI should be used for
bypass flow back to inlet.
o Caution should be exercised not to under size the bypass hose diameter
and length.
o Check the pressure in the bypass line to avoid over pressurizing the inlet.
o The by-pass should be connected to the pump inlet line with a constant
downward slope.
INLET SUPPLY should exceed the maximum flow being delivered by the pump to
assure proper performance.
o Open inlet shut-off valve and turn on water supply to avoid starving pump.
DO NOT RUN PUMP DRY.
o Temperatures above 120°F are permissible. Add 1 PSI inlet pressure per each
degree F over 120°F. Seal material or RPM changes may be required.
o Avoid closed loop systems especially with high temperature fluid or large
flows.The type of unloader or regulator can vary the effects of closed
loop bypass.
o Higher viscosity, thicker liquids require a positive head (0+ PSI) and RPM
changes may be required. Horsepower requirements may increase.
o When using a supply tank, size it to provide an adequate supply of water and
enough volume to decrease turbulence created from bypass return stream.
Generally, a minimum of 5 times the GPM although several system factors can
affect this. Provide adequate baffling in the tank to eliminate air bubbles and
turbulence; install diffusers on all return lines to the tank. Do not locate supply
ports next to bypass return ports.
o Supply tanks should be located above pump inlet with inlet lines plumbed from
the bottom of the tank.
o Tank fed, suction systems should have a constant downward slope into
pump inlet.
o Make sure adequate filtration exists to prevent debris from damaging pump.
INLET SIZE should be adequate to avoid starving the pump.
o Line size must be a minimum of one common size larger than the pump inlet
fitting. Avoid tees, 90-degree elbows or valves in the inlet line of the pump to
reduce the risk of flow restriction and cavitation.
o The line must be a FLEXIBLE reinforced hose, NOT a rigid pipe. Soft hose can
decrease system vibration.
o All systems should use a minimum of fittings and turns.
o Use an approved pipe sealant or tape to assure airtight, positive sealing of
all connections.
PREVENTATIVE MAINTENANCE CHECK-LIST
Check Daily Weekly 50 hrs. 500 hrs.* 1500 hrs.** 3000 hrs.**
Clean Filters X
Oil Level/Quality X
Oil Leaks X
Water Leaks X
Belts/Pulley X
Plumbing X
Initial Oil Change X
Oil Change X
Seal Change X
Valve Change X
Accessories X
* If other than Arimitsu oil is used, change cycle would be every 300 hours
** Each system’s maintenance cycle will be exclusive. If system performance
decreases, check immediately. If no wear at 1500 hours, check again at 2000
hours and each 500 until wear is observed. Valves typically require changing
every other seal change. Duty cycle, temperature, quality of pumped liquid
and inlet feed conditions all effect the life of pump wear part and
service cycle.
** Remember to service the regulator/unloader at each seal servicing and check
all system accessories and connections before resuming operation.
SERVICE INTERVALS:
• Change Oil (PN30103) every 500 hours.
• Change high-pressure and low-pressure seals every 1500 hours.
• Change valves every 3000 hours.
SERVICE TIPS:
• When pumping harsh chemicals, flush out chemical residue
immediately after use. Do not leave chemicals inside pump.
If it is not water or anti-freeze, flush from pump before storage.
• If the pump is used in areas or times of freezing, pump it dry
or leave anti-freeze in at time of storage.
• Use case and maintenance to prolong the life of the equipment.
INLET CONDITION CHECK-LIST

HOSE FRICTION LOSS
RESISTANCE OF VALVES AND FITTINGS
Water
Flow
GPM 1/4 5/16 3/8 1/2 5/8 3/4 1”
0.5 16 5 2
1 54 20 7 2
2 180 60 25 6 2
3 380 120 50 13 4 2
4 220 90 24 7 3
5 320 130 34 10 4
6 220 52 16 7 1
8 300 80 25 10 2
10 450 120 38 14 3
15 900 250 80 30 7
20 1600 400 121 50 12
25 650 200 76 19
30 250 96 24
40 410 162 42
50 600 235 62
60 370 93
PRESSURE DROP IN PSI PER 100 FT OF HOSE
WITH TYPICAL WATER FLOW RATES
Hose inside diameters, inches
Nominal
Pipe Inside 180˚ Tee Tee
Size Diameter Gate Globe Angle 45˚ 90˚ Close Thru Thru
Inches Inches Valve Valve Valve Elbow Elbow Ret Run Branch
1/2 0.622 0.41 18.5 9.3 0.78 1.67 3.71 0.93 3.33
3/4 0.824 0.54 24.5 12.3 1.03 2.21 4.90 1.23 4.41
1 1.049 0.69 31.2 15.6 1.31 2.81 6.25 1.56 5.62
1-1/4 1.380 0.90 41.0 20.5 1.73 3.70 8.22 2.06 7.40
1-1/2 1.610 1.05 48.0 24.0 2.15 4.31 9.59 2.4 8.63
2 2.067 1.35 61.5 30.8 2.59 5.55 12.30 3.08 11.6
2-1/2 2.469 1.62 73.5 36.8 3.09 6.61 14.70 3.68 13.20
3 3.068 2.01 91.5 45.8 3.84 8.23 18.20 4.57 16.40
4 4.026 2.64 120.0 60.0 5.03 10.80 23.90 6.00 21.6
Arriving at a total line pressure loss, consideration should then be given to pressure
loss created by valves, fitting and elevation of lines.
If a sufficient number of valve and fitting are incorporated in the system to materially
affect the total line loss, add to the total line length, the equivalent length of line of
each valve or fitting.
Equivalent Length of Standard Pipe in Feet
HELPFUL FORMULAS AND REFERENCE CHARTS
Determining
Pump RPM
Determining
Required HP
Determining
Motor Pulley Size
Rated GPM
Rated RPM
“Desired” GPM
“Desired” RPM
=
GPM x PSI
1460
Electric Brake
H.P. Required
=
Motor Pulley OD
Pump RPM
Pump Pulley OD
Motor RPM
=
NOZZLE VOLUME (GPM) AT VARIOUS PRESSURES (PSI)
Nozzle Orifice 100 500 800 1000 1200 1500 2000 4000
Size Dia. PSI PSI PSI PSI PSI PSI PSI PSI
2 .034 .32 .71 .89 1.00 1.10 1.22 1.41 2.00
2.5 .039 .40 .88 1.12 1.25 1.37 1.53 1.77 2.50
3 .043 .47 1.06 1.34 1.50 1.67 1.84 2.12 3.00
3.5 .048 .55 1.24 1.57 1.75 1.92 2.14 2.47 3.50
4 .052 .63 1.41 1.79 2.00 2.19 2.45 2.83 4.00
4.5 .055 .71 1.59 2.01 2.25 2.46 2.76 3.18 4.50
5 .057 .79 1.77 2.24 2.50 2.74 3.06 3.54 5.00
5.5 0.60 .87 1.94 2.46 2.75 3.01 3.37 3.89 5.50
6 .062 .95 2.12 2.68 3.00 3.29 3.67 4.24 6.00
6.5 .064 1.03 2.30 2.91 3.25 3.56 3.98 4.60 6.50
7 .067 1.11 2.47 3.13 3.50 3.83 4.29 4.95 7.00
7.5 .070 1.19 2.65 3.35 3.75 4.11 4.59 5.30 7.50
8 .072 1.26 2.83 3.58 4.00 4.38 4.90 5.66 8.00
8.5 0.74 1.34 3.01 3.80 4.25 4.66 5.21 6.01 8.50
9 .076 1.42 3.18 4.02 4.50 4.93 5.51 6.36 9.00
9.5 0.78 1.50 3.36 4.25 4.75 5.20 5.82 6.72 9.50
10 0.80 1.58 3.54 4.47 5.00 5.48 3.12 7.07 10.00
11 0.83 1.74 3.89 4.92 5.50 6.02 6.74 7.78 11.00
12 0.87 1.90 4.24 5.37 6.00 6.57 7.35 8.49 12.00
12.5 .089 1.98 4.42 5.59 6.25 6.85 7.65 8.84 12.5
13 .091 2.06 4.60 5.81 6.50 7.12 7.96 9.19 13.00
14 .093 2.21 4.95 6.26 7.00 7.67 8.57 9.90 14.00
15 .096 2.37 5.30 6.71 7.50 8.22 9.19 10.61 15.00
20 .109 3.16 7.07 8.94 10.00 10.95 12.25 14.14 20.00
25 .125 3.95 8.84 11.18 12.50 13.69 15.31 17.68 25.00
30 .141 4.74 10.61 13.42 15.00 16.43 18.37 21.12 30.00
40 .156 6.32 14.14 17.89 20.00 21.91 24.49 28.28 40.00
50 .172 7.91 17.68 22.36 25.00 27.39 30.62 35.36 50.00
60 .188 9.49 21.21 28.83 30.00 32.86 36.74 42.43 60.00
NOZZLE COVERAGE CHART
Included
Spray
Angle 2” 4” 6” 8” 10” 12” 15” 18” 24”
5˚ 0.2 0.4 0.5 0.7 0.9 1.1 1.3 1.6 2.1
10˚ 0.4 0.7 1.1 1.4 1.8 2.1 2.6 3.1 4.2
15˚ 0.5 1.1 1.6 2.1 2.6 3.2 3.9 4.7 6.3
20˚ 0.7 1.4 2.1 2.8 3.5 4.2 5.3 6.4 8.5
25˚ 0.9 1.8 2.7 3.5 4.4 5.3 6.6 8.0 10.6
30˚ 1.1 2.1 3.2 4.3 6.4 5.4 8.1 9.7 12.8
35˚ 1.3 2.5 3.8 5.0 6.3 7.6 9.5 11.3 15.5
40˚ 1.5 2.9 4.4 5.8 7.3 8.7 10.9 13.1 17.5
45˚ 1.7 3.3 5.0 6.6 8.3 9.9 12.4 14.9 19.9
50˚ 1.9 3.7 5.6 7.5 9.3 11.2 14.0 16.8 22.4
55˚ 2.1 4.2 6.3 8.3 10.3 12.5 15.6 18.7 25.0
60˚ 2.3 4.6 6.9 9.2 11.5 13.8 17.3 20.6 27.7
65˚ 2.5 5.1 7.6 10.2 12.7 15.3 19.2 22.9 30.5
70˚ 2.8 5.6 8.4 11.2 14.0 16.8 21.0 25.2 33.6
75˚ 3.1 6.1 9.2 12.3 15.3 18.4 23.0 27.6 36.8
80˚ 3.4 6.7 10.1 13.4 16.8 20.2 25.2 30.3 40.3
85˚ 3.7 7.3 11.0 14.7 18.3 22.0 27.5 33.0 44.0
90˚ 4.0 8.0 12.0 16.0 20.0 24.0 30.0 36.0 48.0
95˚ 4.4 8.7 13.1 17.5 21.8 26.2 32.8 39.3 52.4
100˚ 4.8 9.5 14.3 19.1 23.8 28.6 35.8 43.0 57.2
110˚ 5.7 11.4 17.1 22.8 28.5 34.3 42.8 51.4 68.5
120˚ 6.9 13.9 20.8 27.7 34.6 41.6 52.0 62.4 83.2
130˚ 8.6 17.2 25.7 34.3 42.9 51.5 64.4 77.3 103
140˚ 10.9 21.9 32.9 43.8 54.8 65.7 82.2 98.6
150˚ 14.9 29.8 44.7 59.6 74.5 89.5 112
160˚ 22.7 45.4 68.0 90.6 113
170˚ 45.8 91.6
THEORETICAL COVERAGE AT VARIOUS DISTANCES
FROM NOZZLE ORIFICE
GPM
Nozzle
( )
2
4000
PSI
PSI
4000
4000
NOZZLE FORMULAS
Nozzle# = GPM x
GPM = Nozzle # x
PSI = x
SPRAY
ANGLE
THEORETICAL
COVERAGE
SPRAY
DISTANCE
SPRAY ANGLE

Several elements make up a complete, functioning pumping system. All of these elements need to be operating correctly in order for the whole system to
function. Some of the elements include: duty-cycle, liquid being pumped, operating conditions and specifications versus the ratings and capabilities of the
pump and accessories. Proper care and maintenance of pump and system components will maximize the life of your equipment. Review and follow
recommendations regarding system design and inlet conditions to avoid potential problems.
Arimitsu Pumps are designed to offer superior life and be easy to service. Field servicing can be accomplished with standard tools. Use the following table as a
guide to determine cause and remedy for possible problems. Contact Arimitsu Pumps directly via web site or telephone for further assistance.
PROBLEM PROBABLE CAUSE SOLUTION
Low pressure • Worn nozzle. • Replace with properly sized nozzle.
• Belt slippage. • Tighten belt(s) or install new belt(s).
• Air leak in inlet plumbing. • Tighten fittings and hoses. Use PTFE liquid or tape.
• Pressure gauge inoperative or not registering accurately. • Check with new gauge. Replace worn or damaged gauge.
• Relief valve stuck, partially plugged or improperly adjusted. • Clean/adjust relief valve. Replace worn seats/valves and o-rings.
• Inlet suction strainer (filter) clogged or improperly sized. • Clean filter. Use adequate size filter. Check more frequently.
• Abrasives in pumped liquid. • Install proper filter.
• Leaky discharge hose or spray gun. • Replace discharge hose with proper rating for system.
• Inadequate liquid supply. • Check & clean filters.
• Severe cavitation. • Check inlet conditions.
• Worn Seals. • Install new seal kit. Increase frequency of service.
• Worn or dirty inlet/discharge valves. • Clean inlet/discharge valves or install new valve kit.
Pulsation • Faulty Pulsation Dampener. • Check precharge. If low, recharge, or install new dampener or pulse hose.
• Foreign material trapped in inlet/discharge valves. • Clean inlet/discharge valves or install new valve kit.
Water leak
•Under the manifold • Worn V-Packings, Hi-Pressure or Lo-Pressure Seals. • Install new seal kit. Increase frequency of service.
•Into the crankcase • Humid air condensing into water inside the crankcase. • Change oil every 3 months or 500 hours.
• Excessive wear to seals and V-Packings. • Install new seal kit. Increase frequency of service. Check inlet &
water conditions
Knocking noise
•Inlet supply • Inadequate inlet liquid supply. • Check liquid supply. Increase line size, pressurize, or dual feed.
•Pulley • Loose pulley on crankshaft • Check key and tighten set screw.
Recommended Oil Service Intervals: After first 30 hours, every 500 hours thereafter.
Oil leak
•Crankcase oil seals • Worn crankcase oil seals. • Replace crankcase oil seals.
•Crankshaft oil seals and o-rings • Worn crankshaft oil seals or o-rings on bearing cover. • Remove bearing cover and replace o-rings and/or oil seals.
•Drain plug • Loose drain plug or worn drain plug o-ring. • Tighten drain plug or replace o-ring.
•Rear cover • Loose rear cover or worn rear cover gasket. • Tighten rear cover or replace gasket.
•Filler cap • Excessive oil in crankcase. • Fill crankcase to specified capacity, do not overfill.
Pump runs extremely rough
•Inlet conditions • Restricted inlet or air entering the inlet plumbing. • Correct inlet size plumbing. Check for loose connections. Clean filters.
•Pump valves • Stuck inlet/discharge valves. • Clean out foreign material or install new valve kit.
•Pump seals • Leaking V-Packings, Hi-Pressure or Lo-Pressure seals. • Install new seal kit. Increase frequency of service.
Premature seal failure • Scored plungers. • Replace plungers, check inlet conditions.
• Over pressure to inlet manifold. • Reduce inlet pressure per specifications.
• Abrasive material in the liquid being pumped. • Install proper filtration at pump inlet and clean regularly.
• Excessive pressure and/or temperature of pumped liquid. • Check pressure and inlet liquid temperature.
• Running pump dry. • DO NOT RUN PUMP WITHOUT LIQUID.
• Starving pump of adequate liquid. • Increase hose one size larger than inlet port size. Pressurize and
dual feed.
DIAGNOSIS AND MAINTENANCE
This manual suits for next models
3
Table of contents
Popular Water Pump manuals by other brands

Wilo
Wilo Stratos ECO Series Installation and operating instructions

Bestway
Bestway P3042 owner's manual

Pearl
Pearl CQPL Installation and operating instructions

ITT
ITT Bornemann SLH-4U operating instructions

Quincy Compressor
Quincy Compressor QSV 205 instruction manual

Pfeiffer Vacuum
Pfeiffer Vacuum DUO 3 MC operating instructions

Precision Dynamics
Precision Dynamics Dynamic Descaler Application guide

Zoeller
Zoeller 132 installation instructions

Edwards
Edwards Microvac 149-HS instruction manual

IWAKI PUMPS
IWAKI PUMPS Hicera V Series instruction manual

Knauer
Knauer Azura P 6.1L user manual

Barmesa Pumps
Barmesa Pumps 4BSE-DS Series Installation, operation & maintenance manual