ASTEL Cascada LPR36240 User manual

CASCADA
LPR36240
LPS36240
FOUNTAIN
LIGHT
Operating Instructions

2
CONTENTS
Preface...............................................................................................................................................................3
Features .............................................................................................................................................................3
Precautions ........................................................................................................................................................3
Components.......................................................................................................................................................4
Assembling and Installation ...............................................................................................................................5
Connection .........................................................................................................................................................6
Controls..............................................................................................................................................................7
Appearance........................................................................................................................................................8
Technical Specifications.....................................................................................................................................9
Warranty...........................................................................................................................................................10
Declaration of Conformity.................................................................................................................................11
_________________________________________________________________________________

3
PREFACE
The CASCADA series of modular
underwater/outdoor fountain light with built-in
driver is designed to use the latest LED lighting
technology.
The modular designed casing enables the
selection of different mounting options and
cable installations.
The CASCADA series is available in stainless
steel casings with high-grade polycarbonate
glass. The lighting is available in Warm White,
Cool White or RGB color with 36 high-power
LEDs.
The most advanced engine with built-in
microprocessor enables network connection
and simple control of complete groups of multi-
color lights through the complete rainbow
spectrum by using optional momentary switch
or optional DMX512 interfaces with built-in
ASTEL protocol.
FEATURES
•Modular Stainless Steel Casing
•Polished Finishing
•36 High-Power LEDs Design
•Warm White, Cool White or Multi-Color
RGB Lighting
•High Grade Polycarbonate Glass Optical
Window
•Vacuum Metalized Reflector
•Remote Control
•Digital Dimming
•Built-in ASTEL Protocol for DMX512
Control
•Polarity Protection
•Transient Protection
•Thermal Protection
•Low Power Consumption
•Simple Installation
PRECAUTIONS
•The fountain light has to be installed and
used in accordance with the instructions of
this manual only.
•The power supply has to be disconnected
before installation.
•Avoid using this unit near appliances
generating strong magnetic fields.
•The optical window has to be cleaned with
a mild soap or detergent and lukewarm
water by using a soft cloth or sponge. Do
not use abrasive or highly alkaline cleaners.
Never scrape with razor blades or other
sharp instruments. Benzene, leaded
gasoline, acetone or carbon tetrachloride
should never be used.
•Do turn power off immediately and refer
servicing to qualified service personnel if
the interior & exterior light does not operate
normally following the operating
instructions.

4
COMPONENTS
1 1 1 1
2 3 4 4
Model
Description
LPR36240
Rear Cable Inlet
LPS36240
Side Cable Inlet
Color of lighting
Desription
M
Red + Green + Blue
WW
Warm White
CW
Cool White
Mounting assembly
Description
-blank-
Fountain Light
FLM36
Flood Light
SLM36
Surface Light
HFL36
Outdoor Light, Round
HFL-SQ36
Outdoor Light, Square
(1) Fountain light
LED light CASCADA series built-in polished stainless-steel casing with different cable installations.
(2) Flood-light mounting assembly
For fixing of fountain modular designed LED light CASCADA series with adjusting of lighting angle.
(3) Surface-light mounting assembly
For fixing of fountain modular designed LED lights CASCADA series to the flat surface.
(4) Outdoor light mounting assembly
For fixing of fountain modular designed LED lights CASCADA series to the ground or wall with
heatsink and mounting bracket.

5
ASSEMBLING AND INSTALLATION
The modular fountain LED light CASCADA series can be used as stand-alone unit or combined with
the following assemblies.
•Flood-light mounting assembly
•Surface-light mounting assembly
•Outdoor light mounting assembly
The assembling and installation have to be realized by qualified personnel.
The CASCADA has to be assembled and fixed as shown in the drawings below:

6
Note:
•Do not cover the FOUNTAIN light body with any kind of temperature isolating material.
The FOUNTAIN light is protected by a temperature sensor against over-heating. When the
temperature of the FOUNTAIN light exceeds 85°C the FOUNTAIN light is automatically
switched off.
CONNECTION
The power supply has to be connected through the main switch (not included) with correct polarity
and protected by a fuse (not included). The power supply voltage has to be from 10 - 30Vdc.
Note:
•The power supply has to be switched off before installation.
The underwater light has to be connected as described in the table below:
CASCADA
wire color
FUNCTION
Red
+ DC Power Supply
Black
GND Power Supply
Orange
+ Control
Brown
GND Control
For basic control of the light the CONTROL wire has to be connected through the momentary switch
(not included) to the GND by using a 2-pole signal cable extension. (not included)
For DMX512 control optional LXU01 or LXU03 interface can be connected to the CONTROL and
GND wires by using a 2-pole signal cable (not included).
Note:
•When two or more lights are connected in the lighting system the control wires (red) can
be connected in parallel and all the lights then can be controlled by using only one
momentary switch or LXU01 (LXU03) interface.
Earthing
The fountain light has to be earthed by using a pre-tinned green wire with a yellow stripe a minimum
of 8 AWG (8.36 mm2). The wire has to be connected to the path light by the help of one fixing screw
M8x60
Synchronization
When more than one light is connected to the system the optional Synchronization Unit LSU08 is
recommended to synchronize the colors of lighting at the Rainbow Color Spectrum mode of lighting.
On the other case the colors of all installed lights would not be the same after few minutes or hours of
operation in the Rainbow Color Spectrum mode.
If the multi-color RGB light is used only with one of the fixed color of lighting the synchronization is
not necessary.

7
CONTROLS
Single-color warm white (WW) or cool white (CW)
Control by momentary switch
Remote control by momentary switch can be used to turn-on and turn-off the light and to control the
luminosity.
Turning on / off
Press the momentary switch momentary.
Dimming
When the light is on, press the momentary switch longer until the desired power is achieved.
Turning on minimum
When the light is off, press the momentary switch longer (e.g. one second or more) until the light is
turned on at minimum power.
Set default
Press the momentary switch for min. 40 seconds or until the light is turned off.
DMX512 control
The network connection to control the light with the standard DMX512 protocol is enabled by using
optional LXU01 or LXU03 interfaces.
Multi-color (RGB) model:
Control by momentary switch
Remote control by momentary switch has to be used to turn-on and turn-off the light and to control
the mode of lighting and luminosity.
When the light is turned-off the color or mode of lighting can be changed sequentially by pressing
the momentary switch for 2 seconds:
RGB
Sequence of lighting
Custom Color
Full RGB
Cool White
Bluish White
Red
Green
Blue
Rainbow Color Spectrum
Turning on /off
Press the momentary switch shortly.
Changing the color or mode of lighting
When the light is turned-off press the momentary switch for 2 seconds.

8
Setting the Custom Color
At the selected Rainbow Color Spectrum mode press the momentary switch shortly to turn the light
off. After that press the momentary switch for 5 seconds or until the light is switched to the selected
color and then the Custom Color is set and selected.
Dimming
When the light is turned-on press the momentary switch until the desired illumination is achieved. By
another pressing of the momentary switch the luminosity will increase to the maximum illumination.
Set default
Press the momentary switch for min. 40 seconds or until the light is turned off.
DMX512 control
The built-in ASTEL protocol enables the network connection to control the lights with the standard
DMX512 protocol by using optional LXU01 or LXU03 interfaces.
APPEARANCE

9
TECHNICAL SPECIFICATIONS
Power supply 12 – 24 Vdc, max. 4.3 A/12 Vdc or 1.9 A/24 Vdc
Lens angle 15°
Optical window High-grade polycarbonate glass
Luminous flux max. 5.700 lm
ASTEL protocol default address 1
Operating temperature -10°C - +50°C
Casing Stainless steel (316L)
Protection IP 68
Dimensions Ø189 x 31 mm
Weight 3.5 kg
The model specification:
CASCADA
-
-
MODEL code COLOR OF LIGHTING code MOUNTING ASSEMBLY code
Design and specifications subject to change without notice.

10
WARRANTY
1. The equipment manufactured by ASTEL d.o.o. is warranted to be free from defects in
workmanship and materials under normal use and service.
2. This Warranty is in effect for of two years from the date of purchase by the user. Proof of purchase
must be included, to establish that it is inside the warranty period.
3. This Warranty is transferrable and covers the product for the specified time period.
4. In case any part od the equipment proves to be defective, other than those parts excluded in
paragraph 5 below, the owner should do the following:
(a) prepare a detailed written statement of the nature and circumstances of the defect, to the best
of the Owner’s knowledge, including the date of purchase, the place of purchase, the name and
adress of the installer, and the Purchaser’s name, adress and telephone number;
(b) the Owner should return the defective part or unit along with the statement referenced in the
preceding paragraph to the warrantor, ASTEL d.o.o., or an authorized distributor,
postage/shipping prepaid and at the expense of the Purchaser;
(c) if upon the Warrantor’s or authorized distributor’s examination, the defect is determined to
result from defective material or workmanship, the equipment will be repaired or replaced at the
Warrantor’s option without charge, and returned to the Purchaser at the Warrantor’s expense;
(d) no refund of the purchase price will be granted to the Purchaser, unless the Warrantor is
unable to remedy the defect after having a reasonable number of opportunities to do so. Prior
to refund of the purchase price, Purchaser must submit a statement in writing from a
professional supplier that the installation instructions of the Operating Instructions manual have
been complied with and that the defect remains;
(e) warranty service shall be performed only by the Warrantor, or an authorized distributor, and
any attempt to remedy the defect by anyone else shall render this warranty void.
5. There shall be no warranty for defects or damages coused by faulty installation or hook-up, abuse
or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or
water immersion except for equipment specially designed as waterproof.
6. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its
employees and representatives for injury to any person or persons, or damage to property, loss of
income or profit, or any other consequential or resulting damage or cost which may be claimed to
have been incurred through the use or sale of the equipment, including any possible failure or
malfunction of the equipment, or part thereof.

11
DECLARATION OF CONFORMITY
according to IEC Guide 22 and EN 45014
Manufacturer's Name: ASTEL, Podjetje za projektiranje, proizvodnjo in
trgovino, d.o.o.
Manufacturer's Address: Dutovlje 138
6221 Dutovlje
Slovenija
declares that the products
Item, Product Name and Model Number: 1. Fountain LED light CASCADA series
conform to the following Product Specifications:
EMC: EN 55015:2006 + A1:2007
EN 61547:1995 + A1:2000 + A2:2009
EN 61547:2009
Safety: EN 60598-2-18:1995/A1:2012
EN 60529:1992+A2:2013
Supplementary Information:
The products herewith comply with the requirements of the following Directives and carry the CE-
marking accordingly:
-the Low Voltage Directive 2014/35/EU
-the EMC Directive 2014/30/EU
-the RoHS Directive (EU)2015/863
ASTEL d.o.o.
Dutovlje 138
6221 Dutovlje
Slovenija
18th January, 2017

12
ASTEL d.o.o., Dutovlje 138, 6221 Dutovlje, Slovenia
Tel: +386 5 7310771, +386 5 7310772
Fax:+386 5 7310789
E-mail: info@astel-lighting.com
Web: www.astel-lighting.com
This manual suits for next models
1
Table of contents
Popular Light Fixture manuals by other brands

LEDOLUX
LEDOLUX HERMES LOG N instruction manual

Nobile
Nobile R1S operation instruction

Chauvet DJ
Chauvet DJ Intimidator Spot 375ZX user manual

Uplus Lighting
Uplus Lighting 230 SPOT user manual

Modulex
Modulex MSP-080A/10B/DL/3 installation guide

elsner elektronik
elsner elektronik 71162 Installation and adjustment