ATIM Cloud Wireless DINDIO User manual

-
ATIM Cloud Wireless
Digital Input and Output
DINDIO
User Guide
Concerned model:
ACW/868 –DINDIO

2
ATIM_ACW-DINDIO_868_UG_EN_V1.3
TABLE OF CONTENTS
Document version history ............................................................................................................................................. 3
Disclaimer............................................................................................................................................................................. 3
Trademarks and copyright............................................................................................................................................ 3
Declaration of compliance............................................................................................................................................. 4
Environmental recommendations ............................................................................................................................. 4
Explosive atmosphere ................................................................................................................................................ 4
Environment................................................................................................................................................................... 4
Radio.................................................................................................................................................................................. 5
Technical specifications.................................................................................................................................................. 6
Footprint and installation.............................................................................................................................................. 7
Set up...................................................................................................................................................................................... 8
a. Positioning...................................................................................................................................................................................8
b. Modem connection...................................................................................................................................................................8
Configuration du modem ............................................................................................................................................... 9
a. Local mode configuration 868MHz...................................................................................................................................9
Lights meaning.................................................................................................................................................................10
a. Local 868MHz..........................................................................................................................................................................10
Frames format ..................................................................................................................................................................11
Modbus Slave configuration...................................................................................................................................11
Modbus Master configuration...............................................................................................................................12
Modbus table................................................................................................................................................................12
Supported Modbus Functions ...............................................................................................................................13
Data decoding ..............................................................................................................................................................13
Use case ...............................................................................................................................................................................14
Simple mirror mode between two ACW-DINDIO..........................................................................................14
Simple mirror mode between a ACW-DI and a ACW-DINDIO .................................................................16
Multiple mirror mode...............................................................................................................................................17
Help.......................................................................................................................................................................................18
The modem is not configured via USB or the configurator page does not update..........................18
Radio data is not received.......................................................................................................................................18
Counter index does not increment......................................................................................................................18
LED does not flash......................................................................................................................................................18
Technical support............................................................................................................................................................18

3
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Document version history
Version
document
Date
Description
Author
Concerned
soft version
0.1
13/11/2015
Creation
YL
0.2
03/04.2016
DIN version
AM
1.3
04/01/2018
Corrections
SC
1.1
Disclaimer
The information contained in this document is subject to change without warning and does not
represent a commitment on the part of ATIM radiocommunications. ATIM radiocommunications
provides this document ‘as-is’ with no warranty of any kind, express or implied, including but not
limited to implied warranties of merchantability or fitness for a particular purpose. ATIM
radiocommunications may make changes and/or improvements to this manual or to the product(s) or
program(s) described in this manual, at any time.
Trademarks and copyright
ATIM radiocommunications®, ACW ATIM Cloud Wireless® and ARM Advanced Radio Modem® are
registered trademarks of ATIM SARL in France. The other trademarks mentioned in this document are
the property of their respective owners.

4
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Declaration of compliance
All ACW Atim Cloud Wireless® products comply with the regulatory requirements of the R&TTE
Directive (1999/5/EC), article 3:
1 SAFETY (Article 3.1a of the 1999/5/EC Directive)
NF EN60950-1 Ed. 2006/A1:2010/A11:2009/A12:2011 (health)
EN62479: 2010 (power <20mW) or EN62311:2008 (power > 20mW)
2 Electromagnetic compatibility (Article 3.1b of the 1999/5/EC Directive)
EN 301489-3 v1.4.1, EN 301489-1 V1.9.2
3 Efficient use of the radio frequency spectrum (Art.3.2 of the 1999/5/EC Directive)
ETSI EN300 220-2 v2.4.1 and EN300 220-1 v2.4.1
Environmental recommendations
Explosive atmosphere
Except for the ACW-ATEX line specifically intended for this purpose, do not use ACW radio modems in
the presence of flammable gases or fumes. Using the equipment in such an environment constitutes a
safety hazard.
Environment
Respect the temperature ranges for storage and operation of all products. Failing to respect these
guidelines could disrupt device operation or damage the equipment. ACW products in IP65 water- and
dust-resistant housings may be placed outdoors, but must not, under any circumstances, be submerged.
Follow the instructions and warnings provided below to ensure your own safety and that of the
environment and to protect your device from any potential damage.

5
ATIM_ACW-DINDIO_868_UG_EN_V1.3
General hazard –Failure to follow the instructions presents a risk of equipment damage.
Electrical hazard –Failure to follow the instructions presents a risk of electrocution and physical
injury.
Direct-current symbol
WARNING: do not install this equipment near any source of heat or any source of humidity.
WARNING: for your safety, it is essential that this equipment be switched off and disconnected from mains
power before carrying out any technical operation on it.
WARNING: the safe operation of this product is ensured only when it is operated in accordance with its
intended use. Maintenance may only be performed by qualified personnel.
Waste disposal by users in private households within the European Union. This symbol appears on a
product or its packaging to indicate that the product may not be discarded with another household waste.
Rather, it is your responsibility to dispose of this product by bringing it to a designated collection point for
the recycling of electrical and electronic devices. Collection and recycling waste separately at the time you
dispose of it helps to conserve natural resources and ensure a recycling process that respects human health
and the environment. For more information on the recycling centre closest to your home, contact your
closest local government office, your local waste management service or the business from which you
purchased the product.
Radio
Modems in the ACW line are radio-communication modems that use the ISM (industrial, scientific and
medical) bands, which may be used freely (at no cost and with no authorisation required) for industrial,
scientific and medical applications.

6
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Technical specifications
Dimensions
90 x 57 x 67 mm
Antenna
External (SMA connector)
Temperature
-20°C to +55°C (operating)
-40°C to +70°C (storage)
Mounts to
DIN-Rail
Battery
1 x alimentation 10-30Vcc
Frequency
865 –870 MHz
Power
25 mW (14 dBm)
Rate
Local: 1.2 to 115 Kbit/s
LoRa: 300 bit/s to 10 Kbit/s
Consumption
Local
LoRa
Mode Tx
60 mA
50 mA
Mode Rx
35 mA
10 mA
Standby mode
10 mA
10 mA

7
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Footprint and installation
Dimensions give in mm.
ACW modems in ‘breaker’ format are attached to a DIN-rail.

8
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Set up
a. Positioning
This version was designed for installation in an electrical box made of PVC or metal. If the cabinet is
made of insulating material (PVC, ABS, fiberglass), it is possible to simply use a small whip-wave
antenna: Ref ATIM ANT868-12FSC. This antenna must be firmly screwed on the SMA connector and
positioned vertically, preferably upwards.
➔In the case of a metal box, it is imperative to deport the antenna to the outside to have good
results in radio (avoid the Faraday cage!)
For best results, it is advisable to move the antenna up and clear of any metal obstacle within a radius
of 1 meter if possible.
b. Modem connection
Terminals:
Antenna (SMA):
Before powering the product, a 50Ω / 868MHz antenna must be connected, either
directly to the SMA connector or via a 50Ω cable in case of antenna offset.
Alimentation (Lower terminal):
The ACW-DIO module must be powered with a continuous power supply between 10V
and 30V.
OUT (Lower terminal):
The logic output is MOSFET current source (N channel), 10-30Vdc. The maximum
charging current is 0.2A.
IN1/IN2 (Upper terminal):
You can connect up to two inputs in 10-30Vdc positive logic. The filter of the input is 250
ms. The maximum recommended cable length and 1 meter.
USB:
The USB connector is used to configure the ACW via a PC and a USB cable.
➔The configuration must be done with the device powered by 10 / 30Vdc.
Name
Designations
Input / Output
GND
Ground
Input
10/30V
Alimentation between 10V and
30V
Input
OUT
Digital output 10-30Vdc
Output
NC
Not connected
/
IN1
Digital input 1
Input
IN2
Digital input 2
Input

9
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Configuration du modem
Download and install the configuration software '' setupACW.exe '' at:
http://www.atim.com/produit/atim-cloud-wireless-acw/
Connect the module to your computer with a USB cable and then launch the software.
When you connect the module, the software window changes to allow you to access the main features.
Automatically, the current configuration of the connected module is retrieved and displayed.
a. Local mode configuration 868MHz
✓Operating mode
Three operating modes are available: slave, master or mirror.
oSlave mode it is your remote device that will interrogate the ACW-DIO.
oIn Master mode, the ACW-DINDIO will periodically send (from 10min to 24h) or on a change
of state the values of the recorded entries.
oIn Mirror mode, communication is done between two ACW-DIOs every 500ms. A copy of the
input and output is performed between two remote modems. One of the two modems must
be identified as master and the other as a slave, which can be defined in the "Operating mode"
window of the "Mirror" tab.
✓Inputs configuration
The ACW-DINDIO module has 2 configurable inputs. Each entry can be activated or not. The signal
must be made by a 10-30V contact.
✓Radio parameters
oThe radio channel must be the same between your different devices wanting to communicate
together.
oThe baudrate must be the same between your different equipment wanting to communicate
together.

10
ATIM_ACW-DINDIO_868_UG_EN_V1.3
oThe modem address is the address of your ACW-DINDIO, each modem must have a different
address.
oThe remote address is the address of the device with which you want to communicate.
oTimeOut acts as a watchdog. It is configurable from 0 (disabled) to 10 seconds. If no frame
has arrived at the product within this time, then the modem output goes to 0.
If you do not set one of the statement periods fields. When you click the Write key, an Invalid message
will appear next to it and a window will indicate which field is in default.
✓Setup
Once you have completed the configuration, click on the Write button to validate it. After a few
seconds of waiting, a message appears next to it to inform you if the module update succeeded or
failed.
Note
This is when the module synchronizes with the time of your PC.
✓Default
Resets the original values. After clearing the saved values, you can configure the ACW-DIO again.
Once the configuration is complete, do not leave the module connected to USB. This mode
of operation is very energy intensive. When you remove the USB link without disconnecting
the power, the modem automatically returns to normal operation. On power up, a first radio
transmission is made in the 60s.
Lights meaning
In USB configuration mode, the green LED flashes slowly until the configuration is completed and the
USB cable is removed.
a. Local 868MHz
The green status indicator illuminates when the product is powered. After a few seconds, a data
transmission is performed. If the request is successful, the green LED illuminates briefly, in case of a
failure the red LED lights up.

11
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Frames format
In point-to-point or point-to-multipoint local communication mode, the Modbus RTU protocol is used.
Modbus mode is commonly used with a Modbus master controller or with a supervisor connected to an
ACW-RS or an ARM-SE. Download the configuration software from:
http://www.atim.com/product/atim-cloud-wireless-acw/la-new-gamera-atim-cloud-wireless
The main functions are:
•Digital inputs lecture
•Lecture and writing of the digital output
•Analogical input lecture (ACW-DA version)
•Metering lecture and writing
Modbus Slave configuration

12
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Modbus Master configuration
Modbus table
Modbus Adress
Data
0x00 (0)
Digital inputs lecture
b0: Input 1 state
b1: Input 2 state
0x40 (64)
Meter input 1 lecture and writing (b31
to b16)
0x41 (65)
Meter input 1 lecture and writing (b15
to b0)
0x42 (66)
Meter input 2 lecture and writing (b31
to b16)
0x43 (67)
Meter input 2 lecture and writing (b15
to b0)

13
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Supported Modbus Functions
Function
Type
0x03 (3)
Various registers lecture
0x10 (16)
Various registers writing
Data decoding
Slave Id
1 octet
Slave Modbus ID
14
Code Function
1 octet
0x10 (Write multiple
registers)
10
Start Address
2 octets
MSB = 0x40, LSB=Slave Id
40001
Quantity of
registers
2 octets
Number of registers to write
0004
Bytes count
1 octet
Number of octets to write
08
Counter 1 MSB-
LSB
4 octets
Metering input 1
00000012
Counter 2 MSB-
LSB
4 octets
Metering input 2
00000008
CRC
2 octets
Errors control code
XXXX
SLAVE
ID
FUNC
START ADDR
REG QTY
BYTES
COUNT
COUNTER 1
MSB
COUNTER 1
LSB
COUNTER 2
MSB
COUNTER 2
LSB
CRC

14
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Use case
Mirror mode allows copying of digital inputs to one or more remote radio modems. In simple mirror
mode, the copy is made from one module to another (and vice versa). In multiple mirror mode, it is
possible to have a master module to several slave modules. The transmission is cyclic or triggered
(change of state).
Download the configuration software from: http://www.atim.com/product/atim-cloud-wireless-
acw/la-new-gamera-atim-cloud-wireless
Simple mirror mode between two ACW-DINDIO
ACW-DIO
Slave Modem
ACW-DIO
Master Modem

15
ATIM_ACW-DINDIO_868_UG_EN_V1.3
In this configuration, the master modem and the slave modem have identical configuration of the inputs
and outputs, the master modem sends a radio frame representing the state of its inputs to the slave
modem which copies the state of the received inputs to its outputs and which immediately returns the
status of its entries to the master modem.
Click on the 3rd tab of the configuration tool called "Mirror". One of the two modems must be declared
as master and the other as a slave using the "Operating mode" drop-down list.
The "@Modem" modem address of the slave product must match the "@Remote" address of the master
product. The radio channel and the baudrate must also be identical on both products. Please refer to
the ARM-Nano User Guide for the frequency corresponding to the channel. TimeOut acts as a watchdog.
It is configurable from 0 (disabled) to 10 seconds. If no frame has arrived at the product within this
time then the modem output goes to 0.
The master modem instantiates communication with the slave modem to send the state of its input 1
and retrieve the state of input 1 of the slave modem. In order to enable you to validate the installation,
the green leds on both modems must illuminate when the communication is effective.

16
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Simple mirror mode between a ACW-DI and a ACW-DINDIO
In this configuration, the master modem sends the frame on a change of state of its digital inputs to the
slave modem.
The ACW-DI with battery must be configured in master mode, it is him who will instantiate the
communication during a change of state of its entry. The ACW-DINDIO will be configured as a slave to
assign the value sent from the master to its output.
The "@Remote" address of the ACW-DI master must match the "@Modem" slave address of the ACW-
DINDIO, so that communication is valid between the two products.
In order to allow you to validate the installation, the green leds must light up on both modems when
the communication is effective.
The "Remote" address on the ACW-DI master product must match the "Modem" address on the ACW-
DIO slave product.
ACW-DI
Master Modem
ACW-DIO
Slave Modem

17
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Multiple mirror mode
In this configuration, there is a master modem and several slave modems. The master modem cyclically
sends the state of its input to the slave modems. In this mode, slave modems do not respond to the
master. The "@Remote" address of the master modem must be set to 0 in order to broadcast (broadcast
to all slaves without distinction of address). Slave modems must be set to "Slave".
ACW-DIO
Master Modem

18
ATIM_ACW-DINDIO_868_UG_EN_V1.3
Help
The modem is not configured via USB or the configurator page does not update
•Check if the power supply is properly connected to the modem
•Check if the green light is flashing
•Check that "Windows Update" is enabled, that the PC is connected to the Internet and that the
driver installation is complete. Also check that your version of the configurator is up to date
(Menu File -> Update).
•Replace the USB cable
•In case of Failed to write the configuration, unplug and reconnect the USB cable
Radio data is not received
•Check if the power supply is properly connected to the modem
•Check if the modem has been registered on the network
•Check if radio network coverage is available
•Check if the green lights flash during a broadcast
Counter index does not increment
•Check if the counter wires are not reversed and plugged into the terminal block
•Check if your reading head is well sized for your use (liters, m3)
•Check that the output of your meter does not exceed 5V in the case of a push-pull output
LED does not flash
•Check if the power supply is properly connected to the modem
•USB Configure the modem using the USB configurator
Technical support
For any information or technical problems, you can contact our technical support by e-mail and phone:
www.atim.com/fr/technical-support
This manual suits for next models
1
Table of contents
Popular I/O System manuals by other brands

Automationdirect.com
Automationdirect.com Productivity 1000 P1-15CDD2 manual

National Instruments
National Instruments Data Acquisition Device NI USB-621x user manual

GeoVision
GeoVision GV-NET/IO instruction manual

ABB
ABB VSN300s manual

Honeywell
Honeywell 2MLF-AV8A user guide

M-system
M-system R7ML-DA16 instruction manual