ascon ACK 20E User manual

Ceiling Cassette Split Systems
ACK - E - 2009
ACK/A5CK 20E/ER
ACK/A5CK 25E/ER
ACK/A5CK 28E/ER
ACK/A5CK 40E/ER
ACK/A5CK 50E/ER
Models:
Cover_A.indd 1Cover_A.indd 1 4/6/2009 12:04:24 PM4/6/2009 12:04:24 PM

ACK-E-2009 Table of Contents
“Acson” is a registered trademark of Acson International. All rights reserved.
© 2009 Acson International. All rights reserved throughout the world.
Bulletin illustrations cover the general appearance of Acson International products at the time of publication.
We reserve the right to change design and construction specifications at any time without notice.
Table of Contents
Nomenclature......................................................................................................................1
Indoor Unit .....................................................................................................................1
Outdoor Unit ..................................................................................................................2
Product Line-Up.............................................................................................................3
Features.............................................................................................................................10
Application Information ................................................................................................... 11
Operating Range ......................................................................................................... 11
Refrigerant Circuit Diagram .........................................................................................12
Controller ....................................................................................................................17
Installation Guideline ...................................................................................................20
Sound Data........................................................................................................................33
Sound Pressure Level .................................................................................................33
NC Curve.....................................................................................................................34
Engineering & Physical Data...........................................................................................37
General Data ...............................................................................................................37
Component Data .........................................................................................................53
Safety Devices ............................................................................................................69
Performance Data.............................................................................................................74
Calculation Steps.........................................................................................................75
Performance Table ......................................................................................................78
Outline and Dimension ..................................................................................................102
Electrical Data.................................................................................................................104
Wiring Diagram ............................................................................................................... 112
Service and Maintenance...............................................................................................121
Troubleshooting .............................................................................................................123
Exploded View and Part List .........................................................................................129
01_TOC_A.indd 301_TOC_A.indd 3 4/6/2009 5:18:36 PM4/6/2009 5:18:36 PM

Nomenclature ACK-E-2009
1
Nomenclature
Indoor
A 5 CK 20 E R
Brand
A : Acson
Refrigerant
“ “
4
5
: Omitted if R22
: R407C
: R410A
Model Name
CK : Ceiling Cassette
Capacity Index
20 : 20,000 Btu/h
Chassis
E : E Series
Model Type
“ “
R
: Omitted if cooling only
: Heatpump
02_Nomenclature_A.indd 102_Nomenclature_A.indd 1 4/6/2009 5:09:19 PM4/6/2009 5:09:19 PM

ACK-E-2009 Nomenclature
2
Outdoor
A 5 LC 20 C R
Brand
A : Acson
Refrigerant
“ “
4
5
: Omitted if R22
: R407C
: R410A
Model Name
LC : Single Split Condensing Unit
Capacity Index
20 : 20,000 Btu/h
Chassis
E : E Series
Model Type
“ “
R
: Omitted if cooling only
: Heatpump
02_Nomenclature_A.indd 202_Nomenclature_A.indd 2 4/6/2009 5:09:23 PM4/6/2009 5:09:23 PM

3
Product Line-Up ACK-E-2009
Product Line-Up
Indoor Unit
ACK-E Series
Model
Nomenclature
Classification
PCB
Handset
Fin
Refrigerant Control
Air Purification
Marking
Others
L2 08A
G18
Bare
Cap Tube
W/out Cap Tube
CE
Auto Air Swing
COOLING ONLY
20E ACOBA X X X X X X
25E ACOBA X X X X X X
28E ACOBA X X X X X X
40E ACOBA X X X X X X
50E ACOBA X X X X X X
HEATPUMP
20ER ACOBA X X X X X X
25ER ACOBA X X X X X X
28ER ACOBA X X X X X X
40ER ACOBA X X X X X X
50ER ACOBA X X X X X X
03_Product Line-Up_A.indd 303_Product Line-Up_A.indd 3 4/6/2009 11:05:24 AM4/6/2009 11:05:24 AM

4
ACK-E-2009 Product Line-Up
Indoor Unit
A5CK-E Series
Model
Nomenclature
Classification
PCB
Handset
Fin
Refrigerant Control
Air Purification
Marking
Others
L2 08A
G18
Bare
W/out Cap Tube
CE
Auto Air Swing
COOLING ONLY
20E ACOBA X X X X X X
25E ACOBA X X X X X X
28E ACOBA X X X X X X
40E ACOBA X X X X X X
50E ACOBA X X X X X X
HEATPUMP
20ER ACOBA X X X X X X
25ER ACOBA X X X X X X
28ER ACOBA X X X X X X
40ER ACOBA X X X X X X
50ER ACOBA X X X X X X
03_Product Line-Up_A.indd 403_Product Line-Up_A.indd 4 4/6/2009 11:05:27 AM4/6/2009 11:05:27 AM

5
Product Line-Up ACK-E-2009
Indoor Unit
ACK Panel Product Line Up
Model
Nomenclature
Classification
Handset
Marking
Others
G18
CE
Auto Air Swing
COOLING
ONLY
PLCKE-NG18 X X X
HEATPUMP
PLCKER-NG18 X X X
03_Product Line-Up_A.indd 503_Product Line-Up_A.indd 5 4/6/2009 11:05:27 AM4/6/2009 11:05:27 AM

6
ACK-E-2009 Product Line-Up
Outdoor Unit
ALC
Model
Nomenclature
Classification
Refrigerant Control
Fin
Compressor
Safety Devices
Marking
Others
Cap Tube
TXV
Gold Coated
Bare
Scroll / Digital Scroll
Rotary / Fixed Scroll
Contactor
High Pressure Switch
Low Pressure Switch
Phase Sequencer
CE
High Ambient Kit
Drain Elbow
COOLING ONLY
20C
ACPOD X X X X
ACPID X X X X
ACPHB X X X X X
ACPBD X X X X X
25C
ACPOD X X X X
ACPID X X X X
ACPBD X X X X X
ACPHB X X X X X
ACPSD X X X X X
28C
ACHOB X X X
ACHIB X X X
ACHBB X X X X
35C AFGE X X X X X X
AFGG X X X X X X
40C
AFGE X X X X X X
AFGG X X X X X X
FFGE X X X X X X X
FFGF X X X X X X X X
FFGG X X X X X X X
FFGL X X X X X X X
AUCOA X X X X X X
FUDOA X X X X X X
50C
FFGN X X X X X
FFGP X X X X X X X X
FFGQ X X X X X X X
FFGT X X X X X X X X
FUDOA X X X X X X
03_Product Line-Up_A.indd 603_Product Line-Up_A.indd 6 4/6/2009 11:05:27 AM4/6/2009 11:05:27 AM

7
Product Line-Up ACK-E-2009
Outdoor Unit
ALC
Model
Nomenclature
Classification
Refrigerant Control
Fin
Compressor
Safety Devices
Marking
Others
Cap Tube
TXV
Gold Coated
Bare
Scroll/ Digital Scroll
Rotary/ Fixed Scroll
Contactor
High Pressure Switch
Low Pressure Switch
Phase Sequencer
CE
High Ambient Kit
Drain Elbow
HEATPUMP
20CR
ACPOD X X X X
ACPID X X X X
ACPHB X X X X X
25CR
ACPOD X X X X
ACPID X X X X
ACPHB X X X X X
28CR ACHOB X X X
ACHIB X X X
35CR AFFB X X X X X X X X
AFFD X X X X X X X X
40CR
AFFB X X X X X X X X
AFFD X X X X X X X X
FFFB X X X X X X X X X
FFFD X X X X X X X X X
50CR FFFF X X X X X X X X X
FFFG X X X X X X X X X
03_Product Line-Up_A.indd 703_Product Line-Up_A.indd 7 4/6/2009 11:05:28 AM4/6/2009 11:05:28 AM

8
ACK-E-2009 Product Line-Up
Outdoor Unit
A5LC
Model
Nomenclature
Classification
Refrigerant Control
Fin
Compressor
Safety Devices
Marking
Others
Cap Tube
TXV
Gold Coated
Bare
Scroll/ Digital Scroll
Rotary/ Fixed Scroll
Contactor
High Pressure Switch
Low Pressure Switch
Phase Sequencer
CE
Drain Elbow
COOLING ONLY
20C
ACPIC X X X X
ACPOC X X X X
FCPOC X X X X X X
25C
ACPIC X X X X
ACPOC X X X X
FCPOC X X X X X X
28C
ACPOA X X X X
ACPIA X X X X
FCPOA X X X X X X
35C
ACCOB X X X X X X X
ACCGB X X X X X X X
FCCOB X X X X X X X X
FCCGB X X X X X X X X
40C
FCCGB X X X X X X X X
FCCOB X X X X X X X X
ACCOB X X X X X X X
ACCGB X X X X X X X
50C FCCOB X X X X X X X X
FCCGB X X X X X X X X
03_Product Line-Up_A.indd 803_Product Line-Up_A.indd 8 4/6/2009 11:05:29 AM4/6/2009 11:05:29 AM

9
Product Line-Up ACK-E-2009
Outdoor Unit
A5LC
Model
Nomenclature
Classification
Refrigerant Control
Fin
Compressor
Safety Devices
Marking
Others
Cap Tube
TXV
Gold Coated
Bare
Scroll / Digital Scroll
Rotary / Fixed Scroll
Contactor
High Pressure Switch
Low Pressure Switch
Phase Sequencer
CE
Drain Elbow
HEATPUMP
20CR
ACPIC X X X X
ACPOC X X X X
FCPOC X X X X X X
25CR
ACPIC X X X X
ACPOC X X X X
FCPOC X X X X X X
28CR
ACPOA X X X X
ACPIA X X X X
FCPOA X X X X X X
35CR
ACCOB X X X X X X X
ACCGB X X X X X X X
FCCOB X X X X X X X X
FCCGB X X X X X X X X
40CR
ACCGB X X X X X X X
ACCOB X X X X X X X
FCCOB X X X X X X X X
FCCGB X X X X X X X X
50CR FCCOB X X X X X X X X
FCCGB X X X X X X X X
03_Product Line-Up_A.indd 903_Product Line-Up_A.indd 9 4/6/2009 11:05:29 AM4/6/2009 11:05:29 AM

10
ACK-E-2009 Features
Features
Improved Sound Level
The new ACK-E series is equipped with a newly-developed turbo fan, which has improved the sound pressure
level of the unit significantly.
Lower Height Model
To ease installation, the overall height of the ACK-E series has been greatly reduces. (350mm for ACK-E,
290mm for ACK 20-28E/ER, 325mm for ACK 40-50E/ER).
Multi-Comfort – 3 Air Swing Pattern Control
To increase the comfort level of the air conditioned area of ACK-E series, the system had been built in with 3
different type of the air flow pattern to suit different requirement.
Built-in High Head Drain Pump
The unit has a built-in high head drain pump (with 700 mm drain head) to provide and ensure smoothness
drainage of condensate water.
Wireless Remote Controller
The compact LCD transmitter is able to operate the air conditioner unit within the distance of 8 meters.
Fan speed can be set at high / medium / low / super low or automatic.
Sleep mode auto control will gradually increase or decrease the setting temperature to provide a
comfortable surrounding for sleeping.
Air flow direction can be controlled automatically.
Room temperature is controlled by electronic thermostat.
The real time timer allows the air conditioner to be switched On and Off automatically based on user
settings.
Turbo mode function is available to enables the required set temperature to be achieved in a short time.
Personalized Setting allows user to preset and store 2 groups of personal settings (including timer setting)
in the handset.
•
•
•
•
•
•
•
•
04_Features_A.indd 1004_Features_A.indd 10 4/7/2009 5:27:36 PM4/7/2009 5:27:36 PM

11
Application Information ACK-E-2009
Application Information
Operating Range
Ensure the operating temperature is in allowable range.
Cooling only
Note :
Standard operating range.
Indoor temp. (°CDB)
Cooling
Outdoor temp. (°CDB)
Indoor temp. (°CWB)
Outdoor temp. (°CDB)
Indoor temp. (°CWB)
Heating
Outdoor temp. (°CWB)
-9
15 21
6
37
19
35
15
46
24
Standard
point
18
19
35
15
46
24
Standard
point
Standard
point
!Caution :
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
Heat Pump
05_Application Information_A.ind11 1105_Application Information_A.ind11 11 4/6/2009 3:32:43 PM4/6/2009 3:32:43 PM

12
ACK-E-2009 Application Information
70034 095231
Refrigerant Circuit Diagram
Model: ACK 20E - ALC 20C A5CK 25E - A5LC 25C
A5CK 20E - A5LC 20C
70034 049972
Model: ACK 25E - ALC 25C
A5CK 28E - A5LC 28C
05_Application Information_A.ind12 1205_Application Information_A.ind12 12 4/6/2009 3:32:48 PM4/6/2009 3:32:48 PM

13
Application Information ACK-E-2009
70034 049972
Model: ACK 28E - ALC 28C
70034 049181
Model: ACK 40E - ALC 35/40C
ACK 50E - ALC 50C
05_Application Information_A.ind13 1305_Application Information_A.ind13 13 4/6/2009 3:32:49 PM4/6/2009 3:32:49 PM

14
ACK-E-2009 Application Information
70034 097007
Model: A5CK 40E - A5LC 35/40C
A5CK 50E - A5LC 50C
70034 095238
Model: ACK/A5CK 20ER - ALC/A5LC 20CR
A5CK 25ER - A5LC 25CR
05_Application Information_A.ind14 1405_Application Information_A.ind14 14 4/6/2009 3:32:49 PM4/6/2009 3:32:49 PM

15
Application Information ACK-E-2009
70034 049972
Model: ACK 28ER - ALC 28CR
70034 049181
Model: ACK/A5CK 28ER - ALC/A5LC 28CR
05_Application Information_A.ind15 1505_Application Information_A.ind15 15 4/6/2009 3:32:50 PM4/6/2009 3:32:50 PM

16
ACK-E-2009 Application Information
70034 095246
Model: ACK 30ER - ALC 30CR
ACK 40ER - ALC 35/40CR
ACK 50ER - ALC 50CR
08014 085116
Model: A5CK 40ER - A5LC 35/40CR
A5CK 50ER - A5LC 50CR
05_Application Information_A.ind16 1605_Application Information_A.ind16 16 4/6/2009 3:32:50 PM4/6/2009 3:32:50 PM

17
Application Information ACK-E-2009
Controller
G18
1
2
3
4
5
6
8
9
7
10
11
12
13
14
15
Operation Guide
1 Transmission Source
The source where the signal will be transmitted.•
2 Signal Transmission Indication
Blink to confirm that the last setting has been transmitted
to the unit.
•
3 Temperature Setting
To set the desired room temperature, press the ▲or ▼
button to increase or decrease the set temperature.
The temperature setting range is from 16°C to 30°C
(optional setting 20°C to 30°C).
•
•
4 Personalize Setting
Press and hold for 3s, then will blink. Press again to
cycle between and .
Set the desire setting, then leave the handset for 4s
without pressing any key and it will save the setting into the
programme.
Press once to activate the P1 setting, press again to
cycle between P1 and P2.
Press any key to deactivate the personalize setting.
•
•
•
•
5 Automatic Air Swing (optional)
Press the SWING button to activate the automatic air
swing function.
To distribute the air to a specific direction, press the
SWING button and wait until the louver move to the
desired direction and press the button once again.
•
•
6 Silent Function
Press for quiet operation.
Fan speed turn to minimum speed.
Press again to deactivate the function.
•
•
•
7 Sleep Mode Setting
Press the SLEEP button will activate the sleep mode
function. This function is available under COOL, HEAT and
AUTO mode.
When the unit is operating under cooling mode, the set
temperature is increased by 0.5°C after 30 minutes, 1°C
after an hour, and 2°C after 2 hours.
When the unit is operating under heating mode, the set
temperature is decreased by 1°C after 30 minutes, 2°C
after an hour, and 3°C after 2 hours.
•
•
•
8 Operating Mode
Press the MODE button to select the type of operating
mode.
For cooling only unit, the available modes are: COOL (7),
DRY (6) and FAN ( ).
•
•
9 Fan Speed Selection
Press the button continuously will toggle the fan speed
in the following order:
Low BMed BHigh BAuto
Stop pressing when the desired fan speed appears on the
display screen.
•
•
10 “ON/OFF” Button
Press one to start the air conditioner unit.
Press again to stop the unit.
•
•
11 Timer Cancel
Press the TIMER CANCEL button to cancel the on timer
setting.
•
12 OFF Timer Setting
Press the OFF TIMER button will activate the off timer
function.
Set the desired off time by pressing the OFF TIMER button
continuously.
•
•
13 ON Timer Setting
Press the ON TIMER button will activate the on timer
function.
Set the desired on time by pressing the ON TIMER
button continuously. If the timer is set to 7.30am, the air
conditioner will turn on at 7.30am sharp.
•
•
14 Turbo Function
Press for fast cooling.
Fan speed turn to maximum speed.
Press again to deactivate the function.
•
•
•
15 Clock Time Setting
Press and hold to set the clock time.•
05_Application Information_A.ind17 1705_Application Information_A.ind17 17 4/6/2009 3:32:51 PM4/6/2009 3:32:51 PM

18
ACK-E-2009 Application Information
POWER TIMER SLEEP HEAT
Operation / Faulty Indication
Cool Mode
Time On
Sleep Mode On
Heat Mode
Auto Mode - Cool
Auto Mode - Heat
1 Time Compressor Overload
2 Times Pump Fault
3 Times Gas Leak
1 Time Room Sensor Open or Short
2 Times Indoor Coil Sensor Open or Short
3 Times Outdoor Coil Sensor Open or Short
ON ON or OFF Blinking
Operating State and Fault Table
Wireless Remote Control
Cooling : LED Indicator Light Display Heatpump : LED Indicator Light Display
POWER TIMER SLEEP POWER TIMER HEAT
05_Application Information_A.ind18 1805_Application Information_A.ind18 18 4/6/2009 3:32:51 PM4/6/2009 3:32:51 PM
This manual suits for next models
31
Table of contents
Other ascon Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PLA-M100EA installation manual

Samsung
Samsung AM***FN*D series user manual

LG
LG LS-J0761CL Service manual

Mitsubishi Electric
Mitsubishi Electric Mr. Slim PUZ-M200YKA2.UK Service manual

Carrier
Carrier 40GJB owner's manual

Airwell
Airwell Electra JMF Hi wall Series Service manual